Power Cord Specifications: Cable Length - Metric Connector Type A Connector Type B Jacket Colour Shielding Material Insulation(Single or Double) Insulation Material Conductor Type Number of Conductors Conductor Size Conductor Construction Cord Jacket Diameter Voltage Rating Current Rating Temperature Rating : 1.8m : IEC 60320 C13 : IEC 60320 C14 : Black : PVC : Single : PVC : Annealed soft bara Copper Wire :3 : 0.75mm2 : 24/0.2 : 6.8 ±0.2 : 250V : 10A : 75°C Dimensions : Millimetres Notes: 1. Cable : The cord shall comply with IEC 60227 and UL62 2. Plug : The molded plug shall comply with IEC 60320-1 standard sheet C14, UL817 and CSA22.2 3. Connector : The molded connector shall comply with IEC 60320-1 standards (C13 Connector) 3. The product shall be tested 100% for all safety electrical items. Part Number Table Description Part Number IEC 60320 C13 to IEC 60320 C14, 1.8m GW-151643 Important Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. pro - POWER is the registered trademark of the Group. © Premier Farnell plc 2012. www.element14.com www.farnell.com www.newark.com www.cpc.co.uk Page <1> 15/12/15 V1.2