AIMTEC AM1DR-0507S-RZ 1 watt | dc-dc converter Datasheet

Series AM1DR-RZ
1 Watt | DC-DC Converter
FEATURES:
• Regulated Single Output
• Continuous Short Circuit Protection
• RoHS Compliant
• MTBF>1,500,000 hours
•
•
•
•
1000VDC Isolation
Operating temperature: -40°C to +85°C
Industry Standard Pinout
SIP7 Package
Models
Single output
Model
Input Voltage
(V)
Output
Voltage
(V)
Output Current
max (mA)
Max
Capacitive
Load (uF)
Isolation
(VDC)
Efficiency
(%)
AM1DR-0503S-RZ
4.5-5.5
3.3
303
1000
220
55
AM1DR-0505S-RZ
4.5-5.5
5
200
1000
220
64
AM1DR-0507S-RZ
4.5-5.5
7.2
139
1000
220
64
AM1DR-0509S-RZ
4.5-5.5
9
111
1000
220
65
AM1DR-0512S-RZ
4.5-5.5
12
83
1000
220
66
AM1DR-0515S-RZ
4.5-5.5
15
67
1000
220
66
AM1DR-1203S-RZ
10.8-13.2
3.3
303
1000
220
56
AM1DR-1205S-RZ
10.8-13.2
5
200
1000
220
64
AM1DR-1207S-RZ
10.8-13.2
7.2
139
1000
220
65
AM1DR-1209S-RZ
10.8-13.2
9
111
1000
220
66
AM1DR-1212S-RZ
10.8-13.2
12
83
1000
220
66
AM1DR-1215S-RZ
10.8-13.2
15
67
1000
220
68
AM1DR-2403S-RZ
21.6- 26.4
3.3
303
1000
220
56
AM1DR-2405S-RZ
21.6- 26.4
5
200
1000
220
63
AM1DR-2407S-RZ
21.6- 26.4
7.2
139
1000
220
65
AM1DR-2409S-RZ
21.6- 26.4
9
111
1000
220
66
AM1DR-2412S-RZ
21.6- 26.4
12
83
1000
220
67
AM1DR-2415S-RZ
21.6- 26.4
15
67
1000
220
67
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
5
12
24
Filter
Absolute Maximum Rating (100 ms)
Typical
Maximum
Units
4.5- 5.5
10.8-13.2
21.6- 26.4
Capacitor
VDC
5
12
24
7
15
28
45
No load input current
Input reflected ripple current
VDC
mA
mA p-p
20
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
3 sec
At 500VDC
Rated
Units
1000
VDC
MOhm
pF
>1000
60
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation
www.aimtec.com
F 051e R9.E
Conditions
Typical
±2
Continuous
Auto-Recovery
±0.5
LL ~ HL
Tel: +1 514 620 2722
1 of 3
Maximum
Units
%
% of Vin
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1DR-RZ
1 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Conditions
Load voltage regulation
Load voltage regulation (3.3V output)
Temperature coefficient
Ripple & Noise
Typical
From 0% to 100% Load
From 0% to 100% Load
Maximum
±0.5
±1
±0.02
50
20MHz Bandwidth
Units
%
%
o
%/ C
mV p-p
General Specifications
Parameters
Conditions
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Typical
Maximum
Units
50 (variable)
Full load
KHz
o
C
o
C
o
C
-40 to +85
-40 to +125
100
Free Air Convection
95
Non-Conductive Plastic (UL94V-0)
2.7
19.50 x 7.20 x 9.50 mm (0.77 x 0.28 x 0.37 inches)
o
>1,500,000 hrs dual (MIL-HDBK -217F, Ground Benign, t=+25 C)
1.5mm from case for 10 sec
260
% RH
g
o
C
Safety Specifications
Parameters
Agency Approvals
Safety Standards
CE
EN 55022, Class B
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-6
IEC61000-4-8
Also designed to meet IEC 60950-1
Pin Out Specifications
Pin
1
2
4
5
6
7
Single
+ V input
- V input
- V output
No Pin
+ V output
No Pin
Dimensions
19.50
(0.78)
7.20
(0.28)
PRINTED
FACE
9.50
(0.37)
9.50
(0.37)
0.50
(0.02)
3.05
(0.12)
2.54
(0.10)
0.50
(0.02)
7.20
(0.28)
0.25
(0.01)
0.50
(0.02)
1.25
(0.05)
www.aimtec.com
F 051e R9.E
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1DR-RZ
1 Watt | DC-DC Converter
Radiated and Conducted Emissions Application circuit:
C1
L1
470µF/100V
12 µH
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R9.E
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages