Am29F400B 4 Megabit (512 K x 8-Bit/256 K x 16-Bit) CMOS 5.0 Volt-only Boot Sector Flash Memory DISTINCTIVE CHARACTERISTICS ■ Single power supply operation — 5.0 volt-only operation for read, erase, and program operations — Minimizes system level requirements ■ Manufactured on 0.32 µm process technology — Compatible with 0.5 µm Am29F400 device ■ High performance — Access times as fast as 45 ns ■ Low power consumption (typical values at 5 MHz) ■ Embedded Algorithms — Embedded Erase algorithm automatically preprograms and erases the entire chip or any combination of designated sectors — Embedded Program algorithm automatically writes and verifies data at specified addresses ■ Minimum 1,000,000 program/erase cycles per sector guaranteed ■ 20-year data retention at 125°C — Reliable operation for the life of the system ■ Package option — 1 µA standby mode current — 48-pin TSOP — 20 mA read current (byte mode) — 44-pin SO — 28 mA read current (word mode) — Known Good Die (KGD) (see publication number 21258) — 30 mA program/erase current ■ Flexible sector architecture ■ Compatibility with JEDEC standards — One 16 Kbyte, two 8 Kbyte, one 32 Kbyte, and seven 64 Kbyte sectors (byte mode) — Pinout and software compatible with singlepower-supply Flash — One 8 Kword, two 4 Kword, one 16 Kword, and seven 32 Kword sectors (word mode) — Superior inadvertent write protection — Supports full chip erase — Sector Protection features: A hardware method of locking a sector to prevent any program or erase operations within that sector Sectors can be locked via programming equipment Temporary Sector Unprotect feature allows code changes in previously locked sectors ■ Top or bottom boot block configurations available ■ Data# Polling and toggle bits — Provides a software method of detecting program or erase operation completion ■ Ready/Busy# pin (RY/BY#) — Provides a hardware method of detecting program or erase cycle completion ■ Erase Suspend/Erase Resume — Suspends an erase operation to read data from, or program data to, a sector that is not being erased, then resumes the erase operation ■ Hardware reset pin (RESET#) — Hardware method to reset the device to reading array data This Data Sheet states AMD’s current technical specifications regarding the Products described herein. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Publication# 21505 Rev: E Amendment/0 Issue Date: November 15, 1999 GENERAL DESCRIPTION The Am29F400B is a 4 Mbit, 5.0 volt-only Flash memory organized as 524,288 bytes or 262,144 words. The device is offered in 44-pin SO and 48-pin TSOP packages. The device is also available in Known Good Die (KGD) form. For more information, refer to publication number 21258. The word-wide data (x16) appears on DQ15–DQ0; the byte-wide (x8) data appears on DQ7– DQ0. This device is designed to be programmed in-system with the standard system 5.0 volt VCC supply. A 12.0 V VPP is not required for write or erase operations. The device can also be programmed in standard EPROM programmers. This device is manufactured using AMD’s 0.32 µm process technology, and offers all the features and benefits of the Am29F400, which was manufactured using 0.5 µm process technology. The standard device offers access times of 45, 50, 55, 70, 90, 120, and 150 ns, allowing high speed microprocessors to operate without wait states. To eliminate bus contention the device has separate chip enable (CE#), write enable (WE#) and output enable (OE#) controls. The device requires only a single 5.0 volt power supply for both read and write functions. Internally generated and regulated voltages are provided for the program and erase operations. The device is entirely command set compatible with the JEDEC single-power-supply Flash standard. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine that controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the device is similar to reading from other Flash or EPROM devices. Device programming occurs by executing the program command sequence. This initiates the Embedded Program algorithm—an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Device erasure occurs by executing the erase command sequence. This initiates the Embedded 2 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Erase algorithm—an internal algorithm that automatically preprograms the array (if it is not already programmed) before executing the erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell margin. The host system can detect whether a program or erase operation is complete by observing the RY/BY# pin, or by reading the DQ7 (Data# Polling) and DQ6/DQ2 (toggle) status bits. After a program or erase cycle has been completed, the device is ready to read array data or accept another command. The sector erase architecture allows memory sectors to be erased and reprogrammed without affecting the data contents of other sectors. The device is fully erased when shipped from the factory. Hardware data protection measures include a low VCC detector that automatically inhibits write operations during power transitions. The hardware sector protection feature disables both program and erase operations in any combination of the sectors of memory. This can be achieved via programming equipment. The Erase Suspend feature enables the user to put erase on hold for any period of time to read data from, or program data to, any sector that is not selected for erasure. True background erase can thus be achieved. The hardware RESET# pin terminates any operation in progress and resets the internal state machine to reading array data. The RESET# pin may be tied to the system reset circuitry. A system reset would thus also reset the device, enabling the system microprocessor to read the boot-up firmware from the Flash memory. The system can place the device into the standby mode. Power consumption is greatly reduced in this mode. AMD’s Flash technology combines years of Flash memory manufacturing experience to produce the highest levels of quality, reliability and cost effectiveness. The device electrically erases all bits within a sector simultaneously via Fowler-Nordheim tunneling. The data is programmed using hot electron injection. Am29F400B PRODUCT SELECTOR GUIDE Family Part Number Speed Option Am29F400B VCC = 5.0 V ± 5% -45 -50 -55 VCC = 5.0 V ± 10% -55 -70 -90 -120 -150 Max access time, ns (tACC) 45 50 55 70 90 120 150 Max CE# access time, ns (tCE) 45 50 55 70 90 120 150 Max OE# access time, ns (tOE) 30 30 30 30 35 50 55 Note: See “AC Characteristics” for full specifications. BLOCK DIAGRAM DQ0–DQ15 (A-1) RY/BY# VCC Sector Switches VSS Erase Voltage Generator RESET# WE# BYTE# Input/Output Buffers State Control Command Register PGM Voltage Generator Chip Enable Output Enable Logic CE# OE# VCC Detector Address Latch STB Timer A0–A17 STB Data Latch Y-Decoder Y-Gating X-Decoder Cell Matrix 21505E-1 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 3 CONNECTION DIAGRAMS This device is also available in Known Good Die (KGD) form. Refer to publication number 21258 for more information. A15 A14 A13 A12 A11 A10 A9 A8 NC NC WE# RESET# NC NC RY/BY# NC A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A16 BYTE# VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# VSS CE# A0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48-Pin TSOP—Standard Pinout 48-Pin TSOP—Reverse Pinout 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A16 BYTE# VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# VSS CE# A0 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A15 A14 A13 A12 A11 A10 A9 A8 NC NC WE# RESET# NC NC RY/BY# NC A17 A7 A6 A5 A4 A3 A2 A1 21505E-2 4 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B CONNECTION DIAGRAMS This device is also available in Known Good Die (KGD) form. Refer to publication number 21258 for more information. NC RY/BY# A17 A7 A6 A5 A4 A3 A2 A1 A0 CE# VSS OE# DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 SO RESET# WE# A8 A9 A10 A11 A12 A13 A14 A15 A16 BYTE# VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC 21505E-3 PIN CONFIGURATION A0–A17 LOGIC SYMBOL = 18 addresses DQ0–DQ14 = 15 data inputs/outputs DQ15/A-1 = DQ15 (data input/output, word