SICK M40E-082223RB0 Multiple light beam safety device Datasheet

Online data sheet
M40S-082203AA0, M40E-082223RB0
M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
Ordering information
System part
Type
Part no.
Sender
M40S-082203AA0
1200077
M40E-082223RB0
1206683
Receiver
Other models and accessories
www.sick.com/M4000_Advanced
Detailed technical data
Features
H
I
J
K
L
M
N
O
P
Q
R
S
T
Scanning range
0.5 m ... 70 m, configurable
Low scanning range
0.5 m ... 20 m
Great scanning range
9 m ... 70 m
Number of beams
8
Beam separation
220 mm
Response time
11 ms
Synchronization
Optical synchronisation
End cap with integrated LED
✔
Safety-related parameters
Type
Type 4 (IEC 61496)
Safety integrity level
SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category
Category 4 (EN ISO 13849)
Performance level
PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)
6.6 x 10-9 (EN ISO 13849)
TM (mission time)
20 years (EN ISO 13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
Functions
Functions
Delivery status
Restart interlock
✔
Internal
External device monitoring (EDM)
✔
Activated
Beam coding
✔
Uncoded
Sender test
✔
Deactivated
Configurable scanning range
✔
0.5 m ... 20 m
Configurable application diagnostic output
✔
Contamination (OWS)
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-24 18:11:25
Subject to change without notice
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
Functions
Safe SICK device communication via EFI
✔
Muting
✔
Delivery status
Interfaces
System connection
Connection type Hirschmann male connector M26, 12-pin
Permitted cable length ≤ 50 m 1)
Permitted cross-section ≥ 0.75 mm²
Extension connection
Connection type Male connector M12, 5-pin
Configuration method
PC with CDS (Configuration and Diagnostic Software)
Configuration connection
Connection type Female connector M8, 4-pin
Display elements
LEDs
7-segment display
Fieldbus, industrial network
Integration via EFI gateways CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 2)
Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 3)
1)
2)
3)
Depending on load, power supply and wire cross-section. The technical specifications must be observed.
For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class
III (EN 50178)
Supply voltage VS
24 V DC (19.2 V DC ... 28.8 V DC) 1)
Residual ripple
≤ 10 % 2)
Power consumption
≤ 0.2 A: ≤ 0.6 A (depending on type)
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3)
Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)
Switching voltage LOW ≤ 2 V DC
Switching current ≤ 500 mA
Diagnostic outputs
Type of output PNP semiconductor, short-circuit protected
Switching voltage HIGH 24 V DC (VS – 4.2 V DC ... VS)
Switching voltage LOW High resistance
Switching current ≤ 100 mA
1)
The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as
accessories from SICK.
2)
3)
Within the limits of VS.
Applies to the voltage range between –30 V and +30 V.
Mechanical data
Housing cross-section
2017-08-24 18:11:25 | Online data sheet

Subject
to change without notice
52 mm x 55.5 mm
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
Housing material
Aluminum alloy ALMGSI 0.5
Surface treatment
Powder coated
Front screen material
Polycarbonate, scratch-resistant coating
Ambient data
Enclosure rating
IP65 (EN 60529)
Ambient operating temperature
–30 °C ... +55 °C
Storage temperature
–30 °C ... +70 °C
Air humidity
15 % ... 95 %, Non-condensing
Vibration resistance
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
Shock resistance
10 g, 16 ms (IEC 60068-2-29)
Other information
Wave length
950 nm
Classifications
H
I
J
K
L
M
N
O
P
Q
R
S
T
ECl@ss 5.0
27272703
ECl@ss 5.1.4
27272703
ECl@ss 6.0
27272703
ECl@ss 6.2
27272703
ECl@ss 7.0
27272703
ECl@ss 8.0
27272703
ECl@ss 8.1
27272703
ECl@ss 9.0
27272703
ETIM 5.0
EC001832
ETIM 6.0
EC001832
UNSPSC 16.0901
46171620
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-24 18:11:25
Subject to change without notice
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
Dimensional drawing (Dimensions in mm (inch))
14
(0.24)
1
2.2
2 Laser warning
label (receiver with
integrated alignment
aid only)
S1
(0.55)
Optional (receiver only)
design with integrated
LED
10.5
(0.09)
1
6
(0.79)
>20
(1.08)
3.5
(2.19)
(0.14)
55.5
27.5
(0.04)
25
52
(2.05)
(0.98)
M4000 Advanced
(0.41)
Sliding nut groove for
side mounting
1 Laser output opening
(receiver with
integrated alignment
aid only)
L2
L1
Mounting ranges
for brackets
47.5
(1.87)
87 (3.43)
Ca. 125 (4.92)
(connector range)
13
M4000 Advanced (receiver) or
M4000 Advanced A/P
(0.51)
>20
(0.79)
25.5
23.5
(0.93)
(1.00)
14.4
(0.57)
71.2 (2.80)
1
99.8 (3.93)
S1
2
Cable socket M26 with crimp
contacts (for DIN 43651, left)
and cable plug M12 with
cable (right, only on receiver)
Number of beams
Beam separation S1
L1
L2
2
500 (19.69)
643 (25.31)
672 (26.46)
600 (23.62)
743 (29.25)
772 (30.39)
220 (8.66)
583 (22.95)
612 (24.09)
400 (15.75)
943 (37.13)
972 (38.27)
450 (17.72)
1,043 (41.06)
1,072 (42.20)
220 (8.66)
803 (31.61)
832 (32.76)
300 (11.81)
1,043 (41.06)
1,072 (42.20)
220 (8.66)
1,023 (40.28)
1,052 (41.42)
6
1,243 (48.94)
1,272 (50.08)
7
1,462 (57.56)
1,491 (58.70)
8
1,682 (66.22)
1,711 (67.36)
3
4
5
2017-08-24 18:11:25 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
Connection diagram
M4000 Advanced with UE403 switching amplifier connected to UE10-3OS safety relay
+24 V
A1
A2
5
6
7
8
9
10
11
2
FE
H
I
J
K
L
M
N
O
P
Q
R
S
T
RES
n.c.
EFia
n.c.
EFib
n.c.
OSSD1
n.c.
OSSD2
EFIa
BS/C1
EFIb
ADO
n.c.
RR
FE
M4000S
Advanced
COM
S1
+
- Q
H3
+
- Q
6
9
10
1 2 3 4 5
1 2 3 4 5
+
+
RR -
IN
IN
-
T
RES/OVR
3
IN
1 2 3 4 5
+
T
A1
-
IN
A2
5
4
COM
UE403
11
B2
7
L
8
GND
FE
S2
5
EDM
n.c.
GND
1
-
+
1 2 3 4 5
T
-
B1
IN
+
1 2 3 4 5
T
-
IN
1 2 3 4 5
2
H1
FE
5
M4000R
Advanced
B2
B1 B3
Y1 13 23 33 41
1)
+
4
+24V
Test
-
3
+24V
Q
B1
+
1
-
A
B
C
D
E
F
Q
UE10-3OS
B2 B4
Y2 14 24 34 42
0V
2) PELV
E119906/00/2014-07-29
Task
Connection of an M4000 Advanced multiple light beam safety device with UE403 switching amplifier to a UE10-3OS safety relay.
Muting with 4 photoelectric reflex switches (dark-switching, PNP).
Operating mode: with restart interlock and external device monitoring.
Operating characteristics
When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3
lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and
releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of
the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs.
Muting and override
When the light path is clear and the muting input conditions are valid, muting starts. The H1 muting lamp illuminates. Different
time and monitoring functions can be configured.
When the light path is interrupted and muting sensors are active, e.g., because of muting errors or a new power on, override is enabled by pressing and releasing the S2 button.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the
UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does
not enable the output current circuits.
The failure of one muting sensor will be detected by the muting sequence and prohibit a new muting cycle. On manipulation (e.g.,
jamming) of the S2 button, the system does not enable override. A permanent use of the override function will be inhibited through
the device.
Comments
1)
Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2)
PELV in accordance with the requirements in
EN 60204-1 / 6.4
Take note of the operating instructions of the integrated devices. This applies particularly to the use of configurable functions.
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-24 18:11:25
Subject to change without notice
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
Recommended accessories
Other models and accessories
www.sick.com/M4000_Advanced
Brief description
Type
Part no.
BEF-3WNGBAST4
7021352
4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast
BEF-1SHABAZN4
2019506
4 pieces, Omega bracket, rotatable, fixable with only one screw, for mounting on the
swivel mount, including spacer discs
BEF-2SMGEAAL4
2044846
4 pieces, Mounting kit 12, rotatable, swivel mount
BEF-2SMGEAKU4
2030510
UE403-A0930
1026287
Head A: female connector, M26, 12-pin, straight
Head B: cable
Cable: PVC, unshielded, 5 m
DOL-0612G05M075KM0
2022545
Head A: female connector, M26, 12-pin, straight
Head B: cable
Cable: PVC, unshielded, 10 m
DOL-0612G10M075KM0
2022547
Head A: female connector, M26, 12-pin, straight
Head B: cable
Cable: PVC, unshielded, 20 m
DOL-0612G20M075KM0
2022549
Head A: female connector, M12, 5-pin, straight, A-coding
Head B: male connector, M12, 5-pin, straight, A-coding
Cable: digital I/Os, drag chain use, PUR, halogen-free, unshielded, 2 m
DSL-1205-G02MC
6025931
Head A: female connector, M12, 5-pin, straight
Head B: male connector, M12, 5-pin, straight
Cable: drag chain use, PUR, halogen-free, unshielded, 0.6 m
DSL-1205-G0M6C
6025930
Head A: male connector, M8, 4-pin, straight
Head B: male connector, USB-A, straight
Cable: PVC, unshielded, 2 m
DSL-8U04G02M025KM1
6034574
Head A: male connector, M8, 4-pin, straight
Head B: male connector, USB-A, straight
Cable: PVC, unshielded, 10 m
DSL-8U04G10M025KM1
6034575
Head A: female connector, M26, 12-pin, straight
Head B: Cable: unshielded
DOS-0612G000GA3KM0
6020757
Head A: female connector, M26, 12-pin, angled
Head B: Cable: unshielded
DOS-0612W000GA3KM0
6020758
Mounting brackets and plates
4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws
and washers
Terminal and alignment brackets
Switching amplifiers
UE403 muting switching amplifier
Plug connectors and cables
2017-08-24 18:11:25 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
7
M40S-082203AA0, M40E-082223RB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Brief description
Type
Part no.
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into
the beam!
AR60
1015741
AR60 adapter, M4000
4040006
Parallel muting (2 sensors), muting sensor brackets for mounting on M4000 housing
profile or device columns with external mounting grooves
Muting arm kit M4000,
2 sensors, parallel muting
2060157
Parallel muting (2 sensors), muting sensor brackets for mounting on M4000 housing
profile or device column with external mounting grooves
Muting arm kit M4000,
2 sensors, parallel muting
2060156
Alignment aids
Adapter AR60 for M4000 and M4000 Curtain
Muting accessories
8
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-24 18:11:25
Subject to change without notice
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages