AIMTEC AM15EW-2415DZ 15 watt | dc-dc converter Datasheet

Series AM15EW-Z
15 Watt | DC-DC Converter
FEATURES:




RoHS compliant
Efficiency up to 86%
Wide 4:1 input range
Continuous Short Circuit Protection


●
●
Low ripple and noise
Remote on/off control
Input/Output Isolation 1500VDC
Operating temperature -40oC to + 85oC
Models
Single output
Model
AM15EW-2403SZ
AM15EW-2405SZ
AM15EW-2412SZ
AM15EW-2415SZ
AM15EW-4803SZ
AM15EW-4805SZ
AM15EW-4812SZ
AM15EW-4815SZ
Input Voltage
(V)
Output Voltage
(V)
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
3.3
5
12
15
3.3
5
12
15
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Capacitive load
(μF)
Efficiency
(%)
3300
3300
680
470
3300
3300
680
470
80
83
85
86
80
83
85
86
Capacitive load
(μF)
Efficiency
(%)
±2200
±470
±330
±2200
±470
±330
83
85
86
83
85
86
3
3
1.25
1
3
3
1.25
1
Models
Dual output
Model
AM15EW-2405DZ
AM15EW-2412DZ
AM15EW-2415DZ
AM15EW-4805DZ
AM15EW-4812DZ
AM15EW-4815DZ
9-36
9-36
9-36
18-72
18-72
18-72
Output Current
max (A)
±5
±12
±15
±5
±12
±15
±1.5
±0.625
±0.5
±1.5
±0.625
±0.5
Input Specifications
Parameters
Voltage range
Nominal
Typical
24
48
9-36
18-72
 (Pi) Network
2.5~5.5 or open circuit
-0.7~ 0.8 or short circuit b/n pin 2 & 1
Filter
Remote ON/OFF Control
ON
OFF
Turn on Transient process time
Start up time
Absolute Maximum Rating
Maximum
VDC
VDC
350
20
-0.7-40
-0.7-80
100
24 Vin
48 Vin
Peak Input Voltage time
Units
ms
ms
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Case/ Input & Output
Resistance
Capacitance
Conditions
Typical
3 sec
Rated
1500
1000
> 1000
1200
Units
VDC
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Voltage balance (Dual Output)
www.aimtec.com
F 051e R6.C
Conditions
Typical
Balance Load
±1
±1
Tel: +1 514 620 2722
1 of 3
Maximum
Units
%
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15EW-Z
15 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Short Circuit protection
Short Circuit restart
Current limiting
Line voltage regulation
Load voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Rising time
Conditions
Typical
Maximum
Units
140
% of Iout max
%
%
%
%/oC
mV p-p
ms
Continuous
Auto Recovery
HL-LL
10-100% load
below 10% load
±0.5
±0.5
±1.0
±0.02
75
10
At 20Mhz bandwidth
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
100% load
Typical
300
Derating above 60ºC
Maximum
Units
KHz
o
-40 to +85
-40 to +125
C
C
o
C
o
100
Free air convection
95
%
Nickel coated copper
30
g
Tolerance ±0.5mm
2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm
>1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified.
Safety Specifications
Standards
Agency Approvals
Standards
CE
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: also designed to meet IEC 60950 1:2001
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
6
On/Off Control
-V Input
+V Input
-V Output
No Pin
+V Output
On/Off Control
-V Input
+V Input
-V Output
Common
+V Output
www.aimtec.com
F 051e R6.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15EW-Z
15 Watt | DC-DC Converter
Dimensions
5.08
(0.20)
Min
10.16
(0.40)
DIA
1.00
(0.04)
Derating
1
5
4
20.32
(0.80)
10.16
(0.40)
Bottom View
15.24
(0.60)
2.54
(0.10)
2
10.16
(0.40)
3
7.62 5.08
(0.30) (0.20)
25.40
(1.00)
10.16
(0.40)
6
15.24
(0.60)
Built-in Stand-offs to
ease PCB cleaning
2.54
(0.10)
50.80
(2.00)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
Test Circuit
A
Free Air
60 ºC
B
100 LFM
75 ºC
Conducted Emissions:
B
A
Output Power (%)
100
80
60
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages