AIMTEC AM1MR-2409SZ 1 watt | dc-dc converter Datasheet

Series AM1MR-Z
1 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Models
Single output
Model
Input Voltage
(V)
Regulated Single Output
Continuous Short Circuit Protection
RoHS Compliant
MTBF>1,500,000 hours
Output
Voltage
(V)
Output Current
max (mA)
•
•
•
•
1000VDC Isolation
Operating temperature: -40°C to +85°C
Industry Standard Pinout
14 Pin DIP Package
Max
Capacitive
Load (uF)
Isolation
(VDC)
Efficiency
(%)
AM1MR-0503SZ
4.5-5.5
3.3
303
1000
220
55
AM1MR-0505SZ
4.5-5.5
5
200
1000
220
64
AM1MR-0507SZ
4.5-5.5
7.2
139
1000
220
64
AM1MR-0509SZ
4.5-5.5
9
111
1000
220
65
AM1MR-0512SZ
4.5-5.5
12
83
1000
220
66
AM1MR-0515SZ
4.5-5.5
15
67
1000
220
66
AM1MR-1203SZ
10.8-13.2
3.3
303
1000
220
56
AM1MR-1205SZ
10.8-13.2
5
200
1000
220
64
AM1MR-1207SZ
10.8-13.2
7.2
139
1000
220
65
AM1MR-1209SZ
10.8-13.2
9
111
1000
220
66
AM1MR-1212SZ
10.8-13.2
12
83
1000
220
66
AM1MR-1215SZ
10.8-13.2
15
67
1000
220
68
AM1MR-2403SZ
21.6- 26.4
3.3
303
1000
220
56
AM1MR-2405SZ
21.6- 26.4
5
200
1000
220
63
AM1MR-2407SZ
21.6- 26.4
7.2
139
1000
220
65
AM1MR-2409SZ
21.6- 26.4
9
111
1000
220
66
AM1MR-2412SZ
21.6- 26.4
12
83
1000
220
67
AM1MR-2415SZ
21.6- 26.4
15
67
1000
220
67
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Absolute Maximum Rating (100 ms)
Input no load current
Input reflected current
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Nominal
5
12
24
5
12
24
Conditions
F 051e R9.E
Maximum
Units
VDC
7
15
28
35
Typical
3 sec
At 500VDC
Parameters
www.aimtec.com
4.5- 5.5
10.8-13.2
21.6- 26.4
Capacitor
VDC
mA
mA
20
Output Specifications
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation
Typical
Rated
>1000
60
Conditions
LL ~ HL
Tel: +1 514 620 2722
1 of 3
Units
1000
Typical
±2
Continuous
Auto-Recovery
±0.5
VDC
MOhm
pF
Maximum
Units
%
% of Vin
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1MR-Z
1 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Load voltage regulation
Load voltage regulation (3.3V output)
Temperature coefficient
Ripple & Noise
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Safety Specifications
20MHz Bandwidth
Conditions
1
7
8
9
10
11
14
Units
%
%
%/oC
mV p-p
Units
KHz
o
C
o
C
o
C
-40 to +85
100
95
% RH
Non-Conductive Plastic (UL94V-0)
2.7
g
20.30 x 10.16 x 6.90 mm (0.80 x 0.40 x 0.27 inches )
>1,500,000hrs dual (MIL-HDBK -217F, Ground Benign, t=+25oC) (too big, may be 1.5M?)
o
1.5mm from case for 10 sec
260
C
CE
EN 55022, Class B
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-6
IEC61000-4-8
Also designed to meet IEC 60950-1
Dimensions
15.24
(0.60)
20.30
(0.80)
1
10.16
(0.40)
Pin
-40 to +125
Maximum
Free Air Convection
Pin Out Specifications
Single
- V input
NC
No Pin
+ V output
No Pin
- V output
+ V input
NC: No Connection
Typical
50 (variable)
Full Load
Maximum
±0.5
±1
±0.02
50
0.25
(0.01)
Agency Approvals
Safety Standards
Typical
7.62
(0.30)
Parameters
Conditions
From 0% to 100% Load
From 0% to 100% Load
0.50
(0.02)
14
11 10
9
8
2.54
(0.10)
3.05
(0.12)
6.90
(0.27)
Printed Face
7
Bottom View
www.aimtec.com
F 051e R9.E
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1MR-Z
1 Watt | DC-DC Converter
Radiated and Conducted Emissions Application circuit:
C1
470µF/100V
L1
12 µH
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R9.E
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages