BEL 07LC-10T

ISOLATED DC/DC CONVERTERS
48V Input / 5V/2A or 12V/1A or 24V/0.5A Output
07LC-10T Series
•
Isolated
•
Low Cost
•
High Efficiency
•
OCP/SCP
•
High Power Density
•
Excellent Thermal Performance
•
Output Over-voltage Protection
Description
The 07LC-10T Series converters are isolated DC/DC converters that operate from a nominal 48V source.
These converters provide up to 12W of output power. These units are designed to be highly efficient and costeffective. Features include remote on/off, short circuit protection, over-current protection, and output overvoltage protection. These converters are provided in a compact, industry standard package.
Part Selection
Output
Voltage
5V
12V
24V
Input Voltage
Max. Output
Current
2A
1A
0.5A
36 – 72V
36 – 72V
36 – 72V
Max. Output
Power
10W
12W
12W
Typical
Efficiency
82%
83%
85%
Model Number
07LC-10T050
07LC-10T120
07LC-10T240
Note: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
Input Voltage (peak/surge)
Remote On/Off (Active Low)
Min
-0.3V
-0.3V
Typ
-
Max
72V
100V
18V
Remote On/Off (Active High)
Output Power
Ambient Temperature
Storage Temperature
-0.3V
0°C
-40°C
-
7V
12W
70°C
125°C
Notes
100ms non-repetitive
Input Specifications
Parameter
Input Voltage
Input Current (no load)
Input Current (full load)
Remote Off Input Current (Active Low)
Remote Off Input Current (Active High)
Input Reflected Ripple Current
(pk-pk)
Min
36V
-
Typ
25mA
5mA
-
Max
72V
40mA
0.45 A
10mA
10mA
-
15mA
30mA
Input Reflected Ripple Current
(RMS)
-
5mA
10mA
I2t Inrush Current Transient
Turn-on Voltage Threshold
-
0.039A2s
30V
0.062A2s
-
Notes
Tested with simulated source
impedance of 10uH, 5Hz to 20MHz;
use a 47uF/100V electrolytic
capacitor with ESR = 1 ohm max. at
200KHz at 25°C
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input / 5V/2A or 12V/1A or 24V/0.5A Output
Output Specifications
Parameter
Output Voltage Set Point
Min
Typ
Max
VO=5V
VO=12V
VO=24V
4.850V
11.64V
23.28V
5.00V
12.00V
24.00V
5.150V
12.36V
24.72V
VO=5V
VO=12V
VO=24V
-
10mV
20 mV
35 mV
15 mV
36 mV
48 mV
VO=5V
VO=12V
VO=24V
Regulation Over Temperature (0°C to 70°C)
-
15mV
36 mV
48 mV
75mV
25 mV
60 mV
80 mV
150mV
VO=5V
VO=12V
VO=24V
0.2A
0.1A
0.05A
-
2A
1A
0.5A
VO=5V
VO=12V
VO=24V
-
3A
1.5A
0.75A
TBD
-
VO=5V
VO=12V
VO=24V
-
18mV
21mV
45mV
30mV
40mV
70mV
VO=5V
VO=12V
VO=24V
-
60mV
80mV
120mV
2mS
0%
100mV
120mV
180mV
3%
VO=5V
VO=12V
VO=24V
0uF
0uF
0uF
-
800uF
100uF
20uF
-
100mV
100uS
100mV
100uS
150mV
150uS
150mV
150uS
350mV
200uS
350mV
200uS
150mV
150uS
150mV
150uS
250mV
200uS
250mV
200uS
500mV
250uS
500mV
250uS
Line Regulation
Load Regulation
Notes
Vin=48V for all outputs
Output Current
Current Limit Threshold
(VO= 90% VO, nom)
Short Circuit Surge Transient
Ripple and Noise (RMS)
Ripple and Noise (pk-pk)
Turn on Time
Overshoot at Turn on
Output Capacitance
A2s
0 - 20MHz Bandwidth
with 1uF ceramic load
capacitance
0 - 20MHz Bandwidth
with 1uF ceramic load
capacitance
