AC60 Single
Rev A January 2007
AC-DC Switching Power Module
AC60 series
APPLICATION NOTE
Rev A
Page 1
®
AC60 Single
1400 PROVIDENCE HIGHWAY • BUILDING 2
Rev A January 2007
NORWOOD, MASSACHUSETTS 02062-5015
Content
1. INTRODUCTION
2. AC60 SERIES CONVERTER FEATURES
3. TECHNICAL SPECIFICATIONS
4. MAIN FEATURES AND FUNCTIONS
3
3
4
5
4.1 Operating Temperature Range
5
4.3 Output Protection
5
5. SAFETY
6. APPLICATIONS
5
5
6.1 Power De-Rating Curve
5
6.2 Test Set-Up
6
6.3 Output Ripple and Noise Measurement
6
6.4 Installation Instruction
6
7. AC60 SERIES MECHANICAL OUTLINE DIAGRAMS
8. PART NUMBER
7
8
Page 2
®
AC60 Single
1400 PROVIDENCE HIGHWAY • BUILDING 2
Rev A January 2007
NORWOOD, MASSACHUSETTS 02062-5015
1. Introduction
2. AC60 series Converter Features
This application note describes the features and functions of Intronics
AC60 series of open frame, switching AC-DC power module. These
are highly efficient, reliable and compact, high power density, single
output AC/DC power module. The module is fully protected against
short circuit and over-voltage conditions. Intronics world class
automated manufacturing methods, together with an extensive testing
and qualification program; ensure that the AC60S480 power module
is extremely reliable.
•
60W Isolated Output
• High Efficiency Up to 88%
• Fixed Switching Frequency
• Universal Input Range
• Regulated Output
• Continuous Short Circuit Protection
•
2” X 4” size, low profile
• Open-Frame Type
Page 3
®
AC60 Single
1400 PROVIDENCE HIGHWAY • BUILDING 2
Rev A January 2007
NORWOOD, MASSACHUSETTS 02062-5015
3. Technical Specifications
(All specifications are typical at nominal input, full load at 25℃ unless otherwise noted.)
PARAMETER
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Operating Temperature
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Voltage Range
Input Frequency Range
Maximum Input Current
Leakage Current
Inrush Current
OUTPUT CHARACTERISTIC
Output Voltage Set Point
NOTES and CONDITIONS
Device
1 minute
Typical
Units
90
0
-20
4242
264
+50
+85
Vac
℃
℃
Vdc
100
47
240
63
Vac
Hz
A
mA
A
1.4
3.5
50
Vin=264Vac, cold start at 250C.
AC60S033
AC60S050
AC60S090
AC60S120
AC60S150
AC60S240
AC60S280
AC60S360
AC60S480
AC60S033
AC60S050
AC60S090
AC60S120
AC60S150
AC60S240
AC60S280
AC60S360
AC60S480
Vin=Nominal Vin , Io=Io.max, Tc=25℃
Holdup Time
Vin=115Vac
Output Voltage Regulation
Load Regulation
Line Regulation
10% load to Full load
Vin=high line to low line
Output Voltage Ripple and Noise
20MHz bandwidth
ISOLATION CHARACTERISTICS
Input to Output
Input to Earth
Output to Earth
Isolation Resistance
Max.
100% Load, Vin=90Vac
Operating Output Current Range
Peak-to-Peak
Min.
Full load, 0.1uF ceramic and
capacitor
3.26
4.95
8.91
11.88
14.85
23.76
27.72
35.64
47.52
3.3
5.0
9.0
12.0
15.0
24.0
28.0
36.0
48.0
8
8
6.67
5
4
2.5
2
1.67
1.25
8
3.33
5.05
9.09
12.12
15.15
24.24
28.28
36.36
48.48
Vdc
A
mS
±1.0
±0.5
10uF E.L
%
%
AC60S033
AC60S050
AC60S090
AC60S120
50
50
90
120
AC60S150
AC60S240
AC60S280
AC60S360
AC60S480
150
240
280
360
480
mV
4242
2121
707
Vdc
Vdc
Vdc
MΩ
1 minute
1 minute
1 minute
100
FEATURE CHARACTERISTICS
Switching Frequency
60
KHz
GENERAL SPECIFICATIONS
MTBF
Weight
Io=100%of
Io.max;Ta=25
MIL-HDBK-217F
℃
per
TBD
0.175
M hours
Kg
Page 4
®
1400 PROVIDENCE HIGHWAY • BUILDING 2
NORWOOD, MASSACHUSETTS 02062-5015
AC60 Single
R ev A January 2007
4. Main Features and Functions
6. Applications
4.1 Operating Temperature Range
6.1 Power De-Rating Curve
Intronics AC60 series power modules, which highly efficient
design, has resulted in its ability to operate ambient temperature
environment (0℃ to 50℃). Due to consideration must be given to
the de-rating curves when ascertaining maximum power that can
be drawn from the power module. The maximum power drawn is
influenced by a number of factors, such as:
•
Input voltage range.
•
Output load current.
•
These can be effective heat sinks for the power module.
4.3 Output Protection
The power modules provide a full continuous short-circuit
protection. The unit will auto recover once the short circuit is
removed. To provide protection in a fault condition, the unit is
equipped with internal over-current protection. The unit will
operate normally once the fault condition is removed. The power
module will go to hiccup mode if the output current or voltage is
set from 110% to 150% of rated current or voltage.
5. Safety
CB
TUV
Approval
Approval
UL
Approval
CE
Approval
Page 5
®
AC60 Single
1400 PROVIDENCE HIGHWAY • BUILDING 2
NORWOOD, MASSACHUSETTS 02062-5015
Rev A January 2007
6.2 Test Set-Up
6.3 Output Ripple and Noise Measurement
The basic test set-up to measure parameters such as efficiency and
The test set-up for noise and ripple measurements is shown in Figure 2.
load regulation is shown in Figure 1. When testing the Intronics AC60
Measured method :
series under any transient conditions, please ensure that the
Add a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor to
output at 20 MHz Band Width.
transient response of the source is sufficient to power the equipment
under test. We can calculate the
•
Efficiency
•
Load regulation and line regulation.
Terminal wire 800mmMin
The value of efficiency is defined as:
AC
Vo ×
η=
Io
× 100%
Pin
Where:
Supply
+Vo
+
N
Load
Oscilloscope
0.1uF
-Vo
10uF/100V
Vo is output voltage,
AC60S Series
Io is output current,
Figure 2. Output Voltage Ripple and Noise Measurement Set-Up
Pin is input power,
The value of load regulation is defined as:
6.4 Installation Instruction
V FL -V
Load reg = NL
× 100%
V
L
Please use the mounting hold as:
AC60 series :
4 holds of ψ3.17
And insert the spacer (Maxψ6) of height over 8mm to lift the unit .The
vibration spec. is the value take when the unit is raised by 8mm spacers.
NL
Where VFL is the output voltage at full load
VNL is the output voltage at 10% load
The value of line regulation is defined as:
−
Line reg = V HL
V
V LL
LL
× 100%
Where VHL is the output voltage of maximum input voltage at full load.
VLL is the output voltage of minimum input voltage at full load.
AC
L
+Vo
N
-Vo
V
Pin
Supply
A
Load
+
Figure 1. AC60 Series Test Setup
Page 6
®
1400 PROVIDENCE HIGHWAY • BUILDING 2
NORWOOD, MASSACHUSETTS 02062-5015
Please reserve 4mm space from the surfaces and the sides of
PCB, especially from the solder surface, 8mm space is necessary. If
the space is not enough, the specification of insulation and
withstand will not be satisfied.
AC60 Single
Rev A January 2007
7.AC60 Series Mechanical Outline
Diagrams
Dimensions are in millimeters
Tolerance: x.x ±0.5mm, unless otherwise noted
Annotations:All models height does not exceed 34mmMAX .
FG should be connected to the earth terminal of the apparatus. If not,
the conducted noise and output noise will increase.
Figure 6. AC60 series Mechanical Outline Diagram
Page 7
®
AC60 Single
1400 PROVIDENCE HIGHWAY • BUILDING 2
Rev A January 2007
NORWOOD, MASSACHUSETTS 02062-5015
8. Part Number
AC XX S XXX
AC SERIES
60:
Supply Max. Power
S:Single Output
•
•
•
•
•
•
•
•
•
033:Output Voltage3.3 VDC
050:Output Voltage 5.0 VDC
090:Output Voltage 9.0 VDC
120:Output Voltage 12 VDC
150:Output Voltage 15 VDC
240:Output Voltage 24 VDC
280:Output Voltage 28 VDC
360:Output Voltage 36 VDC
480:Output Voltage 48 VDC
Page 8