2-Line Filters B84114 SIFI-D Series SIFI-D for high insertion loss Rated voltage 250 V~, 50/60 Hz Rated current 1 A to 10 A Construction ■ Two-line filter ■ Metal case ■ Polyurethane potting (UL 94 V-0) Features ■ ■ ■ ■ ■ Compact design Low leakage current All relevant approvals Cost-optimized construction Also for assembly on top-hat rails Applications ■ Switch-mode power supplies in – industrial electronics – telecommunications – data systems – medical engineering Case styles and terminal styles Case style A Tab connectors on face ends, lateral mounting tabs. Particularly suitable for mounting on a shielding wall. Case style B Tab connectors on face ends, mounting tabs on face ends. Case style K IEC connector as per IEC 60320 C 14 on line side, tab connectors on load side, mounting holes with metric thread. Case style L Litz wires on face ends Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code 160 03/01 2-Line Filters B84114 SIFI-D Series Circuit diagram LINE LOAD N N’ L L’ SSB0238-A Technical data Rated voltage V R 250 V~, 50/60 Hz Rated current IR Referred to 40 °C ambient temperature Test voltage V P 1414 V–, 2 s (line/line) 2700 V–, 2 s (lines/case) Leakage current lleak < 0,5 mA at 230 V~, 50 Hz Discharge resistors The discharge resistors are rated such that one second after having disconnected the device from the power line, the voltage at the line connector should have dropped to 34 V. Climatic category In accordance with EN 60068-1 25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test) Approvals EN 133221 161 03/01 2-Line Filters B84114 SIFI-D Series Characteristics and ordering codes IR CR LR Case style A Appr. Ordering code weight g Mounting plate for top-hat rail (ordering code) 1 2 × 0,47 µF (X2) 2 × 5,6 mH A + B 2 × 4700 pF (Y2) K L 150 150 210 150 B84114-D-A10 B84114-D-B10 B84114-D-K10 B84114-D-L10 — C62122-A132-B92 — — 2 2 × 0,47 µF (X2) 2 × 5,6 mH A + B 2 × 4700 pF (Y2) L 150 150 150 B84114-D-A20 B84114-D-B20 B84114-D-L20 — C62122-A132-B92 — 3 2 × 0,47 µF (X2) 2 × 5,6 mH A + B 2 × 4700 pF (Y2) K L 150 150 210 150 B84114-D-A30 B84114-D-B30 B84114-D-K30 B84114-D-L30 — C62122-A132-B92 — — 6 2 × 0,47 µF (X2) 2 × 4,7 mH A + B 2 × 4700 pF (Y2) K L 230 230 290 230 B84114-D-A60 B84114-D-B60 B84114-D-K60 B84114-D-L60 — C62122-A132-B93 — — 10 2 × 0,68 µF (X2) 2 × 4,7 mH A + B 2 × 4700 pF (Y2) L 420 420 420 B84114-D-A110 B84114-D-B110 B84114-D-L110 — C62122-A132-B94 — 162 03/01 2-Line Filters B84114 SIFI-D Series Case styles and dimensions Case style Ordering code B84114- Dimensions in mm b2 b3 b4 b1 l1 l2 l3 l4 h1 h2 Litz mm2 Style 1015 A B K L -D-A10 -D-B10 -D-K10 -D-L10 50,8 50,8 50,8 50,8 63,5 63,5 79,5 63,5 — 74,7 — 74,7 — 84,5 — 84,5 89,5 89,5 — — 28,6 28,6 32 28,6 20 20 — — — — — 0,82 — — — AWG18 A B L -D-A20 -D-B20 -D-L20 50,8 31,5 60,4 70 — 50,8 31,5 — — — 50,8 — 89,5 28,6 20 — 63,5 — 63,5 74,7 84,5 89,5 28,6 20 28,6 — 63,5 74,7 84,5 — — — 0,82 — — AWG18 A B K L -D-A30 -D-B30 -D-K30 -D-L30 50,8 50,8 50,8 50,8 31,5 31,5 — — 60,4 — — — 70 — — — 63,5 63,5 79,5 63,5 — 74,7 — 74,7 — 84,5 — 84,5 89,5 89,5 — — 28,6 28,6 32 28,6 20 20 — — — — — 0,82 — — — AWG18 A B K L -D-A60 -D-B60 -D-K60 -D-L60 50,8 50,8 50,8 50,8 31,5 31,5 — — 60,4 — — — 70 — — — 75,5 75,5 92,5 75,5 — 87,1 — 87,1 — 97 — 97 101,5 101,5 — — 31,8 31,8 32 31,8 20 20 — — — — — 0,82 — — — AWG18 A B L -D-A110 -D-B110 -D-L110 — see dimensional drawing see dimensional drawing 92 103,1 113 — 44,5 — 1,35 AWG16 31,5 31,5 — — 50,8 — 60,4 — — — — 70 — — — 163 03/01 2-Line Filters B84114 SIFI-D Series Case style A Case style B B84114-D-A10 … B84114-D-A60 B84114-D-B10 … B84114-D-B60 Tab connector B84114-D-A110 Tab connector Tab connector B84114-D-B110 Tab connector 164 03/01 2-Line Filters B84114 SIFI-D Series Case style K Case style L Tab connector BN BU Mounting detail BN GN/YE 165 03/01 BU 2-Line Filters B84114 SIFI-D Series Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84114-D-*10 ... B84114-D-*30 B84114-D-*60 SSB0265-7 100 αe dB αe dB 80 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f SSB0266-F 100 0 10 4 B84114-D-*110 SSB0267-N 100 αe dB 80 60 40 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 166 03/01 10 5 10 6 10 7 Hz 10 8 f Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1