TDK CU4S0506BC-763-00 Circulator Datasheet

R F
C o m p o n e n t s
October 2015
Circulator
SMD
CU4S0506 Series
5x5mm*
* Dimensions Code JIS
RF Components
Circulator
Product compatible with RoHS directive
SMD
Overview of CU4S0506 Series
PART NUMBER CONSTRUCTION
CU4S0506
□
Series name
Direction
A
B
CW
CCW
C
-
○○○○
Center Frequency
(MHz)
△△
Control Number
cut off after the decimal point
DIRECTION OF CIRCULATION
ClockWise(CW): A
CounterClockWise(CCW): B
50Ω Load
50Ω Load
OUT
-
IN
IN
OUT
TEMPERATURE RANGE
Operating temperature
(°C)
–35 to +85
Storage temperature
(°C)
–40 to +85
RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20151001 / rf_circulator_cu4s0506_en.fm
RF Components
CU4S0506 Series
SHAPES AND DIMENSIONS
2.0±0.2
(3)
(4)
(2)
(5)
(1)
(6)
5.0±0.3
5.0±0.3
[Top view]
Terminal (Au plating)
Metal parts other than a terminal.
(GND electric potential)
Tolerance unless otherwise specified: ±0.2
Coplanarity : 0.1max.
5.2±0.3
[Bottom view]
3.0
IN
GROUND
50Ω Load
GROUND
GROUND
OUT
Counter
Clockwise
0.8
1.6
0.8
1.6
0.8
Terminal functions
1
OUT
2
GROUND
50Ω Load
3
GROUND
4
5
GROUND
6
IN
Rotation Clockwise
Dimensions in mm
0.4
[Marking]
0.4
ClockWise(CW): A
CounterClockWise(CCW): B
(3)
(4)
(3)
(4)
(2)
(5)
(2)
(5)
(1)
(6)
(1)
(6)
Marking
Marking
RECOMMENDED LAND PATTERN
RECOMMENDED PC BOARD PATTERN
GND
Circulator Outline
1.1
Dimensions in mm
I/O
0.6min.
4.2
Connect to
50Ω Stripline
With I/O land.
(1.0)
1.0
1.1
I/O
1.6
1.6
1.0
1.6
0.6min.
1.0
4.2
I/O
(1.1) 1min.
Dimensions in mm
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20151001 / rf_circulator_cu4s0506_en.fm
RF Components
CU4S0506 Series
ELECTRICAL CHARACTERISTICS
Frequency
range
Center
frequency
Isolation
Insertion
loss
V.S.W.R.
Zo=50:
Handling
power
(MHz)
(MHz)
(dB)
min.
12
12
12
12
12
12
12
13
13
12
13
12
13
11
14
14
11
12
12
14
11
14
14
11
12
12
14
12
13
12
13
12
12
12
12
13
15
13
15
14
14
15
14
14
14
15
14
15
13
15
13
12
13
13
(dB)
max.
1.15
1.15
1.15
1.20
1.20
1.15
1.15
0.90
0.90
1.20
0.90
1.20
0.90
1.20
0.80
0.80
1.20
0.95
0.95
0.80
1.20
0.80
0.80
1.20
0.95
0.95
0.80
0.95
0.80
0.95
0.80
0.95
0.95
0.95
0.95
0.80
0.60
0.75
0.60
0.70
0.70
0.70
0.70
0.70
0.70
0.60
0.70
0.60
0.70
0.60
0.75
0.90
0.75
0.75
max.
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.7
1.6
1.7
1.6
1.8
1.6
1.6
1.8
1.7
1.7
1.6
1.8
1.6
1.6
1.8
1.7
1.7
1.6
1.7
1.6
1.7
1.6
1.7
1.7
1.7
1.7
1.6
1.5
1.6
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.5
1.6
1.6
1.6
1.6
(W)
max.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
699 to 716
704 to 716
716 to 728
703 to 748
718 to 748
729 to 746
734 to 746
746 to 756
758 to 768
758 to 803
777 to 787
773 to 803
788 to 798
791 to 821
807 to 824
815 to 830
815 to 845
814 to 849
824 to 849
830 to 845
832 to 862
852 to 869
860 to 875
860 to 890
859 to 894
869 to 894
875 to 890
880 to 915
900 to 915
925 to 960
945 to 960
1427.9 to 1462.9
1475.9 to 1510.9
1525 to 1559
1626.5 to 1660.5
1710 to 1785
1749.9 to 1784.9
1805 to 1880
1844.9 to 1879.9
1850 to 1910
1850 to 1915
1880 to 1920
1920 to 1980
1930 to 1990
1930 to 1995
2010 to 2025
2110 to 2170
2305 to 2315
2300 to 2400
2350 to 2360
2500 to 2570
2496 to 2690
2570 to 2620
2620 to 2690
707.5
710
722
725.5
733
737.5
740
751
763
780.5
782
788
793
806
815.5
822.5
830
831.5
836.5
837.5
847
860.5
867.5
875
876.5
881.5
882.5
897.5
907.5
942.5
952.5
1445.4
1493.4
1542
1643.5
1747.5
1767.4
1842.5
1862.4
1880
1882.5
1900
1950
1960
1962.5
2017.5
2140
2310
2350
2355
2535
2593
2595
2655
Part Number
ClockWise
CU4S0506AC-707-00
CU4S0506AC-710-00
CU4S0506AC-722-00
CU4S0506AC-725-00
CU4S0506AC-733-00
CU4S0506AC-737-00
CU4S0506AC-740-00
CU4S0506AC-751-00
CU4S0506AC-763-00
CU4S0506AC-780-00
CU4S0506AC-782-00
CU4S0506AC-788-00
CU4S0506AC-793-00
CU4S0506AC-806-00
CU4S0506AC-815-00
CU4S0506AC-822-00
CU4S0506AC-830-00
CU4S0506AC-831-00
CU4S0506AC-836-00
CU4S0506AC-837-00
CU4S0506AC-847-00
CU4S0506AC-860-00
CU4S0506AC-867-00
CU4S0506AC-875-00
CU4S0506AC-876-00
CU4S0506AC-881-00
CU4S0506AC-882-00
CU4S0506AC-897-00
CU4S0506AC-907-00
CU4S0506AC-942-00
CU4S0506AC-952-00
CU4S0506AC-1445-00
CU4S0506AC-1493-00
CU4S0506AC-1542-00
CU4S0506AC-1643-00
CU4S0506AC-1747-00
CU4S0506AC-1767-00
CU4S0506AC-1842-00
CU4S0506AC-1862-00
CU4S0506AC-1880-00
CU4S0506AC-1882-00
CU4S0506AC-1900-00
CU4S0506AC-1950-00
CU4S0506AC-1960-00
CU4S0506AC-1962-00
CU4S0506AC-2017-00
CU4S0506AC-2140-00
CU4S0506AC-2310-00
CU4S0506AC-2350-00
CU4S0506AC-2355-00
CU4S0506AC-2535-00
CU4S0506AC-2593-00
CU4S0506AC-2595-00
CU4S0506AC-2655-00
CounterClockWise
CU4S0506BC-707-00
CU4S0506BC-710-00
CU4S0506BC-722-00
CU4S0506BC-725-00
CU4S0506BC-733-00
CU4S0506BC-737-00
CU4S0506BC-740-00
CU4S0506BC-751-00
CU4S0506BC-763-00
CU4S0506BC-780-00
CU4S0506BC-782-00
CU4S0506BC-788-00
CU4S0506BC-793-00
CU4S0506BC-806-00
CU4S0506BC-815-00
CU4S0506BC-822-00
CU4S0506BC-830-00
CU4S0506BC-831-00
CU4S0506BC-836-00
CU4S0506BC-837-00
CU4S0506BC-847-00
CU4S0506BC-860-00
CU4S0506BC-867-00
CU4S0506BC-875-00
CU4S0506BC-876-00
CU4S0506BC-881-00
CU4S0506BC-882-00
CU4S0506BC-897-00
CU4S0506BC-907-00
CU4S0506BC-942-00
CU4S0506BC-952-00
CU4S0506BC-1445-00
CU4S0506BC-1493-00
CU4S0506BC-1542-00
CU4S0506BC-1643-00
CU4S0506BC-1747-00
CU4S0506BC-1767-00
CU4S0506BC-1842-00
CU4S0506BC-1862-00
CU4S0506BC-1880-00
CU4S0506BC-1882-00
CU4S0506BC-1900-00
CU4S0506BC-1950-00
CU4S0506BC-1960-00
CU4S0506BC-1962-00
CU4S0506BC-2017-00
CU4S0506BC-2140-00
CU4S0506BC-2310-00
CU4S0506BC-2350-00
CU4S0506BC-2355-00
CU4S0506BC-2535-00
CU4S0506BC-2593-00
CU4S0506BC-2595-00
CU4S0506BC-2655-00
Characteristic Impedance (:) : 50(Nominal)
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20151001 / rf_circulator_cu4s0506_en.fm
RF Components
CU4S0506 Series
PACKAGING STYLE
REEL DIMENSIONS
330
Dimensions in mm
TAPE DIMENSIONS
Reel side
Pulling side
P2
P0
K0
P1
T
A0
50Ω Load
GND
I/O
A0
5.6±0.1
GND
GND
I/O
B0
5.6±0.1
D0
1.5+0.1/–0
B0
W
F
E
D0
Dimensions in mm
E
1.75±0.1
F
7.5±0.1
P0
4.0±0.1
P1
12.0±0.1
P2
2.0±0.1
W
16.0+0.3/–0.1
K0
2.6±0.1
T
0.3±0.05
PACKAGE QUANTITY
Standard package quantity
(pieces/reel)
1000
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20151001 / rf_circulator_cu4s0506_en.fm
RF Components
CU4S0506 Series
RECOMMENDED REFLOW PROFILE
Soaking
Working
Soldering
Peak
T: Temperature
T4
T5
T3
T2
T4
T3
t3
T1
t1
t2
t: Time
Soaking
Temp.
T1
150°C
T2
180°C
Time
t1
60 to 120s
Working
Temp.
T3
230°C
Time
t2
30 to 60s
Soldering Peak
Temp.
Time
T4
t3
250°C
within 10s
Temp.
T5
260°C max.
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20151001 / rf_circulator_cu4s0506_en.fm
RF Components
REMINDERS FOR USING THESE PRODUCTS
Before using these products, be sure to request the delivery specifications.
SAFETY REMINDERS
Please pay sufficient attention to the warnings for safe designing when using these products.
REMINDERS
Please do not bring the magnet close to the product (Recommending is separating to 50cm or more). An electric
characteristic might be deteriorated.
The magnetic field of 5mT or more must not go into the product when you make the magnet approach.
Moreover, please do not touch a soft magnetic material such as iron (Recommending is separating to 10mm or
more). An electric characteristic might be deteriorated. An electric characteristic changes when bringing it close
within 10mm(reversible change).
There is a leakage of some magnetism (0.3T or less) from the product.
The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment,
home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment,
industrial robots) under a normal operation and use condition.
The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality
require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person
or property.
Please understand that we are not responsible for any damage or liability caused by use of the products in any of the applications below
or for any other use exceeding the range or conditions set forth in this catalog.
(1) Aerospace/Aviation equipment
(2) Transportation equipment (cars, electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose
applications
When using this product in general-purpose applications, you are kindly requested to take into consideration securing protection circuit/
equipment or providing backup circuits, etc., to ensure higher safety.
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20151001 / rf_circulator_cu4s0506_en.fm
Similar pages