TAB NTDX-6000-12 Switching power supply Datasheet

APPLIED POWER CONVERSION
Division of
TECHNOLOGY DYNAMICS INC.
NTDX-6000 SERIES
6000 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
5.2” x 8” x 12.5”
POWER FACTOR
ACTOR
CTOR CORRECTED
CORRE
APPLICATIONS
The NTDX-6000 series of Power Factor
Corrected AC-DC power supplies provides
highly regulated bulk power to 6000 watts.
Rugged construction and superior quality
make this power supply ideal for harsh
environment applications. Available in
standard, modified or fully custom
configurations, for industrial, commercial,
COTS, ruggedized and Military applications.
STANDARD FEATURES
•
•
•
•
•
•
•
•
SPECIFICATIONS
High Efficiency Up to 90%
Active PFC for EN61000-3-2, -3 PF>0.95%
AC Input 180-264 VAC 1Ø or 3Ø
Built In DC Fan for Cooling
Current Share Function
AC & DC Good Signals
Remote on/off & Remote Sense Functions
12V / 100 mA Auxiliary Output
AVAILABLE OPTIONS
•
•
•
•
•
•
•
Hot Swap
Parallel Operation
ORing Diode for Redundant Operation
Rack / Panel Mount
Ruggedized for shock & vibration
400 Hz Operation
Conformal Coated
SAFETY AND EMISSIONS
•
•
•
•
•
Designed to meet UL/cUL60950-1
Designed to meet TUV EN60950-1
Designed to meet CB Report (IEC 60950-1)
Designed to meet CE Mark (LVD)
Designed to meet EN55022
Class B (CISPR 22 B)
INPUT
NPUT SPECIFICATIONS:
Input:Universal AC Input Range 180-264VAC/254-370VDC
Input Frequency: 47-63Hz
Inrush Current: 60A at 230VAC (cold start)
Input Current: 20A/180VAC,16A/230VAC
Efficiency: 86-90% typical (depending on output model)
Hold-up time: 10ms at full load (minimum)
Leakage Current: <2.0 mA maximum @ 240 VAC
Harmonics: EN 61000-3-2, -3 Class D Compliant (0.99 PF Typical)
OUTPUT SPECIFICATIONS
Adjustment Range: ± 10% (minimum)
Minimum Load: none
Regulation: Line ±0.5% Load ±0.5%
Ripple/Noise: 150 - 200mV peak to peak maximum (20 MHz)
Set Point Accuracy: ± 1%(except 5V = ±2%) (maximum)
Output voltage adj: ±10% minimum
Overcurrent Protection: 100-112% of rated output power.
Overlvoltage Protection: 115 -150% of V1 nominal
Overtemperature Protection: Heatsink Temp 90°C ± 5°C Auto Recovery.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature: - 20°C to + 50°C.
Storage Temperature: -40°C to + 85°C max
Cooling: Internal ball bearing DC fan
Humidity: 20-90% RH non condensing
Vibration: 10 - 500Hz, 2G 10 min / 1cycle for 60 min (3 axes)
Shock: 20 G Peak Acceleration
Weight: Approx.: 17 LBS
Size: 5.2” x 8” x 12.5”
Design Excellence since 1976!
MODEL SELECTION
MODEL NUMBER
VOLTAGE
CURRENT
NTDX-6000-12
NTDX-6000-24
12V
400A
24V
NTDX-6000-28
NTDX-6000-48
28V
48V
250A
214A
124A
NOTE: OTHER VOLTAGES & CURRENTS AVAILABLE. CONSULT THE FACTORY.
OPTION DESIGNATIONS
- HSP
Hot Swap
- MIL
Ruggedized/Militarized
- ORD
Redundant Operation
- PNL
Panel Mount
- PAR
Parallel Operation
- RK
Rack Mount
- CC
Conformal Coating
- 400Hz
400 Hz Operation
MECHANICAL OUTLINE
Rev.A
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
TECHNOLOGY DYNAMICS INC.
100 School Street, Bergenfield, NJ 07621
Phone: (201) 385-0500, Fax: (201) 385-0702
www.technologydynamicsinc.com