AC-DC 15 Watts xppower.com AEL Series • CEC 2008 & EISA 2007 Compliant • Approved as LPS • China Compulsory Certfication (CCC) Qualified • High Efficiency • +70 °C Operating Temperature • Compact Dimensions • Optional Input Connector Specification Input Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current Power Factor Input Protection Standby Power Consumption General • • • • • • • • 90-264 VAC 47-63 Hz 0.4 A at 115 VAC 15 A/30 A for 115 VAC/230 VAC, cold start 0.75 mA at 240 VAC Meets EN61000-3-2 Fitted with internal fuse Typically 0.3 W, max 0.5 W Output Voltage Minimum Load Hold Up Time Start Up Delay Transient Response • • • • • Line Regulation Load Regulation Ripple & Noise Short Circuit Protection Temperature Coefficient • • • • • See tables No minimum load required 5 ms min at full load 110 VAC 2.0 s at full load 100 VAC 2% deviation, recovery to within 1% of nominal in 4 ms for 50% load change See tables See tables 1% pk-pk max, 20 MHz BW. See note 3. Trip & restart (Hiccup mode), auto recovery ±0.04%/°C Output Efficiency Isolation Switching Frequency MTBF • 85% typical • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground • 63 kHz typical • 300 kHrs to MIL-STD-217F Environmental Operating Temperature • 0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Vibration • 5-100 Hz 2.31 m/s2, 20 mins 3 axes EMC & Safety Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55022 FCC Part-15C Level B conducted & radiated • EN61000-3-2 Class A • EN61000-3-3 • EN61000-4-2 Level 3 Perf criteria A • EN61000-4-3 3 V/m Perf criteria A • EN61000-4-4 Level 2 Perf criteria A • EN61000-4-5 Level 3 Perf criteria A • EN61000-4-6 Level 2 Perf criteria A • EN61000-4-8 1 A/m Perf criteria A • EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B • EN60950-1:2001, UL/cUL60950-1, Approved as Limited Power Source, CE Mark, China Compulsory Certification (CCC) qualified. Max Output Power Output Voltage (4) Output Current Total Regulation(2) Model Number(1) 8W 3.3 VDC 2.50 A 7% AEL15US03 12 W 5 VDC 2.40 A 7% AEL15US05 8 VDC 1.87 A 5% AEL15US08 9 VDC 1.66 A 5% AEL15US09 12 VDC 1.25 A 5% AEL15US12 15 VDC 1.00 A 5% AEL15US15 18 VDC 0.83 A 5% AEL15US18 24 VDC 0.62 A 5% AEL15US24 30 VDC 0.50 A 5% AEL15US30 36 VDC 0.42 A 3% AEL15US36 48 VDC 0.31 A 3% AEL15US48 15 W Notes 1. 2. 3. 4. Standard input connector is IEC320-C14 Inlet. For optional IEC320-C6 Inlet, add suffix “C6” to model number e.g. AEL15US12C6. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. Measured at 25 ºC Other output voltages available, contact sales for details. Mechanical Details 1.42 ±0.04 (36.0 ±1.0) 1.50 ±0.04 (38.0 ±1.0) 3.58 ±0.04 (91.0 ±1.0) AC INPUT IEC-320-C6 INLET AC INPUT IEC-320-C14 INLET Notes 1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48” (1220mm) approx. Weight is 0.36 lbs (165 g) For European mains lead order part: EU-MAINS-IEC or EU-MAINS-5 for C6 version. For UK mains lead order part: UK-MAINS-IEC or UK-MAINS-5 for C6 version. For US mains lead order part: US-MAINS-IEC or US-MAINS-5 for C6 version. 01-Dec-08 AC-DC AEL15 Models and Ratings AC-DC 20-60 Watts xppower.com AEL Series • CEC 2008 & EISA 2007 Compliant • Approved as LPS • China Compulsory Certfication (CCC) Qualified • Up to 88% Efficiency • +70 °C Operating Temperature • Compact Dimensions • 20 W Optional Class II Insulation Specification Input Input Voltage Input Frequency Input Current • 90-264 VAC • 47-63 Hz • 0.4 A max AEL20 1.0 A max AEL40 1.6 A max AEL60 Inrush Current • 15 A/30 A for 115 VAC/230 VAC, cold start Earth Leakage Current • 0.75 mA at 240 VAC (except C2 version) Power Factor • Meets EN61000-3-2 Input Protection • Fitted with internal fuse, 1 A AEL20, 2 A AEL40/60 Standby Power • Typically 0.3 W, max 0.5 W Consumption Output Output Voltage Minimum Load Hold Up Time • See tables • No minimum load required • 12 ms min AEL20, 16 ms AEL40/60, at full load 110 VAC Start Up Delay • 0.5 s AEL20/40, 2.0 s AEL60, at full load 100 VAC Transient Response • 2% deviation, recovery to within 1% of nominal in 500 µs for 50% load change Line Regulation • See tables Load Regulation • See tables Ripple & Noise • 1% pk-pk max, 20 MHz BW Overvoltage Protection • 112-132% Overload Protection • 110-150% Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery Temperature • ±0.04%/°C Coefficient General Efficiency Isolation Switching Frequency MTBF • 85% typical AEL20/40, 88% typical AEL60 • 3000 VAC Input to Output 1500 VAC Input to Ground (not C2 version) 500 VDC Output to Ground (not C2 version) • 63 kHz typical • 300 kHrs AEL20, 200 kHrs AEL40, 130 kHrs AEL60 to MIL-STD-217F Environmental Operating Temperature • 0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Vibration • 5-100 Hz 2.31 m/s2, 20 mins 3 axes EMC & Safety Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55022 FCC Part-15C Level B conducted & radiated • EN61000-3-2 Class A • EN61000-3-3 • EN61000-4-2 Level 3 Perf criteria A • EN61000-4-3 3 V/m Perf criteria A • EN61000-4-4 Level 2 Perf criteria A • EN61000-4-5 Level 3 Perf criteria A • EN61000-4-6 Level 2 Perf criteria A • EN61000-4-8 1 A/m Perf criteria A • EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B • EN60950-1:2001, UL/cUL60950-1, Approved as Limited Power Source, CE Mark, China Compulsory Certification (CCC) qualified. Max Output Power 15 W 20 W Output Voltage(3) Output Current Total Regulation(2) Model Number(1) 5 VDC 3.00 A 5% AEL20US05 12 VDC 1.67 A 4% AEL20US12 15 VDC 1.33 A 4% AEL20US15 24 VDC 0.83 A 3% AEL20US24 30 VDC 0.67 A 3% AEL20US30 48 VDC 0.42 A 3% AEL20US48 Notes 1. For optional Class II version on AEL20 models only, add suffix ‘C2’ to model number e.g. AEL20US12C2. 2. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 3. Other output voltages available, contact sales for details. Mechanical Details 0.02 (0.5) 0.04 (1.0) 1.22 (31.0) 1.65 (42.0) 3.90 (99.0) AC INPUT IEC-320-C6 INLET AC INPUT IEC-320-C8 INLET (Optional C2 Version) Notes 1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48” (1220mm) approx. Weight is 0.37 lbs (170 g) For European mains lead order part: EU-MAINS-C5 for AEL20, EU-MAINS-8 for AEL20 Class II. For UK mains lead order part: UK-MAINS-5 for AEL20, UK-MAINS-8 for AEL20 Class II. For US mains lead order part: US-MAINS-5 for AEL20, US-MAINS-8 for AEL20 Class II. AC-DC AEL20 Models and Ratings Max Output Power 25 W 35 W 40 W Output Voltage(2) Output Current Total Regulation(1) Model Number 5 VDC 5.00 A 7% AEL40US05 8 VDC 4.37 A 5% AEL40US08 9 VDC 3.88 A 5% AEL40US09 12 VDC 3.33 A 5% AEL40US12 15 VDC 2.67 A 5% AEL40US15 18 VDC 2.22 A 5% AEL40US18 24 VDC 1.67 A 3% AEL40US24 36 VDC 1.11 A 3% AEL40US36 48 VDC 0.83 A 3% AEL40US48 Notes 1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details. Mechanical Details 0.04±0.004 (1.00±0.10) 0.04 (1.0) 1.36 (34.50) 4.65 (118.00) 0.02 (0.50) 2.05 (52.00) AC-DC AEL40 Models and Ratings AC INPUT IEC-320-C14 INLET Notes 1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48” (1220mm) approx. Weight is 0.70 lbs (300 g). For European mains lead order part: EU-MAINS-IEC. For UK mains lead order