mode), A-1 (LSB address input, byte mode) BYTE# = Selects 8-bit or 16-bit mode CE# = Chip enable OE# = Output enable WE# = Write enable RESET# = Hardware reset pin, active low RY/BY# = Ready/Busy# output VCC = +5.0 V single power supply (see Product Selector Guide for device speed ratings and voltage supply tolerances) VSS = Device ground NC = Pin not connected internally Powered by ICminer.com Electronic-Library Service CopyRight 2003 18 A0–A17 16 or 8 DQ0–DQ15 (A-1) CE# OE# WE# RESET# BYTE# RY/BY# 21505E-4 Am29F400B 5 ORDERING INFORMATION Standard Products AMD standard products are available in several packages and operating ranges. The order number (Valid Combination) is formed by a combination of the elements below. Am29F400B T -45 E C OPTIONAL PROCESSING Blank = Standard Processing 0 = VCC = 5.0 V ± 10%, 55 ns device only (Contact an AMD representative for more information) TEMPERATURE RANGE C = Commercial (0°C to +70°C) I = Industrial (–40°C to +85°C) E = Extended (–55°C to +125°C) PACKAGE TYPE E = 48-Pin Thin Small Outline Package (TSOP) Standard Pinout (TS 048) F = 48-Pin Thin Small Outline Package (TSOP) Reverse Pinout (TSR048) S = 44-Pin Small Outline Package (SO 044) This device is also available in Known Good Die (KGD) form. See publication number 21258 for more information. SPEED OPTION See Product Selector Guide and Valid Combinations BOOT CODE SECTOR ARCHITECTURE T = Top sector B = Bottom sector DEVICE NUMBER/DESCRIPTION Am29F400B 4 Megabit (512 K x 8-Bit/256 K x 16-Bit) CMOS Flash Memory 5.0 Volt-only Read, Program and Erase Voltage Range Valid Combinations AM29F400BT-45, AM29F400BB-45, AM29F400BT-50, AM29F400BB-50 AM29F400BT-55, AM29F400BB-55 AM29F400BT-55, AM29F400BB-55 EC, EI, FC, FI, SC, SI 5.0 V ± 5% Valid Combinations Valid Combinations list configurations planned to be supported in volume for this device. Consult the local AMD sales office to confirm availability of specific valid combinations and to check on newly released combinations. EC, EI, EE, FC, FI, FE, SC, SI, SE EC0, EI0, EE0, FC0, FI0, FE0, SC0, SI0, SE0 AM29F400BT-70, AM29F400BB-70 AM29F400BT-90, AM29F400BB-90 AM29F400BT-120, AM29F400BB-120 5.0 V ± 10% EC, EI, EE, FC, FI, FE, SC, SI, SE AM29F400BT-150, AM29F400BB-150 6 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B DEVICE BUS OPERATIONS This section describes the requirements and use of the device bus operations, which are initiated through the internal command register. The command register itself does not occupy any addressable memory location. The register is composed of latches that store the commands, along with the address and data information needed to execute the command. The contents of Table 1. the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. Table 1 lists the device bus operations, the inputs and control levels they require, and the resulting output. The following subsections describe each of these operations in further detail. Am29F400B Device Bus Operations DQ8–DQ15 Operation Read Write CE# OE# WE# RESET# A0–A17 DQ0–DQ7 BYTE# = VIH L L H H AIN DOUT DOUT High-Z L H L H AIN DIN DIN High-Z X High-Z High-Z High-Z BYTE# = VIL VCC ± 0.5 V X X VCC ± 0.5 V H X X H X High-Z High-Z High-Z Output Disable L H H H X High-Z High-Z High-Z Hardware Reset X X X L X High-Z High-Z High-Z Temporary Sector Unprotect (See Note) X X X VID AIN DIN DIN X CMOS Standby TTL Standby Legend: L = Logic Low = VIL, H = Logic High = VIH, VID = 12.0 ± 0.5 V, X = Don’t Care, DIN = Data In, DOUT = Data Out, AIN = Address In Note:See the sections onSector Group Protection and Temporary Sector Unprotect for more information. Word/Byte Configuration The BYTE# pin controls whether the device data I/O pins DQ15–DQ0 operate in the byte or word configuration. If the BYTE# pin is set at logic ‘1’, the device is in word configuration, DQ15–DQ0 are active and controlled by CE# and OE#. If the BYTE# pin is set at logic ‘0’, the device is in byte configuration, and only data I/O pins DQ0–DQ7 are active and controlled by CE# and OE#. The data I/O pins DQ8–DQ14 are tri-stated, and the DQ15 pin is used as an input