AD AD9985BSTZ-110

110 MSPS/140 MSPS Analog Interface for
Flat Panel Displays
AD9985
FUNCTIONAL BLOCK DIAGRAM
FEATURES
APPLICATIONS
AUTO CLAMP
LEVEL ADJUST
RAIN
8
ROUTA
AUTO CLAMP
LEVEL ADJUST
GAIN
A/D
CLAMP
8
GOUTA
AUTO CLAMP
LEVEL ADJUST
BAIN
A/D
CLAMP
8
CLAMP
FILT
DTACK
SYNC
PROCESSING
AND CLOCK
GENERATION
HSOUT
VSOUT
SOGOUT
SOGIN
REF
SCL
SDA
BOUTA
MIDSCV
HSYNC
COAST
RGB graphics processing
LCD monitors and projectors
Plasma display panels
Scan converters
Microdisplays
Digital TV
A/D
CLAMP
SERIAL REGISTER AND
POWER MANAGEMENT
A0
REF
BYPASS
AD9985
04799-0-001
Automated clamping level adjustment
140 MSPS maximum conversion rate
300 MHz analog bandwidth
0.5 V to 1.0 V analog input range
500 ps p-p PLL clock jitter at 110 MSPS
3.3 V power supply
Full sync processing
Sync detect for hot plugging
Midscale clamping
Power-down mode
Low power: 500 mW typical
4:2:2 output format mode
Figure 1.
GENERAL DESCRIPTION
The AD9985 is a complete 8-bit, 140 MSPS, monolithic analog
interface optimized for capturing RGB graphics signals from
personal computers and workstations. Its 140 MSPS encode rate
capability and full power analog bandwidth of 300 MHz
support resolutions up to SXGA (1280 × 1024 at 75 Hz).
The AD9985 includes a 140 MHz triple ADC with internal
1.25 V reference, a PLL, and programmable gain, offset, and
clamp control. The user provides only a 3.3 V power supply,
analog input, and Hsync and COAST signals. Three-state
CMOS outputs may be powered from 2.5 V to 3.3 V.
The AD9985’s on-chip PLL generates a pixel clock from the
Hsync input. Pixel clock output frequencies range from 12 MHz
to 140 MHz. PLL clock jitter is 500 ps p-p typical at 140 MSPS.
When the COAST signal is presented, the PLL maintains its
output frequency in the absence of Hsync. A sampling phase
adjustment is provided. Data, Hsync, and clock output phase
relationships are maintained. The AD9985 also offers full sync
processing for composite sync and sync-on-green applications.
A clamp signal is generated internally or may be provided by
the user through the CLAMP input pin. This interface is fully
programmable via a 2-wire serial interface.
Fabricated in an advanced CMOS process, the AD9985 is
provided in a space-saving 80-lead LQFP surface-mount
plastic package and is specified over the –40°C to +85°C
temperature range.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
www.analog.com
Tel: 781.329.4700
Fax: 781.326.8703
© 2004 Analog Devices, Inc. All rights reserved.
AD9985
TABLE OF CONTENTS
Revision History ........................................................................... 2
2-Wire Serial Register Map ....................................................... 16
Specifications..................................................................................... 3
2-Wire Serial Control Register Detail Chip Identification... 19
Explanation of Test Levels........................................................... 6
PLL Divider Control .................................................................. 19
Absolute Maximum Ratings............................................................ 7
Clock Generator Control .......................................................... 19
ESD Caution.................................................................................. 7
Clamp Timing............................................................................. 20
Pin Configuration and Function Descriptions............................. 8
Hsync Pulsewidth....................................................................... 20
Design Guide................................................................................... 11
Input Gain ................................................................................... 20
General Description................................................................... 11
Input Offset ................................................................................. 20
Digital Inputs .............................................................................. 11
Mode Control 1 .......................................................................... 21
Input Signal Handling................................................................ 11
2-Wire Serial Control Port........................................................ 26
Hsync, Vsync Inputs................................................................... 11
Data Transfer via Serial Interface............................................. 26
Serial Control Port ..................................................................... 11
Sync Slicer.................................................................................... 28
Output Signal Handling............................................................. 11
Sync Separator ............................................................................ 28
Clamping ..................................................................................... 11
PCB Layout Recommendations ............................................... 29
RGB Clamping........................................................................ 11
Analog Interface Inputs ............................................................. 29
YUV Clamping ....................................................................... 12
Power Supply Bypassing ............................................................ 29
Gain and Offset Control............................................................ 12
PLL ............................................................................................... 30
Auto Offset .............................................................................. 12
Outputs (Both Data and Clocks).............................................. 30
Sync-on-Green............................................................................ 13
Digital Inputs .............................................................................. 30
Clock Generation ....................................................................... 13
Voltage Reference ....................................................................... 30
Power Management.................................................................... 14
Outline Dimensions ....................................................................... 31
Timing.......................................................................................... 15
Ordering GuIde .......................................................................... 31
Hsync Timing ............................................................................. 15
Coast Timing............................................................................... 15
REVISION HISTORY
5/04—Revision 0: Initial Version
Rev. 0 | Page 2 of 32
AD9985
SPECIFICATIONS
Analog Interface: VD = 3.3 V, VDD = 3.3 V, ADC clock = maximum conversion rate, unless otherwise noted.
Table 1.
AD9985KSTZ-110
Parameter
RESOLUTION
DC ACCURACY
Differential Nonlinearity
Integral Nonlinearity
No Missing Codes
ANALOG INPUT
Input Voltage Range
Minimum
Maximum
Gain Tempco
Input Bias Current
Input Offset Voltage
Input Full-Scale Matching
Offset Adjustment Range
REFERENCE OUTPUT
Output Voltage
Temperature Coefficient
SWITCHING PERFORMANCE
Maximum Conversion Rate
Minimum Conversion Rate
Data to Clock Skew
tBUFF
tSTAH
tDHO
tDAL
tDAH
tDSU
tSTASU
tSTOTSU
HSYNC Input Frequency
Maximum PLL Clock Rate
Minimum PLL Clock Rate
PLL Jitter
Sampling Phase Tempco
DIGITAL INPUTS
Input Voltage, High (VIH)
Input Voltage, Low (VIL)
Input Current, High (VIH)
Input Current, Low (VIL)
Input Capacitance
Temp
Test
Level
25°C
Full
25°C
Full
Full
I
VI
I
VI
VI
Full
Full
25°C
25°C
Full
Full
Full
Full
VI
VI
V
IV
IV
V
VI
VI
Full
Full
V
V
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
25°C
Full
Full
VI
IV
IV
VI
VI
VI
VI
VI
VI
VI
VI
IV
VI
IV
IV
IV
IV
Full
Full
Full
Full
25°C
VI
VI
V
V
V
Min
Typ
8
Max
AD9985KSTZ-140
Min
±0.5
+1.25/–1.0
+1.35/–1.0
±0.5
±1.85
±2.0
Guaranteed
Typ
8
±0.5
+1.35/−1.0
±1.45/−1.0
±0.5
±2.0
±2.3
Guaranteed
0.5
1.0
Max
0.5
1.0
100
100
1
1
7
1.5
49
46
8.0
52
1
1
46
1.25
±50
7
1.5
49
8.0
52
1.25
±50
110
−0.5
4.7
4.0
300
4.7
4.0
250
4.7
4.0
15
110
110
400
12
7001
10001
110
400
400
15
15
2.5
10
+2.0
−0.5
4.7
4.0
300
4.7
4.0
250
4.7
4.0
15
140
12
7001
7001
2.5
0.8
−1.0
+1.0
3
Rev. 0 | Page 3 of 32
0.8
−1.0
+1.0
3
LSB
LSB
LSB
LSB
V p-p
V p-p
ppm/°C
µA
µA
mV
% FS
% FS
V
ppm/°C
140
10
+2.0
Unit
Bits
MSPS
MSPS
ns
µs
µs
ns
µs
µs
ns
µs
µs
kHz
MHz
MHz
ps p-p
ps p-p
ps/°C
V
V
µA
µA
pF
AD9985
AD9985KSTZ-110
Parameter
DIGITAL OUTPUTS
Output Voltage, High (VOH)
Output Voltage, Low (VOL)
Duty Cycle DATACK
Output Coding
POWER SUPPLY
VD Supply Voltage
VDD Supply Voltage
PVD Supply Voltage
ID Supply Current (VD)
IDD Supply Current (VDD)2
IPVD Supply Current (PVD)
Total Power Dissipation
Power-Down Supply Current
Power-Down Dissipation
DYNAMIC PERFORMANCE
Analog Bandwidth, Full Power
Transient Response
Overvoltage Recovery Time
Signal-to-Noise Ratio (SNR)
(Without Harmonics)
fIN = 40.7 MHz
Crosstalk
THERMAL CHARACTERISTICS
θJC Junction-to-Case
Thermal Resistance
θJA Junction-to-Ambient
Thermal Resistance
1
2
AD9985KSTZ-140
Temp
Test
Level
Full
Full
Full
VI
VI
IV
VD −0.1
45
50
Binary
Full
Full
Full
25°C
25°C
25°C
Full
Full
Full
IV
IV
IV
V
V
V
VI
VI
VI
3.15
2.2
3.15
3.3
3.3
3.3
132
19
8
525
5
16.5
25°C
25°C
25°C
25°C
Full
V
V
V
V
V
300
2
1.5
44
43
300
2
1.5
43
42
MHz
ns
ns
dB
dB
Full
V
55
55
dBc
V
16
16
°C/W
V
35
35
°C/W
Min
Typ
Max
Min
Typ
Max
Unit
0.1
55
V
V
%
VD −0.1
VCO range = 10, charge pump current = 110, PLL divider = 1693.
DATACK load = 15 pF, data load = 5 pF.
Rev. 0 | Page 4 of 32
0.1
55
45
50
Binary
3.45
3.45
3.45
3.15
2.2
3.15
3.3
3.3
3.3
180
26
11
650
5
16.5
760
15
50
3.45
3.45
3.45
900
15
50
V
V
V
mA
mA
mA
mW
mA
mW
AD9985
Table 2.
AD9985BSTZ-110
Parameter
RESOLUTION
DC ACCURACY
Differential Nonlinearity
Integral Nonlinearity
ANALOG INPUT
Input Voltage Range
Minimum
Maximum
Gain Tempco
Input Bias Current
Input Offset Voltage
Input Full-Scale Matching
Offset Adjustment Range
REFERENCE OUTPUT
Output Voltage
Temperature Coefficient
SWITCHING PERFORMANCE
Maximum Conversion Rate
Minimum Conversion Rate
Data to Clock Skew
tBUFF
tSTAH
tDHO
tDAL
tDAH
tDSU
tSTASU
tSTAH
HSYNC Input Frequency
Maximum PLL Clock Rate
Minimum PLL Clock Rate
PLL Jitter
Sampling Phase Tempco
DIGITAL INPUTS
Input Voltage, High (VIH)
Input Voltage, Low (VIL)
Input Current, High (IIH)
Input Current, Low (IIL)
Input Capacitance
DIGITAL OUTPUTS
Output Voltage, High (VOH)
Output Voltage, Low (VOL)
Duty Cycle, DATACK
Output Coding
Temp
Test
Level
25°C
Full
25°C
Full
I
VI
I
VI
Full
Full
25°C
25°C
Full
Full
Full
Full
VI
VI
V
IV
IV
VI
VI
VI
Full
Full
VI
V
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
Full
25°C
Full
Full
VI
IV
IV
VI
VI
VI
VI
VI
VI
VI
VI
IV
VI
IV
IV
IV
IV
Full
Full
Full
Full
25°C
VI
VI
V
V
V
2.5
Full
Full
Full
VI
VI
IV
VD −0.1
Min
Typ
8
Max
±0.5
+1.25/−1.0
+1.5/−1.0
±1.85
±3.2
±0.5
0.5
1.0
100
1
2
46
7
1.5
49
8.0
52
1.25
±100
10
+2.0
15
110
110
400
12
7001
10001
15
0.8
−1.0
1.0
3
45
Rev. 0 | Page 5 of 32
50
Binary
V p-p
V p-p
ppm/°C
µA
µA
mV
% FS
% FS
V
ppm/°C
110
–0.5
4.7
4.0
300
4.7
4.0
250
4.7
Unit
Bits
LSB
LSB
LSB
LSB
0.1
55
MSPS
MSPS
ns
µs
µs
ns
µs
µs
ns
µs
µs
kHz
MHz
MHz
ps p-p
ps p-p
ps/°C
V
V
µA
µA
pF
V
V
%
AD9985
AD9985BSTZ-110
Parameter
POWER SUPPLY
VD Supply Voltage
VDD Supply Voltage
PVD Supply Voltage
ID Supply Current (VD)
IDD Supply Current (VDD) 2
IPVD Supply Current (PVD)
Total Power Dissipation
Power-Down Supply Current
Power-Down Dissipation
DYNAMIC PERFORMANCE
Analog Bandwidth, Full Power
Transient Response
Overvoltage Recovery Time
Signal-to-Noise Ratio (SNR)
(Without Harmonics)
fIN = 40.7 MHz
Crosstalk
THERMAL CHARACTERISTICS
θJC Junction-to-Case
Thermal Resistance
θJA Junction-to-Ambient
Thermal Resistance
1
2
Temp
Test
Level
Full
Full
Full
25°C
25°C
25°C
Full
Full
Full
IV
IV
IV
V
V
V
VI
VI
VI
25°C
25°C
25°C
25°C
Full
V
V
V
V
V
300
2
1.5
44
43
MHz
ns
ns
dB
dB
Full
V
55
dBc
V
16
°C/W
V
35
°C/W
Min
Typ
Max
Unit
3.15
2.2
3.15
3.3
3.3
3.3
132
19
8
525
5
16.5
3.45
3.45
3.45
V
V
V
mA
mA
mA
mW
mA
mW
VCO range = 10, charge pump current = 110, PLL divider = 1693.
DATACK load = 15 pF, data load = 5 pF.
.
EXPLANATION OF TEST LEVELS
Test Level
I.
II.
III.
IV.
V.
100% production tested.
100% production tested at 25°C and sample tested at specified temperatures.
Sample tested only.
Parameter is guaranteed by design and characterization testing.
Parameter is a typical value only.
VI. 100% production tested at 25°C; guaranteed by design and characterization testing.
Rev. 0 | Page 6 of 32
760
15
50
AD9985
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
VD
VDD
Analog Inputs
VREF IN
Digital Inputs
Digital Output Current
Operating Temperature
Storage Temperature
Maximum Junction Temperature
Maximum Case Temperature
Rating
3.6 V
3.6 V
VD to 0.0 V
VD to 0.0 V
5 V to 0.0 V
20 mA
−40°C to +85°C
−65°C to +150°C
150°C
150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions outside of those indicated in the operational
sections of this specification is not implied. Exposure to
absolute maximum ratings for extended periods may affect
device reliability.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. 0 | Page 7 of 32
AD9985
GND
VD
GND
VSOUT
SOGOUT
HSOUT
GND
DATACK
VDD
RED <7>
RED <6>
RED <5>
RED <4>
RED <3>
RED <2>
RED <1>
RED <0>
VDD
VDD
GND
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61
GND
1
GREEN <7>
2
GREEN <6>
60
PIN 1
INDICATOR
GND
59
VD
3
58
REF BYPASS
GREEN <5>
4
57
SDA
GREEN <4>
5
56
SCL
GREEN <3>
6
55
A0
GREEN <2>
7
54
RAIN
GREEN <1>
8
53
GND
GREEN <0>
9
52
AD9985
VD
51
TOP VIEW
(Not to Scale)
VD
50
GND
BLUE <7> 12
49
SOGIN
BLUE <6> 13
48
GAIN
BLUE <5> 14
47
GND
BLUE <4> 15
46
VD
BLUE <3> 16
45
VD
BLUE <2> 17
44
GND
BLUE <1> 18
43
BAIN
BLUE <0> 19
42
VD
GND 20
41
GND
GND 10
VDD 11
04799-0-002
GND
VD
CLAMP
MIDSCV
PVD
GND
PVD
FILT
GND
VSYNC
HSYNC
COAST
GND
PVD
PVD
GND
GND
VDD
VDD
GND
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Figure 2. Pin Configuration
Table 4. Complete Pinout List
Pin Type
Inputs
Outputs
References
Power Supply
Control
Mnemonic
RAIN
GAIN
BAIN
HSYNC
VSYNC
SOGIN
CLAMP
COAST
Red [7:0]
Green [7:0]
Blue [7:0]
DATACK
HSOUT
VSOUT
SOGOUT
REF BYPASS
MIDSCV
Value
0.0 V to 1.0V
0.0 V to 1.0V
0.0 V to 1.0V
3.3 V CMOS
3.3 V CMOS
0.0 V to 1.0 V
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
1.25 V
FILT
VD
VDD
PVD
GND
Function
Analog Input for Converter R
Analog Input for Converter G
Analog Input for Converter B
Horizontal SYNC Input
Vertical SYNC Input
Input for Sync-on-Green
Clamp Input (External CLAMP Signal)
PLL COAST Signal Input
Outputs of Converter Red, Bit 7 is the MSB
Outputs of Converter Green, Bit 7 is the BSB
Outputs of Converter Blue, Bit 7 is the BSB
Data Output Clock
HSYNC Output (Phase-Aligned with DATACK)
VSYNC Output (Phase-Aligned with DATACK)
Sync-on-Green Slicer Output
Internal Reference Bypass
Internal Midscale Voltage Bypass
Connection for External Filter Components
for Internal PLL
Analog Power Supply
Output Power Supply
PLL Power Supply
Ground
SDA
SCL
A0
Serial Port Data I/O
Serial Port Data Clock (100 kHz Maximum
Serial Port Address Input 1
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
Rev. 0 | Page 8 of 32
3.3 V
3.3 V
3.3 V
0V
Pin No.
54
48
43
30
31
49
38
29
70–77
2–9
12–19
67
66
64
65
58
37
33
39, 42, 45, 46, 51, 52, 59, 62
11, 22, 23, 69, 78, 79
26, 27, 34, 35
1, 10, 20, 21, 24, 25, 28, 32, 36, 40, 41,
44, 47, 50, 53, 60, 61, 63, 68, 80
57
56
55
AD9985
Table 5. Pin Function Descriptions
Pin
Name
OUTPUTS
HSOUT
VSOUT
SOGOUT
Function
Horizontal Sync Output
A reconstructed and phase-aligned version of the Hsync input. Both the polarity and duration of this output can be
programmed via serial bus registers. By maintaining alignment with DATACK and Data, data timing with respect to horizontal
sync can always be determined.
Vertical Sync Output
A reconstructed and phase-aligned version of the video Vsync. The polarity of this output can be controlled via a serial bus bit.
The placement and duration in all modes is set by the graphics transmitter.
Sync-On-Green Slicer Output
This pin outputs either the signal from the Sync-on-Green slicer comparator or an unprocessed but delayed version of the
Hsync input. See the Sync Processing Block Diagram (Figure 14) to view how this pin is connected. (Note: Besides slicing off
SOG, the output from this pin gets no other additional processing on the AD9985. Vsync separation is performed via the sync
separator.)
SERIAL PORT (2-Wire)
SDA
Serial Port Data I/O
SCL
Serial Port Data Clock
A0
Serial Port Address Input 1
For a full description of the 2-wire serial register and how it works, refer to the 2-wire serial control port section.
DATA OUTPUTS
RED
Data Output, Red Channel
GREEN
Data Output, Green Channel
BLUE
Data Output, Blue Channel
The main data outputs. Bit 7 is the MSB. The delay from pixel sampling time to output is fixed. When the sampling time is
changed by adjusting the PHASE register, the output timing is shifted as well. The DATACK and HSOUT outputs are also
moved, so the timing relationship among the signals is maintained. For exact timing information, refer to Figure 9, Figure 10,
and Figure 11.
DATA CLOCK OUTPUT
DATACK Data Output Clock
The main clock output signal used to strobe the output data and HSOUT into external logic. It is produced by the internal clock
generator and is synchronous with the internal pixel sampling clock. When the sampling time is changed by adjusting the
PHASE register, the output timing is shifted as well. The Data, DATACK, and HSOUT outputs are all moved, so the timing
relationship among the signals is maintained.
INPUTS
RAIN
Analog Input for Red Channel
GAIN
Analog Input for Green Channel
BAIN
Analog Input for Blue Channel
High impedance inputs that accept the Red, Green, and Blue channel graphics signals, respectively. (The three channels are
identical, and can be used for any colors, but colors are assigned for convenient reference.) They accommodate input signals
ranging from 0.5 V to 1.0 V full scale. Signals should be ac-coupled to these pins to support clamp operation.
HSYNC
Horizontal Sync Input
This input receives a logic signal that establishes the horizontal timing reference and provides the frequency reference for pixel
clock generation. The logic sense of this pin is controlled by serial Register 0EH Bit 6 (Hsync Polarity). Only the leading edge of
Hsync is active; the trailing edge is ignored. When Hsync Polarity = 0, the falling edge of Hsync is used. When Hsync Polarity =
1, the rising edge is active. The input includes a Schmitt trigger for noise immunity, with a nominal input threshold of 1.5 V.
VSYNC
Vertical Sync Input
The input for vertical sync.
Rev. 0 | Page 9 of 32
AD9985
Pin
Name
SOGIN
CLAMP
COAST
REF
BYPASS
Function
Sync-on-Green Input
This input is provided to assist with processing signals with embedded sync, typically on the Green channel. The pin is
connected to a high speed comparator with an internally generated threshold. The threshold level can be programmed in
10 mV steps to any voltage between 10 mV and 330 mV above the negative peak of the input signal. The default voltage
threshold is 150 mV. When connected to an ac-coupled graphics signal with embedded sync, it will produce a noninverting
digital output on SOGOUT. (This is usually a composite sync signal, containing both vertical and horizontal sync information
that must be separated before passing the horizontal sync signal to Hsync.) When not used, this input should be left
unconnected. For more details on this function and how it should be configured, refer to the Sync-on-Green section.
External Clamp Input
This logic input may be used to define the time during which the input signal is clamped to ground. It should be exercised
when the reference dc level is known to be present on the analog input channels, typically during the back porch of the
graphics signal. The CLAMP pin is enabled by setting control bit Clamp Function to 1 (Register 0FH, Bit 7, default is 0). When
disabled, this pin is ignored and the clamp timing is determined internally by counting a delay and duration from the trailing
edge of the Hsync input. The logic sense of this pin is controlled by Clamp Polarity Register 0FH, Bit 6. When not used, this pin
must be grounded and Clamp Function programmed to 0.
Clock Generator Coast Input (Optional)
This input may be used to cause the pixel clock generator to stop synchronizing with Hsync and continue producing a clock at
its current frequency and phase. This is useful when processing signals from sources that fail to produce horizontal sync pulses
during the vertical interval. The COAST signal is generally not required for PC-generated signals. The logic sense of this pin is
controlled by Coast Polarity (Register 0FH, Bit 3). When not used, this pin may be grounded and Coast Polarity programmed to
1, or tied HIGH (to VD through a 10 kΩ resistor) and Coast Polarity programmed to 0. Coast Polarity defaults to 1 at power-up.
Internal Reference BYPASS
Bypass for the internal 1.25 V band gap reference. It should be connected to ground through a 0.1 µF capacitor. The absolute
accuracy of this reference is ±4%, and the temperature coefficient is ±50 ppm, which is adequate for most AD9985 applications. If higher accuracy is required, an external reference may be employed instead.
MIDSCV
Midscale Voltage Reference BYPASS
Bypass for the internal midscale voltage reference. It should be connected to ground through a 0.1 µF capacitor. The exact
voltage varies with the gain setting of the Blue channel.
FILT
External Filter Connection
For proper operation, the pixel clock generator PLL requires an external filter. Connect the filter shown in Figure 8 to this pin.
For optimal performance, minimize noise and parasitics on this node.
POWER SUPPLY
VD
Main Power Supply
These pins supply power to the main elements of the circuit. They should be filtered and as quiet as possible.
VDD
Digital Output Power Supply
A large number of output pins (up to 25) switching at high speed (up to 110 MHz) generates a lot of power supply transients
(noise). These supply pins are identified separately from the VD pins so special care can be taken to minimize output noise
transferred into the sensitive analog circuitry. If the AD9985 is interfacing with lower voltage logic, VDD may be connected to a
lower supply voltage (as low as 2.5 V) for compatibility.
PVD
Clock Generator Power Supply
The most sensitive portion of the AD9985 is the clock generation circuitry. These pins provide power to the clock PLL and help
the user design for optimal performance. The designer should provide quiet, noise-free power to these pins.
GND
Ground
The ground return for all circuitry on-chip. It is recommended that the AD9985 be assembled on a single solid ground plane,
with careful attention given to ground current paths.
Rev. 0 | Page 10 of 32
AD9985
DESIGN GUIDE
GENERAL DESCRIPTION
The AD9985 includes all necessary input buffering, signal dc
restoration (clamping), offset and gain (brightness and contrast)
adjustment, pixel clock generation, sampling phase control, and
output data formatting. All controls are programmable via a
2-wire serial interface. Full integration of these sensitive analog
functions makes system design straightforward and less
sensitive to the physical and electrical environment.
With a typical power dissipation of only 500 mW and an
operating temperature range of 0°C to 70°C, the device requires
no special environmental considerations.
DIGITAL INPUTS
All digital inputs on the AD9985 operate to 3.3 V CMOS levels.
However, all digital inputs are 5 V tolerant. Applying 5 V to
them will not cause any damage.
INPUT SIGNAL HANDLING
The AD9985 has three high impedance analog input pins for
the Red, Green, and Blue channels. They will accommodate
signals ranging from 0.5 V to 1.0 V p-p.
Signals are typically brought onto the interface board via a
DVI-I connector, a 15-pin D connector, or via BNC connectors.
The AD9985 should be located as close as practical to the input
connector. Signals should be routed via matched-impedance
traces (normally 75 Ω) to the IC input pins.
At that point the signal should be resistively terminated (75 Ω
to the signal ground return) and capacitively coupled to the
AD9985 inputs through 47 nF capacitors. These capacitors form
part of the dc restoration circuit.
In an ideal world of perfectly matched impedances, the best
performance can be obtained with the widest possible signal
bandwidth. The ultrawide bandwidth inputs of the AD9985
(300 MHz) can track the input signal continuously as it moves
from one pixel level to the next, and digitize the pixel during a
long, flat pixel time. In many systems, however, there are
mismatches, reflections, and noise, which can result in excessive
ringing and distortion of the input waveform. This makes it
more difficult to establish a sampling phase that provides good
image quality. It has been shown that a small inductor in series
with the input is effective in rolling off the input bandwidth
slightly and providing a high quality signal over a wider range
of conditions. Using a Fair-Rite #2508051217Z0 High Speed
Signal Chip Bead inductor in the circuit of Figure 3 gives good
results in most applications.
47nF
RGB
INPUT
75Ω
RAIN
GAIN
BAIN
04799-0-003
The AD9985 is a fully integrated solution for capturing analog
RGB signals and digitizing them for display on flat-panel
monitors or projectors. The circuit is ideal for providing a
computer interface for HDTV monitors or as the front end to
high performance video scan converters. Implemented in a high
performance CMOS process, the interface can capture signals
with pixel rates up to 110 MHz.
Figure 3. Analog Input Interface Circuit
HSYNC, VSYNC INPUTS
The interface also takes a horizontal sync signal, which is used
to generate the pixel clock and clamp timing. This can be either
a sync signal directly from the graphics source, or a preprocessed TTL or CMOS level signal.
The Hsync input includes a Schmitt trigger buffer for immunity
to noise and signals with long rise times. In typical PC-based
graphic systems, the sync signals are simply TTL-level drivers
feeding unshielded wires in the monitor cable. As such, no
termination is required.
SERIAL CONTROL PORT
The serial control port is designed for 3.3 V logic. If there are
5 V drivers on the bus, these pins should be protected with
150 Ω series resistors placed between the pull-up resistors and
the input pins.
OUTPUT SIGNAL HANDLING
The digital outputs are designed and specified to operate from a
3.3 V power supply (VDD). They can also work with a VDD as low
as 2.5 V for compatibility with other 2.5 V logic.
CLAMPING
RGB Clamping
To properly digitize the incoming signal, the dc offset of the
input must be adjusted to fit the range of the on-board A/D
converters.
Most graphics systems produce RGB signals with black at
ground and white at approximately 0.75 V. However, if sync
signals are embedded in the graphics, the sync tip is often at
ground and black is at 300 mV. Then white is at approximately
1.0 V. Some common RGB line amplifier boxes use emitterfollower buffers to split signals and increase drive capability.
This introduces a 700 mV dc offset to the signal, which must be
removed for proper capture by the AD9985.
The key to clamping is to identify a portion (time) of the signal
when the graphic system is known to be producing black. An
offset is then introduced which results in the A/D converters
producing a black output (code 00h) when the known black
Rev. 0 | Page 11 of 32
AD9985
In systems with embedded sync, a blacker-than-black signal
(Hsync) is produced briefly to signal the CRT that it is time to
begin a retrace. For obvious reasons, it is important to avoid
clamping on the tip of Hsync. Fortunately, there is virtually
always a period following Hsync, called the back porch, where a
good black reference is provided. This is the time when
clamping should be done.
OFFSET = 7FH
OFFSET = 3FH
1.0
The clamp timing can be established by simply exercising the
CLAMP pin at the appropriate time (with External Clamp = 1).
The polarity of this signal is set by the clamp polarity bit.
A simpler method of clamp timing employs the AD9985
internal clamp timing generator. The clamp placement register
is programmed with the number of pixel times that should pass
after the trailing edge of HSYNC before clamping starts. A
second register (clamp duration) sets the duration of the clamp.
These are both 8-bit values, providing considerable flexibility in
clamp generation. The clamp timing is referenced to the trailing
edge of Hsync because, though Hsync duration can vary widely,
the back porch (black reference) always follows Hsync. A good
starting point for establishing clamping is to set the clamp
placement to 09H (providing 9 pixel periods for the graphics
signal to stabilize after sync) and set the clamp duration to 14H
(giving the clamp 20 pixel periods to reestablish the black
reference).
OFFSET = 00H
0.5
OFFSET = 7FH
OFFSET = 3FH
0
OFFSET = 00H
00H
FFH
GAIN
04799-0-004
In most PC graphics systems, black is transmitted between
active video lines. With CRT displays, when the electron beam
has completed writing a horizontal line on the screen (at the
right side), the beam is deflected quickly to the left side of the
screen (called horizontal retrace), and a black signal is provided
to prevent the beam from disturbing the image.
Clamping to midscale rather than to ground can be accomplished by setting the clamp select bits in the serial bus register.
Each of the three converters has its own selection bit so that
they can be clamped to either midscale or ground independently. These bits are located in Register 10H and are
Bits 0–2. The midscale reference voltage that each A/D
converter clamps to is provided on the MIDSCV pin (Pin 37).
This pin should be bypassed to ground with a 0.1 µF capacitor,
even if midscale clamping is not required.
INPUT RANGE (V)
input is present. The offset then remains in place when other
signal levels are processed, and the entire signal is shifted to
eliminate offset errors.
Figure 4. Gain and Offset Control
GAIN AND OFFSET CONTROL
The AD9985 can accommodate input signals with inputs
ranging from 0.5 V to 1.0 V full scale. The full-scale range is set
in three 8-bit registers (Red Gain, Green Gain, and Blue Gain).
Note that increasing the gain setting results in an image with less
contrast.
The offset control shifts the entire input range, resulting in a
change in image brightness. Three 7-bit registers (Red Offset,
Green Offset, Blue Offset) provide independent settings for
each channel. The offset controls provide a ±63 LSB adjustment
range. This range is connected with the full-scale range, so if the
input range is doubled (from 0.5 V to 1.0 V) then the offset step
size is also doubled (from 2 mV per step to 4 mV per step).
Clamping is accomplished by placing an appropriate charge on
the external input coupling capacitor. The value of this capacitor
affects the performance of the clamp. If it is too small, there will
be a significant amplitude change during a horizontal line time
(between clamping intervals). If the capacitor is too large, then
it will take excessively long for the clamp to recover from a large
change in incoming signal offset. The recommended value
(47 nF) results in recovering from a step error of 100 mV to
within 1/2 LSB in 10 lines with a clamp duration of 20 pixel
periods on a 60 Hz SXGA signal.
Figure 4 illustrates the interaction of gain and offset controls.
The magnitude of an LSB in offset adjustment is proportional to
the full-scale range, so changing the full-scale range also
changes the offset. The change is minimal if the offset setting is
near midscale. When changing the offset, the full-scale range is
not affected, but the full-scale level is shifted by the same
amount as the zero-scale level.
YUV Clamping
Auto Offset
YUV graphic signals are slightly different from RGB signals in
that the dc reference level (black level in RGB signals) can be at
the midpoint of the graphics signal rather than at the bottom.
For these signals, it can be necessary to clamp to the midscale
range of the A/D converter range (80H) rather than at the
bottom of the A/D converter range (00H).
In addition to the manual offset adjustment mode (via
Registers 0Bh to 0Dh), the AD9985 also includes circuitry to
automatically calibrate the offset for each channel. By
monitoring the output of each ADC during the back porch of
the input signals, the AD9985 can self-adjust to eliminate any
Rev. 0 | Page 12 of 32
AD9985
47nF
offset errors in its own ADC channels as well as any offset
errors present on the incoming graphics or video signals.
RAIN
47nF
BAIN
The ability to program a target code for each channel gives
users a large degree of freedom and flexibility. While in most
cases all channels will be set to either 1 or 128, the flexibility to
select other values allows for the possibility of inserting
intentional skews between channels. It also allows for the ADC
range to be skewed so that voltages outside of the normal range
can be digitized. (For example, setting the target code to 40
would allow the sync tip, which is normally below black level, to
be digitized and evaluated.)
Lastly, when in auto offset mode, the manual offset registers
(0Bh to 0Dh) have new functionality. The values in these
registers are digitally added to the value of the ADC output. The
purpose of doing this is to match a benefit that is present with
manual offset adjustment. Adjusting these registers is an easy
way to make brightness adjustments. Although some signal
range is lost with this method, it has proven to be a very popular
function. In order to be able to increase and decrease brightness,
the values in these registers in this mode are signed twos
complement. The digital adder is used only when in auto offset
mode. Although it cannot be disabled, setting the offset registers
to all 0’s will effectively disable it by always adding 0.
47nF
GAIN
1nF
SOG
04799-0-005
To activate the auto-offset mode, set Register 1Dh, Bit 7 to 1.
Next, the target code registers (19h through 1Bh) must be
programmed. The values programmed into the target code
registers should be the output code desired from the AD9985
during the back porch reference time. For example, for RGB
signals, all three registers would normally be programmed to
code 1, while for YPbPr signals the green (Y) channel would
normally be programmed to code 1 and the blue and red
channels (Pb and Pr) would normally be set to 128. Any target
code value between 1 and 254 can be set, although the AD9985’s
offset range may not be able to reach every value. Intended
target code values range from (but are not limited to) 1 to 40
when ground clamping and 90 to 170 when midscale clamping.
Figure 5. Typical Clamp Configuration
CLOCK GENERATION
A phase-locked loop (PLL) is employed to generate the pixel
clock. In this PLL, the Hsync input provides a reference
frequency. A voltage controlled oscillator (VCO) generates a
much higher pixel clock frequency. This pixel clock is divided
by the PLL divide value (Registers 01H and 02H) and phase
compared with the Hsync input. Any error is used to shift the
VCO frequency and maintain lock between the two signals.
The stability of this clock is a very important element in
providing the clearest and most stable image. During each pixel
time, there is a period during which the signal is slewing from
the old pixel amplitude and settling at its new value. Then there
is a time when the input voltage is stable, before the signal must
slew to a new value (Figure 6). The ratio of the slewing time to
the stable time is a function of the bandwidth of the graphics
DAC and the bandwidth of the transmission system (cable and
termination). It is also a function of the overall pixel rate.
Clearly, if the dynamic characteristics of the system remain
fixed, the slewing and settling time is likewise fixed. This time
must be subtracted from the total pixel period, leaving the stable
period. At higher pixel frequencies, the total cycle time is
shorter, and the stable pixel time becomes shorter as well.
PIXEL CLOCK
INVALID SAMPLE TIMES
The Sync-on-Green input operates in two steps. First, it sets a
baseline clamp level off of the incoming video signal with a
negative peak detector. Second, it sets the sync trigger level to a
programmable level (typically 150 mV) above the negative peak.
The Sync-on-Green input must be ac-coupled to the Green
analog input through its own capacitor, as shown in Figure 5.
The value of the capacitor must be 1 nF ±20%. If Sync-onGreen is not used, this connection is not required. Note that the
Sync-on-Green signal is always negative polarity.
04799-0-006
SYNC-ON-GREEN
Figure 6. Pixel Sampling Times
Any jitter in the clock reduces the precision with which the
sampling time can be determined, and must also be subtracted
from the stable pixel time.
Considerable care has been taken in the design of the AD9985’s
clock generation circuit to minimize jitter. As indicated in
Figure 7, the clock jitter of the AD9985 is less than 5% of the
total pixel time in all operating modes, making the reduction in
the valid sampling time due to jitter negligible.
Rev. 0 | Page 13 of 32
AD9985
3.
14
PIXEL CLOCK JITTER (p-p) (%)
12
Table 7. Charge Pump Current/Control Bits
10
Ip2
0
0
0
0
1
1
1
1
8
6
4
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
FREQUENCY (MHz)
04799-0-007
2
0
4.
Figure 7. Pixel Clock Jitter vs. Frequency
The PLL characteristics are determined by the loop filter design,
by the PLL charge pump current, and by the VCO range setting.
The loop filter design is illustrated in Figure 8. Recommended
settings of VCO range and charge pump current for VESA
standard display modes are listed in Table 9.
RZ
2.7kΩ
FILT
Figure 8. PLL Loop Filter Detail
Four programmable registers are provided to optimize the
performance of the PLL:
2.
The 12-Bit Divisor Register. The input Hsync frequencies
range from 15 kHz to 110 kHz. The PLL multiplies the
frequency of the Hsync signal, producing pixel clock
frequencies in the range of 12 MHz to 110 MHz. The
Divisor register controls the exact multiplication factor.
This register may be set to any value between 221 and 4095.
(The divide ratio that is actually used is the programmed
divide ratio plus one.)
The 2-Bit VCO Range Register. To improve the noise
performance of the AD9985, the VCO operating frequency
range is divided into three overlapping regions. The VCO
range register sets this operating range. Table 6 lists the
frequency ranges for the lowest and highest regions.
Table 6. VCO Frequency Ranges
PV1
0
0
1
1
PV0
0
1
0
1
Pixel Clock Range (MHz)
AD9985KSTZ
AD9985BSTZ
12–32
12–30
32–64
30–60
64–110
60–110
110–140
Ip1
0
0
1
1
0
0
1
1
Ip0
0
1
0
1
0
1
0
1
Current (µA)
50
100
150
250
350
500
750
1500
The 5-Bit Phase Adjust Register. The phase of the generated sampling clock may be shifted to locate an optimum
sampling point within a clock cycle. The phase adjust
register provides 32 phase-shift steps of 11.25° each. The
Hsync signal with an identical phase shift is available
through the HSOUT pin.
The COAST pin is used to allow the PLL to continue to
run at the same frequency, in the absence of the incoming
Hsync signal or during disturbances in Hsync (such as
equalization pulses). This may be used during the vertical
sync period, or any other time that the Hsync signal is
unavailable. The polarity of the COAST signal may be set
through the coast polarity register. Also, the polarity of the
Hsync signal may be set through the Hsync polarity
register. If not using automatic polarity detection, the
Hsync and COAST polarity bits should be set to match the
respective polarities of the input signals.
PVD
04799-0-008
CZ
0.082µF
CP
0.0082µF
1.
The 3-Bit Charge Pump Current Register. This register
allows the current that drives the low-pass loop filter to be
varied. The possible current values are listed in Table 7.
POWER MANAGEMENT
The AD9985 uses the activity detect circuits, the active interface
bits in the serial bus, the active interface override bits, and the
power-down bit to determine the correct power state. There are
three power states—full-power, seek mode, and power-down.
Table 8 summarizes how the AD9985 determines what power
mode to be in and which circuitry is powered on/off in each of
these modes. The power-down command has priority over the
automatic circuitry.
Table 8. Power-Down Mode Descriptions
Inputs
Power-Down1
Sync
Detect2
Powered On or
Comments
1
1
Everything
Seek
Mode
1
0
PowerDown
0
X
Mode
FullPower
1
Serial Bus, Sync
Activity Detect, SOG,
Band Gap Reference
Serial Bus, Sync
Activity Detect, SOG,
Band Gap Reference
Power-down is controlled via Bit 1 in serial bus Register 0FH.
Sync detect is determined by OR’ing Bits 7, 4, and 1 in serial bus
Register 14H.
2
Rev. 0 | Page 14 of 32
AD9985
Table 9. Recommended VCO Range and Charge Pump Current Settings for Standard Display Formats
AD9985KSTZ
Standard
Modes
VGA
Resolution
640 × 480
SVGA
800 × 600
XGA
1024 × 768
SXGA
1280 × 1024
TV Modes
480i
480p
720p
1080i
720 × 480
720 × 483
1280 × 720
1920 × 1080
Refresh
Rate (Hz)
60
72
75
85
56
60
72
75
85
60
70
75
80
85
60
75
Horizontal
Frequency (kHz)
31.5
37.7
37.5
43.3
35.1
37.9
48.1
46.9
53.7
48.4
56.5
60.0
64.0
68.3
64.0
80.0
Pixel Rate
(MHz)
25.175
31.500
31.500
36.000
36.000
40.000
50.000
49.500
56.250
65.000
75.000
78.750
85.500
94.500
108.000
135.000
60
60
60
60
15.75
31.47
45.0
33.75
13.51
27.00
74.25
74.25
PLL
Div
799
835
841
831
1025
1055
1039
1055
1047
1343
1327
1313
1335
1383
1687
1687
VCORNGE
00
00
00
01
01
01
01
01
01
10
10
10
10
10
10
11
857
857
1649
2199
00
00
10
10
Current
110
110
110
100
100
100
101
101
101
101
100
100
101
101
110
110
011
110
100
100
AD9985BSTZ
VCORNGE
00
01
01
01
01
01
01
01
01
10
10
10
10
10
10
Current
011
010
010
010
010
011
100
100
101
011
011
011
100
100
101
00
00
10
10
011
011
011
011
TIMING
The following timing diagrams show the operation of the
AD9985.
The output data clock signal is created so that its rising edge
always occurs between data transitions and can be used to latch
the output data externally.
There is a pipeline in the AD9985, which must be flushed before
valid data becomes available. This means that four data sets are
presented before valid data is available.
tPER
tCYCLE
DATACK
04799-0-009
tSKEW
DATA
HSOUT
Figure 9. Output Timing
HSYNC TIMING
Horizontal Sync (Hsync) is processed in the AD9985 to
eliminate ambiguity in the timing of the leading edge with
respect to the phase-delayed pixel clock and data.
The Hsync input is used as a reference to generate the pixel
sampling clock. The sampling phase can be adjusted, with
respect to Hsync, through a full 360° in 32 steps via the phase
adjust register (to optimize the pixel sampling time). Display
systems use Hsync to align memory and display write cycles, so
it is important to have a stable timing relationship between
Hsync output (HSOUT) and data clock (DATACK).
Three things happen to Horizontal Sync in the AD9985. First,
the polarity of Hsync input is determined and will thus have a
known output polarity. The known output polarity can be
programmed either active high or active low (Register 0EH,
Bit 5). Second, HSOUT is aligned with DATACK and data
outputs. Third, the duration of HSOUT (in pixel clocks) is set
via Register 07H. HSOUT is the sync signal that should be used
to drive the rest of the display system.
COAST TIMING
In most computer systems, the Hsync signal is provided
continuously on a dedicated wire. In these systems, the COAST
input and function are unnecessary and should not be used, and
the pin should be permanently connected to the inactive state.
In some systems, however, Hsync is disturbed during the
Vertical Sync period (Vsync). In some cases, Hsync pulses
Rev. 0 | Page 15 of 32
AD9985
disappear. In other systems, such as those that employ
Composite Sync (Csync) signals or embedded Sync-on-Green
(SOG), Hsync includes equalization pulses or other distortions
during Vsync. To avoid upsetting the clock generator during
Vsync, it is important to ignore these distortions. If the pixel
clock PLL sees extraneous pulses, it will attempt to lock to this
new frequency, and will have changed frequency by the end of
RGBIN
P0
P1
P2
P3
P4
P5
P6
the Vsync period. It will then take a few lines of correct Hsync
timing to recover at the beginning of a new frame, resulting in a
“tearing” of the image at the top of the display.
The COAST input is provided to eliminate this problem. It is an
asynchronous input that disables the PLL input and allows the
clock to free-run at its then-current frequency. The PLL can
free-run for several lines without significant frequency drift.
P7
HSYNC
PxCK
HS
5-PIPE DELAY
ADCCK
DATACK
D0
D1
D2
HSOUT
D3
D4
D5
D6
D7
04799-0-010
DOUTA
VARIABLE DURATION
.
Figure 10. 4:4:4 Mode (For RGB and YUV)
RGBIN
P0
P1
P2
P3
P4
P5
P6
P7
HSYNC
PxCK
HS
5-PIPE DELAY
ADCCK
GOUTA
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
ROUTA
U0
V1
U2
V3
U4
V5
U6
V7
HSOUT
VARIABLE DURATION
04799-0-011
DATACK
Figure 11. 4:2:2 Mode (For YUV Only)
2-WIRE SERIAL REGISTER MAP
The AD9985 is initialized and controlled by a set of registers, that determine the operating modes. An external controller is employed to
write and read the control registers through the two-line serial interface port.
Table 10. Control Register Map
Hex
Address
00H
01H*
Write and
Read or
Read Only
RO
R/W
Bits
7:0
7:0
01101001
Register Name
Chip Revision
PLL Div MSB
02H*
R/W
7:4
1101****
PLL Div LSB
Default
Value
Function
An 8-bit register that represents the silicon revision level.
This register is for Bits [11:4] of the PLL divider. Greater values mean
the PLL operates at a faster rate. This register should be loaded first
whenever a change is needed. This will give the PLL more time to lock.
Bits [7:4] of this word are written to the LSBs [3:0] of the PLL divider
word.
Rev. 0 | Page 16 of 32
AD9985
Hex
Address
03H
Write and
Read or
Read Only
R/W
Bits
7:3
Default
Value
01******
Register Name
**001***
Function
Bits [7:6] VCO Range. Selects VCO frequency range. (See PLL
description.)
Bits [5:3] Charge Pump Current. Varies the current that drives the
low-pass filter. (See PLL description.)
ADC Clock Phase Adjustment. Larger values mean more delay.
(1 LSB = T/32)
Places the clamp signal an integer number of clock periods after the
trailing edge of the Hsync signal.
Number of clock periods that the clamp signal is actively clamping.
04H
R/W
7:3
10000***
Phase Adjust
05H
R/W
7:0
10000000
06H
R/W
7:0
10000000
Clamp
Placement
Clamp Duration
07H
R/W
7:0
00100000
Hsync Output
Pulsewidth
Sets the number of pixel clocks that HSOUT will remain active.
08H
09H
0AH
0BH
0CH
0DH
0EH
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7:0
7:0
7:0
7:1
7:1
7:1
7:0
10000000
10000000
10000000
1000000*
1000000*
1000000*
0*******
Red Gain
Green Gain
Blue Gain
Red Offset
Green Offset
Blue Offset
Sync Control
Controls ADC input range (contrast) of each respective channel.
Greater values give less contrast.
*1******
**0*****
***0****
****0***
*****0**
******0*
*******0
0FH
R/W
7:1
0*******
*1******
**0*****
***0****
****1***
*****1**
******1*
10H
R/W
7:3
10111***
Sync-on-Green
Threshold
Controls dc offset (brightness) of each respective channel. Greater
values decrease brightness.
Bit 7 – Hsync Polarity Override. (Logic 0 = Polarity determined by chip,
Logic 1 = Polarity set by Bit 6 in Register 0EH.)
Bit 6 – Hsync Input Polarity. Indicates polarity of incoming Hsync signal
to the PLL. (Logic 0 = Active Low, Logic 1 = Active High.)
Bit 5 – Hsync Output Polarity. (Logic 0 = Logic High Sync, Logic 1 =
Logic Low Sync.)
Bit 4 – Active Hsync Override. If set to Logic 1, the user can select the
Hsync to be used via Bit 3. If set to Logic 0, the active interface is
selected via Bit 6 in Register 14H.
Bit 3 – Active Hsync Select. Logic 0 selects Hsync as the active sync.
Logic 1 selects Sync-on-Green as the active sync. Note that the
indicated Hsync will be used only if Bit 4 is set to Logic 1 or if both
syncs are active. (Bits 1, 7 = Logic 1 in Register 14H.)
Bit 2 – Vsync Output Invert. (Logic 1 = No Invert, Logic 0 = Invert.)
Bit 1 – Active Vsync Override. If set to Logic 1, the user can select the
Vsync to be used via Bit 0. If set to Logic 0, the active interface is
selected via Bit 3 in Register 14H.
Bit 0 – Active Vsync Select. Logic 0 selects raw Vsync as the output
Vsync. Logic 1 selects sync separated Vsync as the output Vsync. Note
that the indicated Vsync will be used only if Bit 1 is set to Logic 1.
Bit 7 – Clamp Function. Chooses between Hsync for Clamp signal or
another external signal to be used for clamping. (Logic 0 = Hsync,
Logic 1 = Clamp.)
Bit 6 – Clamp Polarity. Valid only with external Clamp signal. (Logic 0 =
Active High, Logic 1 Selects Active Low.)
Bit 5 – Coast Select. Logic 0 selects the coast input pins to be used for
the PLL coast. Logic 1 selects Vsync to be used for the PLL coast.
Bit 4 – Coast Polarity Override. (Logic 0 = Polarity determined by chip,
Logic 1 = Polarity set by Bit 3 in Register 0FH.)
Bit 3 – Coast Polarity. Selects polarity of external Coast signal. (Logic 0
= Active Low, Logic 1 = Active High.)
Bit 2 – Seek Mode Override. (Logic 1 = Allow Low Power Mode, Logic 0
= Disallow Low Power Mode.)
Bit 1 – PWRDN. Full Chip Power-Down, Active Low. (Logic 0 = Full Chip
Power-Down, Logic 1 = Normal.)
Sync-on-Green Threshold. Sets the voltage level of the Sync-on-Green
slicer’s comparator.
Rev. 0 | Page 17 of 32
AD9985
Hex
Address
Write and
Read or
Read Only
Bits
Default
Value
*****0**
Register Name
11H
R/W
7:0
00100000
Sync Separator
Threshold
12H
R/W
7:0
00000000
Pre-Coast
13H
R/W
7:0
00000000
Post-Coast
14H
RO
7:0
15H
R/W
7:2
111111**
Reserved
1
******1*
Output Formats
*******1
Reserved
Test Register
Function
Bit 2 – Red Clamp Select. Logic 0 selects clamp to ground. Logic 1
selects clamp to midscale (voltage at Pin 37).
Bit 1 – Green Clamp Select. Logic 0 selects clamp to ground. Logic 1
selects clamp to midscale (voltage at Pin 37).
Bit 0 – Blue Clamp Select. Logic 0 selects clamp to ground. Logic 1
selects clamp to midscale (voltage at Pin 37).
Sync Separator Threshold. Sets how many internal 5 MHz clock periods
the sync separator will count to before toggling high or low. This
should be set to some number greater than the maximum Hsync or
equalization pulsewidth.
Pre-Coast. Sets the number of Hsync periods that Coast becomes
active prior to Vsync.
Post-Coast. Sets the number of Hsync periods that Coast stays active
following Vsync.
Bit 7 – Hsync detect. It is set to Logic 1 if Hsync is present on the
analog interface; otherwise it is set to Logic 0.
Bit 6 – AHS: Active Hsync. This bit indicates which analog Hsync is
being used. (Logic 0 = Hsync Input Pin, Logic 1 = Hsync from Sync-onGreen.)
Bit 5 – Input Hsync Polarity Detect. (Logic 0 = Active Low, Logic 1 =
Active High.)
Bit 4 – Vsync Detect. It is set to Logic 1 if Vsync is present on the analog
interface; otherwise it is set to Logic 0.
Bit 3 – AVS: Active Vsync. This bit indicates which analog Vsync is
being used. (Logic 0 = Vsync Input Pin, Logic 1 = Vsync from Sync
Separator.)
Bit 2 – Output Vsync Polarity Detect. (Logic 0 = Active Low, Logic 1 =
Active High.)
Bit 1 – Sync-on-Green Detect. It is set to Logic 1 if sync is present on
the Green video input; otherwise it is set to 0.
Bit 0 – Input Coast Polarity Detect. (Logic 0 = Active Low, Logic 1 =
Active High.)
Bits [7:2] Reserved for future use. Must be written to 111111 for proper
operation.
Bit 1 – 4:2:2 Output Formatting Mode (Logic 0 = 4:2:2 mode, Logic 1=
4:4:4 mode)
Bit 0 – Must be set to 0 for proper operation.
Reserved for future use.
Test Register
Test Register
Red Target Code
Reserved for future use.
Reserved for future use.
Target Code for Auto Offset Operation.
Green Target
Code
Blue Target
Code
Reserved
Target Code for Auto Offset Operation.
******0*
*******0
Sync Detect
16H
R/W
0
7:0
17H
18H
19H
RO
RO
R/W
7:0
7:0
7:0
00000100
1AH
R/W
7:0
00000100
1BH
R/W
7:0
00000100
1CH
R/W
7:0
00010001
1DH
R/W
7
0*******
R/W
6
5:2
1:0
7:0
*0******
**1001**
******10
0000****
1EH
Auto Offset
Enable
Hold Auto Offset
Reserved
Update Mode
Test Register
Target Code for Auto Offset Operation.
Must be written to 11h for proper operation.
Enables the auto offset circuitry.
Holds the offset output of the auto offset at the current value.
Must be written to 9 for proper operation.
Changes the update rate of the auto offset.
Must be set to default value.
*The AD9985 updates the PLL divide ratio only when the LSBs are written to (Register 02H).
Rev. 0 | Page 18 of 32
AD9985
2-WIRE SERIAL CONTROL REGISTER DETAIL CHIP
IDENTIFICATION
00
CLOCK GENERATOR CONTROL
03
7–0 Chip Revision
An 8-bit register that represents the silicon revision.
PLL DIVIDER CONTROL
01
VCORNGE must be set to correspond with the
desired operating frequency (incoming pixel rate).
7–0
PLL Divide Ratio MSBs
The 8 most significant bits of the 12-bit PLL divide
ratio PLLDIV. The operational divide ratio is
PLLDIV + 1.
The PLL gives the best jitter performance at high
frequencies. For this reason, to output low pixel rates
and still get good jitter performance, the PLL actually
operates at a higher frequency but then divides down
the clock rate afterwards.
The PLL derives a master clock from an incoming
Hsync signal. The master clock frequency is then
divided by an integer value, such that the output is
phase-locked to Hsync. This PLLDIV value
determines the number of pixel times (pixels plus
horizontal blanking overhead) per line. This is
typically 20% to 30% more than the number of active
pixels in the display.
Table 11 shows the pixel rates for each VCO range setting. The
PLL output divisor is automatically selected with the
VCO range setting.
The 12-bit value of the PLL divider supports divide
ratios from 2 to 4095. The higher the value loaded in
this register, the higher the resulting clock frequency
with respect to a fixed Hsync frequency.
PV1
0
0
1
1
VESA has established some standard timing
specifications that assist in determining the value for
PLLDIV as a function of horizontal and vertical
display resolution and frame rate (Table 9).
However, many computer systems do not conform
precisely to the recommendations, and these numbers
should be used only as a guide. The display system
manufacturer should provide automatic or manual
means for optimizing PLLDIV. An incorrectly set
PLLDIV will usually produce one or more vertical
noise bars on the display. The greater the error, the
greater the number of bars produced.
The power-up default value of PLLDIV is 1693
(PLLDIVM = 69H, PLLDIVL = DxH).
The AD9985 updates the full divide ratio only when
the LSBs are changed. Writing to the MSB by itself will
not trigger an update.
02
7–6 VCO Range Select
Two bits that establish the operating range of the clock
generator.
Table 11. VCO Ranges
PV0
0
1
0
1
Pixel Clock Range (MHz)
AD9985KSTZ
AD9985BSTZ
12–32
12–30
32–64
30–60
64–110
60–110
110–140
The power-up default value is 01.
03
5–3 CURRENT Charge Pump Current
Three bits that establish the current driving the loop
filter in the clock generator.
Table 12. Charge Pump Currents
CURRENT
Current (µA)
000
001
010
011
100
101
110
111
50
100
150
250
350
500
750
1500
CURRENT must be set to correspond with the desired
operating frequency (incoming pixel rate).
The power-up default value is current = 001.
7–4 PLL Divide Ratio LSBs
The 4 least significant bits of the 12-bit PLL divide
ratio PLLDIV. The operational divide ratio is
PLLDIV + 1.
04
The power-up default value of PLLDIV is 1693
(PLLDIVM = 69H, PLLDIVL = DxH). The AD9985
updates the full divide ratio only when this register is
written to.
Rev. 0 | Page 19 of 32
7–3 Clock Phase Adjust
A 5-bit value that adjusts the sampling phase in 32
steps across one pixel time. Each step represents an
11.25° shift in sampling phase.
The power-up default value is 16.
AD9985
CLAMP TIMING
05
7–0 Clamp Placement
An 8-bit register that sets the position of the internally
generated clamp.
When Clamp Function (Register 0FH, Bit 7) = 0, a
clamp signal is generated internally, at a position
established by the clamp placement and for a duration
set by the clamp duration. Clamping is started (Clamp
Placement) pixel periods after the trailing edge of
Hsync. The clamp placement may be programmed to
any value between 1 and 255.
09
7–0 Green Channel Gain Adjust
An 8-bit word that sets the gain of the Green channel.
See REDGAIN (08).
0A
7–0 Blue Channel Gain Adjust
An 8-bit word that sets the gain of the Blue channel.
See REDGAIN (08).
INPUT OFFSET
0B
The clamp should be placed during a time that the
input signal presents a stable black-level reference,
usually the back porch period between Hsync and the
image.
When in manual offset adjustment mode (auto offset
turned off) this register behaves exactly like the
AD9883A. It is a 7-bit offset binary word that sets the
dc offset of the Red channel. One LSB of offset
adjustment equals approximately one LSB change in
the ADC offset. Therefore, the absolute magnitude of
the offset adjustment scales as the gain of the channel
is changed. A nominal setting of 63 results in the
channel nominally clamping the back porch (during
the clamping interval) to Code 00. An offset setting of
127 results in the channel clamping to Code 64 of the
ADC. An offset setting of 0 clamps to Code –63 (off
the bottom of the range). Increasing the value of Red
Offset decreases the brightness of the channel.
When Clamp Function = 1, this register is ignored.
06
7–0 Clamp Duration
An 8-bit register that sets the duration of the
internally generated clamp.
For the best results, the clamp duration should be set
to include the majority of the black reference signal
time that follows the Hsync signal trailing edge.
Insufficient clamping time can produce brightness
changes at the top of the screen, and a slow recovery
from large changes in the average picture level (APL),
or brightness.
When in auto offset mode, the value in this register is
digitally added to the red channel ADC output. The
purpose of doing this is to match a benefit that is
present with manual offset adjustment. Adjusting
these registers is an easy way to make brightness
adjustments. Although some signal range is lost with
this method, it has proven to be a very popular
function. In order to be able to increase and decrease
brightness, the values in these registers in this mode
are signed twos complement (as opposed to manual
mode where the values in this register are binary). The
digital adder is used only when in auto offset mode.
Although it cannot be disabled, setting this register to
all 0’s will effectively disable it by always adding 0.
When Clamp Function = 1, this register is ignored.
HSYNC PULSEWIDTH
07
7–0 Hsync Output Pulsewidth
An 8-bit register that sets the duration of the Hsync
output pulse.
The leading edge of the Hsync output is triggered by
the internally generated, phase-adjusted PLL feedback
clock. The AD9985 then counts a number of pixel
clocks equal to the value in this register. This triggers
the trailing edge of the Hsync output, which is also
phase adjusted.
INPUT GAIN
08
7–0 Red Channel Gain Adjust
An 8-bit word that sets the gain of the Red channel.
The AD9985 can accommodate input signals with a
full-scale range of between 0.5 V and 1.0 V p-p.
Setting REDGAIN to 255 corresponds to a 1.0 V input
range. A REDGAIN of 0 establishes a 0.5 V input
range. Note that increasing REDGAIN results in the
picture having less contrast (the input signal uses
fewer of the available converter codes). See Figure 4.
7–1 Red Channel Offset Adjust
This and the following two offset registers have two
modes of operation. One mode is when the auto offset
function is turned off (manual mode) and the other is
when auto offset is turned on.
0C
7–1 Green Channel Offset Adjust
This register works exactly like the Red Channel
Offset Adjust register (0Bh), except it is for the Green
Channel.
0D
7–1 Blue Channel Offset Adjust
This register works exactly like the Red Channel
Offset Adjust register (0Bh), except it is for the Blue
Channel.
Rev. 0 | Page 20 of 32
AD9985
MODE CONTROL 1
Table 16. Active Hsync Override Settings
0E
Override
0
1
7
Hsync Input Polarity Override
This register is used to override the internal circuitry
that determines the polarity of the Hsync signal going
into the PLL.
Table 13. Hsync Input Polarity Override Settings
Override Bit
0
1
The default for this register is 0.
0E
Function
Hsync Polarity Determined by Chip
Hsync Polarity Determined by User
The default for Hsync polarity override is 0 (polarity
determined by chip).
0E
6
HSPOL Hsync Input Polarity
A bit that must be set to indicate the polarity of the
Hsync signal that is applied to the PLL Hsync input.
Table 14. Hsync Input Polarity Settings
HSPOL
0
1
3
Active Hsync Select
This bit is used under two conditions. It is used to
select the active Hsync when the override bit is set
(Bit 4). Alternately, it is used to determine the active
Hsync when not overriding but both Hsyncs are
detected.
Table 17. Active HSYNC Select Settings
Select
0
1
Result
HSYNC Input
Sync-on-Green Input
The default for this register is 0.
Function
Active Low
Active High
0E
Active Low means the leading edge of the Hsync pulse
is negative going. All timing is based on the leading
edge of Hsync, which is the falling edge. The rising
edge has no effect.
Active high is inverted from the traditional Hsync,
with a positive-going pulse. This means that timing
will be based on the leading edge of Hsync, which is
now the rising edge.
The device will operate if this bit is set incorrectly, but
the internally generated clamp position, as established
by Clamp Placement (Register 05H), will not be
placed as expected, which may generate clamping
errors.
The power-up default value is HSPOL = 1.
0E
Result
Autodetermines the Active Interface
Override, Bit 3 Determines the Active Interface
5 Hsync Output Polarity
This bit determines the polarity of the Hsync output
and the SOG output. Table 15 shows the effect of this
option. SYNC indicates the logic state of the sync
pulse.
2
Vsync Output Invert
This bit inverts the polarity of the Vsync output.
Table 18 shows the effect of this option.
Table 18. Vsync Output Invert Settings
Setting
0
1
Vsync Output
Invert
No Invert
The default setting for this register is 0.
0E
1
Active Vsync Override
This bit is used to override the automatic Vsync
selection. To override, set this bit to Logic 1. When
overriding, the active interface is set via Bit 0 in this
register.
Table 19. Active Vsync Override Settings
Override
0
1
Result
Autodetermines the Active Vsync
Override, Bit 0 Determines the Active Vsync
The default for this register is 0.
0E
0
Active Vsync Select
This bit is used to select the active Vsync when the
override bit is set (Bit 1).
Table 15. Hsync Output Polarity Settings
Table 20. Active Vsync Select Settings
Setting
0
1
Select
0
1
SYNC
Logic 1 (Positive Polarity)
Logic 0 (Negative Polarity)
The default setting for this register is 0.
0E
Result
Vsync Input
Sync Separator Output
The default for this register is 0.
4
Active Hsync Override
This bit is used to override the automatic Hsync
selection, To override, set this bit to Logic 1. When
overriding, the active Hsync is set via Bit 3 in this
register.
Rev. 0 | Page 21 of 32
AD9985
0F
The default for coast polarity override is 0.
7
Clamp Input Signal Source
This bit determines the source of clamp timing.
0F
Table 21. Clamp Input Signal Source Settings
Clamp Function
0
1
Function
Internally Generated Clamp Signal
Externally Provided Clamp Signal
Table 25. Coast Input Polarity Settings
A 0 enables the clamp timing circuitry controlled by
clamp placement and clamp duration. The clamp
position and duration is counted from the leading
edge of Hsync.
Coast Polarity
0
1
Active High means that the clock generator will ignore
Hsync inputs when Coast is high, and continue
operating at the same nominal frequency until Coast
goes low.
The power-up default value is Clamp Function = 0.
6
Clamp Input Signal Polarity
This bit determines the polarity of the externally
provided CLAMP signal.
This function needs to be used along with the Coast
Polarity Override bit (Bit 4).
The power-up default value is 1.
Table 22. Clamp Input Signal Polarity Settings
Clamp Function
1
0
Function
Active Low
Active High
0F
Logic 1 means that the circuit will clamp when
CLAMP is low, and it will pass the signal to the ADC
when CLAMP is high.
Logic 0 means that the circuit will clamp when
CLAMP is high, and it will pass the signal to the ADC
when CLAMP is low.
Select
1
0
Table 23. Power-Down Settings
0F
Result
Coast Input Pin
Vsync (See above Text)
0F
1
PWRDN
This bit is used to put the chip in full power-down. See
the Power Management section for details of which
blocks are powered down.
Table 27. Power-Down Settings
Select
0
1
10
4
Coast Input Polarity Override
This register is used to override the internal circuitry
that determines the polarity of the Coast signal going
into the PLL.
Table 24. Coast Input Polarity Override Settings
Override Bit
0
1
Result
Allow Seek Mode
Disallow Seek Mode
The default for this register is 1.
5
Coast Select
This bit is used to select the active Coast source. The
choices are the Coast Input pin or Vsync. If Vsync is
selected, the additional decision of using the Vsync
input pin or the output from the sync separator needs
to be made (Register 0E, Bits 1, 0).
Select
0
1
2
Seek Mode Override
This bit is used to either allow or disallow the low
power mode. The low power mode (Seek Mode)
occurs when there are no signals on any of the Sync
inputs.
Table 26. Seek Mode Override Settings
The power-up default value is Clamp Polarity = 1.
0F
Function
Active Low
Active High
Active Low means that the clock generator will ignore
Hsync inputs when Coast is low, and continue
operating at the same nominal frequency until Coast
goes high.
A 1 enables the external CLAMP input pin. The three
channels are clamped when the CLAMP signal is
active. The polarity of CLAMP is determined by the
Clamp Polarity bit (Register 0FH, Bit 6).
0F
3
Coast Input Polarity
This bit indicates the polarity of the Coast signal that
is applied to the PLL COAST input.
Result
Power-Down
Normal Operation
7-3
Sync-on-Green Slicer Threshold
This register allows the comparator threshold of the
Sync-on-Green slicer to be adjusted. This register
adjusts it in steps of 10 mV, with the minimum setting
equaling 10 mV (11111) and the maximum setting
equaling 330 mV (00000).
