Keysight Technologies Infiniium Z-Series Oscilloscopes Data Sheet Achieve new extremes –– 63 GHz of real-time bandwidth on 1 or 2 channels –– 33 GHz of real-time bandwidth on 2 or 4 channels Introduction Achieve new extremes With the emergence of technologies pushing hundreds of Gb/s, an oscilloscope must now have high bandwidth, low noise and fast processing. That is the idea behind the Keysight Technologies, Inc. Infiniium Z-Series oscilloscopes. They feature up to 63 GHz of real-time oscilloscope bandwidth and the industry’s lowest noise and jitter measurement floors. Featuring –– 63 GHz of real-time oscilloscope bandwidth –– The industry’s only upgradable channel oscilloscope in a single frame (from 2 to 4 channels) –– The industry’s lowest noise and jitter measurement floor –– The industry’s highest ENOB at bandwidths up to 63 GHz –– The industry’s deepest memory (up to 2 Gpts) DSAZ634A DSOZ634A DSAZ632A DSOZ632A DSAZ594A DSOZ594A DSAZ592A DSOZ592A DSAZ504A DSOZ504A DSAZ334A DSOZ334A DSAZ254A DSOZ254A DSAZ204A DSOZ204A The Infiniium Z-Series captures rise times as fast as 5 ps (20/80). Bandwidth 1 channel 2 channel 4 channel Sample rate 1 channel 2 channel 63 GHz 63 GHz 33 GHz 160 GSa/s 160 GSa/s 63 GHz 33 GHz — 160 GSa/s 80 GSa/s 59 GHz 59 GHz 33 GHz 160 GSa/s 160 GSa/s 59 GHz 33 GHz — 160 GSa/s 80 GSa/s 50 GHz 50 GHz 33 GHz 160 GSa/s 160 GSa/s 33 GHz 33 GHz 33 GHz 80 GSa/s 80 GSa/s 25 GHz 25 GHz 25 GHz 80 GSa/s 80 GSa/s 20 GHz 20 GHz 20 GHz 80 GSa/s 80 GSa/s Memory depth 4 channel Standard Maximum 100 Mpts 2 Gpts 80 GSa/s 50 Mpts 2 Gpts 100 Mpts 2 Gpts — 50 Mpts 2 Gpts 100 Mpts 2 Gpts 80 GSa/s 50 Mpts 2 Gpts 100 Mpts 2 Gpts — 50 Mpts 2 Gpts 100 Mpts 2 Gpts 80 GSa/s 50 Mpts 2 Gpts 100 Mpts 2 Gpts 80 GSa/s 50 Mpts 2 Gpts 100 Mpts 2 Gpts 80 GSa/s 50 Mpts 2 Gpts 100 Mpts 2 Gpts 80 GSa/s 50 Mpts 2 Gpts 03 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Table of Contents Introduction���������������������������������������������������������������������������������������������������������������������������������������������������2 Advanced IC Design and Technology Help You Solve Your Biggest Problems��������������������������������������������4 The Oscilloscope — Digital Measurement and Analysis�������������������������������������������������������������������������������5 The Spectrum Analyzer — Radar and Satellite Communications Analysis��������������������������������������������������6 The Optical Modulation Analyzer������������������������������������������������������������������������������������������������������������������7 The Network Analyzer — Time-Domain Transmission (TDT)������������������������������������������������������������������������8 The World’s Fastest Probing System For Your Highest Performance Needs����������������������������������������������9 Achieve Your Real Edge������������������������������������������������������������������������������������������������������������������������������� 11 Achieve New Extremes�������������������������������������������������������������������������������������������������������������������������������� 12 Analysis Tools: PrecisionProbe Basic and Advanced (N2809A and N2807B)�������������������������������������������� 18 Analysis Tools: EZJIT, EZJIT Plus and SDA (Standard on DSA Models)���������������������������������������������������� 19 Analysis Tools: EZJIT Complete (Standard on DSA Models)����������������������������������������������������������������������20 Analysis Tools: InfiniiSim (N5465A)�������������������������������������������������������������������������������������������������������������21 Analysis Tools: Serial Data Equalization (N5461A)�������������������������������������������������������������������������������������22 Analysis Tools: InfiniiScan (N5414B)������������������������������������������������������������������������������������������������������������22 Analysis Tools: N8900A Infiniium Offline Oscilloscope Analysis Software������������������������������������������������23 Analysis Tools: User-Defined Function (N5430A)��������������������������������������������������������������������������������������� 24 Analysis Tools: Complete List of Analysis Software����������������������������������������������������������������������������������� 24 Compliance and Automated Testing�����������������������������������������������������������������������������������������������������������25 Compliance and Automation Testing: User-Defined Application (N5467B)����������������������������������������������26 Compliance and Automation Testing: Switch Matrix Support�������������������������������������������������������������������27 Compliance and Automation Testing: Other Options on Z-Series Oscilloscopes��������������������������������������28 Protocol Analysis�����������������������������������������������������������������������������������������������������������������������������������������29 Achieve New Extremes��������������������������������������������������������������������������������������������������������������������������������31 Specifications�����������������������������������������������������������������������������������������������������������������������������������������������34 Keysight Oscilloscopes�������������������������������������������������������������������������������������������������������������������������������� 42 Evolving Since 1939�������������������������������������������������������������������������������������������������������������������������������������44 04 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Advanced IC Design and Technology Help You Solve Your Biggest Problems At the extremes of electrical and optical measurements ... You need to make rise time measurements without being limited by scope bandwidth The Z-Series is Keysight Technologies’ second generation of enabling 63 GHz of oscilloscope bandwidth. RealEdge technology is implemented using a unique combination of time interleaving, frequency interleaving and proprietary signal processing. You need to see your signal and not oscilloscope noise The Z-Series leverages technology from the award-winning Infiniium 90000X and 90000Q Series oscilloscopes, which provide leading signal integrity specifications. The Z-Series takes advantage of leading-edge indium phosphide chip technology and custom thin film packaging technology, which ultimately leads to the lowest-noise-, real-time oscilloscope in the world. With industry-leading bandwidths, Z-Series scopes let you see your fastest signals as they really are. RealEdge technology blocks enable 63-GHz real-time bandwidth. You need fast analysis and hardware acceleration The Z-Series has a capacitive touch screen, new processor and 16 GB of RAM to ensure faster processing than previousgeneration Infiniium oscilloscopes. Infiniium’s custom multi-chip modules feature indium phosphide chips and Keysight proprietary packaging technology, enabling high bandwidth and low noise. 05 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The Oscilloscope — Digital Measurement and Analysis With 63 GHz of bandwidth to capture rise times as fast as 5 ps and recover clocks on NRZ data rates as fast as 120 Gbit/s, the Z-Series is the world’s fastest real-time oscilloscope. Its four channels at 33 GHz make it ideal for 32 Gb/s and greater SERDES designs. In addition to providing leading-edge bandwidth, the Z-Series helps you to find your real edge, by featuring the industry’s lowest noise and jitter measurement floor, which means less scope noise in your measurements and a truer depiction of your signal. Capture, display and measure multiple real-time eyes simultaneously with the Z-Series. Z-Series features the following to enable extreme digital analysis 1. 2. 3. 4. 5. Full offline analysis Flexible user interface that supports multiple displays and multi-touch Two unique jitter separation algorithms, including bounded uncorrelated jitter (BUJ) breakdown Clock recovery on NRZ data rates as fast as 120 Gb/s Memory depth that captures milliseconds of data at 160 GSa/s With its flat frequency response and low noise, the Z-Series is able to accurately measure jitter components such as ISI. With the 63 GHz bandwidth, the Z-Series is able to effectively characterize the time interval error trend of high speed signals as well as fast rising edges, down to 5 ps. 06 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The Spectrum Analyzer — Radar and Satellite Communications Analysis You need to easily compute both magnitude and phase Infiniium Z-Series oscilloscopes include a Fast Fourier Transform (FFT) for frequency domain (spectrum) analysis. The integrated FFT offers an alternative to a dedicated spectrum analyzer. Use the FFT to compute both magnitude and phase and take advantage of several useful features to assist in spectral analysis. The FFT can control span and resolution bandwidth. Automatic measurements and markers measure spectral peak frequencies and magnitudes as well as deltas between peaks. Use the amplitude demodulation (envelope mode) to measure rise and fall times on the entire envelope. The Z-Series FFT quickly identifies peaks and has key controls such as span, start and stop, which make the oscilloscope behave more like a spectrum analyzer. Z-Series features the following to enable extreme RealEdge analysis –– Multiple FFT windows including Hanning, rectangular, BlackmanHarris, flattop, and Hamming –– Peak search and navigation for fast analysis –– Amplitude modulation (envelope mode) — create radar envelopes –– FFT mask trigger –– Gated FFT measurements Ampltitude demodulation makes it possible to analyze difficult waveforms such as envelopes. Use the FFT mask to test frequency margins and capture rare events. 