Lineage Power EBVW020A0B41PHZ 36-75vdc input; 12.0vdc, 20.0a, 240w output Datasheet

GE
Data Sheet
EBVW020A0B Barracuda* Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Features
 Compliant to RoHS EU Directive 2011/65/EC (-Z versions)
 Compliant to REACH Directive (EC) No 1907/2006
 Compatible with reflow pin/paste soldering process
Applications

Distributed power architectures

Intermediate bus voltage applications

Servers and storage applications

Networking equipment including Power over Ethernet
(PoE)

Fan assemblies other systems requiring a tightly
regulated output voltage
Options

Negative Remote On/Off logic (1=option code, factory
preferred)

Auto-restart after fault shutdown (4=option code,
factory preferred)


Remote Sense and Output Voltage Trim (9=option code)
Base plate option (-H=option code)

Passive Droop Load Sharing (-P=option code)
 High and flat efficiency profile – 95.4% at 12Vdc, 55% load to
90% output
 Wide Input voltage range: 36-75Vdc
 Delivers up to 20Adc output current
 Output Voltage adjust: 6.0Vdc to 13.2Vdc
 Tightly regulated output voltage
 Low output ripple and noise
 No reverse current during prebias start-up or shut-down
 Industry standard, DOSA compliant, Eight brick:
 58.4 mm x 22.8 mm x 11.3 mm
 (2.30 in x 0.90 in x 0.44 in)
 Constant switching frequency
 Positive Remote On/Off logic
 Output over current/voltage protection
 Over temperature protection
 Wide operating temperature range (-40°C to 85°C)
 CAN/CSA† C22.2 No. 60950-1-07, 2nd Edition + A1:2011 (MOD),
ANSI/UL#60950-1-2011, IEC 60950-1 (2nd edition); am1, and
VDE‡ (EN60950-1, 2nd Ed.) Licensed
 CE mark 2006/96/EC directives§
 Meets the voltage and current requirements for ETSI 300-1322 and complies with and licensed for Basic insulation rating
per EN60950-1
 2250 Vdc Isolation tested in compliance with IEEE 802.3¤ PoE
standards
 ISO** 9001 and ISO14001 certified manufacturing facilities
Description
The EBVW020A0B series of dc-dc converters are a new generation of DC/DC power modules designed to support 9.6 -12Vdc
intermediate bus applications where multiple low voltages are subsequently generated using point of load (POL) converters, as
well as other application requiring a tightly regulated output voltage. The EBVW020A0B series operate from an input voltage
range of 36 to 75Vdc, and provide up to 20A output current at output voltages from 6.0Vdc to 12.0Vdc, and 240W output power
from output voltages of 12.1Vdc to 13.2Vdc in a DOSA standard eighth brick. The converter incorporates digital control,
synchronous rectification technology, and innovative packaging techniques to achieve efficiency reaching 95.4% peak at 12Vdc
output. This leads to lower power dissipations such that for many applications a heat sink is not required. Standard features
include on/off control, output overcurrent and over voltage protection, over temperature protection, input under and over
voltage lockout. Optional features include output voltage remote sense and trim from 6.0Vdc to 13.2Vdc, passive droop paralleling,
and base plate for heat sink or cold wall applications.
The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. Built-in filtering
for both input and output minimizes the need for external filtering.
* Trademark of General Electric Company
# UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
** ISO is a registered trademark of the International Organization of Standards.
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 1
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Device
Symbol
Min
VIN
-0.3
Max
Unit
Input Voltage*
Continuous
Operating transient ≤ 100mS
Operating Input transient slew rate, 50VIN to 75VIN
(Output may exceed regulation limits, no protective
shutdowns shall activate, CO=220μF to CO, max)
Non- operating continuous
Operating Ambient Temperature
-
75
Vdc
100
Vdc
-
10
V/µs
VIN
80
100
Vdc
All
TA
-40
85
°C
All
Tstg
-55
(See Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage (100% factory Hi-Pot tested)
All


* Input over voltage protection will shutdown the output voltage, when the input voltage exceeds threshold level.
125
°C
2250
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Operating Input Voltage
Maximum Input Current
(VIN=0V to 75V, IO=IO, max)
Input No Load Current
(VIN = VIN, nom, IO = 0, module enabled)
Input Stand-by Current
(VIN = VIN, nom, module disabled)
Symbol
Min
Typ
Max
Unit
VIN
36
48
75
Vdc
IIN,max
-
-
7
Adc
All
IIN,No load
All
IIN,stand-by
External Input Capacitance
All
Inrush Transient
All
50
mA
25
mA
100
-
-
μF
-
-
1
A2s
All
-
900
-
mArms
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN= 48V, IO= IOmax ; see
Figure 12)
All
-
24
-
mAp-p
Input Ripple Rejection (120Hz)
All
-
50
-
dB
I2t
Input Terminal Ripple Current
(Measured at module input pin with maximum specified input
capacitance and ൏ 500uH inductance between voltage source
and input capacitance CIN=220uF, 5Hz to 20MHz, VIN= 48V, IO=
IOmax)
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part
of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating
of 15 A (see Safety Considerations section). Based on the information provided in this Data Sheet on inrush energy and maximum
dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s Data Sheet for further
information.
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
(VIN=VIN,nom, IO=10A, TA =25°C)
Output Voltage
(Over all operating input voltage(40V to 75V), resistive load, and
temperature conditions until end of life)
Output Voltage (VIN=36V, TA = 25ºC)
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
11.97
12.00
12.03
Vdc
All w/o -P
VO
11.76

12.24
Vdc
-P Option
VO
11.63

12.37
Vdc
All
VO
10.8


Vdc
Output Regulation (VIN, min=40V)
Line (VIN=VIN, min to VIN, max)
All w/o -P

0.2

% VO, set
Load (IO=IO, min to IO, max)
All w/o -P

0.2

Line (VIN=VIN, min to VIN, max)
-P Option

0.5

% VO, set
% VO, set
Load (IO=IO, min to IO, max), Intentional Droop
-P Option

% VO, set
0.50
Vdc
All

RMS (5Hz to 20MHz bandwidth)
All

70

mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All

200

mVpk-pk
220

Temperature (TA = -40ºC to +85ºC)
2
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max, tested with a 1.0 μF ceramic,
10 μF aluminum and 220μF polymer capacitor across the
load.)
External Output Capacitance
All
CO
Output Current
All
Io
0
Output Current Limit Inception
All
IO, lim

IO= 100% IO, max
All
η
95.2
%
IO= 55% - 90% IO, max
All
η
95.4
%
fsw
150
kHz
23
10,000
μF
20
Adc

Adc
Efficiency (VIN=VIN, nom, VO= VO,set, TA=25°C)
Switching Frequency (primary MOSFETs)
(Output Ripple 2X switching frequency)
Dynamic Load Response
(dIo/dt=1A/10s; Vin=Vin,nom; TA=25°C; tested with a 10 μF
ceramic and 1x 470μF polymer capacitor across the load.)
Load Change from Io= 50% to 75% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
All
Load Change from Io= 75% to 50% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
Vpk
ts

__
750
800
Vpk
ts
__
__
750
800

__

__
mVpk
s
mVpk
s
Isolation Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
Ciso

1000

pF
Isolation Resistance
Riso
10


MΩ
General Specifications
Parameter
Device
Symbol
Typ
All
MTBF
4,169,213
Hours
239.9
109/Hour
s
Weight – Open Frame
29.5 (1.04)
g (oz.)
Weight – with Baseplate option
39.0 (1.38)
g (oz.)
Calculated Reliability Based upon Telcordia SR-332 Issue 2:
Method I, Case 1, (IO=80%IO, max, TA=40°C, Airflow = 200 lfm), 90%
confidence
July 22, 2013
All
FIT
©2012 General Electric Company. All rights reserved.
Unit
Page 3
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max , Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low Specification
On/Off Thresholds:
Remote On/Off Current – Logic Low
All
Ion/off
280

310
μA
Logic Low Voltage
All
Von/off
-0.3

0.8
Vdc
Logic High Voltage – (Typ = Open Collector)
All
Von/off
2.0

14.5
Vdc
Logic High maximum allowable leakage current
(Von/off = 2.0V)
All
Ion/off


10
μA
Maximum voltage allowed on On/Off pin
All
Von/off


14.5
Vdc
Tdelay, Enable with


160
ms


40
ms


180*
ms


40*
ms
Turn-on Delay and Rise Time (IO=IO, max)
All w/o -P
Tdelay=Time until VO = 10% of VO,set from either application of Vin
with Remote On/Off set to On (Enable with Vin); or operation of
Remote On/Off from Off to On with Vin already applied for at
least 150 milli-seconds (Enable with on/off).
* Increased Tdelay due to startup for parallel modules.
Trise=Time for VO to rise from 10% to 90% of VO,set, For CO
>5000uF, IO must be < 50% IO, max during Trise.
* Increased Trise when Vo exists at startup for parallel
modules.
Load Sharing Current Balance
(difference in output current across all modules with outputs in
parallel, no load to full load)
Prebias Output Load Performance:
Back Bias current sunk by output during start-up
Back Bias current sunk by output during shut-down
All w/o-P
w/ -P
w/ -P
Vin
Tdelay, Enable with
on/off
Tdelay, Enable with
Vin
Tdelay, Enable with
on/off
All w/o -P
Trise


