Series 61G AC High Performance Fans Ø 9,43’’ x 7,126’’ Ø 239,5 x 181 mm R&M speeds Approvals , NATO codification Life expectancy AC Motor Available with: L-10 LIFE AT 40°C: 25 000 hours Housing material: aluminium Impeller material: plastic Weight: 6,95 kg Bearing system: ball bearings - Safety switch - Terminal block - Aluminium impeller (62GR model) Airflow: CFM 61GM 3~ --- 1 ~ 50 Hz Non recommended zone Non recommended zone Static pressure: InH2O Static pressure: mmH2O 61GR Airflow: l/s Part Number 61GR116DC13 61GM116DC13 Nominal Noise Nominal Capacitor Input Nominal Starting voltage Airflow level speed Frequency Phases (not included) power Current Current Connection type V l/s dB(A) RPM Hz 220 380 220 380 220 380 220 380 275 275 275 275 318 318 318 318 72 72 72 72 74 74 74 74 2750 2750 2750 2750 3300 3300 3300 3300 50 50 50 50 60 60 60 60 µF 3 3 1 1 3 3 1 1 6,9 2,2 10 3,2 W mA mA Leads 100 100 105 105 160 160 166 166 400 230 480 280 690 400 780 450 1750 1000 1500 900 2600 1500 2100 1200 X X X X X X X X Additional versions: Accessories: Salt spray protected - Shock and vibration protected - Marine specifications Wide temperature range - Other voltages (consult factory) Refer to Accessories leaflet http://www.etrinet.com e-mail: [email protected] Terminals Operating temperature Min.°C -10 -10 -10 -10 -10 -10 -10 -10 Max.°C 70 70 70 70 70 70 70 70 ETRI is a trademark of ECOFIT Non contractual document. Specifications are subject to change without prior notice. Pictures for information only. Edition 2008