Series AM1MR-Z 1 Watt | DC-DC Converter FEATURES: • • • • Models Single output Model Input Voltage (V) Regulated Single Output Continuous Short Circuit Protection RoHS Compliant MTBF>1,500,000 hours Output Voltage (V) Output Current max (mA) • • • • 1000VDC Isolation Operating temperature: -40°C to +85°C Industry Standard Pinout 14 Pin DIP Package Max Capacitive Load (uF) Isolation (VDC) Efficiency (%) AM1MR-0503SZ 4.5-5.5 3.3 303 1000 220 55 AM1MR-0505SZ 4.5-5.5 5 200 1000 220 64 AM1MR-0507SZ 4.5-5.5 7.2 139 1000 220 64 AM1MR-0509SZ 4.5-5.5 9 111 1000 220 65 AM1MR-0512SZ 4.5-5.5 12 83 1000 220 66 AM1MR-0515SZ 4.5-5.5 15 67 1000 220 66 AM1MR-1203SZ 10.8-13.2 3.3 303 1000 220 56 AM1MR-1205SZ 10.8-13.2 5 200 1000 220 64 AM1MR-1207SZ 10.8-13.2 7.2 139 1000 220 65 AM1MR-1209SZ 10.8-13.2 9 111 1000 220 66 AM1MR-1212SZ 10.8-13.2 12 83 1000 220 66 AM1MR-1215SZ 10.8-13.2 15 67 1000 220 68 AM1MR-2403SZ 21.6- 26.4 3.3 303 1000 220 56 AM1MR-2405SZ 21.6- 26.4 5 200 1000 220 63 AM1MR-2407SZ 21.6- 26.4 7.2 139 1000 220 65 AM1MR-2409SZ 21.6- 26.4 9 111 1000 220 66 AM1MR-2412SZ 21.6- 26.4 12 83 1000 220 67 AM1MR-2415SZ 21.6- 26.4 15 67 1000 220 67 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Absolute Maximum Rating (100 ms) Input no load current Input reflected current Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Nominal 5 12 24 5 12 24 Conditions F 051e R9.E Maximum Units VDC 7 15 28 35 Typical 3 sec At 500VDC Parameters www.aimtec.com 4.5- 5.5 10.8-13.2 21.6- 26.4 Capacitor VDC mA mA 20 Output Specifications Voltage accuracy Short Circuit protection Short circuit restart Line voltage regulation Typical Rated >1000 60 Conditions LL ~ HL Tel: +1 514 620 2722 1 of 3 Units 1000 Typical ±2 Continuous Auto-Recovery ±0.5 VDC MOhm pF Maximum Units % % of Vin Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1MR-Z 1 Watt | DC-DC Converter Output Specifications (continued) Parameters Load voltage regulation Load voltage regulation (3.3V output) Temperature coefficient Ripple & Noise General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Safety Specifications 20MHz Bandwidth Conditions 1 7 8 9 10 11 14 Units % % %/oC mV p-p Units KHz o C o C o C -40 to +85 100 95 % RH Non-Conductive Plastic (UL94V-0) 2.7 g 20.30 x 10.16 x 6.90 mm (0.80 x 0.40 x 0.27 inches ) >1,500,000hrs dual (MIL-HDBK -217F, Ground Benign, t=+25oC) (too big, may be 1.5M?) o 1.5mm from case for 10 sec 260 C CE EN 55022, Class B IEC61000-4-2 IEC61000-4-3 IEC61000-4-4 IEC61000-4-6 IEC61000-4-8 Also designed to meet IEC 60950-1 Dimensions 15.24 (0.60) 20.30 (0.80) 1 10.16 (0.40) Pin -40 to +125 Maximum Free Air Convection Pin Out Specifications Single - V input NC No Pin + V output No Pin - V output + V input NC: No Connection Typical 50 (variable) Full Load Maximum ±0.5 ±1 ±0.02 50 0.25 (0.01) Agency Approvals Safety Standards Typical 7.62 (0.30) Parameters Conditions From 0% to 100% Load From 0% to 100% Load 0.50 (0.02) 14 11 10 9 8 2.54 (0.10) 3.05 (0.12) 6.90 (0.27) Printed Face 7 Bottom View www.aimtec.com F 051e R9.E Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1MR-Z 1 Watt | DC-DC Converter Radiated and Conducted Emissions Application circuit: C1 470µF/100V L1 12 µH NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R9.E Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only