40
ms
w/ -P
Trise


300*
ms
-P Option
Idiff
3
A
All




50
50
mA
mA

0.5
Vdc
Remote Sense Range
All w/ ”9”
option
VSense

Output Voltage Adjustment range
All w/ ”9”
option
VO, set
6.0
13.2
Vdc
All
VO,limit
14.5
17.0
Vdc
All
Tref

140

°C
Output Overvoltage Protection
Overtemperature Protection
(See Feature Descriptions)
Input Undervoltage Lockout
Turn-on Threshold

35
36
Vdc
Turn-off Threshold
32
33.5

Vdc
Turn-off Threshold

85
86
Vdc
Turn-on Threshold
76
79

Vdc
Input Overvoltage Lockout
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 4
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Characteristic Curves
INPUT CURRENT, Ii (A)
OUTPUT VOLTAGE On/Off VOLTAGE
VO (V) (5V/div)
VON/OFF (V) (2V/div)
The following figures provide typical characteristics for the EBVW020A0B (12V, 20A) at 25ºC. The figures are identical for either
positive or negative Remote On/Off logic.
INPUT VOLTAGE, VO (V)
EFFCIENCY, η (%)
OUTPUT CURRENT, IO (A)
TIME, t (1 ms/div)
Figure 5. Typical Transient Response to Step change in Load
from 25% to 50% to 25% of Full Load at 48 Vdc Input and
470uF Polymer.
TIME, t (40 ms/div)
Figure 3. Typical Start-Up Using Vin with Remote On/Off
enabled, negative logic version shown.
OUTPUT CURRENT
IO (A) (5A/div)
OUTPUT VOLTAGE
VO (V) (500mV/div)
OUTPUT VOLTAGE INPUT VOLTAGE
VO (V) (5V/div)
VIN(V) (20V/div)
Figure 2. Typical Converter Efficiency Vs. Output current at
Room Temperature.
July 22, 2013
TIME, t (20 ms/div)
Figure 4. Typical Start-Up Using Remote On/Off with Vin
applied, negative logic version shown.
OUTPUT CURRENT OUTPUT VOLTAGE
IO (A) (5A/div)
VO (V) (500mV/div)
Figure 1. Typical Input Characteristic at Room
Temperature.
TIME, t (1 ms/div)
Figure 6. Typical Transient Response to Step Change in Load
from 50% to 75% to 50% of Full Load at 48 Vdc Input and
470uF Polymer.
©2012 General Electric Company. All rights reserved.
Page 5
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
OUTPUT VOLTAGE, VO (V)
OUTPUT VOLTAGE, VO (V)
Characteristic Curves (continued)
INPUT VOLTAGE, Vin (V)
INPUT VOLTAGE, Vin (V)
Figure 10. Typical Output Voltage Regulation vs. Input
Voltage for the –P Version at Room Temperature.
OUTPUT VOLTAGE, VO (V)
OUTPUT VOLTAGE, VO (V)
Figure 7. Typical Output Voltage Regulation vs. Input Voltage
at Room Temperature.
OUTPUT CURRENT, IO (A)
OUTPUT CURRENT, IO (A)
Figure 8. Typical Output Voltage Regulation vs. Output
Current at Room Temperature.
Figure 11. Typical Output Voltage Regulation vs. Output
Current for the –P Version at Room Temperature.
OUTPUT VOLTAGE,
VO (V) (50mV/div)
36 Vin
48 Vin
75 Vin
TIME, t (2s/div)
Figure 9. Typical Output Ripple and Noise at Room
Temperature Io = Io,max and and COMin.
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 6
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Test Configurations
Design Considerations
Input Source Impedance
The power module should be connected to a low ac-impedance
source. A highly inductive source impedance can affect the
stability of the power module. For the test configuration in
Figure 12, a 220μF electrolytic capacitor, Cin, (ESR<0.7 at
100kHz), mounted close to the power module helps ensure the
stability of the unit. If the module is subjected to rapid on/off
cycles, a 330μF input capacitor is required. Consult the factory
for further application guidelines.
Safety Considerations
Note: Measure input reflected-ripple current with a simulated
source inductance (LTEST) of 12 µH. Capacitor CS offsets
possible battery impedance. Measure current as shown above.
Figure 12. Input Reflected Ripple Current Test Setup.
For safety-agency approval of the system in which the power
module is used, the power module must be installed in
compliance with the spacing and separation requirements of
the end-use safety agency standard, i.e., UL60950-1 2nd Ed.,
CSA C22.2 No. 60950-1 2nd Ed., and VDE0805-1 EN60950-1 2nd
Ed.
If the input source is non-SELV (ELV or a hazardous voltage
greater than 60 Vdc and less than or equal to 75Vdc), for the
module’s output to be considered as meeting the requirements
for safety extra-low voltage (SELV), all of the following must be
true:
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or
tantalum capacitor. Scope measurement should be made
using a BNC socket. Position the load between
51 mm and 76 mm (2 in. and 3 in.) from the module.
Figure 13. Output Ripple and Noise Test Setup.
CONTACT AND
DISTRIBUTION LOSSES
VI(+)
VO1
IO
II
LOAD
SUPPLY
VI(–)
VO2
CONTACT
RESISTANCE
Note: All measurements are taken at the module terminals. When
socketing, place Kelvin connections at module terminals to avoid
measurement errors due to socket contact resistance.

The input source is to be provided with reinforced
insulation from any other hazardous voltages, including
the ac mains.

One VIN pin and one VOUT pin are to be grounded, or both
the input and output pins are to be kept floating.

The input pins of the module are not operator accessible.

Another SELV reliability test is conducted on the whole
system (combination of supply source and subject
module), as required by the safety agencies, to verify that
under a single fault, hazardous voltages do not appear at
the module’s output.
Note: Do not ground either of the input pins of the module
without grounding one of the output pins. This may
allow a non-SELV voltage to appear between the output
pins and ground.
The power module has safety extra-low voltage (SELV) outputs
when all inputs are SELV.
The input to these units is to be provided with a maximum 15 A
fast-acting (or time-delay) fuse in the unearthed lead.
The power module has internally generated voltages exceeding
safety extra-low voltage. Consideration should be taken to
restrict operator accessibility.
Figure 14. Output Voltage and Efficiency Test Setup.
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 7
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Feature Descriptions
Overcurrent Protection
To provide protection in a fault output overload condition, the
module is equipped with internal current-limiting circuitry and
can endure current limiting continuously. If the overcurrent
condition causes the output voltage to fall greater than 4.0V
from Vo,set, the module will shut down and remain latched off.
The overcurrent latch is reset by either cycling the input power
or by toggling the on/off pin for one second. If the output
overload condition still exists when the module restarts, it will
shut down again. This operation will continue indefinitely until
the overcurrent condition is corrected.
A factory configured auto-restart option (with overcurrent and
overvoltage auto-restart managed as a group) is also available.
An auto-restart feature continually attempts to restore the
operation until fault condition is cleared.
overvoltage latch is reset by either cycling the input power, or
by toggling the on/off pin for one second. If the output
overvoltage condition still exists when the module restarts, it
will shut down again. This operation will continue indefinitely
until the overvoltage condition is corrected.
A factory configured auto-restart option (with overcurrent and
overvoltage auto-restart managed as a group) is also available.
An auto-restart feature continually attempts to restore the
operation until fault condition is cleared.
Overtemperature Protection
These modules feature an overtemperature protection circuit to
safeguard against thermal damage. The circuit shuts down the
module when the maximum device reference temperature is
exceeded. The module will automatically restart once the
reference temperature cools by ~25°C.
Input Under/Over voltage Lockout
At input voltages above or below the input under/over voltage
lockout limits, module operation is disabled. The module will
begin to operate when the input voltage level changes to within
the under and overvoltage lockout limits.
Remote On/Off
The module contains a standard on/off control circuit reference
to the VIN(-) terminal. Two factory configured remote on/off logic
options are available. Positive logic remote on/off turns the
Load Sharing
module on during a logic-high voltage on the ON/OFF pin, and
off during a logic low. Negative logic remote on/off turns the
For higher power requirements, the EBVW020A0 power module
module off during a logic high, and on during a logic low.
offers an optional feature for parallel operation (-P Option code).
Negative logic, device code suffix "1," is the factory-preferred
This feature provides a precise forced output voltage load
configuration. The On/Off circuit is powered from an internal
regulation droop characteristic. The output set point and droop
bias supply, derived from the input voltage terminals. To turn
slope are factory calibrated to insure optimum matching of
the power module on and off, the user must supply a switch to
multiple modules’ load regulation characteristics. To implement
control the voltage between the On/Off terminal and the VIN(-)
load sharing, the following requirements should be followed:
terminal (Von/off). The switch can be an open collector or
 The VOUT(+) and VOUT(-) pins of all parallel modules must be
equivalent (see Figure 15). A logic low is Von/off = -0.3V to 0.8V.
connected together. Balance the trace resistance for each
The typical Ion/off during a logic low (Vin=48V, On/Off
module’s path to the output power planes, to insure best load
Terminal=0.3V) is 147µA. The switch should maintain a logic-low
sharing and operating temperature balance.
voltage while sinking 310µA. During a logic high, the maximum  VIN must remain between 40Vdc and 75Vdc for droop sharing
Von/off generated by the power module is 8.2V. The maximum
to be functional.
allowable leakage current of the switch at Von/off = 2.0V is 10µA.  It is permissible to use a common Remote On/Off signal to
If using an external voltage source, the maximum voltage Von/off
start all modules in parallel.
on the pin is 14.5V with respect to the VIN(-) terminal.
 These modules contain means to block reverse current flow
If not using the remote on/off feature, perform one of the
upon start-up, when output voltage is present from other
following to turn the unit on:
parallel modules, thus eliminating the requirement for
external output ORing devices. Modules with the –P option
For negative logic, short ON/OFF pin to VIN(-).
will self determine the presence of voltage on the output
For positive logic: leave ON/OFF pin open.
from other operating modules, and automatically increase its
Turn On delay, Tdelay, as specified in the Feature Specifications
Table.
 When parallel modules startup into a pre-biased output, e.g.
partially discharged output capacitance, the Trise is
automatically increased, as specified in the Feature
Specifications Table, to insure graceful startup.
 Insure that the load is <50% IO,MAX (for a single module) until
all parallel modules have started (load full start > module
Tdelay time max + Trise time).
 If fault tolerance is desired in parallel applications, output
Figure 15. Remote On/Off Implementation.
ORing devices should be used to prevent a single module
Output Overvoltage Protection
failure from collapsing the load bus.
The module contains circuitry to detect and respond to output
overvoltage conditions. If the overvoltage condition causes the
output voltage to rise above the limit in the Specifications Table,
the module will shut down and remain latched off. The
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 8
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Feature Descriptions (continued)
R trim
Remote Sense (“9” Option Code)
Remote sense minimizes the effects of distribution losses by
regulating the voltage at the remote-sense connections (See
Figure 16). The voltage between the remote-sense pins and the
output terminals must not exceed the output voltage sense
range given in the Feature Specifications table:
 down
Where  %   Vo , set  V desired

Vo , set

The amount of power delivered by the module is defined as the
voltage at the output terminals multiplied by the output current.
When using remote sense and trim, the output voltage of the
module can be increased, which at the same output current
would increase the power output of the module. Care should be
taken to ensure that the maximum output power of the module
remains at or below the maximum rated power (Maximum
rated power = Vo,set x Io,max).
 %  20
Rtrim  down

 511

 10.22 k  15.3k

 20
Connecting an external resistor (Rtrim-up) between the T/C1 pin
and the VO(+) (or Sense (+)) pin increases the output voltage set
point. The following equations determine the required external
resistor value to obtain a percentage output voltage change of
∆%:
 5 . 11  V o , set  (100   %) 511


 10 .22  
R trim  up  
1 . 225   %
%


Where
V
 V o , set
 %   desired
V
o , set

SENSE(–)
SUPPLY
VO(+)
VI(-)
VO(–)
 %
IO
II
CONTACT
RESISTANCE
LOAD

5

 5 .11  12 .0  (100  5) 511
R trim  up  

 10 .22  k  938 .8 k
1 .225  5
5


CONTACT AND
DISTRIBUTION LOSSE
Figure 16. Circuit Configuration for remote sense.
Trim, Output Voltage Programming
Trimming allows the output voltage set point to be increased or
decreased; this is accomplished by connecting an external
resistor between the TRIM pin and either the VO(+) pin or the VO() pin.
VO(+)
Rtrim-up
EBVW020A0B

  100


For example, to trim-up the output voltage of the module by 5%
to 12.6V, Rtrim-up is calculated is as follows:
SENSE(+)
VI(+)

  100


For example, to trim-down the output voltage of the module by
20% to 9.6V, Rtrim-down is calculated as follows:
[VO(+) – VO(–)] – [SENSE(+) – SENSE(–)]  0.5 V
Although the output voltage can be increased by both the
remote sense and by the trim, the maximum increase for the
output voltage is not the sum of both. The maximum increase is
the larger of either the remote sense or the trim.
 511

 
 10 . 22  
 %

LOAD
T/C1
Rtrim-down
VO(-)
The voltage between the Vo(+) and Vo(–) terminals must not
exceed the minimum output overvoltage protection value
shown in the Feature Specifications table. This limit includes
any increase in voltage due to remote-sense compensation and
output voltage set-point adjustment trim.
Although the output voltage can be increased by both the
remote sense and by the trim, the maximum increase for the
output voltage is not the sum of both. The maximum increase is
the larger of either the remote sense or the trim. The amount of
power delivered by the module is defined as the voltage at the
output terminals multiplied by the output current. When using
remote sense and trim, the output voltage of the module can be
increased, which at the same output current would increase the
power output of the module. Care should be taken to ensure
that the maximum output power of the module remains at or
below the maximum rated power (Maximum rated power =
VO,set x IO,max).
Thermal Considerations
Figure 17. Circuit Configuration to Trim Output Voltage.
Connecting an external resistor (Rtrim-down) between the T/C1 pin
and the Vo(-) (or Sense(-)) pin decreases the output voltage set
point. To maintain set point accuracy, the trim resistor
tolerance should be ±1.0%.
The following equation determines the required external
resistor value to obtain a percentage output voltage change of
∆%
July 22, 2013
The power modules operate in a variety of thermal
environments and sufficient cooling should be provided to help
ensure reliable operation.
Thermal considerations include ambient temperature, airflow,
module power dissipation, and the need for increased reliability.
A reduction in the operating temperature of the module will
result in an increase in reliability.
©2012 General Electric Company. All rights reserved.
Page 9
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Feature Descriptions (continued)
The thermal data presented here is based on physical
measurements taken in a wind tunnel, using automated
thermo-couple instrumentation to monitor key component
temperatures: FETs, diodes, control ICs, magnetic cores,
ceramic capacitors, opto-isolators, and module pwb
conductors, while controlling the ambient airflow rate and
temperature. For a given airflow and ambient temperature, the
module output power is increased, until one (or more) of the
components reaches its maximum derated operating
temperature, as defined in IPC-9592. This procedure is then
repeated for a different airflow or ambient temperature until a
family of module output derating curves is obtained.
Figure 19. Location of the thermal reference temperature TH2
for Base Plate module. Do not exceed 110 °C.
The output power of the module should not exceed the rated
power for the module as listed in the Ordering Information
table.
Although the maximum temperature of the power modules is
THx, you can limit this temperature to a lower value for
extremely high reliability.
Please refer to the Application Note “Thermal Characterization
Process For Open-Frame Board-Mounted Power Modules” for a
detailed discussion of thermal aspects including maximum
device temperatures.
Heat Transfer via Convection
Increased airflow over the module enhances the heat transfer
via convection. The thermal derating of figures 20 through 22
show the maximum output current that can be delivered by
each module in the indicated orientation without exceeding the
maximum THx temperature versus local ambient temperature
(TA) for air flows of, Natural Convection, 1 m/s (200 ft./min), 2
m/s (400 ft./min).
Heat-dissipating components are mounted on the top side of
the module. Heat is removed by conduction, convection and
radiation to the surrounding environment. Proper cooling can
be verified by measuring the thermal reference temperature
(THx). Peak temperature (THx) occurs at the position indicated in
Figure 18 and 19. For reliable operation this temperature should
not exceed the listed temperature threshold.
The use of Figures 20 is shown in the following example:
Example
What is the minimum airflow necessary for a EBVW020A0B
operating at VI = 48 V, an output current of 14A, and a
maximum ambient temperature of 70 °C in transverse
orientation.
Solution:
Given: Vin= 48V, IO = 14A, TA = 70 °C
Figure 18. Location of the thermal reference temperature
TH1. Do not exceed 113 °C.
OUTPUT CURRENT, IO (A)
Determine required airflow (V) (Use Figure 20):
V = 200LFM or greater.
LOCAL AMBIENT TEMPERATURE, TA (C)
Figure 20. Output Current Derating for the Open Frame
EBVW020A0B in the Transverse Orientation; Airflow
Direction from Vin(-) to Vin(+); Vin = 48V.
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 10
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
OUTPUT CURRENT, IO (A)
suggested. The wave preheat process should be such that the
temperature of the power module board is kept below 210C.
For Pb solder, the recommended pot temperature is 260C,
while the Pb-free solder pot is 270C max. Not all RoHScompliant through-hole products can be processed with pastethrough-hole Pb or Pb-free reflow process. If additional
information is needed, please consult with your GE
representative for more details.
Reflow Lead-Free Soldering Information
The RoHS-compliant through-hole products can be processed
with the following paste-through-hole Pb or Pb-free reflow
process.
OUTPUT CURRENT, IO (A)
LOCAL AMBIENT TEMPERATURE, TA (C)
Figure 21. Output Current Derating for the Base Plate
EBVW020A0Bxx-H in the Transverse Orientation; Airflow
Direction from Vin(-) to Vin(+); Vin = 48V.
Max. sustain temperature :
245C (J-STD-020C Table 4-2: Packaging Thickness>=2.5mm /
Volume > 2000mm3),
Peak temperature over 245C is not suggested due to the
potential reliability risk of components under continuous hightemperature.
Min. sustain duration above 217C : 90 seconds
Min. sustain duration above 180C : 150 seconds
Max. heat up rate: 3C/sec
Max. cool down rate: 4C/sec
In compliance with JEDEC J-STD-020C spec for 2 times reflow
requirement.
Pb-free Reflow Profile
LOCAL AMBIENT TEMPERATURE, TA (C)
Figure 22. Output Current Derating for the Base Plate
EBVW020A0Bxx-H and 0.25” heat sink in the Transverse
Orientation; Airflow Direction from Vin(-) to Vin(+); Vin = 48V.
BMP module will comply with J-STD-020 Rev. C
(Moisture/Reflow Sensitivity Classification for
Nonhermetic Solid State Surface Mount Devices) for both Pbfree solder profiles and MSL classification
procedures. BMP will comply with JEDEC J-STD-020C
specification for 3 times reflow requirement. The suggested Pbfree solder paste is Sn/Ag/Cu (SAC). The recommended linear
reflow profile using Sn/Ag/Cu solder is shown in Figure 23.
Peak Temp. 240 -245°C
The EBVW020 power module series are low profile in order to
be used in fine pitch system card architectures. As such,
component clearance between the bottom of the power
module and the mounting board is limited. Avoid placing
copper areas on the outer layer directly underneath the power
module. Also avoid placing via interconnects underneath the
power module.
For additional layout guide-lines, refer to FLT007A0Z Data
Sheet.
Through-Hole Lead-Free Soldering
Information
The RoHS-compliant, Z version, through-hole products use the
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant
components. The non-Z version products use lead-tin (Pb/Sn)
solder and RoHS-compliant components. Both version modules
are designed to be processed through single or dual wave
soldering machines. The pins have an RoHS-compliant, pure tin
finish that is compatible with both Pb and Pb-free wave
soldering processes. A maximum preheat rate of 3C/s is
July 22, 2013
Temp
Layout Considerations
Ramp down
max. 4°C/Sec
217°C
200°C
Time Limited 90 Sec.
above 217°C
150°C
Preheat time
100-150 Sec.
Ramp up
max. 3°C/Sec
25°C
Time
Figure 23. Recommended linear reflow profile using
Sn/Ag/Cu solder.
MSL Rating
The EBVW020A0BA modules have a MSL rating of 2a.
Storage and Handling
The recommended storage environment and handling
procedures for moisture-sensitive surface mount packages is
©2012 General Electric Company. All rights reserved.
Page 11
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and
Use of Moisture/Reflow Sensitive Surface Mount Devices).
Moisture barrier bags (MBB) with desiccant are required for MSL
ratings of 2 or greater. These sealed packages should not be
broken until time of use. Once the original package is broken,
the floor life of the product at conditions of 30°C and 60%
relative humidity varies according to the MSL rating (see J-STD025A). The shelf life for dry packed SMT packages will be a
minimum of 12 months from the bag seal date, when stored at
the following conditions: < 40° C, < 90% relative humidity.
Post Solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board assembly
process prior to electrical board testing. The result of
inadequate cleaning and drying can affect both the reliability of
a power module and the testability of the finished circuit-board
assembly. For guidance on appropriate soldering, cleaning and
drying procedures, refer to GE Board Mounted Power Modules:
