DE (ADE) VDE Compliant with European standards 1a1b 10A/8A polarized power relays RoHS compliant DE RELAYS (ADE) FEATURES TYPICAL APPLICATIONS 1. Conforms to European safety standard (VDE0700 and VDE0631). Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage Min. 8mm .315 inch 2. Low operating power Nominal operating power at 200 mW (Single side stable, 2 coil latching) 3. Compact body saves space Size: 12.5(W) × 25(L) × 12.5(H) mm .492(W) × .984(L) × .492(H) inch 4. Conforms to the various safety standards UL, CSA and VDE approved 1. Temperature controller 2. Automatic meter reading 3. OA equipment 4. FA equipment ORDERING INFORMATION ADE DE relay Contact arrangement 1: 1 Form A 2: 2 Form A 3: 1 Form A 1 Form B Operating function 0: Single side stable 2: 2 coil latching Nominal coil voltage (V DC) 3: 12V, 4: 24V, 9: 5V Notes: 1. Certified by UL, CSA and VDE 2. This product is manufactured by lot after an order is received. TYPES Contact arrangement 1 Form A 1 Form A 1 Form B 2 Form A Nominal coil voltage 5V DC 12V DC 24V DC 5V DC 12V DC 24V DC 5V DC 12V DC 24V DC Single side stable type Part No. ADE109 ADE103 ADE104 ADE309 ADE303 ADE304 ADE209 ADE203 ADE204 2 coil latching type Part No. ADE129 ADE123 ADE124 ADE329 ADE323 ADE324 ADE229 ADE223 ADE224 Standard packing: Tube package: 20 pcs.; Case: 500 pcs. Note: This product is manufactured by lot after an order is received. Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB175E 201202-T DE (ADE) RATING 1. Coil data 1) Single side stable type Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) 5V DC 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) 12V DC 24V DC Nominal operating current [±10%] (at 20°C 68°F) 40 mA 16.6mA 8.3mA Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 720Ω 2,880Ω 200mW 130%V of nominal voltage Coil resistance [±10%] (at 20°C 68°F) Nominal operating power 125Ω 2) 2 coil latching type Nominal coil voltage Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) 5V DC 70%V or less of nominal voltage (Initial) 70%V or less of nominal voltage (Initial) 12V DC 24V DC Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil 40 mA 40 mA 16.6mA 8.3mA 16.6mA 8.3mA Set coil 125Ω Reset coil 125Ω Set coil Reset coil 720Ω 2,880Ω 720Ω 2,880Ω 200mW 200mW Max. applied voltage (at 20°C 68°F) 130%V of nominal voltage 2. Specifications Characteristics Contact Rating Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity*1 Insulation resistance (Initial) Between open contacts Between contact sets Between contact and coil Surge breakdown voltage*2 (Between contact and coil) (Initial) Temperature rise (coil) (at 70°C 158°F) Breakdown voltage (Initial) Electrical characteristics Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance Mechanical characteristics Expected life Conditions Electrical Conditions for operation, transport and storage*3 Max. operating speed Unit weight Specifications 1 Form A 1 Form B 2 Form A Max. 30 mΩ (By voltage drop 6 V DC 1A) AgSnO2 type 10A 250V AC, 10A 30V DC 8A 250V AC, 8A 30V DC 2,500VA, 300W 2,000VA, 240W 250V AC, 30V DC 250V AC, 30V DC 10A 8A 200mW 100mA 5V DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. 1 Form A — 1,000 Vrms for 1 min. (Detection current: 10 mA) 4,000 Vrms for 1 min. (Detection current: 10 mA) 5,000 Vrms for 1 min. (Detection current: 10 mA) 12,000 V Max. 50°C 122°F (By resistive method) Max. 10 ms [Max. 10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 5 ms [Max. 10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 3 mm Min. 107 (at 300 times/min.) Min. 105 (resistive load, at 20 times/min., at AC nominal Min. 105 switching capacity) (resistive load, at 20 times/min., at nominal switching capacity) Min. 5×104 (resistive load, at 20 times/min., at DC nominal switching capacity) Ambient temperature: –40°C to +70°C –40°F to +158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 7 g .25 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. ASCTB175E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ DE (ADE) REFERENCE DATA 1.-(1) Maximum switching power (1 Form A) 1.-(2) Maximum switching power (1 Form A 1 Form B, 2 Form A) 100 AC resistive load 10 DC resistive load 1 0.1 100 50 250 V AC resistive load 30 V DC resistive load AC resistive load Life, ×104 Contact current, A Contact current, A 100 2.-(1) Life curve (1 Form A) 10 10 DC resistive load 1 1 10 0.1 100 1000 Contact voltage, V 2.