07 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The Optical Modulation Analyzer Z-Series oscilloscopes are also available in combination with the N4391A optical modulation analyzer as a fully specified turn-key instrument. This compact solution offers the highest bandwidth available on the market and is the most advanced test solution for advanced research on 400G and terabit transmission. Even for the lower 20 GHz bandwidth range, this compact and easy-to-use solution is a reference system for 100G transmission required by R&D labs working at 100G and beyond. By providing four channels of up to 63 GHz bandwidth, the Z-Series saves you the expense of a second instrument to analyze dual polarization. If you prefer to operate with your own optical receivers but want to benefit from the enormous analysis capability, you can get the N4391A’s analysis software as a standalone package. Features and benefits –– Up to 63 GHz true analog bandwidth on four channels by time synchronizing two 2-channel, 63 GHz scopes –– Up to 33 GHz true analog bandwidth on four channels in one scope –– Up to 120 Gbaud symbol rate analysis –– Four times better EVM noise floor than typical QPSK transmitter –– Compact four channels in turn-key solution –– Up to four 160 GSa/s real-time sampling for optimal phase tracking –– Well-defined interface to include your own MATLAB algorithms –– Customer-configurable APSK and OFDM decoders The N4391A offers a powerful toolset to debug the most challenging errors, with tools proven by thousands of RF engineers. 08 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The Network Analyzer — Time-Domain Transmission (TDT) You need to be able to maximize your margins by removing the effects of cables and fixtures As bandwidths continue to increase and cable loss becomes more and more of a problem, the Z-Series has the technology to solve this issue. The Z-Series oscilloscopes offer award-winning PrecisionProbe Advanced technology. You no longer need to ignore cable loss because you are short on time or budget. Using PrecisionProbe Advanced technology, you can characterize cables as fast as 63 GHz and remove the loss they create. PrecisionProbe Advanced technology gives you one of the world’s fastest edges at less than 5 ps and uses this edge to perform a TDT on your cable. Based on the loss of your cable, PrecisionProbe Advanced then compensates your measurement system, gaining back valuable margin typically lost in cables. You need to test multiple lanes automatically and still maximize margins The Z-Series features many compliance applications, which provide full automation of any switch connected to your system. The software is fully compatible with PrecisionProbe Advanced compensation, which allows you to characterize every input using only your Z-Series oscilloscope and then seamlessly automate every measurement in your compliance application. Save valuable time and resources in such technologies as DisplayPort and PCI Express ® Gen3. By analyzing cables you can increase your margins by removing insertion loss caused by cables. 09 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The World’s Fastest Probing System For Your Highest Performance Needs The InfiniiMax III and III+ probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fidelity and accuracy. Eight different InfiniiMax probe amplifiers ranging from 8 to 30 GHz are available for matching your probing solution to your performance and budget requirements. The InfiniiMax III and III+ probe system is unmatched by any product in the market. It uses a proprietary 200 GHz transistor switching speed indium phosphide IC process with backside ground vias and novel thick-film technology to accommodate your highestperformance needs. Industry’s only upgradable probing system. 010 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The World’s Fastest Probing System For Your Highest Performance Needs (Continued) Description 30-GHz InfiniiMax III probe amplifier 25-GHz InfiniiMax III probe amplifier 20-GHz InfiniiMax III probe amplifier 16-GHz InfiniiMax III probe amplifier 20-GHz InfiniiMax III+ probe amplifier 16-GHz InfiniiMax III+ probe amplifier 13-GHz InfiniiMax III+ probe amplifier 8-GHz InfiniiMax III+ probe amplifier ZIF probe head Browser (handheld) probe head Solder-in probe head PC board ZIF tip 3.5/2.92/SMA probe head Performance verification fixture Solder-in probe head 450-ohm ZIF tip kit (set of five) 200-ohm ZIF tip kit (set of five) Browser tip replacement Precision BNC adaptor Sampling scope adaptor 2.92-mm flexible cable High-impedance probe adaptor 35-GHz flexible cable Probe or accessory N2803A N2802A N2801A N2800A N7003A N7002A N7001A N7001A N5439A N5445A N5441A N2838A N5444A N5443A N2836A N5440A N5447A N5476A N5442A N5477A N5448B N5449A N2812B Bandwidth 30 GHz 25 GHz 20 GHz 16 GHz 20 GHz 16 GHz 13 GHz 8 GHz 28 GHz 30 GHz 16 GHz 25 GHz 28 GHz 30 GHz 26 GHz 28 GHz 28 GHz 30 GHz 13 GHz 30 GHz 30 GHz 500 MHz 35 GHz 11 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve Your Real Edge Having the right amount of oscilloscope bandwidth ensures accurate measurements. If you have too much bandwidth, oscilloscope noise becomes a contributor in your measurement. With too little bandwidth, rise times are improperly depicted. Use the chart below to find the correct oscilloscope bandwidth for the devices you are measuring. Recommended scope bandwidth Technology Ethernet 10BASE-T Ethernet 100BASE-T Ethernet 1000BASE-T USB 2.0 USB 3.1 Gen 1 USB 3.1 Gen 2 DDR1 DDR2 DDR3 DDD4 GDDR5 SATA 3G SATA 6G SAS-2 SAS-3 16G FibreChannel HDMI 1.4 DisplayPort 1.2 10G Ethernet 10Gbase-KR XAUI MIPI® M-PHY® MIPI D-PHYSM PCI Express 2 PCI Express 3 28/32G FibreChannel Thunderbolt 3 SFP + MHL InfiniBand II Data rate 10 Mbps 100 Mbps 250 Mbps x 4 480 Mbps 5 Gbps 10 Gbps 400 MT/s 1066 MT/s 2133 MT/s 3200 MT/s 8 Gbps 3 Gbps 6 Gbps 6 Gbps 12 Gbps 14.025 Gbps 3.4 Gbps 17.28 Gbps 10 Gbps 10.3125 Gbps 3.75 Gbps 5.83 Gbps 2.5 Gbps 5 Gbps 8 Gbps 28 Gbps 20.625 Gbps 10 Gbps 2.25 Gbps 2.5 Gbps, 5 Gbps Fastest rise time 30 ns 3 ns 1.2 ns 300 ps 50 ps 25 ps 500 ps 250 ps 100 ps 75 ps 30 ps 67 ps 33 ps 42 ps 21 ps 24 ps 50 ps 50 ps 60 ps 24 ps 60 ps 17.2 ps 100 ps 30 ps 25 ps 18 ps 10 ps 34 ps 75 ps 75 ps Scope BW 600 MHz 600 MHz 1 GHz 2.5 GHz 12 GHz 25 GHz 2 GHz 4 GHz 8 GHz 12 GHz 16 GHz 12 GHz 16 GHz 16 GHz 30 GHz 30 GHz 8 GHz 13 GHz 12 GHz 25 GHz 12 GHz 24 GHz 6 GHz 12.5 GHz 20 GHz 45 GHz 33 GHz 16 GHz 8 GHz 8 GHz 10 Gbps eye captured with 10 GHz of bandwidth. 10 Gbps eye captured with 20 GHz of bandwidth. 10 Gbps eye captured with 30 GHz of bandwidth. 10 Gbps signal captured with 63 GHz of bandwidth. Notice the faster rise time and wider eye measurements. 12 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve New Extremes Introducing Infiniium Z-Series oscilloscopes 63 GHz of true analog bandwidth and 160 GSa/s on two channels. See your signal more clearly with a large 15.4-inch capacitive touch-screen display. 16 GB RAM standard, quad core I5 processor and hardware acceleration enable fast processing. Remote access through Ethernet 10/100/1000BASE-T LAN interface with Web-enabled connectivity uses ultraresponsive UltraVNC. USB and LAN provide remote measurements. Infiniium application remote program interface (now a standard feature) allows application/compliance software automation. Calibration edge with a rise time of less than 15 ps enables TDT calibration with PrecisionProbe. Use the Infiniium calibration source as part of PrecisionProbe Advanced to extend calibration to an unmatched 63 GHz. Threaded RF connectors ensure the most reliable signal integrity for high-performance instruments. The AutoProbe II interface combines the tried-and-true 3.5-mm threaded RF connector of Keysight sampling oscilloscopes with a convenient automatic torque mechanism that ensures a consistent 8 in. lbs. connection without the hassles of a torque wrench. 13 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet 100-MHz reference clock ties up to 10 Z-Series together with 150 fs precision. A 10-MHz clock allows tying multiple instruments together with the Z-Series. Live indicator shows when the scope is running a long operation. Measure section, including a toggling marker button and a dedicated marker knob, provides quick access to your marker control. Individual vertical knobs per channel. The horizontal and vertical knobs can be changed to control functions and waveform memories. Simply right click the channel control in the GUI to change these controls. The Z-Series improves upon Keysight’s use of custom integrated circuits and multichip module packaging with an exclusive technology called RealEdge. RealEdge comprises a combination of new architectures, nextgeneration microcircuits and thin-film components, and advanced application of Keysight’s indium phosphide semiconductor process. This technology enables high-frequency capability while maintaining the industry’s lowest noise and jitter measurement floor (75 fs). 14 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve New Extremes (Continued) Infiniium User Interface Easy-to-use FFTs. Amplitude demodulation. Protocol decode. 15 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet The Infiniium user interface features: –– Full offline viewer –– Up to 4 grids –– Up to 16 functions –– Up to 16 horizontal gates –– Up to 9 jitter analysis charts –– Up to 9 noise analysis charts –– Up to 4 InfiniiSim charts –– Up to 16 FFTs at once –– Up to 16 grids in each window –– Peak annotation –– Composite files for easy file sharing –– On-screen marker measurements –– Up to 20 measurements displayed at once –– Multiple display support –– Drag and drop measurements –– My Infiniium menu customization –– Up to 16 user-defined functions –– Full spectral window –– Spectral analysis controls –– Quick save –– Multi-touch for touch capacitive screen –– Function overviews/window –– Up to 16 measurement trends –– Up to 16 histograms –– Nearly unlimited real-time eyes –– Tail fit versus spectral analysis chart –– Hardware acceleration –– Plus much more Up to 16 horizontal gates. Jitter algorithm verifying window. 16 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve New Extremes (Continued) Low noise and jitter The Z-Series features the industry’s lowest noise and jitter measurement floors, allowing you to truly see your signal and get your device to market faster. PrecisionProbe By characterizing and compensating for loss in cables, you can gain significant margin. PrecisionProbe makes using switches easy in your test setup. Waveform transformation Debugging next-generation buses such as PCI Express and Thunderbolt require advanced analysis tools. Keysight’s InfiniiSim software helps you model the most difficult situations. Infiniium Z-Series oscilloscopes are the world’s only 4-channel, 33-GHz real-time oscilloscopes. Z-Series scopes are the only oscilloscopes that feature 30-GHz probes, making debugging your system easier and ensuring you aren’t missing valuable harmonic content. 17 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Compliance software Keysight’s compliance software packages are certified by experts and provide assurance that when you pass in-house, you will pass at your customer site as well. Protocol analysis Infiniium protocol tools simplify debugging your design. Infiniium scopes offer full protocol analysis for PCI Express Gen 1, 2, and 3. The 128b/130b decoding features a lister that makes alignment between the lister and analog channels simple. Advanced jitter and noise separation Z-Series oscilloscopes features application-specific software that allows you to gain the insight into your design that you need. Whether you are solving tough jitter or noise problems, removing loss due to cables or probes, or simply looking at protocol, the Z-Series has the tools to help you ensure you realize your best design. Infiniium’s new noise analysis tools allow you to analyze your data bus completely. 18 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: PrecisionProbe Basic and Advanced (N2809A and N2807B) Turn your Z-Series oscilloscope into a time-domain transmissometry (TDT). Quickly characterize and compensate any input into your scope. Now every probe and cable in the system can have the exact same response — probe to probe or cable to cable — without the inaccuracies that using one model can produce. You can properly characterize custom probes and remove unwanted responses. In addition to characterizing the cables, PrecisionProbe allows for immediate use on the same instrument. PrecisionProbe saves you time and money while increasing your measurement accuracy. PrecisionProbe technology turns your oscilloscope into the ultimate characterization tool. Not only can you do the normal waveform transformations such as de-embedding through InfiniiSim, PrecisionProbe allows quick characterization of your entire probe system (including cables and switches) without the need for extra equipment. PrecisionProbe takes advantage of the fast “cal output” signal built into the Z-Series to characterize and compensate insertion loss on the measurement system. When you combine InfiniiMax probes with switches between the amplifier and the probe head, PrecisionProbe allows for full correction and automation of each probe’s path. Full automation is then available to allow for quick swapping of the inputs via Infiniium’s compliance framework. For increased accuracy, purchase PrecisionProbe Advanced for faster edge speeds and true differential measurements. PrecisionProbe technology: –– Properly creates custom probe transfer function = VOut/VIn –– Properly characterizes probed system transfer function such that VOut/VIn = VOut/VSrc –– Removes unwanted S21 cable loss Every Z-Series oscilloscope has Keysight’s custom indium phosphide (InP) fast edge. PCI Express measurement comparisons Root complex device Eye height (mV) 2.5 GT/s 12 GHz 517.19 5 GT/s_12 GHz_3.5 dB 312.22 5 GT/s_12 GHz_6 dB 341.1 5 GT/s_16 GHz_3.5 dB 306.6 5 GT/s_16 GHz_6 dB 344.4 8 GT/s_12 GHz_P7 96.83 8 GT/s_12 GHz_P8 100.16 8 GT/s_16 GHz_P7 96.92 8 GT/s_16 GHz_P8 100.24 Eye height PrecisionProbe 553.94 348.19 376 348.33 374.41 103.09 108.33 106.01 108.24 Gain (%) 7.1 11.5 10.2 13.6 8.7 6.5 8.2 9.4 8.0 By characterizing and compensating for cable loss on the cable connected to the PCI Express test fixture, the designer was able to gain between 6.5 and 13.6% margin that would have been lost otherwise. 19 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: EZJIT, EZJIT Plus and SDA (Standard on DSA Models) Gain insight into the causes of signal jitter to ensure high reliability of your design With faster edge speeds and shrinking margins in today’s high-speed digital designs, insight into the causes of jitter has become critical for success. Using EZJIT and EZJIT Plus jitter analysis software the Z-Series oscilloscopes help you identify and quantify jitter margins that affect the reliability of your design. Time correlation of jitter to the real-time signal makes it easy to trace jitter components to their sources. Additional compliance views and a measurement setup wizard simplify and automate RJ/DJ separation for testing against industry standards. EZJIT Plus automatically detects embedded clock frequencies and repetitive data patterns on the oscilloscope inputs and calculates the level of data-dependent jitter (DDJ) that is contributed to the total jitter (TJ) PDF by each transition in the pattern, a feature not available on any other real-time oscilloscope today. Use EZJIT software to extract spread spectrum clocks. Measurement trends and jitter spectrum EZJIT’s simple tools help you quickly analyze the causes of jitter. Measurement trends allow you to see deeper views of factors affecting measurements. Jitter spectrum is a fast method to find the causes of jitter. Two ways to separate jitter EZJIT Plus comes with two ways to separate jitter: the spectral method and the emerging tail fit method. Both methods allow for simple separation of RJ and DJ, but the tail fit method provides proper jitter separation in the unique case of bounded uncorrelated jitter. Unique RJ/DJ threshold view Determine which algorithm fits your data best. EZJIT Plus also provides a unique threshold view of the jitter spectrum with the threshold drawn on the chart. The spectral view provides insight into the decision point of the separation and works with both narrow and wide spectral separation. Real-time eye and clock recovery Serial data analysis (SDA) software provides flexible clock recovery including 1st and 2nd-order PLL and constant algorithms. With a stable clock, you can look at real-time eyes of transition and non-transition bits. Z-Series scopes with SDA software also provide a new unique view of bits preceding an eye. Flexible charts EZJIT Plus displays up to 10 graphs with unique information. Use them all to maximize your jitter analysis. Jitter separation makes debugging your device easy. 20 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: EZJIT Complete (Standard on DSA Models) Discover signal anomalies to the noise of the waveform Noise analysis with EZJIT Complete software for insight into the sources of noise in the signal. More than your standard jitter package Key measurements To efficiently determine root cause for any type of signal degradation in the amplitude domain, you must first determine whether the problem is caused by random or deterministic sources. To help you accomplish this task, EZJIT Complete takes analysis techniques used in the time domain (jitter analysis) and extends them into the amplitude domain. With EZJIT Complete, Z-Series scopes offer the following unique measurements: More than just an eye contour EZJIT Complete is an in-depth view into impairments related to signal levels – either logic ones or logic zeroes – deviating from their ideal positions. Some tools simply provide a view of an eye contour, but provide no real measurement data other than nice graphics. EZJIT Complete uses separation techniques to allow each bit to be examined to determine correlated effects and to make multiple measurements on individual bits to determine uncorrelated effects. Use FFTs to analyze the frequency domain and extract random components. Dual-Dirac modeling techniques are also carried from the jitter domain and used in the interference domain. –– Total interference (TI) –– Deterministic interference (DI) –– Random noise (RN) –– Periodic interference (PI) –– Inter-symbol interference (ISI) –– RIN (dBm or dB/Hz) –– Q-factor 21 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: InfiniiSim (N5465A) The most advanced waveform transformation software helps you render waveforms anywhere in a digital serial data link InfiniiSim waveform transformation toolset provides the most flexible and accurate means to render waveforms anywhere in a digital serial data link. The highly configurable system modeling enables you to remove the deleterious effects of unwanted channel elements, simulate waveforms with channel models inserted, view waveforms in physically improbable locations, compensate for loading of probes and other circuit elements, and do so simply and quickly on your tool of choice, the Z-Series at up to 63 GHz of bandwidth. Circuit models to define your setup The InfiniiSim waveform transformation toolset provides a graphical user interface for you to define your system as you understand it and even make it arbitrarily complex. You do this by selecting topologies and defining circuit blocks. Model reflections With the InfiniiSim waveform transformation toolset, you can transform signals with confidence, whether you are inserting or removing channel elements or relocating the measurement plane. InfiniiSim’s advanced toolset lets you model up to 27 different elements at once and model the interaction between elements. Only toolsets with the ability to model more than one element will properly reflect a model including the oscilloscope’s input. The Z-Series scopes provide their own S11 parameter to allow modeling of their own input. InfiniiSim renders the waveform through hardware acceleration. Model your system with as much detail as you need InfiniiSim features the model setup that best matches your design. Whether it is a simple single-element model or an advanced general-purpose model with up to 27 elements in the link, you can perfectly model your design and simulate the exact probing point you want. InfiniiSim allows embedding and de-embedding of up to 27 different elements or S-parameter models at once to meet your most demanding requirements. 22 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: Serial Data Equalization (N5461A) Significantly reduce receiver errors by opening even tightly shut eyes through equalization emulation Serial data equalization for the Z-Series provides fast and accurate equalization using decision feedback equalization (DFE), feed-forward equalization (FFE), and continuous-time linear equalization (CTLE) modeling in real-time. Serial data equalization software allows you to input your own self-designated tap values to verify your design. If you prefer, the software will find the optimal tap values for you. CTLE allows DC gain and two-pole modeling. Analysis Tools: InfiniiScan (N5414B) Trigger on events that hardware triggers can’t handle InfiniiScan software allows you to use an oscilloscope to identify signal integrity issues that hardware triggering is unable to find in your electronic designs. This innovative software scans through thousands of acquired waveforms per second to help you isolate signal anomalies, saving you time and improving designs. Innovative triggers The zone qualify finder allows you to draw a “must intersect” or “must not intersect” zone on the oscilloscope screen to visually determine the event identify condition. If you can see the event of interest on the screen, you can create a trigger that will isolate it, saving significant time over some complicated hardware triggers. Other triggers include non-monotonic edge, measurement limit search, runt and pulse width. Draw zones on your screen for a unique triggering experience. 23 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: N8900A Infiniium Offline Oscilloscope Analysis Software View and analyze away from your oscilloscope and target system Ever wish you could do additional signal viewing and analysis away from your scope and target system? Now you can. Capture waveforms on your scope, save to a file, and recall into Keysight’s Infiniium Offline application. View and analyze anywhere your PC goes Take advantage of large high-resolution and multiple displays found in your office. Use familiar scope controls to quickly navigate and zoom in to any event of interest. Use auto measurements and functions for additional insight. Share scope measurements more easily across your team You can share entire data records instead of being limited exclusively to static screen shots. Infiniium Offline software works with all of Infiniium’s applications. Create more useful documentation Use features such as right-click cut-and-paste to move screen images between applications, without ever having to save the image to a file. Add up to 100 bookmark annotations and up to 20 simultaneous measurements. Need advanced analysis capability? Infiniium Offline includes a variety of upgrade options including serial decode upgrades for a variety of serial buses, jitter analysis, and serial data analysis. Use Infiniium Offline to find signal anomalies, such as power supply coupling. Peak search capability makes Infiniium Offline a frequency domain tool. 24 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Analysis Tools: User-Defined Function (N5430A) Combine Infiniium and MATLAB for even more analysis Enhance the Z-Series with a seamless gateway to powerful MATLAB analysis functionality. User-defined function software adds new analysis capabilities to the Z-Series, beyond traditional math/analysis features. Now you have the freedom to develop your own math functions or filters using MATLAB and its Signal Processing Toolbox. With a seamless integration to MATLAB, Infiniium oscilloscopes allow you to display your math and analysis functions live on the oscilloscope screen, just like any other scope’s standard functions. Analysis Tools: Complete List of Analysis Software Description EZJIT Complete jitter analysis EZJIT Plus jitter analysis EZJIT jitter analysis Frequency domain analysis High-speed SDA and clock recovery InfiniiScan software triggering InfiniiSim advanced signal de-embedding InfiniiSim basic signal de-embedding MATLAB - Basic digital analysis MATLAB - Standard digital analysis MultiScope software - combines two scopes 1 MultiScope software - combines up to five scopes 1 MultiScope software - combines up to ten scopes 1 Pulse Amplitude Modulation (PAM-4) analysis PrecisionProbe calibration 2 Serial data equalization User-defined function License type Fixed Factory-installed on new scope purchase or user-installed on existing scope N8823A-1FP N5400A-1FP E2681A-1FP N8832A-001 E2688A-1FP N5414B-1FP N5465A-1FP N5465A-3FP N8831A-001 N8831A-002 — — — N8827A-1FP N2809A-1FP N5461A-1FP N5430A-1FP Floating User-installed transportable license Server-based license N8823A-1TP N5400A-1TP E2681A-1TP — E2688A-1TP N5414B-1TP N5465A-1TP N5465A-3TP — — N8834A-ATP N8834A-BTP N8834A-CTP N8827A-1TP N2809A-1TP N5461A-1TP N5430A-1TP N5435A-067 N5435A-001 N5435A-002 — N5435A-003 N5435A-004 N5435A-027 N5435A-026 — — N5435A-085 N5435A-086 N5435A-090 N5435A-077 N5435A-044 N5435A-025 N5435A-005 1. Supports any combination of Infiniium oscilloscope models with software 5.50 and above. 2. Compliance software is not supported on DSAZ632A, DSOZ632A, DSAZ592A and DSOZ592A scope models. 25 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Compliance and Automated Testing Today’s demanding environment means you have much less time to understand the intricacies of the technologies you are testing. You also have less time to develop and test automation software that is designed to increase measurement throughput and decrease time to market. Compliance applications save you time and money with measurement automation built into the compliance application. No longer do valuable resources need to be exclusively tied to writing automation software. Instead they can be deployed to designing the next big project. Infiniium’s compliance applications are fully functional with design tools such as ADS. Imagine running your waveforms at design through the entire suite of compliance tests, giving more insight earlier than was previously possible. As the design moves to silicon and then to validation, the same suite of tests can be run live on your device. Compliance applications make testing to today’s technologies standards easy. Compliance applications that run on Z-Series oscilloscopes are certified to test to the exact specifications of each technology standard. If a test passes on the Z-Series scope in your lab, you can be assured that it will pass in test labs and at plug fests worldwide. Keysight experts on technology boards and industry standards committees help define compliance requirements. As a result, you can be sure that Z-Series oscilloscope tools deliver to critical specifications. Setup wizards combined with intelligent test filtering give you confidence you’re running the right tests. Comprehensive HTML reports with visual documentation and pass/fail results guarantee that critical information is retained on each test. Quick and easy automated switching Only Keysight’s Z-Series oscilloscopes feature compliance applications with both the user-defined application’s add-in capability and integrated PrecisionProbe compensation. Switch paths can vary in their characteristics and have unwanted loss. By enabling PrecisionProbe in its compliance applications, Z-Series scopes allows you to characterize and compensate for every path in the switch, making every path’s frequency response identical in both magnitude and phase. These tools makes switch automation quick and painless. The Z-Series and its compliance applications make automation more automated than ever. Your technicians no longer need to spend valuable time physically changing connections. The remote programming interface makes it easy to control automation applications via your PC. PrecisionProbe is fully integrated in Z-Series automation applications. 26 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Compliance and Automation Testing: User-Defined Application (N5467B) Custom automation for your Z-Series oscilloscope The user-defined application is the only fully customizable automated environment made for an oscilloscope by an oscilloscope designer. It provides full automation, including the ability to control other Keysight instruments, external applications such as MATLAB and your DUT software. Simplify your automation The user-defined application (UDA) makes automation simple. The application takes the Infiniium compliance application framework and gives you full access to its interface. UDA allows for automation testing in as little as one minute. Use UDA to control other Keysight instruments such as signal generators and network analyzers to create a full suite of measurements. Full measurement report Customize your own tests and requirements with user-defined application in the familiar Keysight framework. No automation would be complete without a simple-to-view and easy-to-understand report. UDA provides a full report of the pass/fail criteria you have provided. Add-in capability Ever wanted to add testing to your compliance applications? All Infiniium compliance applications support the industry’s most flexible testing mechanism with UDA add-in capability. Create the custom testing you need and then plug it into your compliance application to expand the application to your testing needs. UDA add-in capability is available only on Infiniium oscilloscopes. PrecisionProbe and switch compatibility UDA makes automation of switches in your system simple and accurate. Use PrecisionProbe to characterize the path of the switch and then let UDA’s unique GUI switch between every input in your switch system. Every input can look identical in its frequency response thanks to this advanced technology. Add a switch when testing your multi-lane signals to automate tedious test requirements. 27 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Compliance and Automation Testing: Switch Matrix Support Comprehensive testing, easily achieved Eliminate reconnections (reducing errors) Compliance applications on the Z-Series support a switch matrix, making testing simple by automating tests for each lane of a multi-lane bus. Typical testing requires reconnecting the oscilloscope each time you switch a lane, which causes wasted time and inaccuracies. The Z-Series solves this problem by supporting switch matrix through its compliance test. Simply connect the switch to the oscilloscope and all the lanes, and then click Run to complete full testing of your entire device. Maintain accuracy The framework fully supports Keysight’s PrecisionProbe software (N2809A) and InfiniiSim software (N5465A). This gives you the ability to characterize every switch path to the device under test (both magnitude and skew) and ensure that all of them maintain the same level of accuracy. Customize your testing Use the remote programming interface (standard feature on the Z-Series) and N5467A user-defined application for device control, instrument control and test customization. Software description DisplayPort switch matrix HDMI switch matrix MIPI D-PHY switch matrix MIPI M-PHY switch matrix PCIe® switch matrix Ethernet KR switch matrix QSFP+ switch matrix UDA switch matrix 100GBASE-CR10 switch matrix 100GBASE-KR4 switch matrix 100GBASE-CR4 switch matrix 10GBASE-T switch matrix 1. Model number Floating 2 Fixed 1 Node locked Transportable Server based U7232C-7FP U7232C-7TP N5435A-701 N5399C-7FP U7238C-7FP N5399C-7TP U7238C-7TP N5435A-702 N5435A-703 U7249C-7FP U7249C-7TP N5435A-704 N5393F-7FP N8814B-7FP N5393F-7TP N8814B-7TP N5435A-705 N5435A-706 N6468A-7FP N5467B-7FP N8828A-7FP N6468A-7TP N5467B-7TP N8828A-7TP N5435A-707 N5435A-708 N5435A-709 N8829A-7FP N5435A-710 N8829A-7TP N8830A-7FP N8830A-7TP N5430A-711 N5392A-7FP N5392A-7TP N5430A-712 Factory-installed on new scope purchase or user-installed on existing scope. 2. Must be user-installed. DUT Clock SMA probe head Ch1 L1 SMA probe head Ch2 L2 SMA probe head Ch3 L3 SMA probe head Ch4 Switch matrix Scope +3.3V Typical switch configuration for HDMI testing (now supported in the Z-Series). Skews between switch paths are easily maintained with Keysight’s unique software. 28 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Compliance and Automation Testing: Other Options on Z-Series Oscilloscopes In the previous pages we have highlighted a few of the key technologies that benefit from the industry’s only four-channel oscilloscope with more than 20 GHz bandwidth. The Z-Series offers over 20 compliance applications and the list continues to grow. All applications are fully compatible with InfiniiSim, PrecisionProbe and UDA’s unique add-in capability. Compliance test and validation software 1 Description BroadR-Reach DDR1 and LPDDR1 DDR2 and LPDDR2 DDR3 and LPDDR3 DDR4 and LPDDR4 DisplayPort 1.2 eDP 1.4 eMMC Ethernet + EEE 10/100/1000BASE-T Ethernet 10GBASE-T Ethernet 10GBASE-KR Ethernet 100GBASE-CR10 Ethernet 100GBASE-CR4 Ethernet 100GBASE-KR4 GDDR5 HDMI 2.0 MHL 3.0 MIPI D-PHY MIPI M-PHY MOST PCI Express Gen4 SAS-3 SATA Gen 3 SFP+ USB 2.0 USB 3.1 USB HSIC UHS-I UHS-II User-defined application Thunderbolt XAUI 1. License type Fixed Factory-installed on new scope purchase or userinstalled on existing scope N6467A-1FP U7233A-1FP N5413B-1FP U7231B-1FP N6462A-1FP U7232C-1FP N6469A-1FP N6465A-1FP N5392B-1FP U7236A-1FP N8814B-1FP N8828A-1FP N8830A-1FP N8829A-1FP U7245A-1FP N5399C-1FP N6460B-1FP U7238C-1FP U7249C-1FP N6466A-1FP N5393F-1FP N5412D-1FP N5411B-1FP N6468A-1FP N5416A-1FP U7243B-1FP U7248A-1FP U7246A-1FP N6461A-1FP N5467B-1FP N6463B-1FP N5431A-1FP Floating User-installed transportable license Server-based license N6467A-1TP U7233A-1TP N5413B-1TP U7231B-1TP N6462A-1TP U7232C-1TP N6469A-1TP N6465A-1TP N5392B-1TP U7236A-1TP N8814B-1TP N8828A-1FP N8830A-1FP N8829A-1FP U7245A-1TP N5399C-1TP N6460B-1TP U7238C-1TP U7249C-1TP N6466A-1TP N5393F-1TP N5412D-1TP N5411B-1TP N6468A-1TP N5416A-1TP U7243B-1TP U7248A-1TP U7246A-1TP N6461A-1TP N5467B-1TP N6463B-1TP N5431A-1TP N5435A-062 N5435A-021 N5435A-037 N5435A-053 N5435A-056 N5435A-041 N5435A-083 N5435A-061 N5435A-060 N5435A-023 N5435A-059 N5435A-078 N5435A-080 N5435A-079 — N5435A-070 N5435A-078 N5435A-022 N5435A-043 N5435A-068 N5435A-112 N5435A-073 N5435A-028 N5435A-074 N5435A-017 N5435A-075 N5435A-042 — N5435A-052 N5435A-058 N5435A-057 N5435A-018 Compliance software is not supported on DSAZ632A, DSOZ632A, DSAZ592A and DSOZ592A scope models. 29 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Protocol Analysis Z-Series oscilloscopes come with more than 15 protocol decoders, including the industry’s only 64/66 b decoder. The Z-Series protocol tools feature timecorrelated markers that let you easily move between the listing window and the waveform. Protocol tools can be used on up to four lanes simultaneously. These unique tools feature search and trigger capability that lets you scan through the waveform to find the trigger condition that interests you. Protocol tools are fully compatible with Infiniium’s serial data analysis and are available on the Infiniium offline tool. Z-Series decoding the PCI Express Gen 3 packets. 30 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Protocol Analysis (Continued) Protocol decode software Optional application description Protocol 8b/10b (generic) 64b/66b (10GBASE-KR) CAN/LIN/FlexRay/CAN-FD I2S protocol triggering and decode I²C/SPI 2 JTAG 2 MIPI CSI-3 MIPI DigRF® v4 MIPI D-PHY 2 MIPI LLI MIPI RFFE MIPI UFS MIPI UniPro SPMI protocol trigger and decode PCIe 1 and 2 PCIe 3 Generic Raw – NRZ protocol decode Generic Raw – PAM-4 protocol decode RS-232/UART SATA SSIC SVID 2 USB 2.0 USB 3.0 License type Fixed Factory-installed on new scope purchase or userinstalled on existing scope Floating User-installed transportable license Server-based license (N5435A option) —1 N8815A-1FP N8803C-1FP N8811A-1FP N5391A-1FP N8817A-1FP N8820A-1FP N8807A-1FP N8802A-1FP N8809A-1FP N8824A-1FP N8818A-1FP N8808A-1FP N8845A-1FP N5463A-1FP N8816A-1FP —1 —3 N5462A-1FP N8801A-1FP N8819A-1FP N8812A-1FP N5464A-1FP N8805A-1FP —1 N8815A-1TP N8803C-1TP N8811A-1TP N5391A-1TP N8817A-1TP N8820A-1TP N8807A-1TP N8802A-1TP N8809A-1TP N8824A-1TP N8818A-1TP N8808A-1TP N8845A-2FP N5463A-1TP N8816A-1TP —1 —3 N5462A-1TP N8801A-1TP N8819A-1TP N8812A-1TP N5464A-1TP N8805A-1TP —1 N5435A-045 N5435A-103 105 N5435A-006 N5435A-038 N5435A-065 N5435A-047 N5435A-036 N5435A-049 N5435A-072 N5435A-063 N5435A-048 N5435A-114 N5435A-032 N5435A-046 —1 —3 N5435A-031 N5435A-035 N5435A-064 N5435A-054 N5435A-034 N5435A-071 1. Standard on DSA models or with high-speed SDA option. 2. Compliance software is not supported on DSAZ632A, DSOZ632A, DSAZ592A, and DSOZ592A scope models. 3. Requires PAM-4 compliance app and SDA option (firmware 6.0 and up). 31 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve New Extremes Configure your high-performance real-time oscilloscope solution today Get the most out of your oscilloscope investment by choosing options and software to speed your most common tasks. Use option numbers when ordering at time of purchase. Use model numbers to add to an existing scope. 1. Choose your oscilloscope Oscilloscope DSOZ634A DSAZ634A DSOZ632A DSAZ632A DSOZ594A DSAZ594A DSOZ592A DSAZ592A DSOZ504A DSAZ504A DSOZ334A DSAZ334A DSOZ254A DSAZ254A DSOZ204A DSAZ204A 1. Description 63-GHz digital storage oscilloscope 63-GHz digital signal analyzer 1 63-GHz digital storage oscilloscope 63-GHz digital signal analyzer 1 59-GHz digital storage oscilloscope 59-GHz digital signal analyzer 1 59-GHz digital storage oscilloscope 59-GHz digital signal analyzer 1 50-GHz digital storage oscilloscope 50-GHz digital signal analyzer 1 33-GHz digital storage oscilloscope 33-GHz digital signal analyzer 1 25-GHz digital storage oscilloscope 25-GHz digital signal analyzer 1 20-GHz digital storage oscilloscope 20-GHz digital signal analyzer 1 DSA models come standard with 100 Mpts memory, EZJIT Complete and Serial Data Analysis software. All models come with a front cover, power cord, keyboard, mouse, 3.5 mm male-to-male calibration cable (54916-61626), 3.5 mm (male) to 2.4 mm (male) calibration cable (54932-61630), ESD strap, and (5) 3.5 mm female-to-female coax adapters (5061-5311). 50, 59, and 63 GHz models come with (2) additional 1.85 female-to-female adapters (54932-68712). All models come standard with removable SSD hard drive. Memory options Memory per scope channel 100 Mpts/ch memory 200 Mpts/ch memory 500 Mpts/ch memory 1 Gpt/ch memory 2 Gpts/ch memory Description ANSI Z540 compliant calibration ISO17025 calibration Performance verification de-skew fixture for InfiniiMax III probe Rack mount kit option Transit case Removable SSD with Windows 7 for Z-Series - 1 TB Removable SSD with Windows 7 for Z-Series - 500 GB 3 Optional synchronization port for 20, 25, 33 GHz models 2. Standard on DSA models. 3. 500G SSD standard on all models. Options (on new oscilloscope) DSOZ000-100 2 DSOZ000-200 DSOZ000-500 DSOZ000-01G DSOZ000-02G Options DSOZ000-A6J DSOZ000-1A7 — — — DSOZ000-801 — DSOZ000-601 Model number — — N5443A N2759A N2748A N2110A-01T N2110A-500 — 32 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve New Extremes (Continued) Configure your high-performance real-time oscilloscope solution today 2. Choose your probes and accessories Probe amplifier Description 30 GHz InfiniiMax III probe amplifier 25 GHz InfiniiMax III probe amplifier 20 GHz InfiniiMax III probe amplifier 16 GHz InfiniiMax III probe amplifier 20 GHz InfiniiMax III+ probe amplifier 1 16 GHz InfiniiMax III+ probe amplifier 1 13 GHz InfiniiMax III+ probe amplifier 1 8 GHz InfiniiMax III+ probe amplifier 1 Model number N2803A N2802A N2801A N2800A N7003A N7002A N7001A N7001A Probe head Description 16 GHz QuickTip probe head 2 QuickTip probe tip (set of 4) 2 16 GHz solder-in probe head 26 GHz solder-in probe head 2 28 GHz Zero Insertion Force (ZIF) probe head 200 Ω ZIF tip for high sensitivity 3 25 GHz PC board ZIF tip (for normal sensitivity) 30 GHz browser probe head Browser tip replacement (set of 4) 28 GHz 3.5 mm/2.92 mm/SMA probe head 2 Model number N2848A N2849A N5441A N2836A N5439A N5447A N2838A N5445A N5476A N5444A Probe adapter Description 30 GHz voltage termination adapter (50 Ω — 3.5 mm (f) to (m) connector) Performance verification and deskew fixture Precision BNC adapter (50 Ω — 3.5 mm (f) to precision BNC (f) connector) Sampling scope adapter (50 Ω — 3.5 mm (f) to (m) connector) High-impedance probe adapter (includes one N2873A passive probe) Model number N7010A N5443A N5442A N5477A N5449A For more information about Infiniium Oscilloscope Probes and Accessories - Data Sheet, view the Keysight publication number 5968-7141EN. For more information about InfiniiMax III/III+ Probing System - Data Sheet, view the Keysight publication number 5990-5653EN. 1. With InfiniiMode technology, allowing you to switch to differential, single-ended, and common mode without adjusting probe tip connections. 2. Probe head that supports InfiniiMode connections. 3. Compatible only with InfiniiMax III probe amplifier. 33 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Achieve New Extremes (Continued) 3. Upgrade your oscilloscope Model numbers N2764BU-025 N2764BU-033 N2764BU-050 N2764BU-059 N2764BU-062 N2764BU-162 Description Upgrades within the Z-Series family Bandwidth upgrade from 20 to 25 GHz Bandwidth upgrade from 25 to 33 GHz Bandwidth upgrade from 33 to 50 GHz Bandwidth upgrade from 50 to 59 GHz Bandwidth upgrade from 50 to 63 GHz Bandwidth upgrade from 59 to 63 GHz Note: All except 50 to 59 GHz and 50 to 63 GHz upgrades require return to Service Center but do not include Service Center costs. Calibration incurs additional charges. Model number to upgrade N2810A-100 N2810A-200 N2810A-500 N2810A-01G N2810A-02G Memory per scope channel existing oscilloscope (post-sale) Upgrade from 50 to 100 Mpts/channel Upgrade from 100 to 200 Mpts/channel Upgrade from 200 to 500 Mpts/channel Upgrade from 500 Mpts to 1 Gpts/channel Upgrade from 1 to 2 Gpts/channel Number of channels Model numbers N2128A Description Upgrades within the Z-Series family Number of channel upgrade from 1-channel to 2-channel 59 or 63 GHz and 2-channel to 4-channel 33 GHz Note: Only applies to Infiniium Z-Series models DSAZ632A, DSOZ632A, DSAZ592A, and DSOZ592A. No return to service center is required. Upgrade is software only. Multi-frame options Model numbers N2107A N2106A N2105A N2109AU Description Upgrades within the Z-Series family Infiniium Z-Series multi-frame expansion kit from five to six frames Infiniium Z-Series multi-frame expansion kit for adding one frame Infiniium Z-Series multi-frame base kit for stacking two frames Infiniium Z-Series sync port upgrade kit for 20 to 33 GHz models (> 33 GHz not needed) 34 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications Vertical Typical analog bandwidth (3 dB) Analog bandwidth (3 dB) * 1-channel sample rate 2-channel sample rate 4-channel sample rate Rise time/fall time 10 to 90% 4 20 to 80% 5 Input impedance 3 Sensitivity 2 Input coupling Vertical resolution 1 Channel to channel isolation (any two channels with equal V/div settings) DC gain accuracy * Maximum input voltage Offset range Offset accuracy * Dynamic range DC voltage measurement accuracy RMS noise floor (scope only) Volts/div 10 mV 50 mV 100 mV 1V Z204A Z254A Z334A Z504A Z592A Z594A Z632A Z634A 20 GHz 25 GHz 33 GHz 50 GHz 59 GHz 59 GHz 63 GHz 63 GHz 20 GHz 25 GHz 32 GHz 50 GHz 59 GHz 59 GHz 62 GHz 62 GHz 80 GSa/s 80 GSa/s 80 GSa/s 160 GSa/s 160 GSa/s 160 GSa/s 160 GSa/s 160 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s 160 GSa/s 80 GSa/s 160 GSa/s 80 GSa/s 160 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s — 80 GSa/s — 80 GSa/s Z204A Z254A Z334A Z504A Z592A Z594A Z632A Z634A 22.0 ps 17.6 ps 13.3 ps 8.8 ps 7.5 ps 7.5 ps 7.0 ps 7.0 ps 15.6 ps 12.4 ps 9.4 ps 6.2 ps 5.3 ps 5.3 ps 4.9 ps 4.9 ps 50 Ω, ± 3% 1 mV/div to 1 V/div DC 8 bits, ≥ 12 bits with averaging RealEdge (1.85 mm) channels DC to 40 GHz: 70 dB 40 GHz to BW: 60 dB Standard (3.5 mm) channels DC to BW: 70 dB ± 2% of full scale at full resolution channel scale (± 2.5% for 5 mV/div) ± 5 V for steady state and transient measurements Vertical sensitivity Available offset Available offset (oscilloscope with N7010A voltage termination adapter) 1 to 49 mV/div ± 0.4 V ±4V 50 to 79 mV/div ± 0.7 V ±4V 80 to 134 mV/div ± 1.2 V ±4V 135 to 239 mV/div ± 2.2 V ±4V 240 mV/div to 1 V/div ± 4.0 V ±4V ≤ 3.5 V: ± (2% of channel offset + 1% of full scale) + 1 mV > 3.5 V: ± (2% of channel offset + 1% of full scale) ± 4 div from center screen Dual cursor: ± [(DC gain accuracy) + (resolution)] Single cursor: ± [(DC gain accuracy) + (offset accuracy) + (resolution/2)] Z204A Z254A Z334A Z504A Z594A, Z592A Z634A, Z632A 0.41 mV (rms) 1.46 mV (rms) 2.90 mV (rms) 28.6 mV (rms) 0.48 mV (rms) 1.7 mV (rms) 3.3 mV (rms) 32.5 mV (rms) 0.60 mV (rms) 2.00 mV (rms) 3.90 mV (rms) 38.1 mV (rms) 0.90 mV (rms) 2.90 mV (rms) 5.70 mV (rms) 56.7 mV (rms) 0.96 mV (rms) 3.15 mV (rms) 6.2 mV (rms) 60 mV (rms) 1.0 mV (rms) 3.3 mV (rms) 6.4 mV (rms) 63 mV (rms) * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm up period, and ± 5 °C from annual calibration temperature. 1. 2. Vertical resolution for 8 bits = 0.4% of full scale, for 12 bits = 0.024% of full scale. Full scale is defined as 8 vertical divisions. Magnification is used below 7.5 mV/div. Below 7.5 mV/div, full-scale is defined as 60 mV/div. The major scale settings are 5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, and 1 V. Input impedance is valid when V/div scaling is adjusted to show all waveform vertical values within scope display. Rise time calculated by using 0.44/BW for (10 to 90%) rise time. Rise time calculated by using 0.31/BW for (20 to 80%) rise time. 3. 4. 5. 35 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Horizontal Horizontal system: Oscilloscope channels Main timebase range Main timebase delay range Reference position Zoom timebase range Time scale accuracy 1, 8 Oscilloscope channel de-skew range Intrinsic jitter 6 (Sample clock jitter) Inter-channel intrinsic jitter 3 Inter-channel skew drift 3, 7 Jitter measurement floor 2 –– Time interval error –– Period jitter –– Cycle-cycle/N-cycle jitter Inter-channel jitter measurement floor 2, 3, 5 1. 2. 3. 4. 5. 6. 7. 8. 