ACM18 Series AC-DC Power Supplies 18 Watt xxx Series • Energy Efficiency Level VI • European CoC Tier 2 • Medical and ITE Approvals • Interchangeable Mains Connectors • Optional White Versions • Output Voltages from 5 V to 24 V • Class II Construction • 3 Years Warranty The ACM18 series of wall plug adaptors comply with the latest energy efficiency level VI standards with high active mode efficiency and extremely low no load power consumption. Available with a standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and medical applications while maintaining industry leading performance. Dimensions: ACM (body only): 3.46 x 1.18 x 1.95” (88.0 x 30.0 x 49.5 mm) Models & Ratings Output Power 18 W Output Voltage Output Current Total Regulation(3) Efficiency(4) Model Number(1,2,5) 5.0 V 9.0 V 2500 mA 2000 mA 5% 5% 82.5% 86.7% ACM18US05 ACM18US09 12.0 V 1500 mA 5% 87.5% ACM18US12 15.0 V 1250 mA 5% 87.5% ACM18US15 18.0 V 1000 mA 5% 87.5% ACM18US18 24.0 V 750 mA 5% 87.5% ACM18US24 Notes 1. Model number is for body only. AC input plugs must be ordered separately, see AC input plug section. 2. Other output voltages available, contact sales for details. 3. Total regulation includes initial set accuracy, line and load regulation. 4. Typical average value measured at 115 VAC. 5. For white case version add suffix ‘-W’ e.g. ACM18US12-W. MOQ applies, contact sales for details. Input Characteristic Input Voltage Input Frequency Input Current Inrush Current Power Factor No Load Input Power Input Protection Minimum 90 47 Typical Maximum 264 63 0.23 70 Units VAC Hz A A 75 mW Maximum 24 5 Units V A s ms ms % 4 % deviation Ripple & Noise 150 mV pk-pk Short Circuit Protection Temperature Coefficient 0.05 %/ ˚C Notes & Conditions 100 VAC 240 VAC, cold start at 25 °C EN61000-3-2, class A Internal fuse in both line and neutral Output Characteristic Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Total Regulation Transient Response 1 Minimum 5 0 Typical 4 30 10 Notes & Conditions See Models and Ratings table No minimum load required Full load and 100 VAC See Models and Ratings table Recovery within <1% within 500 µs for a 60% step load change at 0.15 A/µs Measured with 20 MHz bandwidth and 10 µF electrolytic in parallel with 0.1 µF ceramic capacitor Continuous, trip and restart (hiccup mode) with auto recovery www.xppower.com ACM18 Series AC-DC Power Supplies General Characteristic Minimum Typical Efficiency Maximum Notes & Conditions Units Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 115 VAC input % 87 Energy Efficiency Level VI 4000 Isolation Leakage Current 30 Switching Frequency 24 Mean Time Between Failure 250 Input to Output kHz kHrs At 264 VAC, 60 Hz, from output to ground lb (g) Body only µA 100 70 0.18 (80) Weight VAC Variable MIL-HDBK-217F at 25 °C GB Environmental Characteristic Minimum Maximum Units 0 +60 °C Storage Temperature -20 +85 °C Operating Humidity 5 90 % 5000 m Operating Temperature Typical Operating Altitude Notes & Conditions Derate from 100% load at 40 °C to 50% load at 60 °C RH, non-condensing Cooling Natural convection Shock 1 m drop onto concrete on each of 6 axes, non operating 10 Vibration Hz 300 2 g, 0.3 decades/min, 15 mins for each of 3 axes EMC: Emissions Phenomenon Standard Test Level Conducted EN55022 Level B Radiated EN55022 Level B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 Notes & Conditions EMC: Immunity Phenomenon Medical Device EMC Low Voltage PSU EMC Standard Test Level Criteria IEC60601-1-2 Ed.4.0 : 2014 as below as below EN61204-3 High severity level ESD Immunity EN61000-4-2 ±8 kV contact, ±15 kV air A Radiated Immunity EN61000-4-3 10 V/m A A EFT/Burst EN61000-4-4 Level 3 Surge EN61000-4-5 Level 3 A Conducted Immunity EN61000-4-6 6V A Magnetic Fields EN61000-4-8 30 A/m Dip: 100% 10 ms Dip: 70% 500 ms A A B Int: 100% 5000 ms B Dip: 30% 25 AC Cycles A EN61000-4-11 Dips and Interruptions EN60601-1-2 Int: 100% 0.5 AC Cycle A Int: 100% 1 AC Cycle A Int.: >95% 5000 ms B Notes & Conditions High Line/Low Line At 8 angles Safety Approvals Safety Agency UL Safety Standard Notes & Conditions UL60950-1 TUV EN60950-1 CB IEC60950-1 CE LVD UL ANSI/AAMI ES 60601-1 CSA CSA C22.2 No. 60601 TUV EN60601-1 CB IEC60601-1 Information Technology Medical www.xppower.com 2 ACM18 Series AC-DC Power Supplies Mechanical Details ACM18USXX 1.94 (49.5) ±0.01 (±0.5) 3.46 (88.0) ±0.01 (±0.5) 70.8 (1800.0) ±10% 0.43 (11.0) ±0.01 (±0.5) 1.18 (30.0) ±0.01 (±0.5) ø0.09 (ø2.5) ø0.21 (ø5.5) AC Input Plugs Black UK Plug: ACM PLUG UK White UK Plug: ACM PLUG UK W Black USA Plug: ACM PLUG US White USA Plug: ACM PLUG US W 1.73 (44.1) ±0.02 (±0.6) 1.25 (32.0) ±0.11 (±0.5) 1 R3 0.15 (3.97) ±0.1 (±0.15) 1.16 (29.5) ±0.11 (±0.5) 1.94 (49.4) ±0.02 (±0.6) 0.05 (1.5) ±0.003 (±0.1) R3 0.87 (22.2) ±0.1 (±0.15) 0.62 (16.0) ±0.01 (±0.5) 0.24 (6.3) ±0.003 (±0.1) 0.35 (9.0) ±0.11 (±0.5) 0.27 (7.0) ±0.007 (±0.2) 0.5 (12.7) ±0.007 (±0.2) 0.89 (22.7) ±0.01 (±0.5) 0.69 (17.7) ±0.01 (±0.5) 0.03 (4.0) ±0.003 (±0.1) 1.26 (22.25) ±0.007 (±0.2) 0.31 (7.9) ±0.003 (±0.1) 0 1 3 www.xppower.com 0.66 (17.0) ±0.11 (±0.5) ACM18 Series DC-DC Converter AC Input Plugs Black Australian Plug: ACM PLUG AU White Australian Plug: ACM PLUG AU W Black European Plug: ACM PLUG EU White European Plug: ACM PLUG EU W 0.35 (9.0) ±0.01 (±0.3) R 0.8 (20.5) 1.16 (29.5) ±0.02 (±0.6) 1.16 (29.5) ±0.02 (±0.6) 1 0.06 (1.6) ±0.1 (±0.003) 1.25 (32.0) ±0.02 (±0.6) 1.26 (32.1) ±0.02 (±0.6) 0.24 (6.3) ±0.1 (±0.003) 0.7 (17.8) ±0.02 (±0.6) 0 0.34 (8.8) ±0.1 (±0.003) 1.40 (35.6) ±0.01 (±0.6) 0.71 (18.2) ±0.01 (±0.5) 0.35 (9.0) ±0.01 (±0.5) 1.16 (29.5) ±0.01 (±0.6) 0.6 (17.0) 0.69 (17.6) ±0.007 (±0.2) 0.55 (14.1) ±0.01 (±0.5) 0.74 (19.0) ±0.01 (±0.5) 1.61 (41.0) ±0.02 (±0.6) Black China Plug: ACM PLUG CN White China Plug: ACM PLUG CN W 1.16 (29.5) ±0.01 (±0.5) 0.35 (9.0) ±0.01 (±0.5) 1.25 (32.0) ±0.01 (±0.5) 0.62 (16.0) ±0.01 (±0.5) 0.24 (6.3) ±0.003 (±0.1) 0.05 (1.5) ±0.003 (±0.1) 0.5 (12.7) ±0.007 (±0.2) www.xppower.com 08 Aug 16