AIMTEC AM20E-2403SZ 20 watt | dc-dc converter Datasheet

Series AM20E-Z
20 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
Wide 2:1 Input Range
1600 VDC I/O Isolation
Adjustable Output Voltage
Soft Start
Over Current & Over Voltage Protection
•
•
•
•
•
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
5.5
4
1.67
1.33
5.5
4
1.67
1.33
5.5
4
1.67
1.33
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
9-18
9-18
18-36
18-36
36-75
36-75
±12
±15
±12
±15
±12
±15
±0.835
±0.665
±0.835
±0.665
±0.835
±0.665
AM20E-1203SZ
AM20E-1205SZ
AM20E-1212SZ
AM20E-1215SZ
AM20E-2403SZ
AM20E-2405SZ
AM20E-2412SZ
AM20E-2415SZ
AM20E-4803SZ
AM20E-4805SZ
AM20E-4812SZ
AM20E-4815SZ
Models
Dual output
Model
AM20E-1212DZ
AM20E-1215DZ
AM20E-2412DZ
AM20E-2415DZ
AM20E-4812DZ
AM20E-4815DZ
Input Specifications
Parameters
Nominal
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
On/Off Control
Under Voltage Lockout
Input Reflected Ripple Current
www.aimtec.com
F 051e R6.D
12 Vin
24 Vin
48 Vin
Maximum
Capacitive Load
(µF)
Efficiency
(%)
10000
6800
1000
680
10000
6800
1000
680
10000
6800
1000
680
90
92
90
90
91
93
91
91
91
93
91
91
Maximum
Capacitive Load
(µF)
Efficiency
(%)
±470
±330
±470
±330
±470
±330
Typical
9-18
18-36
36-75
20
Maximum
Units
π (Pi) Network
8.6
17.8
33.5
20
Tel: +1 514 620 2722
1 of 5
89
89
90
90
90
89
VDC
ON : 3.0 to 12Vdc or open circuit ;
12 Vin
24 Vin
48 Vin
Efficiency up to 93%
Temperature Range -40ºC to +85ºC
Remote On/Off Function
Continuous Short Circuit Protection
No Minimum Load Required
ms
36
50
VDC
100
100
ms
OFF: 0 to 1.2Vdc or short pin2 and pin 1
OFF: Idle current: 5mA typ
VDC
mA p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20E-Z
20 Watt | DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested voltage Input/Output
Case / Input & Output
Resistance
Capacitance
3 sec
Output Specifications
Parameters
Conditions
Voltage accuracy
Voltage balance (Dual Output Models)
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Ripple & Noise
Voltage adjustment range (single)
Transient Recovery Time
Transient Recovery Deviation
General Specifications
Parameters
Typical
1600
>1000
1200
Typical
±1
±1
Balanced Load
25% load on one output - 100% load on
±5
second load
Zener diode clamp
140% of Full Load
Continuous
Auto-Recovery
HL-LL
±0.2
From 0% load to 100% load
±0.5
Balanced Load
±1
20MHz Bandwidth
75
With 1uF ceramic capacitor
25% load step change ( 75%-50%-25% of Io
25% load step change ( 75%-50%-25% of Io
Conditions
250
±3
Typical
Rated
Units
1600
VDC
VDC
MOhm
pF
Maximum
Units
%
%
%
%
%
%
mV p-p
±10
%
uS
%
Maximum
Units
Switching frequency
100% load
330
KHz
o
Operating temperature
-40 to +85
C
o
Storage temperature
-40 to +125
C
o
Maximum case temperature
100
C
Temperature coefficient
±0.02
%/oC
Derating
Above +70ºC
3.3
%/ºC
Cooling
Free Air Convection
Humidity
95
% RH
Case material
Nickel-coated Copper
Base material
Non-conductive Black Plastic(UL94V-0 rated)
Potting material
Epoxy (UL94V-0 rated)
Weight
30
g
Dimensions (L x W x H)
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.16mm
MTBF
>684,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)
o
Max Soldering temperature
1.5mm from case, 10 sec. max.
260
C
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approvals
Standards
www.aimtec.com
F 051e R6.D
CE
EN55022 Class A (see note A)
EN61000-4-2 Perf. Criteria B
EN61000-4-3 Perf. Criteria A
EN61000-4-4 Perf. Criteria B (see note B)
EN61000-4-5 Perf. Criteria B (see note B)
EN61000-4-6 Perf. Criteria A
EN61000-4-8 Perf. Criteria A
NOTE: also designed to meets IEC/EN 60950-1
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20E-Z
20 Watt | DC-DC Converter
Note A: Input filter components (C1, L , see circuit below) are used to help meet conducted emissions requirement for the module.
These components should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise.
Note B: An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The filter capacitor suggested value of 220uF/100V.
Test Circuits
Conducted Emissions
External parts table
Model
+Vout
L
AM20E-12XXXZ
AM20E-24XXXZ
AM20E-48XXXZ
+Vin
DC/DC
Converter
C1
-Vin
Load
C1
330uF
220uF
220uF
L
12uH
12uH
12uH
-Vout
Pin Out Specifications
6
7.62 5.08
(0.30) (0.20)
25.40
(1.00)
3
2
F 051e R6.D
5
4
20.32
(0.80)
15.24
(0.60)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
5.08
(0.20)
10.16
(0.40)
www.aimtec.com
Bottom View
1
15.24
(0.60)
DIA
1.00
(0.04)
2.54
(0.10)
50.80
(2.00)
10.16
(0.40)
Dimensions
Dual
On/Off Control
- V Input
+ V Input
- V Output
Common
+ V Output
2.54
(0.10)
Single
On/Off Control
- V Input
+ V Input
- V Output
Trim
+ V Output
10.16
(0.40)
1
2
3
4
5
6
10.16
(0.40)
Pin
Pin diameter: 1.0 ±0.05 ( 0.04 ±0.002 )
Pin pitch tolerance: ±0.35 ( ±0.014 )
Case Tolerance: ±0.5 ( ±0.02 )
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20E-Z
20 Watt | DC-DC Converter
Trimming
Output voltage on single output models can be externally trimmed by utilizing the methods as shown below
Fixed Resistor
Variable Potentiometer
Trim Table
AM20E(W)-xx03SZ
AM20E(W)-xx05SZ
AM20E(W)-xx12SZ
AM20E(W)-xx15SZ
www.aimtec.com
F 051e R6.D
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20E-Z
20 Watt | DC-DC Converter
Derating
Free Air Convection
70 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40 - 20
0
20
40
60
80
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.D
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages