TOKO A926AY-680K

Fixed Inductors for Surface Mounting
づ
け
面実装用 固定インダクタ
D10FS
Inductance Range: 10~1200µH
Recommended patterns
推奨パターン図
DIMENSIONS/外形寸法図
12.0
8.6
2.8
3.5 Max.
1.05 1.0
方向表示
Direction indication
2.3 1.7
1.7 2.3
9.0
11.5 Max.
9.7 Max.
(Unit: mm)
(Unit: mm)
FEATURES/特長
• Low profile (9.7×11.5mm Max. square and 3.5mm Max.
height).
• Suitable for large current.
• Ideal for CCFL driving inverter circuit applications.
• RoHS compliant.
•
•
•
•
薄形構造(9.7×11.5mm 角Max.、高さ3.5mm Max.)
大電流対応
各種機器の冷陰極管駆動回路用
RoHS指令対応
SELECTION GUIDE FOR STANDARD COILS
TYPE D10FS (Quantity/reel; 500 PCS)
東光品番
TOKO
Part
Number
#A926AY-100M
#A926AY-120M
#A926AY-150M
#A926AY-180M
#A926AY-220M
#A926AY-270M
#A926AY-330M
#A926AY-390M
#A926AY-470K
#A926AY-560K
#A926AY-680K
#A926AY-820K
#A926AY-101K
#A926AY-121K
#A926AY-151K
#A926AY-181K
#A926AY-221K
#A926AY-271K
#A926AY-331K
#A926AY-391K
#A926AY-471K
#A926AY-561K
#A926AY-681K
#A926AY-821K
#A926AY-102K
#A926AY-122K
インダクタンス(1)
許容差
直流抵抗(2)
最大許容電流(3)
Inductance(1)
L (µH)
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
1200
Tolerance
(%)
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
DC Resistance(2)
(Ω) Max.
0.051
0.059
0.070
0.082
0.10
0.13
0.15
0.18
0.21
0.25
0.29
0.34
0.41
0.48
0.59
0.70
0.84
1.05
1.30
1.50
1.80
2.20
2.60
3.20
3.90
4.60
Rated
DC Current(3)
(A) Max.
2.15
2.00
1.80
1.65
1.50
1.35
1.22
1.14
1.04
0.94
0.88
0.78
0.72
0.66
0.58
0.53
0.48
0.42
0.38
0.35
0.32
0.29
0.26
0.23
0.21
0.19
(1) Inductance is measured with a LCR meter 4284A (Agilent Technologies)
or equivalent.
Test frequency at 100kHz
(2) DC resistance is measured with a Digital Multimeter TR6871 (Advantest)
or equivalent.
(3) Maximum allowable DC current is that which causes a 10% inductance
reduction from the initial value, or coil temperature to rise by 40°C
whichever is smaller.(Reference ambient temperature: 20°C)
(1) インダクタンスはLCRメータ4284A(Agilent Technologies)または同等品により測
定する。
測定周波数は100kHzです。
(2) 直流抵抗はデジタルマルチメータTR6871(Advantest)または同等品により測定す
る。
(3) 最大許容電流は、直流重畳電流を流した時インダクタンスの値が初期値より10%減
少する直流電流値、または直流電流により、コイルの温度が40℃上昇の何れか小さ
い値です。(周囲温度20℃を基準とする。
)