AD8 / AD9 Series Ultrasonic air bubble and air-in-line sensors FEATURES · Non-invasive pulse-type ultrasonic technology · Compact design features integral programmable micro-controller · High accuracy and reliability · Dry coupled, no coupling gel required · Output signal not affected by fluid or tubing colour · High EMI and RFI noise immunity SPECIFICATIONS ELECTRICAL CONNECTION Maximum ratings Supply voltage (VS) Supply current without LED with LED Temperature limits Storage Operating 5 VDC (± 10%) RED 15 mA 24 mA BLACK Ground GREEN Self-Test Sensor -20 ... 85 °C 5 ... 60 °C ORANGE Humidity limits Input DC Voltage CMOS Logic Output 0 - 95 %RH (non-condensing) Note: Self-Test provides an electronic check for false wet output signals. Connect to Ground for normal operation. August 2007 / 301 1/3 www.sensortechnics.com AD8 / AD9 Series Ultrasonic air bubble and air-in-line sensors PERFORMANCE CHARACTERISTICS Characteristics Min. Typ. Max. Logic low voltage Units 0.5 V VS - 0.5 Logic high voltage Output sink current (output low) 5 Output source current (output high) 5 Response time mA wet to dry 0.215 dry to wet 46 ms OUTLINE DRAWING D H A E H B G C F Threaded holes 4-40 x 0.22 (5.59) Wires Dimensions Part no. AD8...01 AD...02 AD9...4M AD...03 AD...04 AD9...06 AD9...08 AD9...10 Tubing siz e 1/16" O.D. 1/8" O.D. 4 mm O.D. 3/16" O.D. 1/4" O.D. 3/8" O.D. 1/2" O.D. 5/8" O.D. A 0.045 0.100 0.125 0.150 0.200 0.310 0.430 0.520 B 0.150 0.325 0.350 0.315 0.400 0.525 0.750 0.850 C1 0.750 0.620 0.650 0.650 0.700 0.825 1.050 1.150 D 1.12 E 0.80 F 0.88 G 0.55 H 0.165 1.00 0.75 0.75 0.50 0.125 Note: 1. The following products come with an extension base which adds another 0.30 inches to dimension C: AD8...02, ...03, ...04 AD9...4M, ...08, ...10 all dimensions in inches August 2007 / 301 2/3 www.sensortechnics.com AD8 / AD9 Series Ultrasonic air bubble and air-in-line sensors ORDERING INFORMATION Series Options AD Design type 8 9 Options for rigid tubing 0000 without LED, 36 inch cable for soft tubing 0001 with LED, 36 inch cable Application Tubing siz e E End of sample 01 1/16 inch O.D. B Bubble size equal to tube I.D. 02 1/8 inch O.D. 4M 4 mm O.D. 03 3/16 inch O.D. 04 1/4 inch O.D. 06 3/8 inch O.D. 08 1/2 inch O.D. 10 5/8 inch O.D. S Bubble size down to 50 % of tube I.D. Notes: 01: only as AD8-...E01 4M: only as AD9-... 06: only as AD9-0000... 08: only as AD9-0000... 10: only as AD9-0000-E... Example: Notes: AD 9 - 0000 - B 4M Sensortechnics is asking customers for a sample of their tubing. The sensor will then be calibrated for exactly this tubing. For proper function the sensor should only be used with the tubing which was sent to Sensortechnics! Custom specific modifications are widely available. Please contact your nearest Sensortechnics sales office for further information. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. August 2007 / 301 3/3 www.sensortechnics.com