BEL 0RCR

ISOLATED DC/DC CONVERTERS
48 VDC Input 8 VDC/15 A Output, 1/8 Brick
0RCR-15T Series
RoHS Compliant
Rev.B
•
Isolated
•
Input Under Voltage Lockout
•
High Efficiency
•
Output Overvoltage Shutdown
•
High Power Density
•
OCP/SCP
•
Fixed Frequency
•
Low Cost
•
Remote On/Off
•
Thermal Shutdown
Description
The 0RCR-15T Series are isolated DC/DC converters that operate from a nominal 48 VDC source. These
converters use a half bridge power train to provide isolation and step down. These units will provide up to 130 W
of output power from a nominal 48 VDC input. These units are designed to be highly efficient and low cost.
Features include remote on/off, over current protection and under voltage lockout. These converters are provided
in an industry standard eighth-brick package.
Part Selection
Output
Voltage
8V
Input
Voltage
36 V-75 V
Max. Output
Current
15 A
Max. Output
Power
130 W
Typical
Efficiency
95%
Model Number
Active High
0RCR-15T08H
Model Number
Active Low
0RCR-15T08L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
Min
-0.3 V
Typ
-
Max
100 V
Remote On/Off
-0.3 V
-
100 V
Ambient Temperature
-40 °C
-
85 °C
Storage Temperature
-40 °C
-
125 °C
Notes
Input Specifications
Parameter
Min
36 V
Typ
-
Max
75 V
Input Current (full load)
-
-
3A
Input Current (no load)
-
-
45 mA
Remote Off Input Current
-
2 mA
3 mA
Input Reflected Ripple Current (pk-pk)
-
-
N/A
Input Reflected Ripple Current (rms)
-
-
Input Voltage
2
Notes
with simulated source impedance of 10
uH, 5 Hz to 20 MHz; use a 47 uF /100
V electrolytic capacitor with ESR = 1
ohm max. at 200 kHz at 25°C.
N/A
2
2
I t Inrush Current Transient
-
0.039 A s
0.062 A s
Turn On Voltage Threshold
-
34.5 V
-
Turn Off Voltage Threshold
-
32.5 V
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 VDC Input 8 VDC/15 A Output, 1/8 Brick
Output Specifications
Parameter
Output Voltage Set Point
Min
Typ
Max
Vin=36 V
Vin=48 V
Vin=75 V
-
6V
8V
12.5 V
6.5 V
-
Vin=36 V
Vin=48 V
Vin=75 V
-
0.5 V
0.5 V
0.5 V
-
-
30mV
-
0A
-
15 A
-
20 A
Short Circuit Surge Transient
-
2
1.3 A s
2.1A s
Ripple and Noise (rms)
-
15 mV
20 mV
Ripple and Noise (pk-pk)
-
90 mV
100 mV
Turn on Time
-
10 mS
-
Overshoot at Turn on
-
0%
3%
0 uF
-
3000 uF
-
100 mV
-
-
120 uS
150 uS
Overshoot
-
100 mV
-
Settling Time
-
120 uS
150 uS
Line Regulation
Notes
Load Regulation
Regulation Over Temperature
(-40 °C to +85 °C)
Output Current
Current Limit Threshold
Output Capacitance
2
Test conditions:
0-20 MHz BW, with a
1 uF ceramic capacitor
and a 15 uF Tantalum
capacitor at the output;
Vin=48 V.
Transient Response
25% ~ 50%
Max Load
50% ~ 25%
Max Load
Overshoot
Settling Time
Vin=48 V
Test conditions: di/dt =
0.1 A/ uS, Vin=48 V,
with a 15 uF tantalum
capacitor at the output.
Note: All specifications are typical at 25 °C unless otherwise stated.
General Specifications
Parameter
Efficiency
Switching Frequency
Over Temperature Protection
Min
Typ
Max
93%
95%
-
180 kHz
200 kHz
220 kHz
-
115 °C
-
MTBF
2,569,594 hours
Notes
Vin=48 V, Io=Iomax
Average PCB temperature will not
exceed 115 °C.
Calculated Per Bell Core SR-332 (IO =
Nominal; Ta = 25 °C)
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Weight
2.30 x 0.896 x 0.403
58.42 x 22.76 x 10.24
-
23 g
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 VDC Input 8 VDC/15 A Output, 1/8 Brick
Control Specifications
Parameter
Remote On/Off
Signal Low (Unit On)
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Active Low
Active High
Min
Typ
Max
-0.3 V
-
0.8 V
2.5 V
-
100 V
-0.3 V
-
0.8 V
2.5 V
-
100 V
Notes
0RCR-15T08L. The remote
on/off pin open, Unit on.
0RCR-15T08H. The remote
on/off pin open, Unit on.
EFFICIENCY
Efficiency Data
96.00%
95.00%
94.00%
93.00%
92.00%
91.00%
90.00%
89.00%
88.00%
87.00%
86.00%
0.00
36V
48V
75V
5.00
10.00
15.00
OUTPUT CURRENT (A)
Thermal Derating Curve
Maximum output power derating curves vs. ambient air temperature
for airflow rates of 0 LFM through 400 LFM with air flowing
from input to output (nominal input voltage).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 VDC Input 8 VDC/15 A Output, 1/8 Brick
Turn-On (Enable)
Transient Response: di/dt=0.1 A/uS, External Load Capacitance Co=15 uF (tantalum capacitor)
50% to 75% and 75% to 50% load Transient at 48 Vdc input and Ta=25 deg C
External Load Capacitance: 15 µF tantalum capacitor
.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 8 Vdc/15 A Output, 1/8 Brick
Mechanical Ouline
Pin Connections
Pin
Function
1
Vin+
2
Remote On/Off
3
Vin-
4
Vout-
5
Vout+
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2008 Bel Fuse Inc. Specifications subject to change without notice. 103108
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com