Vitec ILPA75VU-S048ST 75w water-proof constant voltage led driver Datasheet

ILPA75VU SERIES
75W Water-Proof Constant Voltage LED Driver
–
–
–
–
–
–
–
3 Year Warranty
Wide Input Voltage 90 to 305VAC, 47 to 63Hz
Constant Output Voltage Available From 12VDC Thru 105VDC
Over Voltage, Over Current, Short Circuit, Lighting, and Over Temperature Protection
High Efficiency (up to 93%)
Active Power Factor Correction (PFC) (99% typical)
IP67 Waterproof Rating, Metal Housing
Comply with UL8750 & EN61347 Safety Regulation (Pending)
Approvals:
Single Output
Part Number
Output Voltage
ILPA75VU-S012ST
ILPA75VU-S024ST
ILPA75VU-S036ST
ILPA75VU-S042ST
ILPA75VU-S048ST
ILPA75VU-S054ST
ILPA75VU-S081ST
ILPA75VU-S105ST
12 VDC
24 VDC
36 VDC
42 VDC
48 VDC
54 VDC
81 VDC
105 VDC
Max.
Output Current
6.25 A
3.13 A
2.08 A
1.79 A
1.56 A
1.39 A
0.93 A
0.71 A
Efficiency
(220VAC, Full Load)
91%
92%
92%
92%
92%
93%
93%
93%
Over Voltage
Protection
16V
33V
45V
50V
58V
63V
90V
120V
Max.
Output Power
75W
75W
75W
75W
75W
75W
75W
75W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Test Conditions
Operating Voltage
Min.
90
47
0
Typ.
Max.
305
63
75
0.9
0.45
50
Unit
VAC
Hz
W
A
A
A
%
%
%
W
%
%
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Vin=110VAC
99
Vin=220VAC
95
Io=Full Load, Vin=230VAC
93
No Load, VIn=230VAC
1.5
Io=Full Load
1
Vin=230VAC
2
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
135
% Io
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
3
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
2
% Vo
uF electrolytic capacitor.
Conditions
Parameter
Test Conditions
Operating Temperature
Storage Temperature
Relative Humidity
Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
No output power derating from -35°C to 70°C
Min.
-35
-40
5
0.45M
0.1M
Typ.
Max.
70
85
95
Unit
°C
°C
%
Hours
Hours
Approvals and Compliance
Parameter
EMI
EMS
Safety UL/c-UL, T-mark, CE
Environmental Compliance
Waterproof
Standards
EN55015
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-1-1, EN61547
UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2
No.250.0, EN61347-1,EN61347-2-13
RoHS
IP67 Rating
Mechanical
Parameter
Dimension, Net Weight
Input Electric Wire
Output Electric Wire
Specification
184x67.5x37mm (7.24x2.66x1.46 inches), 950g approx.
650mm, Black(ACL), White(ACN), Green(GND)
220mm, Red(V+), Black(V-)
Similar pages