The default setting is 23, which corresponds to a
threshold value of 100 mV; for a threshold of 150 mV,
the setting should be 18.
Result
Determined by Chip
Determined by User
Rev. 0 | Page 22 of 32
AD9985
10
2
Red Clamp Select
This bit determines whether the Red channel is
clamped to ground or to midscale. For RGB video, all
three channels are referenced to ground. For YCbCr
(or YUV), the Y channel is referenced to ground, but
the CbCr channels are referenced to midscale.
Clamping to midscale actually clamps to Pin 37.
Function
Clamp to Ground
Clamp to Midscale (Pin 37)
Detect
0
1
1
Green Clamp Select
This bit determines whether the Green channel is
clamped to ground or to midscale.
Function
Clamp to Ground
Clamp to Midscale (Pin 37)
14
The default setting for this register is 0.
10
0
Blue Clamp Select
This bit determines whether the Blue channel is
clamped to ground or to midscale.
Table 30. Blue Clamp Select Settings
Clamp
0
1
Function
Clamp to Ground
Clamp to Midscale (Pin 37)
7–0
Sync Separator Threshold
This register is used to set the responsiveness of the
sync separator. It sets how many internal 5 MHz clock
periods the sync separator must count to before
toggling high or low. It works like a low-pass filter to
ignore Hsync pulses in order to extract the Vsync
signal. This register should be set to some number
greater than the maximum Hsync pulsewidth. Note
that the sync separator threshold uses an internal
dedicated clock with a frequency of approximately
5 MHz.
Bit 7
(Hsync
Detect)
0
0
1
1
X
Bit 1
(SOG
Detect)
0
1
0
1
X
Bit 4,
Reg 0EH
(Override)
0
0
0
0
1
AHS
Bit 3 in 0EH
1
0
Bit 3 in 0EH
Bit 3 in 0EH
AHS = 0 means use the Hsync pin input for Hsync.
AHS = 1 means use the SOG pin input for Hsync.
The override bit is in Register 0EH, Bit 4.
14
The default for this register is 32.
12
6
AHS – Active Hsync
This bit indicates which Hsync input source is being
used by the PLL (Hsync input or Sync-on-Green).
Bits 7 and 1 in this register determine which source is
used. If both Hsync and SOG are detected, the user
can determine which has priority via Bit 3 in
Register 0EH. The user can override this function via
Bit 4 in Register 0EH. If the override bit is set to
Logic 1, this bit will be forced to whatever the state of
Bit 3 in Register 0EH is set to.
Table 32. Active Hsync Results
The default for this register is 0.
11
Function
No Activity Detected
Activity Detected
The Sync Processing Block Diagram (Figure 14) shows
where this function is implemented.
Table 29. Green Clamp Select Settings
Clamp
0
1
7
Hsync Detect
This bit is used to indicate when activity is detected on
the Hsync input pin (Pin 30). If Hsync is held high or
low, activity will not be detected.
Table 31. Hsync Detection Results
The default setting for this register is 0.
10
7–0 Post-Coast
This register allows the coast signal to be applied
following the Vsync signal. This is necessary in cases
where post-equalization pulses are present. The step
size for this control is one Hsync period.
The default is 0.
14
Table 28. Red Clamp Select Settings
Clamp
0
1
13
7–0 Pre-Coast
This register allows the coast signal to be applied prior
to the Vsync signal. This is necessary in cases where
pre-equalization pulses are present. The step size for
this control is one Hsync period.
The default is 0.
Rev. 0 | Page 23 of 32
5
Detected Hsync Input Polarity Status
This bit reports the status of the Hsync input polarity
detection circuit. It can be used to determine the
polarity of the Hsync input. The detection circuit’s
location is shown in the Sync Processing Block
Diagram (Figure 14).
AD9985
Table 33. Detected Hsync Input Polarity Status
Hsync Polarity
Status
0
1
14
4
Result
Table 37. Sync-on-Green Detection Results
Negative
Positive
Detect
0
1
Vsync Detect
This bit is used to indicate when activity is detected on
the Vsync input pin (Pin 31). If Vsync is held steady
high or low, activity will not be detected.
The Sync Processing Block Diagram (Figure 14) shows
where this function is implemented.
14
Table 34. Vsync Detection Results
Detect
0
1
Function
No Activity Detected
Activity Detected
The Sync Processing Block Diagram (Figure 14) shows
where this function is implemented.
14
3
AVS – Active Vsync
This bit indicates which Vsync source is being used:
the Vsync input or output from the sync separator.
Bit 4 in this register determines which is active. If both
Vsync and SOG are detected, the user can determine
which has priority via Bit 0 in Register 0EH. The user
can override this function via Bit 1 in Register 0EH. If
the override bit is set to Logic 1, this bit will be forced
to whatever the state of Bit 0 in Register 0EH is set to.
Bit 1, Reg 0EH
(Override)
0
0
1
0
Detected Coast Polarity Status
This bit reports the status of the Coast input polarity
detection circuit. It can be used to determine the
polarity of the Coast input. The detection circuit’s
location is shown in the Sync Processing Block
Diagram (Figure 14).
Table 38. Detected Coast Input Polarity Status
Polarity Status
0
1
Result
Coast Polarity Negative
Coast Polarity Positive
This indicates that Bit 1 of Register 5 is the 4:2:2
output mode select bit.
15
Table 35. Active Vsync Results
Bit 4, Reg 14H
(Vsync Detect)
1
0
X
Function
No Activity Detected
Activity Detected
1
4:2:2 Output Mode Select
This bit configures the output data in 4:2:2 mode. This
mode can be used to reduce the number of data lines
used from 24 down to 16 for applications using YUV,
YCbCr, or YPbPr graphics signals. A timing diagram
for this mode is shown in Figure 11.
Recommended input and output configurations are
shown in Table 39.
AVS
0
1
Bit 0 in 0EH
Table 39. 4:2:2 Output Mode Select
Select
0
1
AVS = 0 means Vsync input.
Output Mode
4:2:2
4:4:4
AVS = 1 means Sync separator.
Table 40. 4:2:2 Input/Output Configuration
The override bit is in Register 0EH, Bit 1.
14
2
Detected Vsync Output Polarity Status
This bit reports the status of the Vsync output polarity
detection circuit. It can be used to determine the
polarity of the Vsync output. The detection circuit’s
location is shown in the Sync Processing Block
Diagram (Figure 14).
Table 36. Detected Vsync Output Polarity Status
Vsync Polarity Status
0
1
14
19
7:0
Output Format
U/V
Y
High Impedance
Red Target Code
This specifies the targeted value of the final offset for
the Red channel when auto offset is employed
(Register 0x1D Bit 7 = 1). Default is 4.
Result
Active Low
Active High
1
Sync-on-Green Detect
This bit is used to indicate when sync activity is
detected on the Sync-on-Green input pin (Pin 49).
Input
Connection
V
Y
U
Channel
Red
Green
Blue
1A
7:0
Green Target Code
This specifies the targeted value of the final offset for
the Green channel when auto offset is employed
(Register 0x1D Bit 7 = 1). Default is 4.
Rev. 0 | Page 24 of 32
AD9985
1B
7:0
Blue Target Code
This specifies the targeted value of the final offset for
the Blue channel when auto offset is employed
(Register 0x1D Bit 7 = 1). Default is 4.
1D
7
Auto Offset Enable
Enables the auto offset circuitry. Default is 0.
1D
6
Hold Auto Offset
Holds the offset output of the auto offset at the current
value. Default is 0.
1D
1:0
Update Mode
Changes the update rate of the auto offset. Default is
‘10’.
Table 41. Auto Offset Update Rate
Update Mode
Auto-Offset Update Timing
00
01
10
Every Clamp cycle.
Every 16 Clamp cycles.
Every 64 Clamp cycles.
Rev. 0 | Page 25 of 32
AD9985
2-WIRE SERIAL CONTROL PORT
A 2-wire serial control interface (I2C) is provided. Up to two
AD9985 devices may be connected to the 2-wire serial interface,
with each device having a unique address.
The 2-wire serial interface comprises a clock (SCL) and a
bidirectional data (SDA) pin. The analog flat panel interface
acts as a slave for receiving and transmitting data over the serial
interface. When the serial interface is not active, the logic levels
on SCL and SDA are pulled high by external pull-up resistors.
Data received or transmitted on the SDA line must be stable for
the duration of the positive-going SCL pulse. Data on SDA must
change only when SCL is low. If SDA changes state while SCL is
high, the serial interface interprets that action as a start or stop
sequence.
data transfer, read from (1) or write to (0) the slave device. If the
transmitted slave address matches the address of the device (set
by the state of the SA1-0 input pins in Table 42), the AD9985
acknowledges by bringing SDA low on the ninth SCL pulse. If
the addresses do not match, the AD9985 does not acknowledge.
Table 42. Serial Port Addresses
Bit 7
A6
(MSB)
1
1
Bit 6
A5
Bit 5
A4
Bit 4
A3
Bit 3
A2
Bit 2
A1
Bit 1
A0
0
0
0
0
1
1
1
1
0
0
0
1
DATA TRANSFER VIA SERIAL INTERFACE
For each byte of data read or written, the MSB is the first bit of
the sequence.
There are five components to serial bus operation:
•
•
•
•
•
If the AD9985 does not acknowledge the master device during a
write sequence, the SDA remains high so the master can
generate a stop signal. If the master device does not acknowledge the AD9985 during a read sequence, the AD9985
interprets this as “end of data.” The SDA remains high so the
master can generate a stop signal.
Start Signal
Slave Address Byte
Base Register Address Byte
Data Byte to Read or Write
Stop Signal
When the serial interface is inactive (SCL and SDA are high),
communications are initiated by sending a start signal. The start
signal is a high-to-low transition on SDA while SCL is high.
This signal alerts all slaved devices that a data transfer sequence
is coming.
The first eight bits of data transferred after a start signal
comprise a 7-bit slave address (the first seven bits) and a single
R/W bit (the eighth bit). The R/W bit indicates the direction of
Writing data to specific control registers of the AD9985 requires
that the 8-bit address of the control register of interest be
written after the slave address has been established. This control
register address is the base address for subsequent write operations. The base address autoincrements by one for each byte of
data written after the data byte intended for the base address.
SDA
tBUFF
tSTAH
tDSU
tDHO
tSTASU
tSTOSU
tDAL
04799-0-012
SCL
tDAH
Figure 12. Serial Port Read/Write Timing
Rev. 0 | Page 26 of 32
AD9985
Data is read from the control registers of the AD9985 in a
similar manner. Reading requires two data transfer operations:
The base address must be written with the R/W bit of the slave
address byte low to set up a sequential read operation.
•
•
•
•
•
Data Byte to Base Address
Data Byte to (Base Address + 1)
Data Byte to (Base Address + 2)
Data Byte to (Base Address + 3)
Stop Signal
Reading (the R/W bit of the slave address byte high) begins at
the previously established base address. The address of the read
register autoincrements after each byte is transferred.
Read from one control register
•
•
Start Signal
Slave Address Byte (R/W Bit = Low)
To terminate a read/write sequence to the AD9985, a stop signal
must be sent. A stop signal comprises a low-to-high transition
of SDA while SCL is high.
•
•
•
Base Address Byte
Start Signal
Slave Address Byte (R/W Bit = High)
•
•
Data Byte from Base Address
Stop Signal
Serial Interface Read/Write Examples
Write to one control register
•
•
Start Signal
Slave Address Byte (R/W Bit = Low)
• Base Address Byte
• Data Byte to Base Address
• Stop Signal
Write to four consecutive control registers
• Start Signal
• Slave Address Byte (R/W Bit = Low)
•
Read from four consecutive control registers
•
•
Start Signal
Slave Address Byte (R/W Bit = Low)
•
•
•
Base Address Byte
Start Signal
Slave Address Byte (R/W Bit = High)
•
•
•
•
•
Data Byte from Base Address
Data Byte from (Base Address + 1)
Data Byte from (Base Address + 2)
Data Byte from (Base Address + 3)
Stop Signal
SDA
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SCL
Base Address Byte
Figure 13. Serial Interface—Typical Byte Transfer
Rev. 0 | Page 27 of 32
ACK
04799-0-014
A repeated start signal occurs when the master device driving
the serial interface generates a start signal without first
generating a stop signal to terminate the current communication. This is used to change the mode of communication
(read, write) between the slave and master without releasing the
serial interface lines.
AD9985
ACTIVITY
DETECT
SYNC STRIPPER
NEGATIVE PEAK
CLAMP
SYNC SEPARATOR
COMP
SYNC
INTEGRATOR
VSYNC
1/S
SOG
MUX 1
HSYNC IN
SOG OUT
PLL
ACTIVITY
DETECT
POLARITY
DETECT
HSYNC OUT
HSYNC
CLOCK
GENERATOR
MUX 2
HSYNC OUT
PIXEL CLOCK
COAST
COAST
MUX 3
POLARITY
DETECT
AD9985
VSYNC IN
ACTIVITY
DETECT
POLARITY
DETECT
04799-0-0015
VSYNC OUT
MUX 4
Figure 14. Sync Processing Block Diagram
Table 43. Control of the Sync Block Muxes via the Serial Register
Mux No.
1 and 2
Serial Bus
Control Bit
0EH: Bit 3
3
0FH: Bit 5
4
0EH: Bit 0
Control
Bit State
0
1
0
1
0
1
Result
Pass Hsync
Pass Sync-on-Green
Pass Coast
Pass Vsync
Pass Vsync
Pass Sync Separator Signal
SYNC SLICER
The purpose of the sync slicer is to extract the sync signal from
the Green graphics channel. A sync signal is not present on all
graphics systems, only those with Sync-on-Green. The sync
signal is extracted from the Green channel in a two-step
process. First, the SOG input is clamped to its negative peak
(typically 0.3 V below the black level). Next, the signal goes to a
comparator with a variable trigger level, nominally 0.15 V above
the clamped level. The “sliced” sync is typically a composite sync
signal containing both Hsync and Vsync.
SYNC SEPARATOR
A sync separator extracts the Vsync signal from a composite
sync signal. It does this through a low-pass filter-like or
integrator-like operation. It works on the idea that the Vsync
signal stays active for a much longer time than the Hsync signal,
so it rejects any signal shorter than a threshold value, which is
somewhere between an Hsync pulsewidth and a Vsync
pulsewidth.
The sync separator on the AD9985 is simply an 8-bit digital
counter with a 5 MHz clock. It works independently of the
polarity of the composite sync signal. (Polarities are determined
elsewhere on the chip.) The basic idea is that the counter counts
up when Hsync pulses are present. But since Hsync pulses are
relatively short in width, the counter only reaches a value of N
before the pulse ends. It then starts counting down, eventually
reaching 0 before the next Hsync pulse arrives. The specific
value of N will vary for different video modes, but will always
be less than 255. For example, with a 1 µs width Hsync, the
counter will only reach 5 (1 µs/200 ns = 5). When Vsync is
present on the composite sync, the counter will also count up.
However, since the Vsync signal is much longer, it will count to
a higher number M. For most video modes, M will be at least
255. So, Vsync can be detected on the composite sync signal by
detecting when the counter counts to higher than N. The
specific count that triggers detection (T) can be programmed
through the serial register (11H).
Once Vsync has been detected, there is a similar process to
detect when it goes inactive. At detection, the counter first resets
to 0, then starts counting up when Vsync goes away. Similar to
the previous case, it will detect the absence of Vsync when the
counter reaches the threshold count (T). In this way, it will
reject noise and/or serration pulses. Once Vsync is detected to
be absent, the counter resets to 0 and begins the cycle again.
Rev. 0 | Page 28 of 32
AD9985
PCB LAYOUT RECOMMENDATIONS
The AD9985 is a high precision, high speed analog device. As
such, to get the maximum performance from the part, it is
important to have a well laid out board. The following is a guide
for designing a board using the AD9985.
power plane to the capacitor to the power pin. Do not make the
power connection between the capacitor and the power pin.
Placing a via underneath the capacitor pads, down to the power
plane, is generally the best approach.
ANALOG INTERFACE INPUTS
It is particularly important to maintain low noise and good
stability of PVD (the clock generator supply). Abrupt changes in
PVD can result in similarly abrupt changes in sampling clock
phase and frequency. This can be avoided by careful attention to
regulation, filtering, and bypassing. It is highly desirable to
provide separate regulated supplies for each of the analog
circuitry groups (VD and PVD).
Use 75 Ω matched impedance traces. Trace impedances other
than 75 Ω will also increase the chance of reflections.
The AD9985 has very high input bandwidth (500 MHz). While
this is desirable for acquiring a high resolution PC graphics
signal with fast edges, it means that it will also capture any high
frequency noise present. Therefore, it is important to reduce the
amount of noise that gets coupled to the inputs. Avoid running
any digital traces near the analog inputs.
In some cases, using separate ground planes is unavoidable. For
those cases, it is recommended to at least place a single ground
plane under the AD9985. The location of the split should be at
the receiver of the digital outputs. For this case it is even more
important to place components wisely because the current
loops will be much longer (current takes the path of least
resistance). An example of a current loop is shown in Figure 15.
POWER SUPPLY BYPASSING
LAN
DP
UN
O
R
G
DI
It is recommended to bypass each power supply pin with a
0.1 µF capacitor. The exception is when two or more supply pins
are adjacent to each other. For these groupings of powers/
grounds, it is necessary to have only one bypass capacitor. The
fundamental idea is to have a bypass capacitor within about
0.5 cm of each power pin. Also, avoid placing the capacitor on
the opposite side of the PC board from the AD9985, as that
interposes resistive vias in the path.
The bypass capacitors should be physically located between the
power plane and the power pin. Current should flow from the
Rev. 0 | Page 29 of 32
GI
TA
L
POWER PLANE
E
AD988
3A
DI
GI
T
TPUT T
OU
RA
AL
Due to the high bandwidth of the AD9985, low-pass filtering
the analog inputs can sometimes help to reduce noise. (For
many applications, filtering is unnecessary.) Experiments have
shown that placing a series ferrite bead prior to the 75 Ω
termination resistor is helpful in filtering out excess noise.
Specifically, the part used was the #2508051217Z0 from FairRite, but each application may work best with a different bead
value. Alternately, placing a 100 Ω to 120 Ω resistor between the
75 Ω termination resistor and the input coupling capacitor can
also be beneficial.
It is also recommended to use a single ground plane for the
entire board. Experience has repeatedly shown that the noise
performance is the same or better with a single ground plane.
Using multiple ground planes can be detrimental because each
separate ground plane is smaller, and long ground loops can
result.
GR
O UN
D PL A
NE
DIGITAL DATA R
Figure 15. Current Loop
ECEI
VE R
04799-0-016
Place the 75 Ω termination resistors (see Figure 3) as close to
the AD9985 chip as possible. Any additional trace length
between the termination resistors and the input of the AD9985
increases the magnitude of reflections, which will corrupt the
graphics signal.
Some graphic controllers use substantially different levels of
power when active (during active picture time) and when idle
(during horizontal and vertical sync periods). This can result in
a measurable change in the voltage supplied to the analog
supply regulator, which can in turn produce changes in the
regulated analog supply voltage. This can be mitigated by
regulating the analog supply, or at least PVD, from a different,
cleaner power source (for example, from a 12 V supply).
ANALO
G
Minimize the trace length running into the graphics inputs.
This is accomplished by placing the AD9985 as close as possible
to the graphics VGA connector. Long input trace lengths are
undesirable because they pick up more noise from the board
and other external sources.
CE
Using the following layout techniques on the graphics inputs is
extremely important.
AD9985
PLL
Place the PLL loop filter components as close to the FILT pin as
possible.
to add vias or extra length to the output trace in order to get the
resistors closer).
Do not place any digital or other high frequency traces near
these components.
If possible, limit the capacitance that each of the digital outputs
drives to less than 10 pF. This can easily be accomplished by
keeping traces short and by connecting the outputs to only one
device. Loading the outputs with excessive capacitance will
increase the current transients inside of the AD9985, creating
more digital noise on its power supplies.
Use the values suggested in the data sheet with 10% tolerances
or less.
OUTPUTS (BOTH DATA AND CLOCKS)
Try to minimize the trace length that the digital outputs have to
drive. Longer traces have higher capacitance, which requires
more current, which causes more internal digital noise.
Shorter traces reduce the possibility of reflections.
Adding a series resistor of value 22 Ω to 100 Ω can suppress
reflections, reduce EMI, and reduce the current spikes inside of
the AD9985. However, if 50 Ω traces are used on the PCB, the
data outputs should not need resistors. A 22 Ω resistor on the
DATACK output should provide good impedance matching
that will reduce reflections. If series resistors are used, place
them as close to the AD9985 pins as possible (although try not
DIGITAL INPUTS
The digital inputs on the AD9985 were designed to work with
3.3 V signals, but are tolerant of 5.0 V signals. Therefore, no
extra components need to be added if using 5.0 V logic.
Any noise that gets onto the Hsync input trace will add jitter to
the system. Therefore, minimize the trace length and do not run
any digital or other high frequency traces near it.
VOLTAGE REFERENCE
Bypass with a 0.1 µF capacitor. Place as close to the AD9985 pin
as possible. Make the ground connection as short as possible.
Rev. 0 | Page 30 of 32
AD9985
OUTLINE DIMENSIONS
0.75
0.60
0.45
16.00
BSC SQ
1.60
MAX
61
80
60
1
SEATING
PLANE
PIN 1
14.00
BSC SQ
TOP VIEW
(PINS DOWN)
10°
6°
2°
1.45
1.40
1.35
0.15
0.05
SEATING
PLANE
0.20
0.09
7°
3.5°
0°
0.10 MAX
COPLANARITY
VIEW A
20
41
40
21
0.65
BSC
VIEW A
0.38
0.32
0.22
ROTATED 90° CCW
COMPLIANT TO JEDEC STANDARDS MS-026-BEC
Figure 16. 80-Lead Low Profile Quad Flat Package (LQFP)
(ST-80-2)
Dimensions shown in millimeters
ORDERING GUIDE
Model
AD9985KSTZ-1101
AD9985KSTZ-1401
AD9985BSTZ-1101
AD9985/PCB
1
Temperature Range
0°C to 70°C
0°C to 70°C
–40°C to +85°C
25°C
Z = Pb-free part.
Rev. 0 | Page 31 of 32
Package Description
LQFP
LQFP
LQFP
Evaluation Board
Package
ST-80
ST-80
ST-80
AD9985
NOTES
Purchase of licensed I2C components of Analog Devices or one of its sublicensed Associated Companies conveys a license for the purchaser under the Philips I2C
Patent Rights to use these components in an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips.
© 2004 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D04799-0-5/04(0)
Rev. 0 | Page 32 of 32