part: UK-MAINS-IEC. For US mains lead order part: US-MAINS-IEC. Max Output Power Output Voltage(2) Output Current Total Regulation(1) Model Number 57 W 12 VDC 4.75 A 5% AEL60US12 15 VDC 4.20 A 5% AEL60US15 18 VDC 3.50 A 5% AEL60US18 24 VDC 2.63 A 5% AEL60US24 30 VDC 2.15 A 5% AEL60US30 36 VDC 1.75 A 3% AEL60US36 48 VDC 1.31 A 3% AEL60US48 63 W Notes 1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details. Mechanical Details 0.04±0.004 (1.00±0.10) 0.04 (1.0) 1.36 (34.50) 4.65 (118.00) 2.05 (52.00) 0.02 (0.50) AC INPUT IEC-320-C14 INLET Notes 1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48” (1220mm) approx. Weight 0.70 lbs (300 g). For European mains lead order part: EU-MAINS-IEC. For UK mains lead order part: UK-MAINS-IEC. For US mains lead order part: US-MAINS-IEC. 01-Dec-08 AC-DC AEL60 Models and Ratings AC-DC 80 Watts xppower.com AEL80 Series • CEC 2008 & EISA 2007 Compliant • China Compulsory Certfication (CCC) Qualified • Output Voltages from 12 to 48 VDC • High Efficiency • +70 °C Operating Temperature • Compact Dimensions Specification Input Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current Power Factor Input Protection Standby Power Consumption General • • • • • • • • 90-264 VAC 47-63 Hz 1.1 A max 15 A/30 A for 115 VAC/230 VAC, cold start 0.75 mA at 240 VAC Meets EN61000-3-2 Fitted with internal fuse Typically 0.3 W, max 0.5 W Output Voltage Minimum Load Hold Up Time Start Up Delay Transient Response • • • • • Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient • • • • • • • See tables No minimum load required 16 ms min at full load 110 VAC 2.0 s at full load 100 VAC 2% deviation, recovery to within 1% of nominal in 500 µs for 50% load change See tables See tables 1% pk-pk max, 20 MHz BW 112-132% 110-150% Trip & restart (Hiccup mode), auto recovery ±0.04%/°C Output Efficiency Isolation Switching Frequency MTBF • 85% minimum • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground • 63 kHz typical • 300 kHrs to MIL-STD-217F Environmental Operating Temperature • 0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Vibration • 5-100 Hz 2.31 m/s2, 20 mins 3 axes EMC & Safety Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55022 FCC Part-15C Level B conducted & radiated • EN61000-3-2 Class A • EN61000-3-3 • EN61000-4-2 Level 3 Perf criteria A • EN61000-4-3 3 V/m Perf criteria A • EN61000-4-4 Level 2 Perf criteria A • EN61000-4-5 Level 3 Perf criteria A • EN61000-4-6 Level 2 Perf criteria A • EN61000-4-8 1 A/m Perf criteria A • EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B • EN60950-1:2001, UL/cUL60950-1, China Compulsory Certification (CCC) qualified, CE Mark. Max Output Power 80 W Output Voltage(2) Output Current Total Regulation(1) Model Number 12 VDC 6.66 A 5% AEL80US12 15 VDC 5.38 A 5% AEL80US15 18 VDC 4.44 A 5% AEL80US18 24 VDC 3.33 A 5% AEL80US24 30 VDC 2.66 A 5% AEL80US30 36 VDC 2.22 A 5% AEL80US36 48 VDC 1.66 A 5% AEL80US48 Notes 1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details. Mechanical Details AC Input IEC 320-C14 Inlet 1.69 (43.0) 2.99 (76.0) 5.75 (146.0) ±1.0 DC Output 3 5 2 1 4 DC Output 5 Pin Plug Pin Connections Pin Function 1 RTN 2 RTN 3 +ve 4 RTN 5 +ve Shell GND Notes 1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. Output connector: 5 pin 180º DIN Output cable length is 48” (1220mm) approx. Weight is 1.5 lbs (700 g) For European mains lead order part: EU-MAINS-IEC. For UK mains lead order part: UK-MAINS-IEC. For US mains lead order part: US-MAINS-IEC. 01-Dec-08 AC-DC AEL80 Models and Ratings