Pulse A1801 Common mode choke Datasheet

COMMON MODE CHOKE
For Fibre Channel, Gigabit Ethernet,
and IEEE 1394 Applications
Common Mode Attenuation from 200 MHz to 2.5 GHz
Reduces radiated emissions and improves noise immunity
235°C Peak Reflow temperature rating
Surface mount, auto-insertable package
Industrial temperature range
Electrical Specifications @ 25°C — Operating Temperature -40°C to +85°C
Part
Number
A1801
200 MHz
-11.0
500MHz
-11.0
Common Mode Attenuation
(dB TYP)
1.0GHz
1.5GHz
-11.0
-10.0
2.0GHz
-9.0
Primary Inductance
OCL
(µH MIN)
3.0
2.5GHz
-7.5
Mechanical
DCR
(Ω MAX)
.15
Schematic
A1801
1.50
3,81
.075
1,90
.290 MAX
7,37
.050
1,27
.340 .190
8,64 4,83
.240
MAX
6,10
Date Code
Rev
Country of Origin
.030
0,76
1
8
4
5
.150
MAX
3,81
.035
8X
0,89
Dimensions: Inches
mm
Unless otherwise specified, all tolerances are ± .005
0,13
.004 / 0,10
8 SURFACES
.050
1,27 TYP
Weight . . . . . . .0.2 grams (max)
Tape & Reel . . . . . . . .1750/reel
Tube . . . . . . . . . . . . . . .80/tube
US 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 6287 8998 • Taiwan 886 2 2698 0228 • Hong Kong 852 2788 6588 • http://www.pulseeng.com
A104.A (1/04)
COMMON MODE CHOKE
For Fibre Channel, Gigabit Ethernet,
and IEEE 1394 Applications
Application Notes:
1. Values for R1 and R2 are determined by system transmit
amplitude requirements. A value of 0Ω for R1 and R2 will
yield an output with maximum amplitude but distorted due to
impedance mismatch. A value of 68Ω will provide an
optimum waveform but have 6.0 dB insertion loss. If 6.0dB
loss is too great, select at least 15Ω to obtain a reasonable
compromise between insertion loss and waveshape. The
typical value for C1, C2, C3, and C4 is 0.1µF.
2. To maintain return loss and signal integrity, transmission line
methods must be used when designing the PCB. For best
performance the common mode choke should be located no
more than 1" from the cable connector.
3. One example of a possible layout is shown below for a Fibre
Channel application. Note that actual board layouts will vary
based upon specific applications and EMC considerations.
Typical Fibre Channel 150 Ω Application:
C3
GND
Vcc
EARTH GND
GND
120 200
R1
C1
120 200
R2
C2
TX+
A1801
TX+
TX-
SERDES
CHIP SET
Vcc
DATE
75 W
Transmission Lines
RX-
A1801
150
RX+
HSDCC
or
DB9
CONNECTOR
TX-
GND
C3
RX-
REV
DATE
C4
REV
RX+
EARTH GND
GND
C4
Test Circuit, Common Mode Attenuation:
D.U.T.
75 W
NETWORK
ANALYZER
For More Information :
UNITED STATES
(Worldwide)
UNITED KINGDOM
(Northern Europe)
FRANCE
SINGAPORE
(Southern Europe) (Southern Asia)
TAIWAN, R.O.C.
(Northern Asia)
HONG KONG
(China/Hong Kong)
12220 World Trade Drive
San Diego, CA 92128
U.S.A.
http://www.pulseeng.com
TEL: 858 674 8100
FAX: 858 674 8262
1 & 2 Huxley Road
The Surrey Research Park
Guildford, Surrey GU2 5RE
United Kingdom
TEL: 44 1483 401700
FAX: 44 1483 401701
Zone Industrielle
F-39270
Orgelet
France
TEL: 33 3 84 35 04 04
FAX: 33 3 84 25 46 41
3F-4, No. 81, Sec. 1
HsinTai Wu Road
Hsi-Chih, Taipei Hsien
Taiwan, R.O.C.
Tel: 886 2 2698 0228
FAX: 886 2 2698 0948
9/F, Phase 2, Tai Sang
Shatin Warehouse Centre
6 Wong Chuk Yeung Street
Fotan, Shatin, Hong Kong
TEL: 852 2788 6588
FAX: 852 2776 1055
150 Kampong Ampat
#07-01/02
KA Centre
Singapore 368324
TEL: 65 6287 8998
FAX: 65 6280 0080
DISTRIBUTOR
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product
names mentioned herein may be trademarks or registered trademarks of their respective owners.
Printed on recycled paper. ©2004, Pulse Engineering, Inc.