Series AM1DC-Z 1 Watt | DC-DC Converter FEATURES: RoHS compliant SIP7 package High efficiency up to 79% I/O Isolation 6000 VDC Low coupling capacity Physical clearance of Isolation barrier 2.5mm Safety barrier 100% production tested Rated working voltage of 250 Vrms Continuous Short Circuit protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) *Maximum output ripple & noise (mV p-p) Switching frequency (kHz) AM1DC-0503SH60Z AM1DC-0505SH60Z AM1DC-0509SH60Z AM1DC-0512SH60Z AM1DC-0515SH60Z AM1DC-1203SH60Z AM1DC-1205SH60Z AM1DC-1209SH60Z AM1DC-1212SH60Z AM1DC-1215SH60Z AM1DC-2403SH60Z AM1DC-2405SH60Z AM1DC-2409SH60Z AM1DC-2412SH60Z AM1DC-2415SH60Z 5 5 5 5 5 12 12 12 12 12 24 24 24 24 24 3.3 5 9 12 15 3.3 5 9 12 15 3.3 5 9 12 15 303 200 111 83 67 303 200 111 83 67 303 200 111 83 67 200 200 150 150 150 200 200 150 150 150 150 150 120 150 150 25 24 24 35 36 30 30 30 31 31 43 42 44 43 45 Model Input Voltage (V) Output Voltage (V) Output Current max (mA) *Maximum output ripple & noise (mV p-p) Switching frequency (kHz) AM1DC-0503DH60Z AM1DC-0505DH60Z AM1DC-0509DH60Z AM1DC-0512DH60Z AM1DC-0515DH60Z AM1DC-1203DH60Z AM1DC-1205DH60Z AM1DC-1209DH60Z AM1DC-1212DH60Z AM1DC-1215DH60Z AM1DC-2403DH60Z AM1DC-2405DH60Z AM1DC-2409DH60Z AM1DC-2412DH60Z AM1DC-2415DH60Z 5 5 5 5 5 12 12 12 12 12 24 24 24 24 24 ±3.3 ±5 ±9 ±12 ±15 ±3.3 ±5 ±9 ±12 ±15 ±3.3 ±5 ±9 ±12 ±15 ±152 ±100 ±56 ±42 ±33 ±152 ±100 ±56 ±42 ±33 ±152 ±100 ±56 ±42 ±33 ±120 ±120 ±75 ±75 ±75 ±120 ±120 ±75 ±75 ±75 ±100 ±100 ±75 ±100 ±100 23 23 24 36 35 32 30 31 31 31 43 42 41 43 47 Max Capacitive Load (uF) Efficiency (%) 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 71 75 77 76 77 70 74 76 76 76 70 71 70 72 73 Max Capacitive Load (uF) Efficiency (%) ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 73 75 79 77 77 72 73 75 74 76 72 69 73 72 75 Models Dual output *Output ripple and noise are measured without external connection of filtering capacitors. For reducing these values please refer to the recommended circuit below. www.aimtec.com F 051e R6.E Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1DC-Z 1 Watt | DC-DC Converter Input Specifications Parameters Voltage range Nominal Typical 5 12 24 4.5-5.5 10.8-13.2 21.6-26.4 Filter Maximum Units VDC Capacitor Turn on Transient process time Start up time Absolute Maximum Rating 5 Vin 12 Vin 24 Vin 5 Vin 12 Vin 24 Vin 5 Vin 12 Vin 24 Vin 760 300 280 2.8 2.3 2.24 0-7 0-15 0-28 5 Vin 12 Vin 24 Vin 5 Vin 12 Vin 24 Vin Thru 12µH inductor, 5Hz to 20MHz 30-40 20 10-15 180 200 180 20 Conditions Typical µs ms VDC Peak Input Voltage time Quiescent Current Rise time Input Reflected Ripple current 100 ms mA µs mA rms Isolation Specifications Parameters Tested I/O voltage (rated for 1 min) Rated working voltage Resistance Capacitance Rated Units 6000 VDC V rms MOhm pF Maximum Units Flash tested for 3sec. 250 >1000 10 Output Specifications Parameters Voltage accuracy Voltage balance (Dual output model) Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Maximum Capacitive load Conditions Typical ±3 ±1 Continuous Auto recovery ±1.2 ±10 ±0.03 Balanced Load For 1% change of V in From 10 to 100% load % % % % %/oC Single output models Dual output models 220 ±100 µF Maximum Units General Specifications Parameters Switching frequency Clearance Distance Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Soldering temperature Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Input to Output Full Load without Derating See models table 2.5 -40 to +70 -40 to +125 100 KHz mm o C o C o C Free air convection 95 Non-conductive black plastic, epoxy encapsulated (UL94V-0 rated) 1.5mm from case for 10 sec. 260 4.2 0.77 x 0.39 x 0.47 inches 19.56 x 9.80 x 12.00 mm >2 390 000 hrs (MIL-HDBK-217 F at +25 oC) % RH o C g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R6.E Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1DC-Z 1 Watt | DC-DC Converter Safety Specifications Parameters Standards Designed to meet IEC 60950-1: 2001 Pin Out Specifications Pin 6000 VDC Single + V Input - V Input - V Output No pin + V Output 1 2 5 6 7 Dual + V Input - V Input - V Output Common + V Output Dimensions Derating 19.56 (0.77) Free Air Convection PRINTED FACE 12.50 (0.49) 12.00 (0.47) 0.50 (0.02) 2.54 (0.10) 3.50 (0.14) 15.20 (0.60) 0.50 (0.02) 9.80 (0.39) 0.50 (0.02) Output Power ( % ) 9.80 (0.39) 100 70ºC 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature º C 0.25 (0.01) 2.40 (0.09) Recommended Application circuit for reducing the output ripple and noises: Recommended Output Capacitor to reduce the converter’s ripple and noises for single output models is 4.7µF to 100µF and for dual output models is 4.7µF to 68µF connected to both outputs. Li with value of 12µH and Ci with value 10µF to 100µF are recommended to be connected to the input of the converter for EMI improvement. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R6.E Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only