-(2) Life curve (1 Form A 1 Form B) 1 10 1000 100 Contact voltage, V 2.-(3) Life curve (2 Form A) 0 1 2 3 4 5 6 7 8 Contact current, A 9 10 3.-(1) Coil temperature rise (1 Form A) Tested sample: ADE109 Quantity: n=6 Ambient temperature: 25°C to 70°C 77°F to 158°F 50 50 250 V AC resistive load 30 V DC resistive load 50 Life, ×104 250 V AC resistive load 10 10 Temperature rise, °C 100 Life, ×104 100 25°C 77°F 70°C 158°F 40 10A 0A 10A 0A 30 20 30 V DC resistive load 10 0 1 2 3 4 5 6 7 8 Contact current, A 9 0 10 1 2 3 4 5 6 7 8 Contact current, A 9 0 10 70 80 90 100 110 120 Coil applied voltage, %V 130 3.-(2) Coil temperature rise (1 Form A 1 Form B) 3.-(3) Coil temperature rise (2 Form A) 4.-(1) Operate/release time (1 Form A) Tested sample: ADE309 Quantity: n=6 Ambient temperature: 25°C to 70°C 77°F to 158°F Tested sample: ADE209 Quantity: n=6 Ambient temperature: 25°C to 70°C 77°F to 158°F Tested sample: ADE109 Quantity: n=5 40 8A 0A 8A 30 0A 20 10 9 25°C 77°F 70°C 158°F 8A 40 8A 0A 0A 30 20 Operate/release time, ms 50 25°C 77°F 70°C 158°F Temperature rise, °C Temperature rise, °C 50 8 Operate time 7 6 Max. x Min. Max. x Min. 5 4 3 2 10 Release time (With diode) Max. x Min. 1 0 70 80 0 90 100 110 120 130 Coil applied voltage, %V 70 80 90 100 110 120 130 Coil applied voltage, %V 4.-(2) Operate/release time (1 Form A 1 Form B) 4.-(3) Operate/release time (2 Form A) Tested sample: ADE309, Quantity: n=5 Tested sample: ADE209, Quantity: n=5 Release time 0 70 80 90 100 110 120 130 Coil applied voltage, %V 5.-(1) Ambient temperature characteristics (1 Form A) Tested sample: ADE109, Ambient temperature: –40°C to 80°C –40°F to 176°F, Quantity: n=6 6 Max. x Min. 5 4 3 Max. x Min. Max. x Min. Operate time 2 7 Operate time 6 Max. x Max. Min. x Min. 5 4 3 Release time 70 80 90 100 110 120 130 Coil applied voltage, %V Panasonic Corporation 0 –20 –4 Max. x Min. 1 0 –40 –40 Release time (With diode) 2 1 Rate of change, V% 8 Release time (With diode) Operate/release time, ms Operate/release time, ms 7 30 20 10 0 Drop-out voltage Pick-up voltage 0 20 40 60 80 32 68 104 140 176 –10 Ambient –20 temperature,°C °F –30 Release time 70 80 90 100 110 120 130 Coil applied voltage, %V Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB175E 201202-T DE (ADE) Tested sample: ADE309, Ambient temperature: –40°C to 80°C –40°F to 176°F, Quantity: n=6 Tested sample: ADE209, Ambient temperature: –40°C to 80°C –40°F to 176°F, Quantity: n=6 –40 –40 –20 –4 Rate of change, V% 5.-(3) Ambient temperature characteristics (2 Form A) Rate of change, V% 5.-(2) Ambient temperature characteristics (1 Form A 1 Form B) 30 Drop-out 20 voltage 10 0 Pick-up voltage 0 20 40 60 80 32 68 104 140 176 –10 Ambient temperature,°C °F –20 –40 –40 –20 –4 0 32 –10 –20 –30 30 Drop-out 20 voltage Pick-up voltage 10 0 20 40 60 80 68 104 140 176 Ambient temperature,°C °F –30 DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data PC board pattern (Bottom view) Single side stable Single side stable 25.0 .984 12.5 .492 15.24 .600 12.0 .472 7.62 .300 0.8 .032 1.0 .039 2.44 .096 12.70 .500 8-1.2 dia. 8-.047 dia. 7.62 .300 7.62 .300 0.4 .016 7.62 .300 Tolerance : ±0.1 ±.004 Schematic (Bottom view) 2 coil latching type 12.5 .492 12.0 .472 0.5 .020 1 3 4 8 6 5 7.62 .300 0.8 .032 1.0 .039 2.44 .096 0.4 .016 7.62 .300 Tolerance: ±0.3 ±.012 3 4 1 3 4 8 6 5 8 6 5 (Deenergized condition) (1 Form A) 2coil latching type (1 Form A 1 Form B) 1 2 3 4 1 8 7 6 5 8 (5,6: dummy terminal) (2 Form A) 1 (5,6: dummy terminal) 3.5 .138 0.8 .032 0.5 dia. .020 dia. 12.70 .500 Single side stable (1 Form A 1 Form B) (1 Form A) 25.0 .984 2.54 .100 2.54 .100 3.5 .138 0.8 .032 15.24 .600 0.5 dia. .020 dia. 6-1.2 dia. 6-.047 dia. 7.62 .300 0.5 .020 0.5 dia. .020 dia. 7.62 .300 2 coil latching type (2 Form A) 2 3 4 1 2 3 4 7 6 5 8 7 6 5 (Reset condition) SAFETY STANDARDS Item 1 Form A 1 Form A 1 Form B 2 Form A File No. E120782 E120782 E120782 UL/C-UL (Recognized) Contact rating PILOT DUTY B300 R300 PILOT DUTY B300 R300 PILOT DUTY B300 R300 File No. LR85932 LR85932 LR85932 CSA (Certified) Contact rating PILOT DUTY B300 R300 PILOT DUTY B300 R300 PILOT DUTY B300 R300 File No. 115944 VDE (Certified) Contact rating 8A 250V AC (cosφ =1.0) 115944 8A 250V AC (cosφ =1.0) 115944 8A 250V AC (cosφ =1.0) For Cautions for Use. ASCTB175E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/