APPLIED POWER CONVERSION Division of TECHNOLOGY DYNAMICS INC. NTDX-6000 SERIES 6000 WATT SINGLE OUTPUT SWITCHING POWER SUPPLIES 5.2” x 8” x 12.5” POWER FACTOR ACTOR CTOR CORRECTED CORRE APPLICATIONS The NTDX-6000 series of Power Factor Corrected AC-DC power supplies provides highly regulated bulk power to 6000 watts. Rugged construction and superior quality make this power supply ideal for harsh environment applications. Available in standard, modified or fully custom configurations, for industrial, commercial, COTS, ruggedized and Military applications. STANDARD FEATURES • • • • • • • • SPECIFICATIONS High Efficiency Up to 90% Active PFC for EN61000-3-2, -3 PF>0.95% AC Input 180-264 VAC 1Ø or 3Ø Built In DC Fan for Cooling Current Share Function AC & DC Good Signals Remote on/off & Remote Sense Functions 12V / 100 mA Auxiliary Output AVAILABLE OPTIONS • • • • • • • Hot Swap Parallel Operation ORing Diode for Redundant Operation Rack / Panel Mount Ruggedized for shock & vibration 400 Hz Operation Conformal Coated SAFETY AND EMISSIONS • • • • • Designed to meet UL/cUL60950-1 Designed to meet TUV EN60950-1 Designed to meet CB Report (IEC 60950-1) Designed to meet CE Mark (LVD) Designed to meet EN55022 Class B (CISPR 22 B) INPUT NPUT SPECIFICATIONS: Input:Universal AC Input Range 180-264VAC/254-370VDC Input Frequency: 47-63Hz Inrush Current: 60A at 230VAC (cold start) Input Current: 20A/180VAC,16A/230VAC Efficiency: 86-90% typical (depending on output model) Hold-up time: 10ms at full load (minimum) Leakage Current: <2.0 mA maximum @ 240 VAC Harmonics: EN 61000-3-2, -3 Class D Compliant (0.99 PF Typical) OUTPUT SPECIFICATIONS Adjustment Range: ± 10% (minimum) Minimum Load: none Regulation: Line ±0.5% Load ±0.5% Ripple/Noise: 150 - 200mV peak to peak maximum (20 MHz) Set Point Accuracy: ± 1%(except 5V = ±2%) (maximum) Output voltage adj: ±10% minimum Overcurrent Protection: 100-112% of rated output power. Overlvoltage Protection: 115 -150% of V1 nominal Overtemperature Protection: Heatsink Temp 90°C ± 5°C Auto Recovery. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: - 20°C to + 50°C. Storage Temperature: -40°C to + 85°C max Cooling: Internal ball bearing DC fan Humidity: 20-90% RH non condensing Vibration: 10 - 500Hz, 2G 10 min / 1cycle for 60 min (3 axes) Shock: 20 G Peak Acceleration Weight: Approx.: 17 LBS Size: 5.2” x 8” x 12.5” Design Excellence since 1976! MODEL SELECTION MODEL NUMBER VOLTAGE CURRENT NTDX-6000-12 NTDX-6000-24 12V 400A 24V NTDX-6000-28 NTDX-6000-48 28V 48V 250A 214A 124A NOTE: OTHER VOLTAGES & CURRENTS AVAILABLE. CONSULT THE FACTORY. OPTION DESIGNATIONS - HSP Hot Swap - MIL Ruggedized/Militarized - ORD Redundant Operation - PNL Panel Mount - PAR Parallel Operation - RK Rack Mount - CC Conformal Coating - 400Hz 400 Hz Operation MECHANICAL OUTLINE Rev.A SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE TECHNOLOGY DYNAMICS INC. 100 School Street, Bergenfield, NJ 07621 Phone: (201) 385-0500, Fax: (201) 385-0702 www.technologydynamicsinc.com