Soldering and Cleaning Application Note (AP01-056EPS).
EMC Considerations
The circuit and plots in Figure 24 shows a suggested
configuration to meet the conducted emission limits of
Level
EN55022 Class B. For further information on designing for EMC
compliance, please refer to the FLT007A0 data sheet.
[dBµV]
80
70
60
+
x
50
+
x
+
x
40
30
x
x
x
20
+
+
+
10
0
150k
x
+
x MES
+ MES
MES
MES
300k
500k
1M
2M
3M 4M 5M
Frequency [Hz]
CE0916111952_fin
CE0916111952_fin
CE0916111952_pre
CE0916111952_pre
7M
10M
30M
QP
AV
PK
AV
Figure 24. EMC Considerations.
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 12
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Packaging Details
All versions of the EBVW020A0B are supplied as standard in
the plastic trays shown in Figure 25. Each tray contains a total
of 18 power modules. The trays are self-stacking and each
shipping box for the EBVW020A0B module contains 2 full trays
plus one empty hold-down tray giving a total number of 36
power modules.
Tray Specification
Material
Max surface resistivity
PET (1mm)
Color
Clear
109 -1011/PET
Capacity
18 power modules
Min order quantity
36 pcs (1 box of 2 full trays
+ 1 empty top tray)
Open Frame Module Tray
Base Plate Module Tray
Figure 25. EBVW020 Packaging Tray
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 13
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Mechanical Outline for EBVW020A0B Through-hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm  0.5 mm [x.xx in.  0.02 in.] (Unless otherwise indicated)
x.xx mm  0.25 mm [x.xxx in  0.010 in.]
Top side label includes GE name, product designation and date code.
Top View*
Side View
*For optional pin lengths, see Table 2, Device Coding Scheme and Options
Bottom View
Pin
1
2
3
4
5†
6†
7†
8
Function
Vi(+)
ON/OFF
Vi(-)
Vo(-)
SENSE(-)
TRIM
SENSE(+)
Vo(+)
† - Optional Pins, when including “9” Option, See Table 2
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 14
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Mechanical Outline for EBVW020A0B–H (Baseplate version) Through-hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm  0.5 mm [x.xx in.  0.02 in.] (Unless otherwise indicated)
x.xx mm  0.25 mm [x.xxx in  0.010 in.]
Top View
Side View
*For optional pin lengths, see Table 2, Device Coding Scheme and Options
* Bottom side label includes GE name, product designation and date
Bottom View*
Pin
1
2
3
4
5†
6†
7†
8
Function
Vi(+)
ON/OFF
Vi(-)
Vo(-)
SENSE(-)
TRIM
SENSE(+)
Vo(+)
† - Optional Pins, when including “9” Option, See Table 2
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 15
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Recommended Pad Layouts
Dimensions are in millimeters and (inches).
Tolerances: x.x mm  0.5 mm ( x.xx in.  0.02 in.) [unless otherwise indicated]
x.xx mm  0.25 mm ( x.xxx in  0.010 in.)
Through-Hole Modules
Pin
Pin
Number Name
1*
VIN(+)
2*
ON/OFF
3*
VIN(-)
4*
VOUT(-)
5†
SENSE(-)
6†
TRIM
7†
SENSE(+)
8*
VOUT(+)
† - Optional Pins
See Table 2
Hole and Pad diameter recommendations:
Pin Number
Hole Dia mm [in]
1, 2, 3, 5, 6, 7
1.6 [.063]
4, 8
2.2 [.087]
July 22, 2013
Pad Dia mm [in]
2.1 [.083]
3.2 [.126]
©2012 General Electric Company. All rights reserved.
Page 16
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Ordering Information
Please contact your GE Sales Representative for pricing, availability and optional features.
Table 1. Device Codes
Product codes
EBVW020A0B1Z
EBVW020A0B41Z
EBVW020A0B64Z
EBVW020A0B641Z
EBVW020A0B841Z
EBVW020A0B941Z
EBVW020A0B984Z
EBVW020A0B9641Z
EBVW020A0B41-HZ
EBVW020A0B64-HZ
EBVW020A0B641-HZ
EBVW020A0B9641-HZ
EBVW020A0B41-PHZ
July 22, 2013
Input Voltage
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
48V (3675Vdc)
Output Voltage
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
Output Current
20A
20A
20A
20A
20A
20A
20A
20A
20A
20A
20A
20A
20A
Efficiency
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
95.2%
©2012 General Electric Company. All rights reserved.
Connector Type
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Comcodes
150019309
CC10916750
150021139
CC10917246
150022307
CC10917236
150022795
150026416
CC10916751
150021143
150020433
CC10917231
CC10917233
Page 17
GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Table 2. Device Options
Contact Us
For more information, call us at
USA/Canada:
+1 888 546 3243, or +1 972 244 9288
Asia-Pacific:
+86.021.54279977*808
Europe, Middle-East and Africa:
+49.89.878067-280
India:
+91.80.28411633
www.ge.com/powerelectronics
July 22, 2013
©2012 General Electric Company. All rights reserved.
Version 1.21
Similar pages