SPANSION AM29DS320GT70EI 32 megabit (4 m x 8-bit/2 m x 16-bit) cmos 1.8 volt-only, simultaneous operation flash memory Datasheet

Am29DS320G
Data Sheet
-XO\
7KHIROORZLQJGRFXPHQWVSHFLILHV6SDQVLRQPHPRU\SURGXFWVWKDWDUHQRZRIIHUHGE\ERWK$GYDQFHG
0LFUR'HYLFHVDQG)XMLWVX$OWKRXJKWKHGRFXPHQWLVPDUNHGZLWKWKHQDPHRIWKHFRPSDQ\WKDWRULJ
LQDOO\ GHYHORSHG WKHVSHFLILFDWLRQ WKHVH SURGXFWV ZLOO EHRIIHUHG WR FXVWRPHUVRIERWK $0' DQG
)XMLWVX
Continuity of Specifications
7KHUHLVQRFKDQJHWRWKLVGDWDVKHHWDVDUHVXOWRIRIIHULQJWKHGHYLFHDVD6SDQVLRQSURGXFW$Q\
FKDQJHVWKDWKDYHEHHQPDGHDUHWKHUHVXOWRIQRUPDOGDWDVKHHWLPSURYHPHQWDQGDUHQRWHGLQWKH
GRFXPHQWUHYLVLRQVXPPDU\ZKHUHVXSSRUWHG)XWXUHURXWLQHUHYLVLRQVZLOORFFXUZKHQDSSURSULDWH
DQGFKDQJHVZLOOEHQRWHGLQDUHYLVLRQVXPPDU\
Continuity of Ordering Part Numbers
$0'DQG)XMLWVXFRQWLQXHWRVXSSRUWH[LVWLQJSDUWQXPEHUVEHJLQQLQJZLWK³$P´DQG³0%0´7RRUGHU
WKHVHSURGXFWVSOHDVHXVHRQO\WKH2UGHULQJ3DUW1XPEHUVOLVWHGLQWKLVGRFXPHQW
For More Information
3OHDVH FRQWDFW \RXU ORFDO $0' RU )XMLWVX VDOHV RIILFH IRU DGGLWLRQDO LQIRUPDWLRQ DERXW 6SDQVLRQ
PHPRU\VROXWLRQV
Publication Number 26492 Revision A
Amendment +1 Issue Date January 27, 2003
ADVANCE INFORMATION
Am29DS320G
32 Megabit (4 M x 8-Bit/2 M x 16-Bit)
CMOS 1.8 Volt-only, Simultaneous Operation Flash Memory
DISTINCTIVE CHARACTERISTICS
ARCHITECTURAL ADVANTAGES
■ Simultaneous Read/Write operations
— Data can be continuously read from one bank while
executing erase/program functions in another bank
— Zero latency between read and write operations
■ Flexible BankTM architecture
— Read may occur in any of the three banks not being
written or erased.
— Four banks may be grouped by customer to achieve
desired bank divisions.
■ 256-byte SecSi (Secured Silicon) Sector
— Factory locked and identifiable: 16 bytes available for
secure, random factory Electronic Serial Number;
verifiable as factory locked through autoselect
function. ExpressFlash option allows entire sector to
be available for factory-secured data
— Customer lockable: One time programmable. Once
locked, data cannot be changed.
■ Zero Power Operation
— Sophisticated power management circuits reduce
power consumed during inactive periods to nearly
zero
■ Minimum 1 million erase cycles guaranteed per
sector
■ 20 year data retention at 125°C
— Reliable operation for the life of the system
SOFTWARE FEATURES
■ Data Management Software (DMS)
— AMD-supplied software manages data programming,
enabling EEPROM emulation
— Eases historical sector erase flash limitations
■ Supports Common Flash Memory Interface (CFI)
■ Erase Suspend/Erase Resume
— Suspends erase operations to allow reading from
other sectors in the same bank
■ Data# Polling and Toggle Bits
— Provides a software method of detecting the status of
program or erase cycles
■ Unlock Bypass Program command
— Reduces overall programming time when issuing
multiple program command sequences
HARDWARE FEATURES
■ Any combination of sectors can be erased
■ Package options
— 48-ball FBGA
— 48-pin TSOP
■ Top or bottom boot blocks
■ Manufactured on 0.17 µm process technology
■ Compatible with JEDEC standards
— Pinout and software compatible with
single-power-supply flash standard
PERFORMANCE CHARACTERISTICS
■ High performance
— Access time as fast 70 ns
— Program time: 4 µs/word typical utilizing Accelerate
function
■ Ultra low power consumption (typical values)
— 2 mA active read current at 1 MHz
— 10 mA active read current at 5 MHz
— 200 nA in standby or automatic sleep mode
■ Ready/Busy# output (RY/BY#)
— Hardware method for detecting program or erase
cycle completion
■ Hardware reset pin (RESET#)
— Hardware method of resetting the internal state
machine to the read mode
■ WP#/ACC input pin
— Write protect (WP#) function allows protection of two
outermost boot sectors, regardless of sector protect
status
— Acceleration (ACC) function accelerates program
timing
■ Sector protection
— Hardware method of locking a sector, either
in-system or using programming equipment, to
prevent any program or erase operation within that
sector
— Temporary Sector Unprotect allows changing data in
protected sectors in-system
This document contains information on a product under development at Advanced Micro Devices. The information
is intended to help you evaluate this product. AMD reserves the right to change or discontinue work on this proposed
product without notice.
Publication# 26492 Rev: A Amendment:+1
Issue Date: January 27, 2003
Refer to AMD’s Website (www.amd.com) for the latest information.
A D V A N C E
I N F O R M A T I O N
GENERAL DESCRIPTION
The Am29DS320G is a 32 megabit, 1.8 volt-only flash
memory device, organized as 2,097,152 words of 16
bits each or 4,194,304 bytes of 8 bits each. Word
mode data appears on DQ15–DQ0; byte mode data
appears on DQ7–DQ0. The device is designed to be
programmed in-system with the standard 1.8 volt VCC
supply, and can also be programmed in standard
EPROM programmers.
The device is available with an access time of 70, 90,
or 120 ns. The devices are offered in 48-pin TSOP
and 48-ball FBGA packages. Standard control
pins—chip enable (CE#), write enable (WE#), and output enable (OE#)—control normal read and write operations, and avoid bus contention issues.
The device requires only a single 1.8 volt power supply for both read and write functions. Internally generated and regulated voltages are provided for the
program and erase operations.
Simultaneous Read/Write Operations with
Zero Latency
The Simultaneous Read/Write architecture provides
simultaneous operation by dividing the memory
space into four banks, two 4 Mb banks with small and
large sectors, and two 12 Mb banks of large sectors.
Sector addresses are fixed, system software can be
used to form user-defined bank groups.
During an Erase/Program operation, any of the three
non-busy banks may be read from. Note that only two
banks can operate simultaneously. The device allows
a host system to program or erase in one bank, then
immediately and simultaneously read from the other
bank, with zero latency. This releases the system from
waiting for the completion of program or erase
operations.
The Am29DS320G can be organized as either a top or
bottom boot sector configuration.
Bank
Megabits
Bank 1
4 Mb
Bank 2
Bank 3
Bank 4
12 Mb
12 Mb
4 Mb
Sector Sizes
Eight 8 Kbyte/4 Kword,
Seven 64 Kbyte/32 Kword
Twenty-four 64 Kbyte/32 Kword
Twenty-four 64 Kbyte/32 Kword
Eight 64 Kbyte/32 Kword
Am29DS320G Features
The SecSiTM (Secured Silicon) Sector is an 256 byte
extra sector capable of being permanently locked by
AMD or customers. The SecSi Indicator Bit (DQ7) is
permanently set to a 1 if the part is factory locked,
and set to a 0 if customer lockable. This way, customer lockable parts can never be used to replace a
factory locked part. Note that some previous AMD
32 Mbit Am29DS32x devices had a larger SecSi
2
Sector. Factory locked parts provide several options.
The SecSi Sector may store a secure, random 16 byte
ESN (Electronic Serial Number), customer code (programmed through AMD’s ExpressFlash service), or
both.
DMS (Data Management Software) allows systems
to remove EEPROM devices. by simplifying system
software: DMS performs all functions necessary to
modify data in file structures, instead of using single-byte modifications. To write or update a particular
piece of data (a phone number or configuration data,
for example), the user only needs to state which piece
of data is to be updated, and where the updated data
is located in the system. This is an advantage compared to systems where user-written software must
keep track of the old data location, status, logical to
physical translation of the data onto the Flash memory
device (or memory devices), and more. Using DMS,
user-written software does not need to interface with
the Flash memory directly. Instead, the user's software
accesses the Flash memory by calling one of only six
functions. AMD provides this software to simplify system design and software integration efforts.
The device offers complete compatibility with the
JEDEC single-power-supply Flash command set
standard. Commands are written to the command
register using standard microprocessor write timings.
Reading data out of the device is similar to reading
from other Flash or EPROM devices.
The host system can detect whether a program or
erase operation is complete by using the device status bits: RY/BY# pin, DQ7 (Data# Polling) and
DQ6/DQ2 (toggle bits). After a program or erase cycle
has been completed, the device automatically returns
to the read mode.
The sector erase architecture allows memory sectors to be erased and reprogrammed without affecting
the data contents of other sectors. The device is fully
erased when shipped from the factory.
Hardware data protection measures include a low
V CC detector that automatically inhibits write operations during power transitions. The hardware sector
protection feature disables both program and erase
operations in any combination of the sectors of memory. This can be achieved in-system or via programming equipment.
The device offers two power-saving features. When
addresses have been stable for a specified amount of
time, the device enters the automatic sleep mode.
The system can also place the device into the
standby mode. Power consumption is greatly reduced in both modes.
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
TABLE OF CONTENTS
Product Selector Guide . . . . . . . . . . . . . . . . . . . . . 4
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . 5
Special Package Handling Instructions .......................................... 5
Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Logic Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . 7
Device Bus Operations . . . . . . . . . . . . . . . . . . . . . . 8
Table 1. Device Bus Operations .............................................................8
Word/Byte Configuration ................................................................ 8
Requirements for Reading Array Data ...........................................8
Writing Commands/Command Sequences .................................... 9
Accelerated Program Operation .....................................................9
Autoselect Functions ...................................................................... 9
Simultaneous Read/Write Operations
with Zero Latency ...........................................................................9
Standby Mode ................................................................................ 9
Automatic Sleep Mode ...................................................................9
RESET#: Hardware Reset Pin .....................................................10
Output Disable Mode ...................................................................10
Unlock Bypass Command Sequence ........................................... 25
Figure 4. Program Operation ................................................................ 25
Chip Erase Command Sequence ................................................. 25
Sector Erase Command Sequence .............................................. 26
Erase Suspend/Erase Resume Commands ................................ 26
Figure 5. Erase Operation .................................................................... 27
Table 13. Command Definitions ........................................................... 28
Write Operation Status . . . . . . . . . . . . . . . . . . . . 29
DQ7: Data# Polling ...................................................................... 29
Figure 6. Data# Polling Algorithm ......................................................... 29
RY/BY#: Ready/Busy# ................................................................. 30
DQ6: Toggle Bit I .......................................................................... 30
Figure 7. Toggle Bit Algorithm .............................................................. 30
DQ2: Toggle Bit II ......................................................................... 31
Reading Toggle Bits DQ6/DQ2 .................................................... 31
DQ5: Exceeded Timing Limits ...................................................... 31
DQ3: Sector Erase Timer ............................................................. 31
Table 14. Write Operation Status ......................................................... 32
Absolute Maximum Ratings . . . . . . . . . . . . . . . . 33
Figure 8. Maximum Negative Overshoot Waveform ............................. 33
Figure 9. Maximum Positive Overshoot Waveform .............................. 33
Table 2. Top Boot Sector Addresses ...................................................11
Table 3. Top Boot SecSiTM Sector Addresses ..................................... 12
Table 4. Bottom Boot Sector Addresses ...............................................13
Table 5. Bottom Boot SecSiTM Sector Addresses ................................ 14
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 34
Autoselect Mode .......................................................................... 15
Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 6. Autoselect Codes, (High Voltage Method) .............................15
Sector/Sector Block Protection and Unprotection ........................ 16
Table 7. Top Boot Sector/Sector Block Addresses
for Protection/Unprotection ...................................................................16
Table 8. Bottom Boot Sector/Sector Block Addresses
for Protection/Unprotection ...................................................................16
Write Protect (WP#) .....................................................................17
Temporary Sector Unprotect ........................................................ 17
Figure 1. Temporary Sector Unprotect Operation ................................. 17
Figure 2. In-System Sector Protection/
Sector Unprotection Algorithms ............................................................ 18
TM
SecSi (Secured Silicon) Sector
Flash Memory Region .................................................................. 19
Factory Locked: SecSi Sector Programmed and Protected At the
Factory .........................................................................................19
Customer Lockable: SecSi Sector NOT Programmed or Protected At
the Factory ...................................................................................19
Figure 3. SecSi Sector Protect Verify.................................................... 20
Hardware Data Protection ............................................................ 20
Low VCC Write Inhibit .................................................................. 20
Write Pulse “Glitch” Protection .....................................................20
Logical Inhibit ...............................................................................20
Power-Up Write Inhibit .................................................................20
Common Flash Memory Interface (CFI) . . . . . . . 21
Table 9. CFI Query Identification String ................................................
Table 10. System Interface String.........................................................
Table 11. Device Geometry Definition ..................................................
Table 12. Primary Vendor-Specific Extended Query ............................
21
22
22
23
Command Definitions . . . . . . . . . . . . . . . . . . . . . . 23
Reading Array Data ...................................................................... 23
Reset Command .......................................................................... 24
Autoselect Command Sequence .................................................. 24
Enter SecSiTM Sector/Exit SecSi Sector
Command Sequence ...................................................................24
Byte/Word Program Command Sequence ...................................24
January 27, 2003
Figure 10. ICC1 Current vs. Time (Showing Active and
Automatic Sleep Currents).................................................................... 35
Figure 11. Typical ICC1 vs. Frequency................................................... 35
Figure 12. Test Setup .......................................................................... 36
Figure 13. Input Waveforms and Measurement Levels ........................ 36
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 14. Read Operation Timings...................................................... 37
Figure 15. Reset Timings...................................................................... 38
Word/Byte Configuration (BYTE#) ............................................... 39
Figure 16. BYTE# Timings for Read Operations .................................. 39
Figure 17. BYTE# Timings for Write Operations .................................. 39
Erase and Program Operations ................................................... 40
Figure 18. Program Operation Timings ................................................
Figure 19. Accelerated Program Timing Diagram ................................
Figure 20. Chip/Sector Erase Operation Timings .................................
Figure 21. Back-to-back Read/Write Cycle Timings .............................
Figure 22. Data# Polling Timings (During Embedded Algorithms) .......
Figure 23. Toggle Bit Timings (During Embedded Algorithms) ............
Figure 24. DQ2 vs. DQ6 .......................................................................
41
41
42
43
43
44
44
Temporary Sector Unprotect ........................................................ 45
Figure 25. Temporary Sector Unprotect Timing Diagram..................... 45
Figure 26. Sector/Sector Block Protect and Unprotect Timing Diagram 46
Alternate CE# Controlled Erase and Program Operations ........... 47
Figure 27. Alternate CE# Controlled Write (Erase/Program)
Operation Timings ................................................................................ 48
Erase And Programming Performance . . . . . . .
Latchup Characteristics . . . . . . . . . . . . . . . . . . . .
TSOP And SO Pin Capacitance . . . . . . . . . . . . . .
Data Retention. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . .
49
49
49
49
50
FBD048—Fine-Pitch Ball Grid Array, 6 x 12 mm ......................... 50
TS 048—Thin Small Outline Package .......................................... 51
Revision Summary . . . . . . . . . . . . . . . . . . . . . . . . 52
Revision A (May 14, 2002) ........................................................... 52
Revision A+1 (January 3, 2003) ................................................... 52
Am29DS320G
3
A D V A N C E
I N F O R M A T I O N
PRODUCT SELECTOR GUIDE
Part Number
Speed Rating
Am29DS320G
Standard Voltage Range: VCC = 1.8–2.2 V
70
90
120
Max Access Time (ns)
70
90
120
CE# Access (ns)
70
90
120
OE# Access (ns)
30
40
50
BLOCK DIAGRAM
VCC
VSS
OE# BYTE#
Mux
Bank 1
Bank 2
X-Decoder
A20–A0
RESET#
WE#
CE#
BYTE#
WP#/ACC
STATE
CONTROL
&
COMMAND
REGISTER
Status
DQ15–DQ0
Control
Mux
DQ15–DQ0
DQ15–DQ0
Bank 3 Address
Bank 3
X-Decoder
Bank 4 Address
Y-gate
A20–A0
X-Decoder
A20–A0
DQ15–DQ0
Bank 2 Address
DQ15–DQ0
RY/BY#
DQ15–DQ0
A20–A0
X-Decoder
Y-gate
Bank 1 Address
A20–A0
Bank 4
Mux
4
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
CONNECTION DIAGRAMS
A15
A14
A13
A12
A11
A10
A9
A8
A19
A20
WE#
RESET#
NC
WP#/ACC
RY/BY#
A18
A17
A7
A6
A5
A4
A3
A2
A1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
48-Pin Standard TSOP
A16
BYTE#
VSS
DQ15/A-1
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
VCC
DQ11
DQ3
DQ10
DQ2
DQ9
DQ1
DQ8
DQ0
OE#
VSS
CE#
A0
48-Ball FBGA (6 x 12 mm)
Top View, Balls Facing Down
C7
D7
E7
F7
A14
A15
A16
H7
J7
BYTE# DQ15/A-1
K7
VSS
A13
A12
C6
D6
E6
F6
G6
H6
J6
K6
A9
A8
A10
A11
DQ7
DQ14
DQ13
DQ6
C5
D5
E5
F5
G5
H5
J5
K5
WE#
RESET#
NC
A19
DQ5
DQ12
VCC
DQ4
C4
D4
E4
F4
G4
H4
J4
K4
A18
A20
DQ2
DQ10
DQ11
DQ3
RY/BY# WP#/ACC
C3
D3
E3
F3
G3
H3
J3
K3
A7
A17
A6
A5
DQ0
DQ8
DQ9
DQ1
C2
D2
E2
F2
G2
H2
J2
K2
A3
A4
A2
A1
A0
CE#
OE#
VSS
Special Package Handling Instructions
Special handling is required for Flash Memory products
in molded packages (TSOP, BGA, SSOP, PLCC,
PDIP). The package and/or data integrity may be
January 27, 2003
G7
compromised if the package body is exposed to
temperatures above 150°C for prolonged periods of
time.
Am29DS320G
5
A D V A N C E
I N F O R M A T I O N
PIN DESCRIPTION
A20–A0
LOGIC SYMBOL
= 21 Addresses
21
DQ14–DQ0 = 15 Data Inputs/Outputs
A20–A0
DQ15/A-1
= DQ15 (Data Input/Output, word
mode), A-1 (LSB Address Input, byte
mode)
CE#
= Chip Enable
OE#
= Output Enable
WE#
= Write Enable
WP#/ACC
= Hardware Write Protect/
Acceleration Pin
RESET#
RESET#
= Hardware Reset Pin, Active Low
BYTE#
BYTE#
= Selects 8-bit or 16-bit mode
RY/BY#
= Ready/Busy Output
VCC
= 3.0 volt-only single power supply
(see Product Selector Guide for speed
options and voltage supply tolerances)
VSS
= Device Ground
NC
= Pin Not Connected Internally
6
16 or 8
DQ15–DQ0
(A-1)
CE#
OE#
WE#
WP#/ACC
Am29DS320G
RY/BY#
January 27, 2003
A D V A N C E
I N F O R M A T I O N
ORDERING INFORMATION
Standard Products
AMD standard products are available in several packages and operating ranges. The order number (Valid Combination) is
formed by a combination of the following:
Am29DS320G
T
70
E
I
OPTIONAL PROCESSING
Blank = Standard Processing
N
= 16-byte ESN devices
(Contact an AMD representative for more information)
TEMPERATURE RANGE
I
= Industrial (–40°C to +85°C)
E
= Extended (–55°C to +125°C)
PACKAGE TYPE
E
= 48-Pin Thin Small Outline Package
(TSOP) Standard Pinout (TS 048)
WM = 48-Ball Fine-Pitch Ball Grid Array (FBGA)
0.80 mm pitch, 6 x 12 mm package (FBD048)
SPEED OPTION
See Product Selector Guide and Valid Combinations
BOOT CODE SECTOR ARCHITECTURE
T
= Top boot sectors
B
= Bottom boot sectors
DEVICE NUMBER/DESCRIPTION
Am29DS320G
32 Megabit (4 M x 8-Bit/2 M x 16-Bit) CMOS Flash Memory
1.8 Volt-only Read, Program, and Erase
Valid Combinations for TSOP Packages
Valid Combinations for FBGA Packages
AM29DS320GT70,
AM29DS320GB70
AM29DS320GT90,
AM29DS320GB90
Order Number
Package Marking
S320GT70U
S320GB70U
AM29DS320GT70,
AM29DS320GB70
EI, EIN, EE, EEN
AM29DS320GT90,
AM29DS320GB90
AM29DS320GT120,
AM29DS320GB120
AM29DS320GT120,
AM29DS320GB120
Valid Combinations
WMI,
WMIN
S320GT90U
S320GB90U
I
S320GT12U
S320GB12U
Valid Combinations list configurations planned to be supported in
volume for this device. Consult the local AMD sales office to confirm availability of specific valid combinations and to check on
newly released combinations.
January 27, 2003
Am29DS320G
7
A D V A N C E
I N F O R M A T I O N
DEVICE BUS OPERATIONS
This section describes the requirements and use of
the device bus operations, which are initiated through
the internal command register. The command register
itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information
needed to execute the command. The contents of the
Table 1.
register serve as inputs to the internal state machine.
The state machine outputs dictate the function of the
device. Table 1 lists the device bus operations, the inputs and control levels they require, and the resulting
output. The following subsections describe each of
these operations in further detail.
Device Bus Operations
DQ15–DQ8
WP#/ACC
Addresses
(Note 2)
BYTE#
= VIH
BYTE#
= VIL
DQ7–
DQ0
H
L/H
AIN
DOUT
DOUT
L
H
(Note 3)
AIN
DIN
DQ14–DQ8 =
High-Z, DQ15 = A-1
X
X
VCC ±
0.3 V
H
X
High-Z
High-Z
High-Z
L
H
H
H
L/H
X
High-Z
High-Z
High-Z
Reset
X
X
X
L
L/H
X
High-Z
High-Z
High-Z
Sector Protect (Note 2)
L
H
L
VID
L/H
SA, A6 = L,
A1 = H, A0 = L
X
X
DIN
Sector Unprotect (Note 2)
L
H
L
VID
(Note 3)
SA, A6 = H,
A1 = H, A0 = L
X
X
DIN
Temporary Sector
Unprotect
X
X
X
VID
(Note 3)
AIN
DIN
High-Z
DIN
Operation
CE#
OE#
Read
L
L
H
Write
L
H
VCC ±
0.3 V
Output Disable
Standby
WE# RESET#
DIN
Legend: L = Logic Low = VIL, H = Logic High = VIH, VID = 9.0–11.0 V, VHH = 9.0 ± 0.5 V, X = Don’t Care, SA = Sector Address,
AIN = Address In, DIN = Data In, DOUT = Data Out
Notes:
1. Addresses are A20:A0 in word mode (BYTE# = VIH), A20:A-1 in byte mode (BYTE# = VIL).
2. The sector protect and sector unprotect functions may also be implemented via programming equipment. See the “Sector/Sector
Block Protection and Unprotection” section.
3. If WP#/ACC = VIL, the two outermost boot sectors remain protected. If WP#/ACC = VIH, the two outermost boot sector
protection depends on whether they were last protected or unprotected using the method described in “Sector/Sector Block
Protection and Unprotection”. If WP#/ACC = VHH, all sectors will be unprotected.
Word/Byte Configuration
Requirements for Reading Array Data
The BYTE# pin controls whether the device data I/O
pins operate in the byte or word configuration. If the
BYTE# pin is set at logic ‘1’, the device is in word configuration, DQ15–DQ0 are active and controlled by
CE# and OE#.
To read array data from the outputs, the system must
drive the CE# and OE# pins to VIL. CE# is the power
control and selects the device. OE# is the output control and gates array data to the output pins. WE#
should remain at V IH . The BYTE# pin determines
whether the device outputs array data in words or
bytes.
If the BYTE# pin is set at logic ‘0’, the device is in byte
configuration, and only data I/O pins DQ7–DQ0 are
active and controlled by CE# and OE#. The data I/O
pins DQ14–DQ8 are tri-stated, and the DQ15 pin is
used as an input for the LSB (A-1) address function.
8
The internal state machine is set for reading array data
upon device power-up, or after a hardware reset. This
ensures that no spurious alteration of the memory
content occurs during the power transition. No command is necessary in this mode to obtain array data.
Standard microprocessor read cycles that assert valid
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
addresses on the device address inputs produce valid
data on the device data outputs. Each bank remains
enabled for read access until the command register
contents are altered.
See “Requirements for Reading Array Data” for more
information. Refer to the AC Read-Only Operations
table for timing specifications and to Figure 14 for the
timing diagram. ICC1 in the DC Characteristics table
represents the active current specification for reading
array data.
Writing Commands/Command Sequences
To write a command or command sequence (which includes programming data to the device and erasing
sectors of memory), the system must drive WE# and
CE# to VIL, and OE# to VIH.
For program operations, the BYTE# pin determines
whether the device accepts program data in bytes or
words. Refer to “Word/Byte Configuration” for more information.
The device features an Unlock Bypass mode to facilitate faster programming. Once a bank enters the Unlock Bypass mode, only two write cycles are required
to program a word or byte, instead of four. The
“Word/Byte Configuration” section has details on programming data to the device using both standard and
Unlock Bypass command sequences.
An erase operation can erase one sector, multiple sectors, or the entire device. Table 2 indicates the address
space that each sector occupies. The device address
space is divided into two banks: Bank 1 contains the
boot/parameter sectors, and Bank 2 contains the
larger, code sectors of uniform size. A “bank address”
is the address bits required to uniquely select a bank.
Similarly, a “sector address” is the address bits required to uniquely select a sector.
ICC2 in the DC Characteristics table represents the active current specification for the write mode. The AC
Characteristics section contains timing specification
tables and timing diagrams for write operations.
Accelerated Program Operation
The device offers accelerated program operations
through the ACC function. This is one of two functions
provided by the WP#/ACC pin. This function is primarily intended to allow faster manufacturing throughput
at the factory.
If the system asserts VHH on this pin, the device automatically enters the aforementioned Unlock Bypass
mode, temporarily unprotects any protected sectors,
and uses the higher voltage on the pin to reduce the
time required for program operations. The system
would use a two-cycle program command sequence
as required by the Unlock Bypass mode. Removing
January 27, 2003
VHH from the WP#/ACC pin returns the device to normal operation. Note that the WP#/ACC pin must not
be at VHH for operations other than accelerated programming, or device damage may result. In addition,
the WP#/ACC pin must not be left floating or unconnected; inconsistent behavior of the device may result.
Autoselect Functions
If the system writes the autoselect command sequence, the device enters the autoselect mode. The
system can then read autoselect codes from the internal register (which is separate from the memory array)
on DQ7–DQ0. Standard read cycle timings apply in
this mode. Refer to the Autoselect Mode and Autoselect Command Sequence sections for more information.
Simultaneous Read/Write Operations
with Zero Latency
This device is capable of reading data from one bank
of memory while programming or erasing in the other
bank of memory. An erase operation may also be suspended to read from or program to another location
within the same bank (except the sector being
erased). Figure 21 shows how read and write cycles
may be initiated for simultaneous operation with zero
latency. ICC6 and ICC7 in the DC Characteristics table
represent the current specifications for read-while-program and read-while-erase, respectively.
Standby Mode
When the system is not reading or writing to the device, it can place the device in the standby mode. In
this mode, current consumption is greatly reduced,
and the outputs are placed in the high impedance
state, independent of the OE# input.
The device enters the CMOS standby mode when the
CE# and RESET# pins are both held at VCC ± 0.3 V.
(Note that this is a more restricted voltage range than
VIH.) If CE# and RESET# are held at VIH, but not within
VCC ± 0.3 V, the device will be in the standby mode,
but the standby current will be greater. The device requires standard access time (t CE ) for read access
when the device is in either of these standby modes,
before it is ready to read data.
If the device is deselected during erasure or programming, the device draws active current until the
operation is completed.
I CC3 in the DC Characteristics table represents the
standby current specification.
Automatic Sleep Mode
The automatic sleep mode minimizes Flash device energy consumption. The device automatically enables
Am29DS320G
9
A D V A N C E
I N F O R M A T I O N
this mode when addresses remain stable for tACC +
30 ns. The automatic sleep mode is independent of
the CE#, WE#, and OE# control signals. Standard address access timings provide new data when addresses are changed. While in sleep mode, output
data is latched and always available to the system.
I CC5 in the DC Characteristics table represents the
automatic sleep mode current specification.
RESET#: Hardware Reset Pin
The RESET# pin provides a hardware method of resetting the device to reading array data. When the RESET# pin is driven low for at least a period of tRP, the
device immediately terminates any operation in
progress, tristates all output pins, and ignores all
read/write commands for the duration of the RESET#
pulse. The device also resets the internal state machine to reading array data. The operation that was interrupted should be reinitiated once the device is
ready to accept another command sequence, to ensure data integrity.
Current is reduced for the duration of the RESET#
pulse. When RESET# is held at VSS±0.3 V, the device
draws CMOS standby current (ICC4). If RESET# is held
at VIL but not within VSS±0.3 V, the standby current will
be greater.
10
The RESET# pin may be tied to the system reset circuitry. A system reset would thus also reset the Flash
memory, enabling the system to read the boot-up firmware from the Flash memory.
If RESET# is asserted during a program or erase operation, the RY/BY# pin remains a “0” (busy) until the
internal reset operation is complete, which requires a
time of t READY (during Embedded Algorithms). The
system can thus monitor RY/BY# to determine
whether the reset operation is complete. If RESET# is
asserted when a program or erase operation is not executing (RY/BY# pin is “1”), the reset operation is completed within a time of tREADY (not during Embedded
Algorithms). The system can read data tRH after the
RESET# pin returns to VIH.
I CC4 in the DC Characteristics table represents the
reset current. Also refer to AC Characteristics tables
for RESET# timing parameters and to Figure 15 for
the timing diagram.
Output Disable Mode
When the OE# input is at VIH, output from the device is
disabled. The output pins are placed in the high
impedance state.
Am29DS320G
January 27, 2003
A D V A N C E
Bank 2
Bank 3
Bank 4
Table 2.
I N F O R M A T I O N
Top Boot Sector Addresses
Sector
Sector Address
A20–A12
Sector Size
(Kbytes/Kwords)
(x8)
Address Range
SA0
000000xxx
64/32
000000h–00FFFFh
000000h–07FFFh
SA1
000001xxx
64/32
010000h–01FFFFh
008000h–0FFFFh
SA2
000010xxx
64/32
020000h–02FFFFh
010000h–17FFFh
SA3
000011xxx
64/32
030000h–03FFFFh
018000h–01FFFFh
SA4
000100xxx
64/32
040000h–04FFFFh
020000h–027FFFh
SA5
000101xxx
64/32
050000h–05FFFFh
028000h–02FFFFh
SA6
000110xxx
64/32
060000h–06FFFFh
030000h–037FFFh
SA7
000111xxx
64/32
070000h–07FFFFh
038000h–03FFFFh
SA8
001000xxx
64/32
080000h–08FFFFh
040000h–047FFFh
SA9
001001xxx
64/32
090000h–09FFFFh
048000h–04FFFFh
SA10
001010xxx
64/32
0A0000h–0AFFFFh
050000h–057FFFh
SA11
001011xxx
64/32
0B0000h–0BFFFFh
058000h–05FFFFh
SA12
001100xxx
64/32
0C0000h–0CFFFFh
060000h–067FFFh
SA13
001101xxx
64/32
0D0000h–0DFFFFh
068000h–06FFFFh
SA14
001110xxx
64/32
0E0000h–0EFFFFh
070000h–077FFFh
SA15
001111xxx
64/32
0F0000h–0FFFFFh
078000h–07FFFFh
SA16
010000xxx
64/32
100000h–10FFFFh
080000h–087FFFh
SA17
010001xxx
64/32
110000h–11FFFFh
088000h–08FFFFh
SA18
010010xxx
64/32
120000h–12FFFFh
090000h–097FFFh
SA19
010011xxx
64/32
130000h–13FFFFh
098000h–09FFFFh
SA20
010100xxx
64/32
140000h–14FFFFh
0A0000h–0A7FFFh
SA21
010101xxx
64/32
150000h–15FFFFh
0A8000h–0AFFFFh
SA22
010110xxx
64/32
160000h–16FFFFh
0B0000h–0B7FFFh
SA23
010111xxx
64/32
170000h–17FFFFh
0B8000h–0BFFFFh
SA24
011000xxx
64/32
180000h–18FFFFh
0C0000h–0C7FFFh
SA25
011001xxx
64/32
190000h–19FFFFh
0C8000h–0CFFFFh
SA26
011010xxx
64/32
1A0000h–1AFFFFh
0D0000h–0D7FFFh
SA27
011011xxx
64/32
1B0000h–1BFFFFh
0D8000h–0DFFFFh
SA28
011100xxx
64/32
1C0000h–1CFFFFh
0E0000h–0E7FFFh
SA29
011101xxx
64/32
1D0000h–1DFFFFh
0E8000h–0EFFFFh
SA30
011110xxx
64/32
1E0000h–1EFFFFh
0F0000h–0F7FFFh
SA31
011111xxx
64/32
1F0000h–1FFFFFh
0F8000h–0FFFFFh
SA32
100000xxx
64/32
200000h–20FFFFh
100000h–107FFFh
SA33
100001xxx
64/32
210000h–21FFFFh
108000h–10FFFFh
SA34
100010xxx
64/32
220000h–22FFFFh
110000h–117FFFh
SA35
100011xxx
64/32
230000h–23FFFFh
118000h–11FFFFh
SA36
100100xxx
64/32
240000h–24FFFFh
120000h–127FFFh
SA37
100101xxx
64/32
250000h–25FFFFh
128000h–12FFFFh
SA38
100110xxx
64/32
260000h–26FFFFh
130000h–137FFFh
SA39
100111xxx
64/32
270000h–27FFFFh
138000h–13FFFFh
SA40
101000xxx
64/32
280000h–28FFFFh
140000h–147FFFh
SA41
101001xxx
64/32
290000h–29FFFFh
148000h–14FFFFh
SA42
101010xxx
64/32
2A0000h–2AFFFFh
150000h–157FFFh
SA43
101011xxx
64/32
2B0000h–2BFFFFh
158000h–15FFFFh
SA44
101100xxx
64/32
2C0000h–2CFFFFh
160000h–167FFFh
SA45
101101xxx
64/32
2D0000h–2DFFFFh
168000h–16FFFFh
SA46
101110xxx
64/32
2E0000h–2EFFFFh
170000h–177FFFh
SA47
101111xxx
64/32
2F0000h–2FFFFFh
178000h–17FFFFh
January 27, 2003
Am29DS320G
(x16)
Address Range
11
A D V A N C E
Bank 1
Bank 2 (continued)
Table 2.
I N F O R M A T I O N
Top Boot Sector Addresses (Continued)
Sector
Sector Address
A20–A12
Sector Size
(Kbytes/Kwords)
(x8)
Address Range
(x16)
Address Range
SA48
110000xxx
64/32
300000h–30FFFFh
180000h–187FFFh
SA49
110001xxx
64/32
310000h–31FFFFh
188000h–18FFFFh
SA50
110010xxx
64/32
320000h–32FFFFh
190000h–197FFFh
SA51
110011xxx
64/32
330000h–33FFFFh
198000h–19FFFFh
SA52
110100xxx
64/32
340000h–34FFFFh
1A0000h–1A7FFFh
SA53
110101xxx
64/32
350000h–35FFFFh
1A8000h–1AFFFFh
SA54
110110xxx
64/32
360000h–36FFFFh
1B0000h–1B7FFFh
SA55
110111xxx
64/32
370000h–37FFFFh
1B8000h–1BFFFFh
SA56
111000xxx
64/32
380000h–38FFFFh
1C0000h–1C7FFFh
SA57
111001xxx
64/32
390000h–39FFFFh
1C8000h–1CFFFFh
SA58
111010xxx
64/32
3A0000h–3AFFFFh
1D0000h–1D7FFFh
SA59
111011xxx
64/32
3B0000h–3BFFFFh
1D8000h–1DFFFFh
SA60
111100xxx
64/32
3C0000h–3CFFFFh
1E0000h–1E7FFFh
SA61
111101xxx
64/32
3D0000h–3DFFFFh
1E8000h–1EFFFFh
SA62
111110xxx
64/32
3E0000h–3EFFFFh
1F0000h–1F7FFFh
SA63
111111000
8/4
3F0000h–3F1FFFh
1F8000h–1F8FFFh
SA64
111111001
8/4
3F2000h–3F3FFFh
1F9000h–1F9FFFh
SA65
111111010
8/4
3F4000h–3F5FFFh
1FA000h–1FAFFFh
SA66
111111011
8/4
3F6000h–3F7FFFh
1FB000h–1FBFFFh
SA67
111111100
8/4
3F8000h–3F9FFFh
1FC000h–1FCFFFh
SA68
111111101
8/4
3FA000h–3FBFFFh
1FD000h–1FDFFFh
SA69
111111110
8/4
3FC000h–3FDFFFh
1FE000h–1FEFFFh
SA70
111111111
8/4
3FE000h–3FFFFFh
1FF000h–1FFFFFh
Note: The address range is A20:A-1 in byte mode (BYTE#=VIL) or A20:A0 in word mode (BYTE#=VIH). The bank address bits are A20–A18.
Table 3.
12
Top Boot SecSiTM Sector Addresses
Device
Sector Address
A20–A12
Sector Size
(Bytes/Words)
(x8)
Address Range
(x16)
Address Range
Am29DS320GT
111111xxx
256/128
3FE000h–3FE0FFh
1FF000h–1FF07Fh
Am29DS320G
January 27, 2003
A D V A N C E
Bank 3
Bank 2
Bank 1
Table 4.
I N F O R M A T I O N
Bottom Boot Sector Addresses
Sector
Sector Address
A20–A12
Sector Size
(Kbytes/Kwords)
(x8)
Address Range
(x16)
Address Range
SA0
000000000
8/4
000000h–001FFFh
000000h–000FFFh
SA1
000000001
8/4
002000h–003FFFh
001000h–001FFFh
SA2
000000010
8/4
004000h–005FFFh
002000h–002FFFh
SA3
000000011
8/4
006000h–007FFFh
003000h–003FFFh
SA4
000000100
8/4
008000h–009FFFh
004000h–004FFFh
SA5
000000101
8/4
00A000h–00BFFFh
005000h–005FFFh
SA6
000000110
8/4
00C000h–00DFFFh
006000h–006FFFh
SA7
000000111
8/4
00E000h–00FFFFh
007000h–007FFFh
SA8
000001xxx
64/32
010000h–01FFFFh
008000h–00FFFFh
SA9
000010xxx
64/32
020000h–02FFFFh
010000h–017FFFh
SA10
000011xxx
64/32
030000h–03FFFFh
018000h–01FFFFh
SA11
000100xxx
64/32
040000h–04FFFFh
020000h–027FFFh
SA12
000101xxx
64/32
050000h–05FFFFh
028000h–02FFFFh
SA13
000110xxx
64/32
060000h–06FFFFh
030000h–037FFFh
SA14
000111xxx
64/32
070000h–07FFFFh
038000h–03FFFFh
SA15
001000xxx
64/32
080000h–08FFFFh
040000h–047FFFh
SA16
001001xxx
64/32
090000h–09FFFFh
048000h–04FFFFh
SA17
001010xxx
64/32
0A0000h–0AFFFFh
050000h–057FFFh
SA18
001011xxx
64/32
0B0000h–0BFFFFh
058000h–05FFFFh
SA19
001100xxx
64/32
0C0000h–0CFFFFh
060000h–067FFFh
SA20
001101xxx
64/32
0D0000h–0DFFFFh
068000h–06FFFFh
SA21
001110xxx
64/32
0E0000h–0EFFFFh
070000h–077FFFh
SA22
001111xxx
64/32
0F0000h–0FFFFFh
078000h–07FFFFh
SA23
010000xxx
64/32
100000h–10FFFFh
080000h–087FFFh
SA24
010001xxx
64/32
110000h–11FFFFh
088000h–08FFFFh
SA25
010010xxx
64/32
120000h–12FFFFh
090000h–097FFFh
SA26
010011xxx
64/32
130000h–13FFFFh
098000h–09FFFFh
SA27
010100xxx
64/32
140000h–14FFFFh
0A0000h–0A7FFFh
SA28
010101xxx
64/32
150000h–15FFFFh
0A8000h–0AFFFFh
SA29
010110xxx
64/32
160000h–16FFFFh
0B0000h–0B7FFFh
SA30
010111xxx
64/32
170000h–17FFFFh
0B8000h–0BFFFFh
SA31
011000xxx
64/32
180000h–18FFFFh
0C0000h–0C7FFFh
SA32
011001xxx
64/32
190000h–19FFFFh
0C8000h–0CFFFFh
SA33
011010xxx
64/32
1A0000h–1AFFFFh
0D0000h–0D7FFFh
SA34
011011xxx
64/32
1B0000h–1BFFFFh
0D8000h–0DFFFFh
SA35
011100xxx
64/32
1C0000h–1CFFFFh
0E0000h–0E7FFFh
SA36
011101xxx
64/32
1D0000h–1DFFFFh
0E8000h–0EFFFFh
SA37
011110xxx
64/32
1E0000h–1EFFFFh
0F0000h–0F7FFFh
SA38
011111xxx
64/32
1F0000h–1FFFFFh
SA39
100000xxx
64/32
200000h–20FFFFh
0F8000h–0FFFFFh
100000h–107FFFh
SA40
100001xxx
64/32
210000h–21FFFFh
108000h–10FFFFh
SA41
100010xxx
64/32
220000h–22FFFFh
110000h–117FFFh
SA42
100011xxx
64/32
230000h–23FFFFh
118000h–11FFFFh
SA43
100100xxx
64/32
240000h–24FFFFh
120000h–127FFFh
SA44
100101xxx
64/32
250000h–25FFFFh
128000h–12FFFFh
SA45
100110xxx
64/32
260000h–26FFFFh
130000h–137FFFh
SA46
100111xxx
64/32
270000h–27FFFFh
138000h–13FFFFh
SA47
101000xxx
64/32
280000h–28FFFFh
140000h–147FFFh
January 27, 2003
Am29DS320G
13
A D V A N C E
Bank 4
Bank 3 (continued)
Table 4.
I N F O R M A T I O N
Bottom Boot Sector Addresses (Continued)
Sector
Sector Address
A20–A12
Sector Size
(Kbytes/Kwords)
(x8)
Address Range
(x16)
Address Range
SA48
101001xxx
SA49
101010xxx
64/32
290000h–29FFFFh
148000h–14FFFFh
64/32
2A0000h–2AFFFFh
SA50
150000h–157FFFh
101011xxx
64/32
2B0000h–2BFFFFh
158000h–15FFFFh
SA51
101100xxx
64/32
2C0000h–2CFFFFh
160000h–167FFFh
SA52
101101xxx
64/32
2D0000h–2DFFFFh
168000h–16FFFFh
SA53
101110xxx
64/32
2E0000h–2EFFFFh
170000h–177FFFh
SA54
101111xxx
64/32
2F0000h–2FFFFFh
178000h–17FFFFh
SA55
111000xxx
64/32
300000h–30FFFFh
180000h–187FFFh
SA56
110001xxx
64/32
310000h–31FFFFh
188000h–18FFFFh
SA57
110010xxx
64/32
320000h–32FFFFh
190000h–197FFFh
SA58
110011xxx
64/32
330000h–33FFFFh
198000h–19FFFFh
SA59
110100xxx
64/32
340000h–34FFFFh
1A0000h–1A7FFFh
SA60
110101xxx
64/32
350000h–35FFFFh
1A8000h–1AFFFFh
SA61
110110xxx
64/32
360000h–36FFFFh
1B0000h–1B7FFFh
SA62
110111xxx
64/32
370000h–37FFFFh
1B8000h–1BFFFFh
SA63
111000xxx
64/32
380000h–38FFFFh
1C0000h–1C7FFFh
SA64
111001xxx
64/32
390000h–39FFFFh
1C8000h–1CFFFFh
SA65
111010xxx
64/32
3A0000h–3AFFFFh
1D0000h–1D7FFFh
SA66
111011xxx
64/32
3B0000h–3BFFFFh
1D8000h–1DFFFFh
SA67
111100xxx
64/32
3C0000h–3CFFFFh
1E0000h–1E7FFFh
SA68
111101xxx
64/32
3D0000h–3DFFFFh
1E8000h–1EFFFFh
SA69
111110xxx
64/32
3E0000h–3EFFFFh
1F0000h–1F7FFFh
SA70
111111xxx
64/32
3F0000h–3FFFFFh
1F8000h–1FFFFFh
Note: The address range is A20:A-1 in byte mode (BYTE#=VIL) or A20:A0 in word mode (BYTE#=VIH). The bank address bits
are A20–A18.
Table 5.
14
Bottom Boot SecSiTM Sector Addresses
Device
Sector Address
A20–A12
Sector Size
(Bytes/Words)
(x8)
Address Range
(x16)
Address Range
Am29DS320GB
000000xxx
256/128
000000h–0000FFh
00000h–00007Fh
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
Autoselect Mode
tion, when verifying sector protection, the sector address must appear on the appropriate highest order
address bits (see Table 2). Table 6 shows the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming
equipment may then read the corresponding identifier
code on DQ7–DQ0.
The autoselect mode provides manufacturer and device identification, and sector protection verification,
through identifier codes output on DQ7–DQ0. This
mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programm ing
algorithm. However, the autoselect codes can also be
accessed in-system through the command register.
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in Table 13. This method
does not require V ID . Refer to the Autoselect Command Sequence section for more information.
When using programming equipment, the autoselect
mode requires VID on address pin A9. Address pins
A6, A1, and A0 must be as shown in Table 6. In addi-
Table 6.
Description
Manufacturer ID:
AMD
CE# OE# WE#
Autoselect Codes, (High Voltage Method)
A20
to
A12
A11
to
A10
A9
A8
to
A7
DQ15 to DQ8
A6
A5
to
A4
A3
A2
A1
A0
BYTE# BYTE#
= VIH
= VIL
DQ7
to
DQ0
L
H
BA
X
VID
X
L
X
X
X
L
L
X
X
01h
Read Cycle 1
L
L
H
BA
X
VID
X
L
X
L
L
L
H
22h
X
7Eh
Read Cycle 2
L
L
H
BA
X
VID
X
L
X
H
H
H
L
22h
X
0Bh
Read Cycle 3
L
L
H
BA
X
VID
X
L
X
H
H
H
H
22h
X
01h (T), 00h (B)
Sector Protection
Verification
L
L
H
SA
X
VID
X
L
X
X
X
H
L
X
X
01h (protected),
00h (unprotected)
SecSi Indicator
Bit (DQ7)
L
L
H
BA
X
VID
X
L
X
X
X
H
H
X
X
81h (factory locked),
01h (not factory
locked)
Device ID
L
Legend: T = Top Boot Block, B = Bottom Boot Block, L = Logic Low = VIL, H = Logic High = VIH, BA = Bank Address, SA = Sector Address, X
= Don’t care.
Notes:
1.
The bank address bits are A20–A18.
2.
The device ID must be read across three cycles.
January 27, 2003
Am29DS320G
15
A D V A N C E
I N F O R M A T I O N
Sector/Sector Block Protection and
Unprotection
Table 8. Bottom Boot Sector/Sector Block
Addresses for Protection/Unprotection
(Note: For the following discussion, the term “sector”
applies to both sectors and sector blocks. A sector
block consists of two or more adjacent sectors that are
protected or unprotected at the same time (see Tables
2 and 4).
The hardware sector protection feature disables both
program and erase operations in any sector. The hardware sector unprotection feature re-enables both program and erase operations in previously protected
sectors. Sector protection/unprotection can be implemented via two methods.
Table 7.
Top Boot Sector/Sector Block Addresses
for Protection/Unprotection
Sector
A20–A12
Sector/
Sector Block Size
SA0
000000XXX
64 Kbytes
A20–A12
Sector/Sector Block
Size
SA70
111111XXX
64 Kbytes
SA69-SA67
111110XXX,
111101XXX,
111100XXX
192 (3x64) Kbytes
SA66-SA63
1110XXXXX
256 (4x64) Kbytes
SA62-SA59
1101XXXXX
256 (4x64) Kbytes
SA58-SA55
1100XXXXX
256 (4x64) Kbytes
SA54-SA51
1011XXXXX
256 (4x64) Kbytes
SA50-SA47
1010XXXXX
256 (4x64) Kbytes
SA46-SA43
1001XXXXX
256 (4x64) Kbytes
SA42-SA39
1000XXXXX
256 (4x64) Kbytes
SA38-SA35
0111XXXXX
256 (4x64) Kbytes
SA34-SA31
0110XXXXX
256 (4x64) Kbytes
SA30-SA27
0101XXXXX
256 (4x64) Kbytes
SA26-SA23
0100XXXXX
256 (4x64) Kbytes
SA22–SA19
0011XXXXX
256 (4x64) Kbytes
SA18-SA15
0010XXXXX
256 (4x64) Kbytes
SA14-SA11
0001XXXXX
256 (4x64) Kbytes
SA10-SA8
000011XXX,
000010XXX,
000001XXX
192 (3x64) Kbytes
000001XXX,
000010XXX
000011XXX
192 (3x64) Kbytes
SA4-SA7
0001XXXXX
256 (4x64) Kbytes
SA8-SA11
0010XXXXX
256 (4x64) Kbytes
SA12-SA15
0011XXXXX
256 (4x64) Kbytes
SA16-SA19
0100XXXXX
256 (4x64) Kbytes
SA7
000000111
8 Kbytes
000000110
8 Kbytes
SA1-SA3
16
Sector
SA20-SA23
0101XXXXX
256 (4x64) Kbytes
SA6
SA24-SA27
0110XXXXX
256 (4x64) Kbytes
SA5
000000101
8 Kbytes
SA28-SA31
0111XXXXX
256 (4x64) Kbytes
SA4
000000100
8 Kbytes
000000011
8 Kbytes
SA32-SA35
1000XXXXX
256 (4x64) Kbytes
SA3
SA36-SA39
1001XXXXX
256 (4x64) Kbytes
SA2
000000010
8 Kbytes
000000001
8 Kbytes
000000000
8 Kbytes
SA40-SA43
1010XXXXX
256 (4x64) Kbytes
SA1
SA0
SA44-SA47
1011XXXXX
256 (4x64) Kbytes
SA48-SA51
1100XXXXX
256 (4x64) Kbytes
SA52-SA55
1101XXXXX
256 (4x64) Kbytes
SA56-SA59
1110XXXXX
256 (4x64) Kbytes
SA60-SA62
111100XXX,
111101XXX,
111110XXX
192 (3x64) Kbytes
SA63
111111000
8 Kbytes
SA64
111111001
8 Kbytes
SA65
111111010
8 Kbytes
SA66
111111011
8 Kbytes
SA67
111111100
8 Kbytes
SA68
111111101
8 Kbytes
SA69
111111110
8 Kbytes
SA70
111111111
8 Kbytes
Sector protection/unprotection requires VID on the RESET# pin only, and can be implemented either in-system or via programming equipment. Figure 2 shows
the algorithms and Figure 26 shows the timing diagram. For sector unprotect, all unprotected sectors
must first be protected prior to the first sector unprotect write cycle.
The sector unprotect algorithm unprotects all sectors
in parallel. All previously protected sectors must be individually re-protected. To change data in protected
sectors efficiently, the temporary sector unprotect
function is available. See “Temporary Sector Unprotect”.
The device is shipped with all sectors unprotected.
AMD offers the option of programming and protecting
sectors at its factory prior to shipping the device
through AMD’s ExpressFlash™ Service. Contact an
AMD representative for details.
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
It is possible to determine whether a sector is protected or unprotected. See the Autoselect Mode section for details.
Write Protect (WP#)
The Write Protect function provides a hardware
method of protecting certain boot sectors without
using VID. This function is one of two provided by the
WP#/ACC pin.
If the system asserts VIL on the WP#/ACC pin, the device disables program and erase functions in the two
“outermost” 8 Kbyte boot sectors independently of
whether those sectors were protected or unprotected
using the method described in “Sector/Sector Block
Protection and Unprotection”. The two outermost 8
Kbyte boot sectors are the two sectors containing the
lowest addresses in a bottom-boot-configured device,
or the two sectors containing the highest addresses in
a top-boot-configured device.
Temporary Sector Unprotect
(Note: For the following discussion, the term “sector”
applies to both sectors and sector blocks. A sector
block consists of two or more adjacent sectors that are
protected or unprotected at the same time (Tables 2
and 4).
This feature allows temporary unprotection of previously protected sectors to change data in-system. The
Sector Unprotect mode is activated by setting the RESET# pin to VID. During this mode, formerly protected
sectors can be programmed or erased by selecting the
sector addresses. Once VID is removed from the RESET# pin, all the previously protected sectors are
protected again. Figure 1 shows the algorithm, and
Figure 25 shows the timing diagrams, for this feature.
START
If the system asserts VIH on the WP#/ACC pin, the device reverts to whether the two outermost 8K Byte
boot sectors were last set to be protected or unprotected. That is, sector protection or unprotection for
these two sectors depends on whether they were last
protected or unprotected using the method described
in “Sector/Sector Block Protection and Unprotection”.
RESET# = VID
(Note 1)
Perform Erase or
Program Operations
Note that the WP#/ACC pin must not be left floating or
unconnected; inconsistent behavior of the device may
result.
RESET# = VIH
Temporary Sector
Unprotect Completed
(Note 2)
Notes:
1. All protected sectors unprotected (If WP#/ACC = VIL,
outermost boot sectors will remain protected).
2. All previously protected sectors are protected once
again.
Figure 1.
January 27, 2003
Am29DS320G
Temporary Sector Unprotect Operation
17
A D V A N C E
I N F O R M A T I O N
START
START
Protect all sectors:
The indicated portion
of the sector protect
algorithm must be
performed for all
unprotected sectors
prior to issuing the
first sector
unprotect address
PLSCNT = 1
RESET# = VID
Wait 1 µs
Temporary Sector
Unprotect Mode
No
PLSCNT = 1
RESET# = VID
Wait 1 µs
No
First Write
Cycle = 60h?
First Write
Cycle = 60h?
Yes
Yes
Set up sector
address
No
Sector Protect:
Write 60h to sector
address with
A6 = 0, A1 = 1,
A0 = 0
All sectors
protected?
Yes
Set up first sector
address
Sector Unprotect:
Write 60h to any
address with
A6 = 1, A1 = 1,
A0 = 0
Wait 150 µs
Increment
PLSCNT
Temporary Sector
Unprotect Mode
Verify Sector
Protect: Write 40h
to sector address
with A6 = 0,
A1 = 1, A0 = 0
Reset
PLSCNT = 1
Read from
sector address
with A6 = 0,
A1 = 1, A0 = 0
Wait 15 ms
Verify Sector
Unprotect: Write
40h to sector
address with
A6 = 1, A1 = 1,
A0 = 0
Increment
PLSCNT
No
No
PLSCNT
= 25?
Yes
Yes
No
Yes
Device failed
PLSCNT
= 1000?
Protect another
sector?
No
Yes
Remove VID
from RESET#
Device failed
Write reset
command
Sector Protect
Algorithm
Read from
sector address
with A6 = 1,
A1 = 1, A0 = 0
Data = 01h?
Sector Protect
complete
Set up
next sector
address
No
Data = 00h?
Yes
Last sector
verified?
No
Yes
Sector Unprotect
Algorithm
Remove VID
from RESET#
Write reset
command
Sector Unprotect
complete
Figure 2. In-System Sector Protection/
Sector Unprotection Algorithms
18
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
SecSiTM (Secured Silicon) Sector
Flash Memory Region
The SecSi (Secured Silicon) Sector feature provides a
256-byte Flash memory region that enables permanent part identification through an Electronic Serial
Number (ESN). The SecSi Sector uses a SecSi Sector
Indicator Bit (DQ7) to indicate whether or not the
SecSi Sector is locked when shipped from the factory.
This bit is permanently set at the factory and cannot
be changed, which prevents cloning of a factory
locked part. This ensures the security of the ESN once
the product is shipped to the field.
AMD offers the device with the SecSi Sector either
factor y locked o r custom er locka ble . Th e factory-locked version is always protected when shipped
from the factory, and has the SecSi (Secured Silicon)
Sector Indicator Bit permanently set to a “1.” The customer-lockable version is shipped with the SecSi Sector unprotected, allowing customers to utilize the that
sector in any manner they choose. The customer-lockable version has the SecSi (Secured Silicon) Sector
Indicator Bit permanently set to a “0.” Thus, the SecSi
Sector Indicator Bit prevents customer-lockable devices from being used to replace devices that are factory locked.
The system accesses the SecSi Sector through a
command sequence (see “Enter SecSiTM Sector/Exit
SecSi Sector Command Sequence”). After the system
has written the Enter SecSi Sector command sequence, it may read the SecSi Sector by using the addresses normally occupied by the boot sectors. This
mode of operation continues until the system issues
the Exit SecSi Sector command sequence, or until
power is removed from the device. On power-up, or
following a hardware reset, the device reverts to sending commands to the boot sectors. Note that the ACC
function and unlock bypass modes are not available
when the SecSi Sector is enabled.
Factory Locked: SecSi Sector Programmed and
Protected At the Factory
In a factory locked device, the SecSi Sector is protected when the device is shipped from the factory.
The SecSi Sector cannot be modified in any way. The
device is available preprogrammed with one of the following:
■ A random, secure ESN only
■ Customer code through the ExpressFlash service
■ Both a random, secure ESN and customer code
through the ExpressFlash service.
January 27, 2003
In devices that have an ESN, a Bottom Boot device
will have the 16-byte ESN at addresses
000000h–000007h
in
word
mode
(or
000000h–00000Fh in byte mode). In the Top Boot device the ESN will be at addresses
1FF000h–1FF007Fh in word mode (or addresses
3FE000h–3FE0FFh in byte mode).
Customers may opt to have their code programmed by
AMD through the AMD ExpressFlash service. AMD
programs the customer’s code, with or without the random ESN. The devices are then shipped from AMD’s
factory with the SecSi Sector permanently locked.
Contact an AMD representative for details on using
AMD’s ExpressFlash service.
Customer Lockable: SecSi Sector NOT
Programmed or Protected At the Factory
If the security feature is not required, the SecSi Sector
can be treated as an additional 256-byte Flash memory space, expanding the size of the available Flash
array. Additionally, note the difference in the location of the ESN compared to previous Am29DS32x
top boot factory locked devices. The SecSi Sector
is one-time programmable, may not be erased, and
can be locked only once. Note that the accelerated
programming (ACC) and unlock bypass functions are
not available when programming the SecSi Sector.
The SecSi Sector area can be protected using one of
the following procedures:
■ Write the three-cycle Enter SecSi Sector Region
command sequence, and then follow the in-system
sector protect algorithm as shown in Figure 2, except that RESET# may be at either VIH or VID. This
allows in-system protection of the SecSi Sector
without raising any device pin to a high voltage.
Note that this method is only applicable to the SecSi
Sector
■ To verify the protect/unprotect status of the SecSi
Sector, follow the algorithm shown in Figure 3.
The SecSi Sector is one-time programmable. Once
the SecSi Sector is locked and verified, the system
must write the Exit SecSi Sector Region command sequence to return to reading and writing the remainder
of the array.
The SecSi Sector protection must be used with caution since, once protected, there is no procedure available for unprotecting the SecSi Sector area and none
of the bits in the SecSi Sector memory space can be
modified in any way.
Am29DS320G
19
A D V A N C E
I N F O R M A T I O N
data protection measures prevent accidental erasure
or programming, which might otherwise be caused by
spurious system level signals during V CC power-up
and power-down transitions, or from system noise.
START
RESET# =
VIH or VID
Wait 1 µs
Write 60h to
any address
Write 40h to SecSi
Sector address
with A6 = 0,
A1 = 1, A0 = 0
Read from SecSi
Sector address
with A6 = 0,
A1 = 1, A0 = 0
Low VCC Write Inhibit
If data = 00h,
SecSi Sector is
unprotected.
If data = 01h,
SecSi Sector is
protected.
When VCC is less than V LKO, the device does not accept any write cycles. This protects data during VCC
power-up and power-down. The command register
and all internal program/erase circuits are disabled,
and the device resets to the read mode. Subsequent
writes are ignored until VCC is greater than VLKO. The
system must provide the proper signals to the control
pins to prevent unintentional writes when V CC is
greater than VLKO.
Remove VIH or VID
from RESET#
Write reset
command
Write Pulse “Glitch” Protection
Noise pulses of less than 5 ns (typical) on OE#, CE#
or WE# do not initiate a write cycle.
SecSi Sector
Protect Verify
complete
Logical Inhibit
Write cycles are inhibited by holding any one of OE# =
VIL, CE# = VIH or WE# = V IH. To initiate a write cycle,
CE# and WE# must be a logical zero while OE# is a
logical one.
Figure 3.
SecSi Sector Protect Verify
Power-Up Write Inhibit
Hardware Data Protection
The command sequence requirement of unlock cycles
for programming or erasing provides data protection
against inadvertent writes (refer to Table 13 for command definitions). In addition, the following hardware
20
If WE# = CE# = VIL and OE# = VIH during power up,
the device does not accept commands on the rising
edge of WE#. The internal state machine is automatically reset to the read mode on power-up.
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
COMMON FLASH MEMORY INTERFACE
(CFI)
The Common Flash Interface (CFI) specification outlines device and host system software interrogation
handshake, which allows specific vendor-specified
software algorithms to be used for entire families of
devices. Software support can then be device-independent, JEDEC ID-independent, and forward- and
backward-compatible for the specified flash device
families. Flash vendors can standardize their existing
interfaces for long-term compatibility.
This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to address
55h in word mode (or address AAh in byte mode), any
time the device is ready to read array data. The
system can read CFI information at the addresses
Table 9.
given in Tables 9–12. To terminate reading CFI data,
the system must write the reset command. The CFI
Query mode is not accessible when the device is executing an Embedded Program or Embedded Erase algorithm.
The system can also write the CFI query command
when the device is in the autoselect mode. The device
enters the CFI query mode, and the system can read
CFI data at the addresses given in Tables 9–12. The
system must write the reset command to return the device to reading array data.
For further information, please refer to the CFI Specification and CFI Publication 100, available via the
World Wide Web at http://www.amd.com/flash/cfi. Alternatively, contact an AMD representative for copies
of these documents.
CFI Query Identification String
Addresses
(Word Mode)
Addresses
(Byte Mode)
Data
10h
11h
12h
20h
22h
24h
0051h
0052h
0059h
Query Unique ASCII string “QRY”
13h
14h
26h
28h
0002h
0000h
Primary OEM Command Set
15h
16h
2Ah
2Ch
0040h
0000h
Address for Primary Extended Table
17h
18h
2Eh
30h
0000h
0000h
Alternate OEM Command Set (00h = none exists)
19h
1Ah
32h
34h
0000h
0000h
Address for Alternate OEM Extended Table (00h = none exists)
January 27, 2003
Description
Am29DS320G
21
A D V A N C E
Table 10.
I N F O R M A T I O N
System Interface String
Addresses
(Word Mode)
Addresses
(Byte Mode)
Data
1Bh
36h
0018h
VCC Min. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Ch
38h
0022h
VCC Max. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Dh
3Ah
0000h
VPP Min. voltage (00h = no VPP pin present)
1Eh
3Ch
0000h
VPP Max. voltage (00h = no VPP pin present)
1Fh
3Eh
0003h
Typical timeout per single byte/word write 2N µs
20h
40h
0000h
Typical timeout for Min. size buffer write 2N µs (00h = not supported)
21h
42h
0009h
Typical timeout per individual block erase 2N ms
22h
44h
0000h
Typical timeout for full chip erase 2N ms (00h = not supported)
23h
46h
0005h
Max. timeout for byte/word write 2N times typical
24h
48h
0000h
Max. timeout for buffer write 2N times typical
25h
4Ah
0004h
Max. timeout per individual block erase 2N times typical
26h
4Ch
0000h
Max. timeout for full chip erase 2N times typical (00h = not supported)
Table 11.
Description
Device Geometry Definition
Addresses
(Word Mode)
Addresses
(Byte Mode)
Data
27h
4Eh
0016h
Device Size = 2N byte
28h
29h
50h
52h
0002h
0000h
Flash Device Interface description (refer to CFI publication 100)
2Ah
2Bh
54h
56h
0000h
0000h
Max. number of bytes in multi-byte write = 2N
(00h = not supported)
2Ch
58h
0002h
Number of Erase Block Regions within device
2Dh
2Eh
2Fh
30h
5Ah
5Ch
5Eh
60h
0007h
0000h
0020h
0000h
Erase Block Region 1 Information
(refer to the CFI specification or CFI publication 100)
31h
32h
33h
34h
62h
64h
66h
68h
003Eh
0000h
0000h
0001h
Erase Block Region 2 Information
35h
36h
37h
38h
6Ah
6Ch
6Eh
70h
0000h
0000h
0000h
0000h
Erase Block Region 3 Information
39h
3Ah
3Bh
3Ch
72h
74h
76h
78h
0000h
0000h
0000h
0000h
Erase Block Region 4 Information
22
Description
Am29DS320G
January 27, 2003
A D V A N C E
Table 12.
I N F O R M A T I O N
Primary Vendor-Specific Extended Query
Addresses
(Word Mode)
Addresses
(Byte Mode)
Data
40h
41h
42h
80h
82h
84h
0050h
0052h
0049h
Query-unique ASCII string “PRI”
43h
86h
0031h
Major version number, ASCII
44h
88h
0033h
Minor version number, ASCII
45h
8Ah
0001h
Silicon Revision Number
00h = 0.23 µm, 01h = 0.17 µm
46h
8Ch
0002h
Erase Suspend
0 = Not Supported, 1 = To Read Only, 2 = To Read & Write
47h
8Eh
0001h
Sector Protect
0 = Not Supported, X = Number of sectors in per group
48h
90h
0001h
Sector Temporary Unprotect
00 = Not Supported, 01 = Supported
49h
92h
0004h
Sector Protect/Unprotect scheme
04 = 29LV800 mode
4Ah
94h
0038h
Simultaneous Operation
Number of Sectors (excluding Bank 1)
4Bh
96h
0000h
Burst Mode Type
00 = Not Supported, 01 = Supported
4Ch
98h
0000h
Page Mode Type
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page
4Dh
9Ah
0085h
4Eh
9Ch
0095h
4Fh
9Eh
000Xh
Description
ACC (Acceleration) Supply Minimum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
ACC (Acceleration) Supply Maximum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
Top/Bottom Boot Sector Flag
02h = Bottom Boot Device, 03h = Top Boot Device
COMMAND DEFINITIONS
Writing specific address and data commands or sequences into the command register initiates device operations. Table 13 defines the valid register command
sequences. Writing incorrect address and data values
or writing them in the improper sequence resets the
device to an unknown state. A reset command is required to return the device to reading array data.
All addresses are latched on the falling edge of WE#
or CE#, whichever happens later. All data is latched on
the rising edge of WE# or CE#, whichever happens
first. Refer to the AC Characteristics section for timing
diagrams.
Reading Array Data
The device is automatically set to reading array data
after device power-up. No commands are required to
retrieve data. Each bank is ready to read array data
January 27, 2003
after completing an Embedded Program or Embedded
Erase algorithm.
After the device accepts an Erase Suspend command,
the corresponding bank enters the erase-suspend-read mode, after which the system can read
data from any non-erase-suspended sector within the
same bank. After completing a programming operation
in the Erase Suspend mode, the system may once
again read array data with the same exception. See
the Erase Suspend/Erase Resume Commands section for more information. Note that the ACC function
and unlock bypass modes are not available when the
SecSi Sector is enabled.
The system must issue the reset command to return a
bank to the read (or erase-suspend-read) mode if DQ5
goes high during an active program or erase opera-
Am29DS320G
23
A D V A N C E
I N F O R M A T I O N
tion, or if the bank is in the autoselect mode. See the
next section, Reset Command, for more information.
See also Requirements for Reading Array Data in the
Device Bus Operations section for more information.
The Read-Only Operations table provides the read parameters, and Figure 14 shows the timing diagram.
Reset Command
Writing the reset command resets the banks to the
read or erase-suspend-read mode. Address bits are
don’t cares for this command.
The reset command may be written between the sequence cycles in an erase command sequence before
erasing begins. This resets the bank to which the system was writing to the read mode. Once erasure begins, however, the device ignores reset commands
until the operation is complete.
The reset command may be written between the
sequence cycles in a program command sequence
before programming begins. This resets the bank to
which the system was writing to the read mode. If the
program command sequence is written to a bank that
is in the Erase Suspend mode, writing the reset
co m m an d re tur ns tha t b an k to th e er as e- s us pend-read mode. Once programming begins, however, the device ignores reset commands until the
operation is complete.
write cycle that contains the bank address and the autoselect command. The bank then enters the autoselect mode. The system may read at any address within
the same bank any number of times without initiating
another autoselect command sequence:
■ A read cycle at address (BA)XX00h (where BA is
the bank address) returns the manufacturer code.
■ A read cycle at address (BA)XX01h in word mode
(or (BA)XX02h in byte mode) returns the device
code.
■ A read cycle to an address containing a sector address (SA) within the same bank, and the address
02h on A7–A0 in word mode (or the address 04h on
A6–A-1 in byte mode) returns 01h if the sector is
protected, or 00h if it is unprotected. (Refer to Table
2 for valid sector addresses).
The system must write the reset command to return to
the read mode (or erase-suspend-read mode if the
bank was previously in Erase Suspend).
Enter SecSiTM Sector/Exit SecSi Sector
Command Sequence
If DQ5 goes high during a program or erase operation,
writing the reset command returns the banks to the
read mode (or erase-suspend-read mode if that bank
was in Erase Suspend).
The SecSi Sector region provides a secured data area
containing a random, sixteen-byte electronic serial
number (ESN). The system can access the SecSi
Sector region by issuing the three-cycle Enter SecSi
Sector command sequence. The device continues to
access the SecSi Sector region until the system issues the four-cycle Exit SecSi Sector command sequence. The Exit SecSi Sector command sequence
returns the device to normal operation. The SecSi
Sector is not accessible when the device is executing
an Embedded Program or Embedded Erase algorithm. Table 13 shows the address and data requirements for both command sequences. See also
“SecSiTM (Secured Silicon) Sector Flash
Memory Region” for further information. Note that the
ACC function and unlock bypass modes are not available when the SecSi Sector is enabled.
Autoselect Command Sequence
Byte/Word Program Command Sequence
The autoselect command sequence allows the host
system to access the manufacturer and device codes,
and determine whether or not a sector is protected.
Table 13 shows the address and data requirements.
This method is an alternative to that shown in Table 6,
which is intended for PROM programmers and requires V ID on address pin A9. The autoselect command sequence may be written to an address within a
bank that is either in the read or erase-suspend-read
mode. The autoselect command may not be written
while the device is actively programming or erasing in
the other bank.
The system may program the device by word or byte,
depending on the state of the BYTE# pin. Programming is a four-bus-cycle operation. The program command sequence is initiated by writing two unlock write
cycles, followed by the program set-up command. The
program address and data are written next, which in
turn initiate the Embedded Program algorithm. The
system is not required to provide further controls or
timings. The device automatically provides internally
generated program pulses and verifies the programmed cell margin. Table 13 shows the address
and data requirements for the byte program command
sequence.
The reset command may be written between the sequence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command
must be written to return to the read mode. If a bank
entered the autoselect mode while in the Erase Suspend mode, writing the reset command returns that
bank to the erase-suspend-read mode.
The autoselect command sequence is initiated by first
writing two unlock cycles. This is followed by a third
24
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
When the Embedded Program algorithm is complete,
that bank then returns to the read mode and addresses are no longer latched. The system can determine the status of the program operation by using
DQ7, DQ6, or RY/BY#. Refer to the Write Operation
Status section for information on these status bits.
Any commands written to the device during the Embedded Program Algorithm are ignored. Note that a
hardware reset immediately terminates the program
operation. The program command sequence should
be reinitiated once that bank has returned to the read
mode, to ensure data integrity. Note that the SecSi
Sector, autoselect, and CFI functions are unavailable
when a program operation is in progress.
the WP#/ACC pin must not be at VHH any operation
other than accelerated programming, or device damage may result. In addition, the WP#/ACC pin must not
be left floating or unconnected; inconsistent behavior
of the device may result.
Figure 4 illustrates the algorithm for the program operation. Refer to the Erase and Program Operations
table in the AC Characteristics section for parameters,
and Figure 18 for timing diagrams.
START
Programming is allowed in any sequence and across
sector boundaries. A bit cannot be programmed
from “0” back to a “1.” Attempting to do so may
cause that bank to set DQ5 = 1, or cause the DQ7 and
DQ6 status bits to indicate the operation was successful. However, a succeeding read will show that the
data is still “0.” Only erase operations can convert a
“0” to a “1.”
Write Program
Command Sequence
Embedded
Program
algorithm
in progress
Unlock Bypass Command Sequence
The unlock bypass feature allows the system to program bytes or words to a bank faster than using the
standard program command sequence. The unlock
bypass command sequence is initiated by first writing
two unlock cycles. This is followed by a third write
cycle containing the unlock bypass command, 20h.
That bank then enters the unlock bypass mode. A
two-cycle unlock bypass program command sequence
is all that is required to program in this mode. The first
cycle in this sequence contains the unlock bypass program command, A0h; the second cycle contains the
program address and data. Additional data is programmed in the same manner. This mode dispenses
with the initial two unlock cycles required in the standard program command sequence, resulting in faster
total programming time. Table 13 shows the requirements for the command sequence.
During the unlock bypass mode, only the Unlock Bypass Program and Unlock Bypass Reset commands
are valid. To exit the unlock bypass mode, the system
must issue the two-cycle unlock bypass reset command sequence. The first cycle must contain the bank
address and the data 90h. The second cycle need
only contain the data 00h. The bank then returns to
the read mode.
The device offers accelerated program operations
through the WP#/ACC pin. When the system asserts
VHH on the WP#/ACC pin, the device automatically enters the Unlock Bypass mode. The system may then
write the two-cycle Unlock Bypass program command
sequence. The device uses the higher voltage on the
WP#/ACC pin to accelerate the operation. Note that
January 27, 2003
Data Poll
from System
Verify Data?
No
Yes
Increment Address
No
Last Address?
Yes
Programming
Completed
Note: See Table 13 for program command sequence.
Figure 4.
Program Operation
Chip Erase Command Sequence
Chip erase is a six bus cycle operation. The chip erase
command sequence is initiated by writing two unlock
cycles, followed by a set-up command. Two additional
unlock write cycles are then followed by the chip erase
command, which in turn invokes the Embedded Erase
algorithm. The device does not require the system to
preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire
memory for an all zero data pattern prior to electrical
erase. The system is not required to provide any con-
Am29DS320G
25
A D V A N C E
I N F O R M A T I O N
trols or timings during these operations. Table 13
shows the address and data requirements for the chip
erase command sequence.
and commands. Note that the SecSi Sector, autoselect, and CFI functions are unavailable when an erase
operation is in progress.
When the Embedded Erase algorithm is complete,
that bank returns to the read mode and addresses are
no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, DQ2,
or RY/BY#. Refer to the Write Operation Status section for information on these status bits. Note that the
SecSi Sector, autoselect, and CFI functions are unavailable when an erase operation is in progress.
The system can monitor DQ3 to determine if the sector erase timer has timed out (See the section on DQ3:
Sector Erase Timer.). The time-out begins from the rising edge of the final WE# pulse in the command
sequence.
Any commands written during the chip erase operation
are ignored. However, note that a hardware reset immediately terminates the erase operation. If that occurs, the chip erase command sequence should be
reinitiated once that bank has returned to reading
array data, to ensure data integrity.
Figure 5 illustrates the algorithm for the erase operation. Refer to the Erase and Program Operations tables in the AC Characteristics section for parameters,
and Figure 20 section for timing diagrams.
Sector Erase Command Sequence
Sector erase is a six bus cycle operation. The sector
erase command sequence is initiated by writing two
unlock cycles, followed by a set-up command. Two additional unlock cycles are written, and are then followed by the address of the sector to be erased, and
the sector erase command. Table 13 shows the address and data requirements for the sector erase command sequence.
The device does not require the system to preprogram
prior to erase. The Embedded Erase algorithm automatically programs and verifies the entire memory for
an all zero data pattern prior to electrical erase. The
system is not required to provide any controls or timings during these operations.
After the command sequence is written, a sector erase
time-out of 50 µs occurs. During the time-out period,
additional sector addresses and sector erase commands (for sectors within the same bank) may be written. Loading the sector erase buffer may be done in
any sequence, and the number of sectors may be from
one sector to all sectors. The time between these additional cycles must be less than 50 µs, otherwise erasure may begin. Any sector erase address and
command following the exceeded time-out may or
may not be accepted. It is recommended that processor interrupts be disabled during this time to ensure all
commands are accepted. The interrupts can be re-enabled after the last Sector Erase command is written.
Any command other than Sector Erase or Erase
Suspend during the time-out period resets that
bank to the read mode. The system must rewrite the
command sequence and any additional addresses
26
When the Embedded Erase algorithm is complete, the
bank returns to reading array data and addresses are
no longer latched. Note that while the Embedded
Erase operation is in progress, the system can read
data from the non-erasing bank. The system can determine the status of the erase operation by reading
DQ7, DQ6, DQ2, or RY/BY# in the erasing bank.
Refer to the Write Operation Status section for information on these status bits.
Once the sector erase operation has begun, only the
Erase Suspend command is valid. All other commands are ignored. However, note that a hardware
reset immediately terminates the erase operation. If
that occurs, the sector erase command sequence
should be reinitiated once that bank has returned to
reading array data, to ensure data integrity.
Figure 5 illustrates the algorithm for the erase operation. Refer to the Erase and Program Operations tables in the AC Characteristics section for parameters,
and Figure 20 section for timing diagrams.
Erase Suspend/Erase Resume
Commands
The Erase Suspend command, B0h, allows the system to interrupt a sector erase operation and then read
data from, or program data to, any sector not selected
for erasure. The bank address is required when writing
this command. This command is valid only during the
sector erase operation, including the 50 µs time-out
period during the sector erase command sequence.
The Erase Suspend command is ignored if written during the chip erase operation or Embedded Program
algorithm.
When the Erase Suspend command is written during
the sector erase operation, the device requires a maximum of 20 µs to suspend the erase operation. However, when the Erase Suspend command is written
during the sector erase time-out, the device immediately terminates the time-out period and suspends the
erase operation.
After the erase operation has been suspended, the
bank enters the erase-suspend-read mode. The system can read data from or program data to any sector
not selected for erasure. (The device “erase suspends” all sectors selected for erasure.) Reading at
any address within erase-suspended sectors produces status information on DQ7–DQ0. The system
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
can use DQ7, or DQ6 and DQ2 together, to determine
if a sector is actively erasing or is erase-suspended.
Refer to the Write Operation Status section for information on these status bits.
START
After an erase-suspended program operation is complete, the bank returns to the erase-suspend-read
mode. The system can determine the status of the
program operation using the DQ7 or DQ6 status bits,
just as in the standard Byte Program operation.
Refer to the Write Operation Status section for more
information.
Write Erase
Command Sequence
(Notes 1, 2)
Data Poll to Erasing
Bank from System
In the erase-suspend-read mode, the system can also
issue the autoselect command sequence. Refer to the
Autoselect Mode and Autoselect Command Sequence
sections for details.
To resume the sector erase operation, the system
must write the Erase Resume command. The bank
address of the erase-suspended bank is required
when writing this command. Further writes of the Resume command are ignored. Another Erase Suspend
command can be written after the chip has resumed
erasing.
No
Embedded
Erase
algorithm
in progress
Data = FFh?
Yes
Erasure Completed
Notes:
1. See Table 13 for erase command sequence.
2. See the section on DQ3 for information on the sector
erase timer.
Figure 5.
January 27, 2003
Am29DS320G
Erase Operation
27
A D V A N C E
Table 13.
Read (Note 6)
Reset (Note 7)
Autoselect (Note 8)
Manufacturer ID
Device ID (Note 9)
Word
Byte
Word
Byte
SecSi Sector Factory
Protect (Note 10)
Word
Sector/Sector Block
Protect Verify
(Note 11)
Word
Enter SecSi Sector Region
Exit SecSi Sector Region
Program
Unlock Bypass
Byte
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Unlock Bypass Program (Note 12)
Unlock Bypass Reset (Note 13)
Chip Erase
Sector Erase
Word
Byte
Word
Byte
Addr
Data
1
RA
RD
1
XXX
F0
4
6
4
First
555
AAA
555
AAA
555
AAA
Second
AA
AA
AA
555
4
3
4
4
3
2
2
6
6
AAA
555
AAA
555
AAA
555
AAA
555
AAA
AA
AA
AA
AA
555
2AA
555
2AA
555
55
55
55
555
2AA
555
2AA
555
2AA
555
2AA
555
00
555
AAA
AA
BA
B0
BA
30
55
AA
555
2AA
555
(BA)AAA
555
AAA
555
AAA
555
AAA
555
55
XXX
AA
(BA)555
(BA)AAA
55
90
AAA
(BA)555
(BA)AAA
55
BA
2AA
(BA)555
(BA)AAA
55
PD
555
Third
Addr
Fourth
AAA
555
55
AAA
555
55
AAA
Fifth
Data
Addr
Data
90
(BA)X00
01
90
90
(BA)555
55
PA
1
1
2AA
A0
1
Byte
Data
XXX
Erase Resume (Note 15)
CFI Query (Note 16)
Addr
2AA
AA
Erase Suspend (Note 14)
Word
Command Definitions
Bus Cycles (Notes 2–5)
Cycles
Command
Sequence
(Note 1)
I N F O R M A T I O N
(BA)X01
(BA)X02
(BA)X03
(BA)X06
7E
Addr
(BA)X0E
(BA)X1C
Sixth
Data
0A
Addr
Data
(BA)X0F
00/
01
(BA)X1E
81/01
(SA)X02
90
(SA)X04
00/01
88
90
XXX
00
A0
PA
PD
20
80
80
555
AAA
555
AAA
AA
AA
2AA
555
2AA
555
55
55
555
AAA
SA
10
30
98
Legend:
X = Don’t care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses
latch on the falling edge of the WE# or CE# pulse, whichever happens
later.
PD = Data to be programmed at location PA. Data latches on the rising
edge of WE# or CE# pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or
erased. Address bits A20–A12 uniquely select any sector.
BA = Address of the bank that is being switched to autoselect mode, is
in bypass mode, or is being erased.
Notes:
1. See Table 1 for description of bus operations.
9.
The device ID must be read across three cycles. The device ID is
00h for bottom boot devices, and 01h for top boot devices.
2.
All values are in hexadecimal.
3.
Except for the read cycle and the fourth cycle of the autoselect
command sequence, all bus cycles are write cycles.
4.
Data bits DQ15–DQ8 are don’t care in command sequences,
except for RD and PD.
5.
Unless otherwise noted, address bits A20–A11 are don’t cares.
12. The Unlock Bypass command is required prior to the Unlock
Bypass Program command.
6.
No unlock or command cycles required when bank is reading
array data.
13. The Unlock Bypass Reset command is required to return to the
read mode when the bank is in the unlock bypass mode.
7.
The Reset command is required to return to the read mode (or to
the erase-suspend-read mode if previously in Erase Suspend)
when a bank is in the autoselect mode, or if DQ5 goes high (while
the bank is providing status information).
14. The system may read and program in non-erasing sectors, or
enter the autoselect mode, when in the Erase Suspend mode.
The Erase Suspend command is valid only during a sector erase
operation, and requires the bank address.
8.
The fourth cycle of the autoselect command sequence is a read
cycle. The system must provide the bank address to obtain the
manufacturer ID, device ID, or SecSi Sector factory protect
information. Data bits DQ15–DQ8 are don’t care. See the
Autoselect Command Sequence section for more information.
15. The Erase Resume command is valid only during the Erase
Suspend mode, and requires the bank address.
28
10. The data is 81h for factory locked and 01h for not factory locked.
11. The data is 00h for an unprotected sector/sector block and 01h
for a protected sector/sector block.
16. Command is valid when device is ready to read array data or when
device is in autoselect mode.
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
WRITE OPERATION STATUS
The device provides several bits to determine the status of
a program or erase operation: DQ2, DQ3, DQ5, DQ6, and
DQ7. Table 14 and the following subsections describe the
function of these bits. DQ7 and DQ6 each offer a method
for determining whether a program or erase operation is
complete or in progress. The device also provides a hardware-based output signal, RY/BY#, to determine whether
an Embedded Program or Erase operation is in progress or
has been completed.
invalid. Valid data on DQ7–DQ0 will appear on successive read cycles.
Table 14 shows the outputs for Data# Polling on DQ7.
Figure 6 shows the Data# Polling algorithm. Figure 22
in the AC Characteristics section shows the Data#
Polling timing diagram.
DQ7: Data# Polling
START
The Data# Polling bit, DQ7, indicates to the host system
whether an Embedded Program or Erase algorithm is in
progress or completed, or whether a bank is in Erase Suspend. Data# Polling is valid after the rising edge of the final
WE# pulse in the command sequence.
Read DQ7–DQ0
Addr = VA
During the Embedded Program algorithm, the device outputs on DQ7 the complement of the datum programmed to
DQ7. This DQ7 status also applies to programming during
Erase Suspend. When the Embedded Program algorithm is
complete, the device outputs the datum programmed to
DQ7. The system must provide the program address to
read valid status information on DQ7. If a program address
falls within a protected sector, Data# Polling on DQ7 is active for approximately 1 µs, then that bank returns to the
read mode.
DQ7 = Data?
No
No
Just prior to the completion of an Embedded Program
or Erase operation, DQ7 may change asynchronously
with DQ0–DQ6 while Output Enable (OE#) is asserted
low. That is, the device may change from providing
status information to valid data on DQ7. Depending on
when the system samples the DQ7 output, it may read
the status or valid data. Even if the device has completed the program or erase operation and DQ7 has
valid data, the data outputs on DQ0–DQ6 may be still
January 27, 2003
DQ5 = 1?
Yes
During the Embedded Erase algorithm, Data# Polling
produces a “0” on DQ7. When the Embedded Erase
algorithm is complete, or if the bank enters the Erase
Suspend mode, Data# Polling produces a “1” on DQ7.
The system must provide an address within any of the
sectors selected for erasure to read valid status information on DQ7.
After an erase command sequence is written, if all
sectors selected for erasing are protected, Data# Polling on DQ7 is active for approximately 100 µs, then
the bank returns to the read mode. If not all selected
sectors are protected, the Embedded Erase algorithm
erases the unprotected sectors, and ignores the selected sectors that are protected. However, if the system reads DQ7 at an address within a protected
sector, the status may not be valid.
Yes
Read DQ7–DQ0
Addr = VA
DQ7 = Data?
Yes
No
FAIL
PASS
Notes:
1. VA = Valid address for programming. During a sector
erase operation, a valid address is any sector address
within the sector being erased. During chip erase, a
valid address is any non-protected sector address.
2. DQ7 should be rechecked even if DQ5 = “1” because
DQ7 may change simultaneously with DQ5.
Am29DS320G
Figure 6.
Data# Polling Algorithm
29
A D V A N C E
I N F O R M A T I O N
RY/BY#: Ready/Busy#
The RY/BY# is a dedicated, open-drain output pin
which indicates whether an Embedded Algorithm is in
progress or complete. The RY/BY# status is valid after
the rising edge of the final WE# pulse in the command
sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a
pull-up resistor to VCC.
Table 14 shows the outputs for Toggle Bit I on DQ6.
Figure 7 shows the toggle bit algorithm. Figure 23 in
the “AC Characteristics” section shows the toggle bit
timing diagrams. Figure 24 shows the differences between DQ2 and DQ6 in graphical form. See also the
subsection on DQ2: Toggle Bit II.
If the output is low (Busy), the device is actively erasing or programming. (This includes programming in
the Erase Suspend mode.) If the output is high
(Ready), the device is in the read mode, the standby
mode, or one of the banks is in the erase-suspend-read mode.
START
Read DQ7–DQ0
Table 14 shows the outputs for RY/BY#.
Read DQ7–DQ0
DQ6: Toggle Bit I
Toggle Bit I on DQ6 indicates whether an Embedded
Program or Erase algorithm is in progress or complete, or whether the device has entered the Erase
Suspend mode. Toggle Bit I may be read at any address, and is valid after the rising edge of the final
WE# pulse in the command sequence (prior to the
program or erase operation), and during the sector
erase time-out.
During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause
DQ6 to toggle. The system may use either OE# or
CE# to control the read cycles. When the operation is
complete, DQ6 stops toggling.
Toggle Bit
= Toggle?
Yes
No
If a program address falls within a protected sector,
DQ6 toggles for approximately 1 µs after the program
command sequence is written, then returns to reading
array data.
Read DQ7–DQ0
Twice
Toggle Bit
= Toggle?
No
Yes
Program/Erase
Operation Not
Complete, Write
Reset Command
Program/Erase
Operation Complete
Note: The system should recheck the toggle bit even if DQ5
= “1” because the toggle bit may stop toggling as DQ5
changes to “1.” See the subsections on DQ6 and DQ2 for
more information.
DQ6 also toggles during the erase-suspend-program
mode, and stops toggling once the Embedded Program algorithm is complete.
30
DQ5 = 1?
Yes
After an erase command sequence is written, if all sectors
selected for erasing are protected, DQ6 toggles for approximately 100 µs, then returns to reading array data. If not all
selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected.
The system can use DQ6 and DQ2 together to determine
whether a sector is actively erasing or is erase-suspended.
When the device is actively erasing (that is, the Embedded
Erase algorithm is in progress), DQ6 toggles. When the device enters the Erase Suspend mode, DQ6 stops toggling.
However, the system must also use DQ2 to determine
which sectors are erasing or erase-suspended. Alternatively, the system can use DQ7 (see the subsection on
DQ7: Data# Polling).
No
Am29DS320G
Figure 7.
Toggle Bit Algorithm
January 27, 2003
A D V A N C E
I N F O R M A T I O N
DQ2: Toggle Bit II
The “Toggle Bit II” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing
(that is, the Embedded Erase algorithm is in progress),
or whether that sector is erase-suspended. Toggle Bit
II is valid after the rising edge of the final WE# pulse in
the command sequence.
the toggle bit and DQ5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to perform
other system tasks. In this case, the system must start
at the beginning of the algorithm when it returns to determine the status of the operation (top of Figure 7).
DQ5: Exceeded Timing Limits
DQ2 toggles when the system reads at addresses
within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish
whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the
device is actively erasing, or is in Erase Suspend, but
cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and
mode information. Refer to Table 14 to compare outputs for DQ2 and DQ6.
DQ5 indicates whether the program or erase time has
exceeded a specified internal pulse count limit. Under these
conditions DQ5 produces a “1,” indicating that the program
or erase cycle was not successfully completed.
Figure 7 shows the toggle bit algorithm in flowchart
form, and the section “DQ2: Toggle Bit II” explains the
algorithm. See also the DQ6: Toggle Bit I subsection.
Figure 23 shows the toggle bit timing diagram. Figure
24 shows the differences between DQ2 and DQ6 in
graphical form.
Under both these conditions, the system must write
the reset command to return to the read mode (or to
the erase-suspend-read mode if a bank was previously in the erase-suspend-program mode).
Reading Toggle Bits DQ6/DQ2
Refer to Figure 7 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row to
determine whether a toggle bit is toggling. Typically,
the system would note and store the value of the toggle bit after the first read. After the second read, the
system would compare the new value of the toggle bit
with the first. If the toggle bit is not toggling, the device
has completed the program or erase operation. The
system can read array data on DQ7–DQ0 on the following read cycle.
However, if after the initial two read cycles, the system
determines that the toggle bit is still toggling, the system also should note whether the value of DQ5 is high
(see the section on DQ5). If it is, the system should
then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling
just as DQ5 went high. If the toggle bit is no longer
toggling, the device has successfully completed the
program or erase operation. If it is still toggling, the device did not completed the operation successfully, and
the system must write the reset command to return to
reading array data.
The remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5 has
not gone high. The system may continue to monitor
January 27, 2003
The device may output a “1” on DQ5 if the system tries
to program a “1” to a location that was previously programmed to “0.” Only an erase operation can
change a “0” back to a “1.” Under this condition, the
device halts the operation, and when the timing limit
has been exceeded, DQ5 produces a “1.”
DQ3: Sector Erase Timer
After writing a sector erase command sequence, the
system may read DQ3 to determine whether or not
erasure has begun. (The sector erase timer does not
apply to the chip erase command.) If additional
sectors are selected for erasure, the entire time-out
also applies after each additional sector erase command. When the time-out period is complete, DQ3
switches from a “0” to a “1.” If the time between additional sector erase commands from the system can be
assumed to be less than 50 µs, the system need not
monitor DQ3. See also the Sector Erase Command
Sequence section.
After the sector erase command is written, the system
should read the status of DQ7 (Data# Polling) or DQ6
(Toggle Bit I) to ensure that the device has accepted
the command sequence, and then read DQ3. If DQ3 is
“1,” the Embedded Erase algorithm has begun; all further commands (except Erase Suspend) are ignored
until the erase operation is complete. If DQ3 is “0,” the
device will accept additional sector erase commands.
To ensure the command has been accepted, the system software should check the status of DQ3 prior to
and following each subsequent sector erase command. If DQ3 is high on the second status check, the
last command might not have been accepted.
Table 14 shows the status of DQ3 relative to the other
status bits.
Am29DS320G
31
A D V A N C E
Table 14.
Standard
Mode
Erase
Suspend
Mode
Status
Embedded Program Algorithm
Embedded Erase Algorithm
Erase
Erase-Suspend- Suspended Sector
Read
Non-Erase
Suspended Sector
Erase-Suspend-Program
I N F O R M A T I O N
Write Operation Status
DQ7
(Note 2)
DQ7#
0
DQ6
Toggle
Toggle
DQ5
(Note 1)
0
0
DQ3
N/A
1
DQ2
(Note 2)
No toggle
Toggle
RY/BY#
0
0
1
No toggle
0
N/A
Toggle
1
Data
Data
Data
Data
Data
1
DQ7#
Toggle
0
N/A
N/A
0
Notes:
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits.
Refer to the section on DQ5 for more information.
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further
details.
3. When reading write operation status bits, the system must always provide the bank address where the Embedded Algorithm
is in progress. The device outputs array data if the system addresses a non-busy bank.
32
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +150°C
20 ns
Ambient Temperature
with Power Applied . . . . . . . . . . . . . –65°C to +125°C
+0.8 V
Voltage with Respect to Ground
–0.5 V
VCC (Note 1) . . . . . . . . . . . . . . . . .–0.5 V to +4.0 V
A9, OE#, and RESET#
(Note 2) . . . . . . . . . . . . . . . . . . . . –0.5 V to +11.0 V
20 ns
–2.0 V
20 ns
WP#/ACC . . . . . . . . . . . . . . . . . .–0.5 V to +10.5 V
All other pins (Note 1) . . . . . . –0.5 V to VCC +0.5 V
Figure 8. Maximum Negative
Overshoot Waveform
Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V.
During voltage transitions, input or I/O pins may
overshoot V SS to –2.0 V for periods of up to 20 ns.
Maximum DC voltage on input or I/O pins is VCC +0.5 V.
See Figure 8. During voltage transitions, input or I/O pins
may overshoot to VCC +2.0 V for periods up to 20 ns. See
Figure 9.
2. Minimum DC input voltage on pins A9, OE#, RESET#,
and WP#/ACC is –0.5 V. During voltage transitions, A9,
OE#, WP#/ACC, and RESET# may overshoot VSS to
–2.0 V for periods of up to 20 ns. See Figure 8. Maximum
DC input voltage on pin A9 is +12.5 V which may
overshoot to +14.0 V for periods up to 20 ns. Maximum
DC input voltage on WP#/ACC is +9.5 V which may
overshoot to +12.0 V for periods up to 20 ns.
20 ns
VCC
+2.0 V
VCC
+0.5 V
2.0 V
3. No more than one output may be shorted to ground at a
time. Duration of the short circuit should not be greater
than one second.
20 ns
20 ns
Figure 9. Maximum Positive
Overshoot Waveform
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This
is a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to absolute maximum rating
conditions for extended periods may affect device reliability.
OPERATING RANGES
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . –40°C to +85°C
Extended (E) Devices
Ambient Temperature (TA) . . . . . . . . –55°C to +125°C
VCC Supply Voltages
VCC for standard voltage range . . . . . . . 1.8 V to 2.2 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.
January 27, 2003
Am29DS320G
33
A D V A N C E
I N F O R M A T I O N
DC CHARACTERISTICS
CMOS Compatible
Parameter
Symbol
Parameter Description
Test Conditions
Min
ILI
Input Load Current
VIN = VSS to VCC,
VCC = VCC max
ILIT
A9 Input Load Current
VCC = VCC max; A9 = 12.5 V
ILO
Output Leakage Current
VOUT = VSS to VCC,
VCC = VCC max
Typ
Max
Unit
±3.0
µA
35
µA
±3.0
µA
CE# = VIL, OE# = VIH,
Byte Mode
5 MHz
5
16
1 MHz
1
4
CE# = VIL, OE# = VIH,
Word Mode
5 MHz
5
15
1 MHz
1
4
ICC2
VCC Active Write Current (Notes 2, 3) CE# = VIL, OE# = VIH, WE# = VIL
10
15
mA
ICC3
VCC Standby Current (Note 2)
CE#, RESET# = VCC ± 0.3 V
0.2
5
µA
ICC4
VCC Reset Current (Note 2)
RESET# = VSS ± 0.3 V
0.2
5
µA
ICC5
Automatic Sleep Mode (Notes 2, 4)
VIH = VCC ± 0.3 V;
VIL = VSS ± 0.3 V
0.2
5
µA
VCC Active Read-While-Program
Current (Notes 1, 2)
Byte
15
25
ICC6
CE# = VIL, OE# = VIH
Word
15
25
VCC Active Read-While-Erase
Current (Notes 1, 2)
Byte
15
25
ICC7
CE# = VIL, OE# = VIH
Word
15
25
ICC8
VCC Active
Program-While-Erase-Suspended
Current (Notes 2, 5)
CE# = VIL, OE# = VIH
10
15
mA
ACC Accelerated Program Current,
Word or Byte
ACC pin
5
10
mA
IACC
CE# = VIL, OE# = VIH
VCC pin
10
15
mA
VIL
Input Low Voltage
–0.5
0.8
V
VIH
Input High Voltage
0.7 x VCC
VCC + 0.3
V
VHH
Voltage for WP#/ACC Sector
Protect/Unprotect and Program
Acceleration
VCC = 3.0 V ± 10%
8.5
9.5
V
VID
Voltage for Autoselect and
Temporary Sector Unprotect
VCC = 3.0 V ± 10%
9.0
11.0
V
VOL
Output Low Voltage
IOL = 4.0 mA, VCC = VCC min
0.25
V
ICC1
VOH1
VCC Active Read Current
(Notes 1, 2)
Output High Voltage
VOH2
VLKO
mA
IOH = –2.0 mA, VCC = VCC min
0.7x VCC
IOH = –100 µA, VCC = VCC min
VCC–0.1
Low VCC Lock-Out Voltage (Note 5)
mA
mA
V
1.5
V
Notes:
1. The ICC current listed is typically less than 2 mA/MHz, with OE# at VIH.
2. Maximum ICC specifications are tested with VCC = VCCmax.
3. ICC active while Embedded Erase or Embedded Program is in progress.
4. Automatic sleep mode enables the low power mode when addresses remain stable for tACC + 30 ns. Typical sleep mode current is
200 nA.
5. Not 100% tested.
34
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
DC CHARACTERISTICS
Zero-Power Flash
25
Supply Current in mA
20
15
10
5
0
0
500
1000
1500
2000
2500
3000
3500
4000
Time in ns
Note: Addresses are switching at 1 MHz
Figure 10.
ICC1 Current vs. Time (Showing Active and Automatic Sleep Currents)
12
10
Supply Current in mA
8
2.2 V
6
4
1.8 V
2
0
1
2
3
4
5
Frequency in MHz
Note: T = 25 °C
Figure 11.
January 27, 2003
Typical ICC1 vs. Frequency
Am29DS320G
35
A D V A N C E
I N F O R M A T I O N
TEST CONDITIONS
Table 15.
Test Specifications
Test Condition
70, 90
Output Load
Device
Under
Test
30
Input Rise and Fall Times
Figure 12.
100
pF
5
ns
0.0–2.0
V
Input timing measurement
reference levels
1.0
V
Output timing measurement
reference levels
1.0
V
Input Pulse Levels
Note: Diodes are IN3064 or equivalent
Unit
1 TTL gate
Output Load Capacitance, CL
(including jig capacitance)
CL
120
Test Setup
KEY TO SWITCHING WAVEFORMS
WAVEFORM
INPUTS
OUTPUTS
Steady
Changing from H to L
Changing from L to H
2.0 V
Input
Don’t Care, Any Change Permitted
Changing, State Unknown
Does Not Apply
Center Line is High Impedance State (High Z)
1.0V
Measurement Level
1.0 V
Output
0.0 V
Figure 13.
36
Input Waveforms and Measurement Levels
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Read-Only Operations
Parameter
Speed Options
JEDEC
Std.
Description
Test Setup
70
90
120
Unit
tAVAV
tRC
Read Cycle Time (Note 1)
Min
70
90
120
ns
tAVQV
tACC
Address to Output Delay
CE#, OE# = VIL
Max
70
90
120
ns
tELQV
tCE
Chip Enable to Output Delay
OE# = VIL
Max
70
90
120
ns
tGLQV
tOE
Output Enable to Output Delay
Max
25
40
50
ns
tEHQZ
tDF
Chip Enable to Output High Z (Note 1)
Max
16
ns
tGHQZ
tDF
Output Enable to Output High Z (Note 1)
Max
16
ns
tAXQX
tOH
Output Hold Time From Addresses, CE# or OE#,
Whichever Occurs First
Min
0
ns
Min
0
ns
tOEH
Read
Output Enable Hold Time
Toggle and
(Note 1)
Data# Polling
Min
10
ns
Notes:
1. Not 100% tested.
2. See Figure 12 and Table 15 for test specifications.
tRC
Addresses Stable
Addresses
tACC
CE#
tRH
tRH
tDF
tOE
OE#
tOEH
WE#
tCE
tOH
HIGH Z
HIGH Z
Output Valid
Outputs
RESET#
RY/BY#
0V
Figure 14.
January 27, 2003
Read Operation Timings
Am29DS320G
37
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Hardware Reset (RESET#)
Parameter
JEDEC
Std
Description
All Speed Options
Unit
tReady
RESET# Pin Low (During Embedded Algorithms)
to Read Mode (See Note)
Max
20
µs
tReady
RESET# Pin Low (NOT During Embedded
Algorithms) to Read Mode (See Note)
Max
500
ns
tRP
RESET# Pulse Width
Min
500
ns
tRH
Reset High Time Before Read (See Note)
Min
50
ns
tRPD
RESET# Low to Standby Mode
Min
20
µs
tRB
RY/BY# Recovery Time
Min
0
ns
Note: Not 100% tested.
RY/BY#
CE#, OE#
tRH
RESET#
tRP
tReady
Reset Timings NOT during Embedded Algorithms
Reset Timings during Embedded Algorithms
tReady
RY/BY#
tRB
CE#, OE#
RESET#
tRP
Figure 15.
38
Reset Timings
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Word/Byte Configuration (BYTE#)
Parameter
JEDEC
Std
Speed Options
Description
70
90
120
Unit
tELFL/tELFH
CE# to BYTE# Switching Low or High
Max
5
ns
tFLQZ
BYTE# Switching Low to Output HIGH Z
Max
16
ns
tFHQV
BYTE# Switching High to Output Active
Min
70
90
120
ns
CE#
OE#
BYTE#
BYTE#
Switching
from word
to byte
mode
tELFL
Data Output
(DQ14–DQ0)
DQ14–DQ0
Address
Input
DQ15
Output
DQ15/A-1
Data Output
(DQ7–DQ0)
tFLQZ
tELFH
BYTE#
BYTE#
Switching
from byte
to word
mode
Data Output
(DQ7–DQ0)
DQ14–DQ0
Address
Input
DQ15/A-1
Data Output
(DQ14–DQ0)
DQ15
Output
tFHQV
Figure 16.
BYTE# Timings for Read Operations
CE#
The falling edge of the last WE# signal
WE#
BYTE#
tSET
(tAS)
tHOLD (tAH)
Note: Refer to the Erase/Program Operations table for tAS and tAH specifications.
Figure 17.
January 27, 2003
BYTE# Timings for Write Operations
Am29DS320G
39
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Erase and Program Operations
Parameter
Speed Options
JEDEC
Std
Description
tAVAV
tWC
Write Cycle Time (Note 1)
Min
tAVWL
tAS
Address Setup Time
Min
tASO
Address Setup Time to OE# low during toggle bit polling
Min
15
tAH
Address Hold Time
Min
45
tAHT
Address Hold Time From CE# or OE# high
during toggle bit polling
Min
tDVWH
tDS
Data Setup Time
Min
tWHDX
tDH
Data Hold Time
Min
tOEPH
Output Enable High during toggle bit polling
Min
tGHWL
tGHWL
Read Recovery Time Before Write
(OE# High to WE# Low)
Min
0
ns
tELWL
tCS
CE# Setup Time
Min
0
ns
tWHEH
tCH
CE# Hold Time
Min
0
ns
tWLWH
tWP
Write Pulse Width
Min
35
50
65
ns
tWHDL
tWPH
Write Pulse Width High
Min
25
35
45
ns
tSR/W
Latency Between Read and Write Operations
Min
0
Byte
Typ
5
Word
Typ
7
tWLAX
70
90
120
Unit
70
90
120
ns
0
ns
15
45
ns
50
0
30
50
ns
65
0
20
ns
ns
ns
25
ns
ns
tWHWH1
tWHWH1
Programming Operation (Note 2)
tWHWH1
tWHWH1
Accelerated Programming Operation,
Word or Byte (Note 2)
Typ
4
µs
tWHWH2
tWHWH2
Sector Erase Operation (Note 2)
Typ
0.4
sec
tVCS
VCC Setup Time (Note 1)
Min
50
µs
tRB
Write Recovery Time from RY/BY#
Min
0
ns
Program/Erase Valid to RY/BY# Delay
Min
90
ns
tBUSY
µs
Notes:
1. Not 100% tested.
2. See the “Erase And Programming Performance” section for more information.
40
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
tAS
tWC
Addresses
Read Status Data (last two cycles)
555h
PA
PA
PA
tAH
CE#
tCH
OE#
tWHWH1
tWP
WE#
tWPH
tCS
tDS
tDH
PD
A0h
Data
Status
tBUSY
DOUT
tRB
RY/BY#
VCC
tVCS
Notes:
1. PA = program address, PD = program data, DOUT is the true data at the program address.
2. Illustration shows device in word mode.
Figure 18.
Program Operation Timings
VHH
WP#/ACC
VIL or VIH
VIL or VIH
tVHH
Figure 19.
January 27, 2003
tVHH
Accelerated Program Timing Diagram
Am29DS320G
41
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Erase Command Sequence (last two cycles)
tAS
tWC
2AAh
Addresses
Read Status Data
VA
SA
VA
555h for chip erase
tAH
CE#
tCH
OE#
tWP
WE#
tWPH
tCS
tWHWH2
tDS
tDH
Data
55h
In
Progress
30h
Complete
10 for Chip Erase
tBUSY
tRB
RY/BY#
tVCS
VCC
Notes:
1. SA = sector address (for Sector Erase), VA = Valid Address for reading status data (see “Write Operation Status”.
2. These waveforms are for the word mode.
Figure 20.
42
Chip/Sector Erase Operation Timings
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Addresses
tWC
tWC
tRC
Valid PA
Valid RA
tWC
Valid PA
Valid PA
tAH
tCPH
tACC
tCE
CE#
tCP
tOE
OE#
tOEH
tGHWL
tWP
WE#
tDF
tWPH
tDS
tOH
tDH
Valid
Out
Valid
In
Data
Valid
In
Valid
In
tSR/W
WE# Controlled Write Cycle
Read Cycle
Figure 21.
CE# Controlled Write Cycles
Back-to-back Read/Write Cycle Timings
tRC
Addresses
VA
VA
VA
tACC
tCE
CE#
tCH
tOE
OE#
tOEH
tDF
WE#
tOH
High Z
DQ7
Complement
Complement
DQ0–DQ6
Status Data
Status Data
True
Valid Data
High Z
True
Valid Data
tBUSY
RY/BY#
Note: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data
read cycle.
Figure 22.
January 27, 2003
Data# Polling Timings (During Embedded Algorithms)
Am29DS320G
43
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
tAHT
tAS
Addresses
tAHT
tASO
CE#
tCEPH
tOEH
WE#
tOEPH
OE#
tDH
DQ6/DQ2
tOE
Valid Data
Valid
Status
Valid
Status
Valid
Status
(first read)
(second read)
(stops toggling)
Valid Data
RY/BY#
Note: VA = Valid address; not required for DQ6. Illustration shows first two status cycle after command sequence, last status
read cycle, and array data read cycle
Figure 23.
Enter
Embedded
Erasing
WE#
Erase
Suspend
Erase
Toggle Bit Timings (During Embedded Algorithms)
Enter Erase
Suspend Program
Erase
Suspend
Program
Erase Suspend
Read
Erase
Resume
Erase Suspend
Read
Erase
Erase
Complete
DQ6
DQ2
Note: DQ2 toggles only when read at an address within an erase-suspended sector. The system may use OE# or CE# to toggle
DQ2 and DQ6.
Figure 24.
44
DQ2 vs. DQ6
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Temporary Sector Unprotect
Parameter
JEDEC
Std
Description
All Speed Options
Unit
tVIDR
VID Rise and Fall Time (See Note)
Min
500
ns
tVHH
VHH Rise and Fall Time (See Note)
Min
250
ns
tRSP
RESET# Setup Time for Temporary Sector
Unprotect
Min
4
µs
tRRB
RESET# Hold Time from RY/BY# High for
Temporary Sector Unprotect
Min
4
µs
Note: Not 100% tested.
VID
RESET#
VID
VSS, VIL,
or VIH
VSS, VIL,
or VIH
tVIDR
tVIDR
Program or Erase Command Sequence
CE#
WE#
tRRB
tRSP
RY/BY#
Figure 25.
January 27, 2003
Temporary Sector Unprotect Timing Diagram
Am29DS320G
45
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
VID
VIH
RESET#
SA, A6,
A1, A0
Valid*
Valid*
Sector/Sector Block Protect or Unprotect
Data
60h
60h
Valid*
Verify
40h
Status
Sector/Sector Block Protect: 150 µs,
Sector/Sector Block Unprotect: 15 ms
1 µs
CE#
WE#
OE#
* For sector protect, A6 = 0, A1 = 1, A0 = 0. For sector unprotect, A6 = 1, A1 = 1, A0 = 0.
Figure 26.
46
Sector/Sector Block Protect and Unprotect Timing Diagram
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
Alternate CE# Controlled Erase and Program Operations
Parameter
Speed Options
JEDEC
Std
Description
70
90
120
Unit
tAVAV
tWC
Write Cycle Time (Note 1)
Min
70
90
120
ns
tAVWL
tAS
Address Setup Time
Min
tELAX
tAH
Address Hold Time
Min
45
50
65
ns
tDVEH
tDS
Data Setup Time
Min
30
50
65
ns
tEHDX
tDH
Data Hold Time
Min
0
ns
tGHEL
tGHEL
Read Recovery Time Before Write
(OE# High to WE# Low)
Min
0
ns
tWLEL
tWS
WE# Setup Time
Min
0
ns
tEHWH
tWH
WE# Hold Time
Min
0
ns
tELEH
tCP
CE# Pulse Width
Min
36
50
65
ns
tEHEL
tCPH
CE# Pulse Width High
Min
25
30
45
ns
tWHWH1
tWHWH1
Programming Operation
(Note 2)
tWHWH1
tWHWH1
tWHWH2
tWHWH2
0
ns
Byte
Typ
5
Word
Typ
7
Accelerated Programming Operation,
Word or Byte (Note 2)
Typ
4
µs
Sector Erase Operation (Note 2)
Typ
0.4
sec
µs
Notes:
1. Not 100% tested.
2. See the “Erase And Programming Performance” section for more information.
January 27, 2003
Am29DS320G
47
A D V A N C E
I N F O R M A T I O N
AC CHARACTERISTICS
555 for program
2AA for erase
PA for program
SA for sector erase
555 for chip erase
Data# Polling
Addresses
PA
tWC
tAS
tAH
tWH
WE#
tGHEL
OE#
tWHWH1 or 2
tCP
CE#
tWS
tCPH
tBUSY
tDS
tDH
DQ7#
Data
tRH
A0 for program
55 for erase
DOUT
PD for program
30 for sector erase
10 for chip erase
RESET#
RY/BY#
Notes:
1. Figure indicates last two bus cycles of a program or erase operation.
2. PA = program address, SA = sector address, PD = program data.
3. DQ7# is the complement of the data written to the device. DOUT is the data written to the device.
4. Waveforms are for the word mode.
Figure 27.
48
Alternate CE# Controlled Write (Erase/Program) Operation Timings
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
ERASE AND PROGRAMMING PERFORMANCE
Parameter
Typ (Note 1)
Max (Note 2)
Unit
Comments
Sector Erase Time
0.4
5
sec
Chip Erase Time
28
Excludes 00h programming
prior to erasure (Note 4)
Byte Program Time
5
150
µs
Accelerated Byte/Word Program Time
4
120
µs
Word Program Time
7
210
µs
Byte Mode
21
63
Word Mode
14
42
Chip Program Time
(Note 3)
sec
Excludes system level
overhead (Note 5)
sec
Notes:
1. Typical program and erase times assume the following conditions: 25°C, 3.0 V VCC, 1,000,000 cycles. Additionally,
programming typicals assume checkerboard pattern.
2. Under worst case conditions of 90°C, VCC = 2.7 V (3.0 V for regulated devices), 1,000,000 cycles.
3. The typical chip programming time is considerably less than the maximum chip programming time listed, since most bytes
program faster than the maximum program times listed.
4. In the pre-programming step of the Embedded Erase algorithm, all bytes are programmed to 00h before erasure.
5. System-level overhead is the time required to execute the two- or four-bus-cycle sequence for the program command. See Table
13 for further information on command definitions.
6. The device has a minimum erase and program cycle endurance of 1,000,000 cycles.
LATCHUP CHARACTERISTICS
Description
Min
Max
Input voltage with respect to VSS on all pins except I/O pins
(including A9, OE#, and RESET#)
–1.0 V
11.0 V
Input voltage with respect to VSS on all I/O pins
–0.5 V
VCC + 0.5 V
–100 mA
+100 mA
VCC Current
Note: Includes all pins except VCC. Test conditions: VCC = 3.0 V, one pin at a time.
TSOP AND SO PIN CAPACITANCE
Parameter
Symbol
Parameter Description
Test Setup
Typ
Max
Unit
CIN
Input Capacitance
VIN = 0
6
7.5
pF
COUT
Output Capacitance
VOUT = 0
8.5
12
pF
CIN2
Control Pin Capacitance
VIN = 0
8
10
pF
Notes:
1. Sampled, not 100% tested.
2. Test conditions TA = 25°C, f = 1.0 MHz.
DATA RETENTION
Parameter Description
Test Conditions
Min
Unit
150°C
10
Years
125°C
20
Years
Minimum Pattern Data Retention Time
January 27, 2003
Am29DS320G
49
A D V A N C E
I N F O R M A T I O N
PHYSICAL DIMENSIONS
FBD048—Fine-Pitch Ball Grid Array, 6 x 12 mm
Dwg rev AG; 7/2000
FBD 048
6.00 mm x 12.00 mm
PACKAGE
1.20
0.20
0.94
0.84
12.00 BSC
6.00 BSC
5.60 BSC
4.00 BSC
8
6
0.25
48
0.30 0.35
0.80 BSC
0.40 BSC
50
Am29DS320G
January 27, 2003
A D V A N C E
I N F O R M A T I O N
PHYSICAL DIMENSIONS
TS 048—Thin Small Outline Package
Dwg rev AA; 10/99
January 27, 2003
Am29DS320G
51
A D V A N C E
I N F O R M A T I O N
REVISION SUMMARY
Revision A (May 14, 2002)
Byte/Word Program Command Sequence, Sector
Erase Command Sequence, and Chip Erase Command Sequence
Initial release.
Revision A+1 (January 3, 2003)
Noted that the SecSi Sector, autoselect, and CFI
functions are unavailable when a program or erase
operation is in progress.
Customer Lockable: SecSi Sector NOT
Programmed or Protected at the factory.
Added second bullet, SecSi sector-protect verify text
and figure 3.
Common Flash Memory Interface (CFI)
SecSi Sector Flash Memory Region, and Enter
SecSi Sector/Exit SecSi Sector Command
Sequence
Table 13. Command Definitions
Noted that the ACC function and unlock bypass modes
are not available when the SecSi sector is enabled.
Changed CFI website address.
Corrected the number of cycles of the Device ID from
4 to 6.
Trademarks
Copyright © 2002 Advanced Micro Devices, Inc. All rights reserved.
AMD, the AMD logo, and combinations thereof are registered trademarks of Advanced Micro Devices, Inc.
ExpressFlash is a trademark of Advanced Micro Devices, Inc.
Product names used in this publication are for identification purposes only and may be trademarks of their respective companies.
52
Am29DS320G
January 27, 2003
Sales Offices and Representatives
North America
ALABAMA ...........................................................................(256) 830-9192
ARIZONA ............................................................................(602) 242-4400
CALIFORNIA,
West Lake Village ..........................................................(805) 496-3992
Irvine ..............................................................................(949) 450-7500
Los Angeles....................................................................(805) 496-3992
Pleasanton .....................................................................(925) 416-8150
Sacramento (Cool).........................................................(530) 886-0945
San Diego ......................................................................(858) 566-6414
San Jose ........................................................................(408) 922-0300
CANADA (Toronto)..............................................................(905) 831-6226
COLORADO .......................................................................(303) 741-2900
CONNECTICUT..................................................................(203) 264-7800
FLORIDA,
Clearwater......................................................................(727) 793-0055
Miami (Lakes) .................................................................(305) 820-1113
GEORGIA ...........................................................................(770) 814-0224
ILLINOIS,
Chicago ..........................................................................(630) 773-4422
Mundelein.......................................................................(847) 837-0439
MASSACHUSETTS ............................................................(781) 213-6400
MICHIGAN ..........................................................................(248) 471-6294
MINNESOTA.......................................................................(612) 745-0005
NEW JERSEY,
Chatham.........................................................................(973) 701-1777
Cherry Hill ......................................................................(856) 662-2900
Parsippany .....................................................................(973) 299-0002
NEW YORK ........................................................................(716) 425-8050
NORTH CAROLINA............................................................(919) 840-8080
OREGON ............................................................................(503) 245-0080
PENNSYLVANIA .................................................................(215) 340-1187
SOUTH DAKOTA................................................................(605) 692-5777
TEXAS,
Austin .............................................................................(512) 346-7830
Dallas .............................................................................(972) 985-1344
Houston..........................................................................(281) 376-8084
VIRGINIA ............................................................................(703) 736-9568
International
AUSTRALIA, North Ryde ...........TEL.............................(61) 2-88-777-222
BELGIUM, Antwerpen ................TEL..............................(32) 3-2-48-43-00
BRAZIL, San Paulo ....................TEL ............................(55) 11-5501-2105
CHINA,
Beijing....................................TEL ............................(86) 10-6510-2188
Shanghai................................TEL ............................(86) 21-635-00838
Shenzhen...............................TEL ............................(86) 755-246-1550
FINLAND, Helsinki .....................TEL..................................(358) 881-3117
FRANCE, Paris ..........................TEL.............................(33)-1-49-75-1010
GERMANY,
Bad Homburg ........................TEL ...............................(49)-6172-92670
Munich ...................................TEL .................................(49)-89-450530
HONG KONG, Causeway Bay ...TEL ..............................(85) 2-2956-0388
ITALY, Milan................................TEL ...................................(39)-2-381961
INDIA, New Delhi .......................TEL ..............................(91) 11-623-8620
JAPAN,
Osaka ....................................TEL ..............................(81) 6-6243-3250
Tokyo .....................................TEL ..............................(81) 3-3346-7600
KOREA, Seoul............................TEL ..............................(82) 2-3468-2600
SINGAPORE, Singapore............TEL...............................(65) 6-337-7-033
SWITZERLAND, Geneva ...........TEL ..............................(41) 22-788-0251
SWEDEN, Stockholm .................TEL............................(46) 8-562-5-40-00
TAIWAN, Taipei...........................TEL ............................(886) 2-8773-1555
UNITED KINGDOM,
Frimley ..................................TEL .............................(44) 1276-803100
Haydcock ..............................TEL .............................(44) 1942-272888
Representatives in U.S. and Canada
ARIZONA,
Tempe - Centaur ............................................................(480) 839-2320
CALIFORNIA,
Calabasas - Centaur ......................................................(818) 878-5800
Irvine - Centaur..............................................................(949) 261-2123
San Diego - Centaur......................................................(858) 278-4950
Santa Clara - Fourfront. ................................................(408) 350-4800
CANADA,
Burnaby, B.C. - Davetek Marketing...............................(604) 430-3680
Calgary, Alberta - Davetek Marketing............................(403) 283-3577
Kanata, Ontario - J-Squared Tech.................................(613) 592-9540
Mississauga, Ontario - J-Squared Tech. .......................(905) 672-2030
St Laurent, Quebec - J-Squared Tech...........................(514) 747-1211
COLORADO,
Golden - Compass Marketing .......................................(303) 277-0456
FLORIDA,
Melbourne - Marathon Technical Sales.........................(321) 728-7706
Ft. Lauderdale - Marathon Technical Sales ..................(954) 527-4949
Orlando - Marathon Technical Sales.............................(407) 872-5775
St. Petersburg - Marathon Technical Sales...................(727) 894-3603
GEORGIA,
Duluth - Quantum Marketing .........................................(678) 584-1128
ILLINOIS,
Skokie - Industrial Reps, Inc. ........................................(847) 967-8430
INDIANA,
Kokomo - SAI ................................................................(765) 457-7241
IOWA,
Cedar Rapids - Lorenz Sales........................................(319) 294-1000
KANSAS,
Lenexa - Lorenz Sales ..................................................(913) 469-1312
MASSACHUSETTS,
Burlington - Synergy Associates ...................................(781) 238-0870
MICHIGAN,
Brighton - SAI................................................................(810) 227-0007
MINNESOTA,
St. Paul - Cahill, Schmitz & Cahill, Inc. .........................(651) 699-0200
MISSOURI,
St. Louis - Lorenz Sales ................................................(314) 997-4558
NEW JERSEY,
Mt. Laurel - SJ Associates ............................................(856) 866-1234
NEW YORK,
Buffalo - Nycom, Inc. .....................................................(716) 741-7116
East Syracuse - Nycom, Inc..........................................(315) 437-8343
Pittsford - Nycom, Inc....................................................(716) 586-3660
Rockville Centre - SJ Associates ..................................(516) 536-4242
NORTH CAROLINA,
Raleigh - Quantum Marketing .......................................(919) 846-5728
OHIO,
Middleburg Hts - Dolfuss Root & Co............................ (440) 816-1660
Powell - Dolfuss Root & Co. ....................................... (614) 781-0725
Vandalia - Dolfuss Root & Co. ......................................(937) 898-9610
Westerville - Dolfuss Root & Co....................................(614) 523-1990
OREGON,
Lake Oswego - I Squared, Inc. .....................................(503) 670-0557
UTAH,
Murray - Front Range Marketing...................................(801) 288-2500
VIRGINIA,
Glen Burnie - Coherent Solution, Inc. ...........................(410) 761-2255
WASHINGTON,
Kirkland - I Squared, Inc................................................(425) 822-9220
WISCONSIN,
Pewaukee - Industrial Representatives.........................(262) 574-9393
Representatives in Latin America
ARGENTINA,
Capital Federal. Argentina- Latin/WW Rep. ...........(+54-11) 4373-0655
CHILE,
Santiago - LatinRep/WWRep. .....................................(+562) 264-0993
COLUMBIA,
Bogota - Dimser.............................................................(571) 410-4182
MEXICO,
Guadalajara - LatinRep/WW Rep..................................(523) 817-3900
Mexico, City - LatinRep/WW Rep..................................(525) 752-2727
Monterrey - LatinRep/WW Rep. ....................................(528) 369-6828
PUERTO RICO,
Boqueron - Infitronics. ...................................................(787) 851-6000
Advanced Micro Devices reserves the right to make changes in its product without notice in order to improve design or performance
characteristics. The performance characteristics listed in this document are guaranteed by specific tests, guard banding, design and other practices
common to the industry. For specific testing details, contact your local AMD sales representative. The company assumes no responsibility for the
use of any circuits described herein.
© 2002 Advanced Micro Devices, Inc.
One AMD Place, P.O. Box 3453, Sunnyvale, CA 94088-3453 408-732-2400
TWX 910-339-9280 TELEX 34-6306 800-538-8450 http://www.amd.com
Printed in USA
Similar pages