Transient Response
50% ~ 100%
Max Load
100% ~ 50%
Max Load
50% ~ 100%
Max Load
100% ~ 50%
Max Load
50% ~ 100%
Max Load
100% ~ 50%
Max Load
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
VO=5V
VO=12V
VO=24V
di/dt = 0.1A/uS; Vin =
48V; Ta = 25°C and 1uF
ceramic capacitance
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input / 5V/2A or 12V/1A or 24V/0.5A Output
General Specifications
Parameter
Min
Typ
Max
78%
79%
81%
200KHz
95%VO
82%
83%
85%
250KHz
-
300KHz
105%VO
-
6.8V
15V
30V
-
Notes
Efficiency
VO=5V
VO=12V
VO=24V
Switching Frequency
Output Trim Range
Protection Features
Overvoltage Protection Setpoint
VO=5V
VO=12V
VO=24V
MTBF
Vin=48V, IO= IO, max
For all outputs
Calculated Per Bell Core TR-332 (IO =
Nomal; Ta = 25°C)
2,000,000 hours
Isolation
Dimensions
-
Inches (L × W × H)
Millimeters (L × W × H)
Weight
-
1500 V
-
1.91 x 0.98 x 0.477
48.51 x 24.89 x 12.12
10.3g
-
Note: All specifications are typical at 25°C unless otherwise stated.
Control Specifications
Parameter
Remote On/Off
Signal Low (Unit On)
Active Low
Signal High (Unit Off)
Signal Low (Unit Off)
Active High
Signal High (Unit On)
Min
Typ
Max
Notes
-0.3V
2.4V
-0.3V
2.4V
-
0.8V
18V
0.8V
7V
The remote on/off pin open, Unit On.
Output Trim Equations
Equations for calculating the trim resistor (in kΩ) given the desired adjusted voltage (Vadj) and the nominal
output voltage of the converter (Vnom) are shown below. The Trim Down resistor should be connected between
the Trim pin and Vout. The Trim Up resistor should be connected between the Trim pin and Ground. Only one of
the resistors should be used for any given application.
Vout
Rtrimdown
Module
Trim
TrimDown
nom
adj
GND
=
R
RTrimUp =
V
Vadj
A
−V
−B
C
−D
− Vnom
Vout
Module
Trim
GND
Rtrimup
Vnom
A
B
C
D
24
12
5
489.490
113.550
56.410
28.310
16.990
51.200
26.660
13.020
18.228
6.810
6.490
36.500
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input / 5V/2A or 12V/1A or 24V/0.5A Output
Efficiency Data
90.00%
75.00%
EFFICIENCY
80.00%
36V
70.00%
48V
65.00%
72V
60.00%
55.00%
50.00%
0.00
0.50
1.00
1.50
90.00%
85.00%
80.00%
75.00%
70.00%
65.00%
60.00%
55.00%
50.00%
0.00
2.00
36V
48V
72V
0.20
0.40
0.60
0.80
1.00
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
07LC-10T050
07LC-10T120
90.00%
85.00%
80.00%
EFFICIENCY
EFFICIENCY
85.00%
75.00%
36V
70.00%
48V
72V
65.00%
60.00%
55.00%
50.00%
0.05
0.13
0.25
0.38
0.50
OUTPUT CURRENT
07LC-10T240
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input / 5V/2A or 12V/1A or 24V/0.5A Output
Thermal Derating Curves
Vo=5V, Io=2A
Vo=12V, Io=1A
Vo=24V, Io=0.5A
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input / 5V/2A or 12V/1A or 24V/0.5A Output
Pin Connections
Pin
Function
1
Vin+
2
Vin-
3
Remote On/Off
4
Vo+
5
Trim
6
Vo-
Note: Remote On/Off pin open,
unit on.
©2004 Bel Fuse Inc. Specifications subject to change without notice. 120304
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com