2 ps/div to 200 s/div 0 s ± 200 s real time Continuously adjustable across horizontal display range 1 ps/div to current main time scale setting ± (0.1 ppm initial + 0.1 ppm/year aging) ± 1 ms range, 10 fs resolution Acquired time range or Internal reference External reference delta-time interval < 10 µs (1 µs/div) 50 fs rms 50 fs rms 75 fs rms 75 fs rms 100 µs (10 µs/div) 75 fs rms 75 fs rms 1 ms (100 µs/div) 100 fs rms 100 fs rms 10 ms (1 ms/div) 150 fs rms 125 fs rms 100 ms (10 ms/div) 200 fs rms 150 fs rms 1 s (100 ms/div) 150 fs rms < 50 fs rms < 50 fs rms (Z502A/Z592A/Z632A (Z204A/Z254A/Z334A) 2 2 Noise Floor + ( Intrinsic Jitter ) Slew Rate 2 2 Noise Floor 2 + ( Intrinsic Jitter ) Slew Rate 2 2 Noise Floor 3 + ( Intrinsic Jitter ) Slew Rate 2 2 Time Interval Time Interval Inter channel Error Edge1 + Error Edge 2 + ( ) ( ) Intrinsic Jitter 2 Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ± 5 °C from firmware calibration temperature. Sample rate at maximum. Noise and slew rate determined at fixed-voltage measurement threshold, near middle of signal. Displayed signal not vertically clipped. Slew rate of sine wave = (peak signal amplitude) • 2 • π • f, slew rate of fast step ~= (10 to 90% rise time). Intra-channel = both edges on the same channel, inter-channel = two edges on different channels. Time Interval Error(Edge1) = time-interval error measurement floor of first edge, Time Interval Error(Edge2) = time-interval error measurement floor of second edge. Reading is the displayed Delta Time Measurement Accuracy measurement value. Do not double the listed Time Scale Accuracy value in Delta Time Measurement Accuracy formula. Scope channels and signal interconnect de-skewed prior to measurement. External timebase reference values measured using a Wenzel 501-04608A 10 MHz reference. Intrinsic jitter value depends on acquisition time range for Time Interval Error formula and depends on delta-time between edges for all two-edge formulas. Skew between channels caused by ± 5 °C temperature change. Initial = immediately after factory or user calibration. 36 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Horizontal (Continued) Horizontal system: Oscilloscope channels (Continued) Delta time measurement accuracy 2, 3, 4, 5 –– Intra-channel –– No averaging Time Interval 2 ± 5 + Error (Edge1) –– 256 averages –– Inter-channel –– No averaging –– 256 averages 2. 3. 4. 5. 2 Time Interval Time Scale Delta Error Edge 2 + ( ) Accuracy Time 2 2 5 Time Interval Time Interval Time Scale Delta ± + + 16 Error (Edge1) Error (Edge 2) Accuracy Time 2 Time Interval 2 Time Interval 2 Inter channel 5 + + Error (Edge1) Error (Edge 2) Intrinsic Jitter ± Time Scale Delta Inter channel + Time + Skew Drift Accuracy 2 2 2 Time Interval Time Interval Inter channel 5 + + 16 Error (Edge1) Error (Edge 2) Intrinsic Jitter ± Time Scale Delta Inter channel + + Accuracy Time Skew Drift Sample rate at maximum. Noise and slew rate determined at fixed-voltage measurement threshold, near middle of signal. Displayed signal not vertically clipped. Slew rate of sine wave = (peak signal amplitude) • 2 • π • f, slew rate of fast step ~= (10 to 90% rise time). Intra-channel = both edges on the same channel, inter-channel = two edges on different channels. Time Interval Error(Edge1) = time-interval error measurement floor of first edge, Time Interval Error(Edge2) = time-interval error measurement floor of second edge. Reading is the displayed Delta Time Measurement Accuracy measurement value. Do not double the listed Time Scale Accuracy value in Delta Time Measurement Accuracy formula. Scope channels and signal interconnect de-skewed prior to measurement. 37 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Acquisition Maximum real-time sample rate 1 channels 2 channels 4 channels Memory depth per channel Z204A, Z254A, Z334A Z592A, Z632A 80 GSa/s 160 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s — 4 channels (Z204A, Z254A, Z334A, Z504A, Z594A, Z634A) and 2 channels (Z592A, Z632A) Z504A, Z594A, Z634A 160 GSa/s 160 GSa/s 80 GSa/s 2 channels (Z204A, Z254A, Z334A, Z504A, Z594A, Z634A) and 1 channel (Z592A, Z632A) 100 Mpts 200 Mpts (standard on DSA models) 400 Mpts 1 Gpt 1 Gpt 2 Gpts Standard 50 Mpts Option 100 100 Mpts (standard on DSA models) Option 200 200 Mpts Option 500 500 Mpts Option 01G 1 Gpt Option 02G 2 Gpts Maximum acquired time at highest real-time resolution Real-time resolution 80 GSa/s 160 GSa/s Resolution 12.5 ps 6.25 ps Standard (20 M) 0.25 ms 0.125 ms Option 50 M 0.625 ms 0.3125 ms Option 100 1.25 ms 0.625 ms Option 200 2.5 ms 1.25 ms Option 500 6.25 ms 3.125 ms Option 01G 12.5 ms 6.25 ms Option 02G 25 ms 12.5 ms Sampling modes Real-time Successive single shot acquisitions Real-time with averaging Selectable from 2 to 65534 (Up to 200,000 with function) Real-time with peak detect 80 GSa/s (Unavailable on RealEdge channels) Real-time with hi resolution Real-time boxcar averaging reduces random noise and increases resolution (unavailable on RealEdge channels) Equivalent time Resoution 338 fs Gaussian magnitude, linear phase Slower filter roll off while maintaining linear phase Roll mode Scrolls sequential waveform points across the display in a right-to-left rolling motion. Works at sample rates up to 10 MSa/s with a maximum record length of 40 Mpts Segmented memory Captures bursting signals at max sample rate without consuming memory during periods of inactivity Maximum time between triggers is 562,950 seconds Re-arm time: 2.5 µs Memory depth: 20 M 50 M 100 M 200 M 500 M 1G 2G Max # of segments: 4096 8192 16384 32768 65536 131072 131072 Filters Sin(x)/x Interpolation On/off selectable FIR digital filter (2x, 4x, 8x, 16x settings). Digital signal processing adds points between acquired data points to enhance measurement accuracy and waveform display 38 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Hardware trigger Sensitivity Edge trigger bandwidth (Ch1 to Ch4) Edge trigger bandwidth (AUX) Minimum pulse width trigger Hardware Software (InfiniiScan) Level range Internal Auxiliary Sweep modes Display jitter 2, 3, 4 (Trigger jitter) Trigger sources Trigger modes Edge Edge transition Edge then edge (Time) Edge then edge (Event) Glitch Pulse width Runt 1. Internal low: 2.0 div p-p 0 to 22 GHz Internal high: 0.3 div p-p 0 to 18 GHz, 1.0 div p-p 0 to 22 GHz > 20 GHz 400 MHz 250 ps 40 ps ± 4 div from center screen or ± 4 V, whichever is smaller ± 5 V, also limit input signal to ± 5 V Auto, triggered, single 170 fs rms Channel 1, Channel 2, Channel 3, Channel 4 Triggers on a specified slope (rising, falling or alternating between rising and falling) and voltage level on any channel or auxiliary trigger. Edge trigger bandwidth is > 20 GHz Trigger on rising or falling edges that cross two voltage levels in > or < the amount of time specified. Edge transition setting from 250 ps The trigger is qualified by an edge. After a specified time delay between 10 ns to 10 s, a rising or falling edge on any one selected input will generate the trigger The trigger is qualified by an edge. After a specified delay between 1 to 16,000,000 rising or falling edges, another rising or falling edge on any one selected input will generate the trigger Triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity. Triggers on glitches as narrow as 125 ps. Glitch range settings: < 250 ps to < 10 s Trigger on a pulse that is wider or narrower than the other pulses in your waveform by specifying a pulse width and a polarity. Triggers on pulse widths as narrow as 125 ps. Pulse width range settings 250 ps to 10 s. Trigger point can be “end of pulse” or “time out” Triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. Can be time qualified with minimum setting of 250 ps Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ± 5 °C from firmware calibration temperature. 2. Internal edge trigger mode with JitterFree correction. Value depends on scope settings and trigger signal characteristics, and is equal to Time Interval Error value expressed in the formula above using the minimum Time Scale Accuracy value. 3. Value shown represents typical Display jitter for DSOZ334A at 100 mV/div triggering on 500 mVpp 16 GHz sin wave signal. 4. Sample rate at maximum. Noise and slew rate determined at fixed-voltage trigger threshold, near middle of signal. Displayed signal not vertically clipped. 39 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Hardware trigger (Continued) Timeout Pattern/pulse range Trigger when a channel stays high, low, or unchanged for too long. Timeout setting: from 250 ps to 10 s Triggers when a specified logical combination of the channels is entered, exited, present for a specified period of time or is within a specified time range or times out. Each channel can have a value of High (H), Low (L) or Don’t care (X) State Pattern trigger clocked by the rising, falling or alternating between rising and falling edge of one channel Window Triggers on an event associated with a window defined by two-user adjustable thresholds. Event can be window “entered,” “exited,” “inside (time qualified),” or “outside (time qualified)” voltage range. Trigger point can be “cross window boundary” or “time out.” Time qualify range: from 250 ps to 10 s Video Triggers from negative sync composite video, field 1, field 2, or alternating fields for interlaced systems, any field, specific line, or any line for interlaced or non-interlaced systems. Supports NTSC, PAL-M (525/60), PAL, SECAM (625/50), EDTV (480p/60), EDTV (576p/50), HDTV (720p/60), HDTV (720p/50), HDTV (1080i/60), HDTV (1080i/50), HDTV (1080p/60), HDTV (1080p/50), HDTV (1080p/30), HDTV (1080p/25), HDTV (1080p/24), and user-defined formats Trigger sequences Three-stage trigger sequences including two-stage hardware (Find event (A) and Trigger event (B)) and one-stage InfiniiScan software trigger. Supports all hardware trigger modes except “edge then edge” and “video,” and all InfiniiScan software trigger modes. Supports “delay (by time)” and “reset (by time or event)” between two hardware sequences. The minimum latency between “find event (A)” and “trigger event (B)” is 3 ns Trigger qualification and qualifier Single or multiple channels may be logically qualified with any other trigger mode Trigger holdoff range 100 ns to 10 s Trigger actions Specify an action to occur and the frequency of the action when a trigger condition occurs. Actions include email on trigger and execute “multipurpose” user setting Software trigger (Requires N5414B InfiniiScan event identification software – Option 009) Trigger modes Zone qualify Software triggers on the user-defined zones on screen. Zones can be specified as either “must intersect” or “must not intersect.” Up to eight zones can be defined across multiple channels Generic serial Software triggers on NRZ-encoded data up to 8.0 Gbps, up to 80-bit pattern. Support multiple clock data recovery methods including constant frequency, 1st-order PLL, 2nd-order PLL, explicit clock, explicit 1st-order PLL, explicit 2nd-order PLL, Fibre Channel, FlexRay receiver, FlexRay transmitter (requires E2688A except for the constant frequency clock data recovery mode) Measurement limit Software triggers on the results of the measurement values. For example, when the “pulse width” measurement is turned on, InfiniiScan measurement software trigger triggers on a glitch as narrow as 40 ps. When the “time interval error (TIE)” is measured, InfiniiScan can trigger on a specific TIE value Non-monotonic edge Software triggers on the non-monotonic edge. The non-monotonic edge is specified by setting a hysteresis value Runt Software triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. Unlike hardware runt trigger, InfiniiScan runt trigger can be further qualified via a hysteresis value 40 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Hardware trigger (Continued) Maximum measurement update rate Measurement modes Waveform measurements Voltage Time Clock Data Mixed Frequency domain Level qualification Eye-diagram measurements Jitter analysis measurements Clock Data Statistics Histograms Source Orientation Measurements (available as a function) Mask testing Waveform math Number of functions Hardware accelerated math operations FFT Frequency range Frequency resolution Window modes > 50,000 measurement/sec (one measurement turned on) > 250,000 measurement/sec/measurement (ten measurements turned on) Standard, Measure all edges mode Peak to peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, preshoot, upper, middle, lower, Vovershoot, Vtime, Vpreshoot, crossing, pulse base, pulse amplitude, pulse top, PAM level mean 2, PAM level RMS 2, PAM level skew 2, PAM level thickness 2 Rise time, fall time, positive width, negative width, burst width, burst period, burst interval, Tmin, Tmax, Tvolt, + pulse count, - pulse count Period, frequency, duty cycle to duty cycle, phase, N-period Setup time, hold time Area, slew rate FFT frequency, FFT magnitude, FFT delta frequency, FFT delta magnitude, peak detect mode Any channels that are not involved in a measurement can be used to level-qualify all timing measurements Eye height, eye width, eye jitter, crossing percentage, Q factor, and duty-cycle distortion Requires Option 002 (or E2681A), 004 (N5400A), or 070 (N8823A). Standard on DSA Series Time interval error, N-period, period to period, positive width to positive width, neg width to neg width, and duty cycle to duty cycle Time interval error, unit interval, N Unit Interval, unit interval to unit interval, data rate, CDR, de-emphasis Displays the current, mean, minimum, maximum, range (max-min), standard deviation, number of measurements value for the displayed automatic measurements Waveform or measurement Vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defined using waveform markers Mean, standard deviation, mean ± 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total hits, peak (area of most hits), X scale hits, and X offset hits Allows pass/fail testing to user-defined or Keysight-supplied waveform templates. Automask lets you create a mask template from a captured waveform and define a tolerance range in time/voltage or screen divisions. Test modes (run until) include test forever, test to specified time or event limit, and stop on failure. Executes “multipurpose” user setting on failure “Unfold real-time eye” feature allows individual bit errors to be observed by unfolding a real-time eye when clock recovery is on Communications mask test kit option provides a set of ITU-T G.703, ANSI T1.102, and IEEE 802.3 industrystandard masks for compliance testing Sixteen Differential and Common Mode Absolute value, add, amplitude demodulation (radar envelope), average, Butterworth 1, common mode, delay, differentiate, divide, FFT magnitude, FFT, phase, FIR 1, high pass filter, histogram, horizontal gating, integrate, invert, LFE 1, low pass filter (4th-order Bessel Thompson filter), magnify, max, measurement trend, min, multiply, RT Eye 1, smoothing, SqrtSumOfSquare 1, square, square root, subtract, versus, and optional user defined function (Option 010) DC to 80 GHz (at 160 GSa/s) or 40 GHz (at 80 GSa/s) or 20 GHz (at 40 GSa/s) Sample rate/memory depth = resolution Hanning, flattop, rectangular, Blackman-Harris, Hamming 1. Requires EZJIT Plus (Option N5400A) or EZJIT Complete (Option N8823A) software. 2. Requires PAM-4 analysis (Option N8827A) software. 41 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) Hardware trigger (Continued) Measurement modes Automatic measurements Multipurpose Drag-and-drop measurement toolbar Marker modes Bookmarks and callouts Display Display Intensity grayscale Resolution XGA Annotation Grids Waveform styles Measure menu access to all measurements, up to 20 measurements can be displayed simultaneously Front-panel button activates up to ten pre-selected or up to ten user-defined automatic measurements Measurement toolbar with common measurement icons that can be dragged and dropped onto the displayed waveforms Manual markers, track waveform data, track measurements Supports callouts for measurements and FFT peaks. Supports bookmarks for team collaboration 15.4-inch color XGA TFT-LCD with capacitive touch screen 256-level intensity-graded display 1024 pixels horizontally x 768 pixels vertically Up to 100 bookmarks can be inserted into the waveform window. Each can float or be tied to a specific waveform Choose between 1-16 grids per waveform area, 8 bit vertical resolution Connected dots, dots, infinite persistence, color graded infinite persistence. Includes up to 256 levels of intensitygraded waveforms., variable persistence Waveform area Supports eight waveform areas plus chart mode for EZJIT Plus, InfiniiSim, protocol, and PrecisionProbe Maximum update rate > 400,000 waveforms per second (when in the segment memory mode) Computer system and peripherals, I/O ports Computer system and peripherals Operating system Windows 7 64-bit CPU Intel i5-3550S quad-core CPU at 3.00 GHz PC system memory 16 GB DDR3 RAM Drives (SSD) 500-GB internal hard drive removable hard drive, additional hard drives (N2110A) Peripherals Logitech optical USB mouse, compact USB keyboard supplied. All Infiniium models support any Windowscompatible input device with a serial, PS/2 or USB interface. File types Waveforms Compressed internal format (*.wfm (200 Mpts)), comma-separated values (*.csv (2 Gpts)), tab-separated values (*.tsv (2 Gpts)), public binary format (.bin (500 Mpts)), Y value files (*.txt (2 Gpts)), hierarchal data file (*.hf5 (2 Gpts)), composite data file (*.osc (2 Gpts)) Images BMP, PNG, TIFF, GIF, JPEG or osc file format I/O ports RS-232 (serial), parallel, PS/2, USB 2.0 hi-speed (host), USB 2.0 hi-speed (device), VGA, DisplayPort, USB 3.0, dual-monitor video output, auxiliary output, trigger output, time base reference output 42 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Specifications (Continued) General characteristics Temperature Humidity Altitude Vibration Power Weight Dimensions Safety Operating: 5 to + 40 °C; Non-operating: –40 to +65 °C Operating: Up to 95% relative humidity (non-condensing) at +40 °C Non-operating: Up to 90% relative humidity at +65 °C Operating: Up to 4,000 meters (12,000 feet); Non-operating: Up to 15,300 meters (50,000 feet) Operating random: 00.21 g (rms) Non-operating random: 2.0 g (rms) Swept sines: (0.50 g) 100 to 240 VAC ± 10% at 50/60 Hz Maximum input power 1350 W Well-regulated power is required for 100 to 120 VAC operation 32.2 kg (71 lbs) Height: 33.8 cm (13.3 in); Width: 50.8 cm (20 in); Depth: 49.3 cm (19.4 in) CAN/CSA-C22.2 No. 61010-1-04 UL Std. No. 61010-1 (2nd Edition) Keysight Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications 43 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. The business that became Keysight was a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. The business that became Keysight was a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Download your next insight Keysight software is downloadable expertise. From first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. –– Electronic design automation (EDA) software –– Application software –– Programming environments –– Productivity software Learn more at www.keysight.com/find/software Start with a 30-day free trial. www.keysight.com/find/free_trials 44 | Keysight | Infiniium Z-Series Oscilloscopes - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—one-stop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-6-20-17) MIPI® service marks and logo marks are owned by MIPI Alliance, Inc. and any use of such marks by Keysight Technologies is under license. Other service marks and trade names are those of their respective owners. DEKRA Certified PCI-SIG®, PCIe® and the PCI Express® are US registered trademarks and/or service marks of PCI-SIG. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System www.keysight.com/find/Z-Series ISO9001 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2013 - 2017 Published in USA, July 17, 2017 5991-3868EN www.keysight.com