AIMTEC AM20EW-4803SZ 20 watt | dc-dc converter Datasheet

Series AM20EW-Z
20 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
RoHS Compliant
Ultra wide 4:1 Input range
Adjustable Output Voltage
Remote On/Off
2” x 1” package
•
•
•
•
Soft start
Industrial temperature range -40 to +85°C
High efficiency up to 91%
No minimum load required
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
3.3
5
12
15
3.3
5
12
15
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±2
±0.835
±0.665
±2
±0.835
±0.665
AM20EW-2403SZ
AM20EW-2405SZ
AM20EW-2412SZ
AM20EW-2415SZ
AM20EW-4803SZ
AM20EW-4805SZ
AM20EW-4812SZ
AM20EW-4815SZ
Output Current
max (A)
5.5
4
1.67
1.33
5.5
4
1.67
1.33
Models
Dual output
Model
AM20EW-2405DZ
AM20EW-2412DZ
AM20EW-2415DZ
AM20EW-4805DZ
AM20EW-4812DZ
AM20EW-4815DZ
Input Specifications
Parameters
Voltage range
Under voltage lockout
Filter
Turn on Transient process time
Transient Recovery deviation
Start up time
Absolute Maximum Rating
Peak Input Voltage time
On/Off Control
OFF idle current
Input Reflected ripple current
www.aimtec.com
F 051e R11.E
Nominal
Typical
24
48
24
48
24
48
Maximum
capacitive load
(µF)
Efficiency
(%)
Maximum
capacitive load
(µF)
Efficiency
(%)
10000
6800
1000
680
10000
6800
1000
680
9-36
18-75
7.9
16
π (Pi) Network
250
20
-0.7~50
-0.7~100
±2200
±470
±330
±2200
±470
±330
Maximum
1 of 5
89
88
89
89
88
89
Units
VDC
8.6
17.8
VDC
±3
µs
%
ms
VDC
100
ON: 3 ~12VDC or open circuit
OFF: 0 ~ 1.2VDC or Short circuit between pin 2 and pin 1
5
20
Tel: +1 514 620 2722
89
91
89
89
89
91
89
89
ms
mA
mA p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20EW-Z
20 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Case/Input Isolation tested voltage
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Cross regulation (Dual output model)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L X W X H)
MTBF
Conditions
Typical
3 sec
3 sec
Rated
1600
>1000
1200
Conditions
Typical
HL-LL
0-100% load
Balanced load
25% load on first output and
100% load on second output
±1
Zener diode clamp
120
Continuous
Auto recovery
±0.5
±0.5
±1
At 20MHz Bandwidth
Conditions
VDC
VDC
MOhm
pF
Maximum
Units
%
% of FL
% of Vin
%
%
±5
%
±0.02
75
±10
%/oC
mV p-p
%
Typical
100% load
With derating above 65°C
Units
1600
330
Maximum
-40 to +85
-40 to +125
Free air convection
105
Units
KHz
o
C
o
C
o
C
95
% RH
Nickel coated copper with non conductive base
30
g
Tolerance ±0.5mm (±0.02 inches)
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.16 mm
>560 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approvals
Standards
www.aimtec.com
F 051e R11.E
CE
EN55022, class A - with external circuit recommended on page 5
EN55024
EN61000-4-2, criteria B
EN61000-4-3, criteria A
EN61000-4-4, criteria B – with external filter capacitor, 220µF/100V
EN61000-4-5, criteria B – with external filter capacitor, 220µF/100V
EN61000-4-6, criteria A
EN61000-4-8, criteria A
NOTE: Designed to meet IEC/EN 60950-1
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20EW-Z
20 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
4
5
6
Single
On/Off Control
-V Input
+V Input
-V Output
Trim
+V Output
Dual
On/Off Control
-V Input
+V Input
-V Output
Common
+V Output
Dimensions
5.08
(0.20)
10.16
(0.40)
1
5
4
20.32
(0.80)
15.24
(0.60)
10.16
(0.40)
Bottom View
2.54
(0.10)
2
10.16
(0.40)
3
7.62 5.08
(0.30) (0.20)
25.40
(1.00)
10.16
(0.40)
6
15.24
(0.60)
DIA
1.00
(0.04)
2.54
(0.10)
50.80
(2.00)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
Pin Diameter: 1.0±0.05mm (0.04±0.002 inches)
Pin pitch tolerance: ±0.35mm (±0.014 inches)
Trimming
www.aimtec.com
F 051e R11.E
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20EW-Z
20 Watt | DC-DC Converter
Trim Table
AM20E(W)-xx03SZ
AM20E(W)-xx05SZ
AM20E(W)-xx12SZ
AM20E(W)-xx15SZ
Derating
Free Air Convection
º
65 C
Output Power (%)
100
80
60
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R11.E
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM20EW-Z
20 Watt | DC-DC Converter
Recommended external circuit to meet the required conducted emissions
Location
Type
Value
C1
1210
2.2µF/100V
C2
1210
2.2µF/100V
L
12µH
These components should be mounted as close as possible to the converter module and length of the leads should be kept
shorter to decrease radiated noise.
Surge/EFT
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.E
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)