MPD A324RW Wide input range, 3w single & dual output dc/dc converter Datasheet

A300RW Series
Wide Input Range, 3W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 3W Output Power
• UL Approved (File E245422)
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Compact DIP Case
• Single & Dual Outputs
• 28 Standard Models
• 1.0 MH MTBF
• Industry Standard Pin-Out
RoHS Compliant
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Input
Parameter
Input Start Voltage
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
5 VDC Input
3.5
12 VDC Input
4.5
24 VDC Input
8.0
48 VDC Input 16.0
π (Pi) Filter
Typ.
4.0
7.0
12.0
24.0
Max.
4.5
9.0
18.0
36.0
Units
1,000
1.0
2,000
A
mW
Typ.
±0.5
±0.5
±0.2
±0.2
45
Max.
±1.0
±2.0
±0.5
±0.5
60
100
15
300
±3.0
±0.01
Continuous (Autorecover)
500
±5.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/ºC
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
Over Line, Load & Temp.
120
50% Load Step Change
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
Typ.
Max.
65
300
100
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
VDC
Units
VDC
MΩ
pF
kHz
Max.
+71
+90
+125
Units
ºC
ºC
ºC
95
%
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Non-Conductive Black Plastic (UL-94V0)
0.42 Oz (12g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
Units
MHours
Max.
11.0
25.0
50.0
100.0
260
2,500
Units
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Current (mA)
Voltage (VDC)
Model
Number
Nominal
Range
Full-Load
5
5
5
5
5
5
5
12
12
12
12
12
12
12
24
24
24
24
24
24
24
48
48
48
48
48
48
48
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
566
685
779
779
694
800
800
223
267
305
305
271
313
313
109
132
149
149
132
152
152
55
66
75
75
65
75
75
Output
Reflected
Efficiency
Current
Ripple Voltage Current
(%, Typ)
(VDC) (mA, Max) (mA, Min)
No-Load Current
Fuse Rating
Slow-Blow
(mA)
(mA, Typ)
A301RW
A302RW
A303RW
A304RW
A305RW
A306RW
A307RW
A311RW
A312RW
A313RW
A314RW
A315RW
A316RW
A317RW
A321RW
A322RW
A323RW
A324RW
A325RW
A326RW
A327RW
A331RW
A332RW
A333RW
A334RW
A335RW
A336RW
A337RW
40
40
40
40
40
40
40
20
20
20
20
20
20
20
5
5
5
5
5
5
5
3
3
3
3
3
3
3
100
100
100
100
100
100
100
30
30
30
30
30
30
30
15
15
15
15
15
15
15
10
10
10
10
10
10
10
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from
each output to common for dual output units. For noise sensitive applications, the use
of 3.3 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change of 75%
to 100%.
3. Operation at no-load will not damage these units. However, they may not meet all
specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To
do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and
float the output common.
5. The converter should be connected to a low ac-impedance source. An input source with
a highly inductive impedance may affect the stability of the converter. In applications
where the converter output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be mounted
close to the converter. For 5V input units a 8.2 µF is recommended, for 12V input units,
a 3.3 µF; and for 24V & 48V units a 2.2 µF.
6. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
600.0
500.0
250.0
200.0
±250.0
±125.0
±100.0
600.0
500.0
250.0
200.0
±250.0
±125.0
±100.0
600.0
500.0
250.0
200.0
±250.0
±125.0
±100.0
600.0
500.0
250.0
200.0
±250.0
±125.0
±100.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
70
73
77
77
72
75
75
74
78
82
82
77
80
80
76
79
84
84
79
82
82
76
79
84
84
80
84
84
1,500
1,500
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
700
700
350
350
350
350
350
350
350
135
135
135
135
135
135
135
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
2, 3
9
11
-Vin
No Pin
NC
-Vin
Common
-Vout
14
16
22, 23
+Vout
-Vout
+Vin
+Vout
Common
+Vin
NC: No Connection
Capacitive Load
Single Output
Dual Output
4,000 µF Max
±1,000 µF Max
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Leads are gold plated for improved
solderability.
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]