for the LSB (A-1) address function. Requirements for Reading Array Data To read array data from the outputs, the system must drive the CE# and OE# pins to VIL. CE# is the power control and selects the device. OE# is the output control and gates array data to the output pins. WE# should remain at V IH . The BYTE# pin determines whether the device outputs array data in words or bytes. The internal state machine is set for reading array data upon device power-up, or after a hardware reset. This ensures that no spurious alteration of the memory content occurs during the power transition. No command is necessary in this mode to obtain array data. Standard microprocessor read cycles that assert valid addresses on the device address inputs produce valid data on the device data outputs. The device Powered by ICminer.com Electronic-Library Service CopyRight 2003 remains enabled for read access until the command register contents are altered. See “Reading Array Data” for more information. Refer to the AC Read Operations table for timing specifications and to Figure 9 for the timing diagram. ICC1 in the DC Characteristics table represents the active current specification for reading array data. Writing Commands/Command Sequences To write a command or command sequence (which includes programming data to the device and erasing sectors of memory), the system must drive WE# and CE# to VIL, and OE# to VIH. For program operations, the BYTE# pin determines whether the device accepts program data in bytes or words. Refer to “Word/Byte Configuration” for more information. An erase operation can erase one sector, multiple sectors, or the entire device. Tables 2 and 3 indicate the address space that each sector occupies. A “sector address” consists of the address bits required to uniquely select a sector. The “Command Definitions” section has details on erasing a sector or the entire chip, or suspending/resuming the erase operation. After the system writes the autoselect command sequence, the device enters the autoselect mode. The system can then read autoselect codes from the Am29F400B 7 internal register (which is separate from the memory array) on DQ7–DQ0. Standard read cycle timings apply in this mode. Refer to the “Autoselect Mode” and “Autoselect Command Sequence” sections for more information. In the CMOS and TTL/NMOS-compatible DC Characteristics tables, ICC3 represents the standby current specification. ICC2 in the DC Characteristics table represents the active current specification for the write mode. The “AC Characteristics” section contains timing specification tables and timing diagrams for write operations. The RESET# pin provides a hardware method of resetting the device to reading array data. When the RESET# pin is driven low for at least a period of tRP, the device immediately terminates any operation in progress, tristates all output pins, and ignores all read/write commands for the duration of the RESET# pulse. The device also resets the internal state machine to reading array data. The operation that was interrupted should be reinitiated once the device is ready to accept another command sequence, to ensure data integrity. Program and Erase Operation Status During an erase or program operation, the system may check the status of the operation by reading the status bits on DQ7–DQ0. Standard read cycle timings and ICC read specifications apply. Refer to “The Erase Resume command is valid only during the Erase Suspend mode.” for more information, and to “AC Characteristics” for timing diagrams. Standby Mode When the system is not reading or writing to the device, it can place the device in the standby mode. In this mode, current consumption is greatly reduced, and the outputs are placed in the high impedance state, independent of the OE# input. The device enters the CMOS standby mode when the CE# and RESET# pins are both held at VCC ± 0.5 V. (Note that this is a more restricted voltage range than VIH.) The device enters the TTL standby mode when CE# and RESET# pins are both held at VIH. The device requires standard access time (tCE) for read access when the device is in either of these standby modes, before it is ready to read data. The device also enters the standby mode when the RESET# pin is driven low. Refer to the next section, “RESET#: Hardware Reset Pin”. If the device is deselected during erasure or programming, the device draws active current until the operation is completed. RESET#: Hardware Reset Pin Current is reduced for the duration of the RESET# pulse. When RESET# is held at VIL, the device enters the TTL standby mode; if RESET# is held at VSS±0.5 V, the device enters the CMOS standby mode. The RESET# pin may be tied to the system reset circuitry. A system reset would thus also reset the Flash memory, enabling the system to read the boot-up firmware from the Flash memory. If RESET# is asserted during a program or erase operation, the RY/BY# pin remains a “0” (busy) until the internal reset operation is complete, which requires a time of tREADY (during Embedded Algorithms). The system can thus monitor RY/BY# to determine whether the reset operation is complete. If RESET# is asserted when a program or erase operation is not executing (RY/BY# pin is “1”), the reset operation is completed within a time of tREADY (not during Embedded Algorithms). The system can read data t RH after the RESET# pin returns to VIH. Refer to the AC Characteristics tables for RESET# parameters and to Figure 10 for the timing diagram. Output Disable Mode When the OE# input is at VIH, output from the device is disabled. The output pins are placed in the high impedance state. 8 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B Table 2. Am29F400BT Top Boot Block Sector Address Table Address Range (in hexadecimal) Sector A17 A16 A15 A14 A13 A12 Sector Size (Kbytes/ Kwords) SA0 0 0 0 X X X 64/32 00000h–0FFFFh 00000h–07FFFh SA1 0 0 1 X X X 64/32 10000h–1FFFFh 08000h–0FFFFh SA2 0 1 0 X X X 64/32 20000h–2FFFFh 10000h–17FFFh SA3 0 1 1 X X X 64/32 30000h–3FFFFh 18000h–1FFFFh SA4 1 0 0 X X X 64/32 40000h–4FFFFh 20000h–27FFFh SA5 1 0 1 X X X 64/32 50000h–5FFFFh 28000h–2FFFFh SA6 1 1 0 X X X 64/32 60000h–6FFFFh 30000h–37FFFh SA7 1 1 1 0 X X 32/16 70000h–77FFFh 38000h–3BFFFh SA8 1 1 1 1 0 0 8/4 78000h–79FFFh 3C000h–3CFFFh SA9 1 1 1 1 0 1 8/4 7A000h–7BFFFh 3D000h–3DFFFh SA10 1 1 1 1 1 X 16/8 7C000h–7FFFFh 3E000h–3FFFFh Table 3. (x8) Address Range (x16) Address Range Am29F400BB Bottom Boot Block Sector Address Table Address Range (in hexadecimal) Sector A17 A16 A15 A14 A13 A12 Sector Size (Kbytes/Kwords) (x8) Address Range (x16) Address Range SA0 0 0 0 0 0 X 16/8 00000h–03FFFh 00000h–01FFFh SA1 0 0 0 0 1 0 8/4 04000h–05FFFh 02000h–02FFFh SA2 0 0 0 0 1 1 8/4 06000h–07FFFh 03000h–03FFFh SA3 0 0 0 1 X X 32/16 08000h–0FFFFh 04000h–07FFFh SA4 0 0 1 X X X 64/32 10000h–1FFFFh 08000h–0FFFFh SA5 0 1 0 X X X 64/32 20000h–2FFFFh 10000h–17FFFh SA6 0 1 1 X X X 64/32 30000h–3FFFFh 18000h–1FFFFh SA7 1 0 0 X X X 64/32 40000h–4FFFFh 20000h–27FFFh SA8 1 0 1 X X X 64/32 50000h–5FFFFh 28000h–2FFFFh SA9 1 1 0 X X X 64/32 60000h–6FFFFh 30000h–37FFFh SA10 1 1 1 X X X 64/32 70000h–7FFFFh 38000h–3FFFFh Note: Address range is A17:A-1 in byte mode and A17:A0 in word mode.See the “Word/Byte Configuration” section for more information. Autoselect Mode The autoselect mode provides manufacturer and device identification, and sector protection verification, through identifier codes output on DQ7–DQ0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires VID (11.5 V to 12.5 V) on address pin A9. Address pins A6, A1, and A0 must be as shown in Table 4. In addition, when verifying sector protection, Powered by ICminer.com Electronic-Library Service CopyRight 2003 the sector address must appear on the appropriate highest order address bits (see Tables 2 and 3). Table 4 shows the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on DQ7–DQ0. To access the autoselect codes in-system, the host system can issue the autoselect command via the command register, as shown in Table 5. This method does not require VID. See “Command Definitions” for details on using the autoselect mode. Am29F400B 9 Table 4. Description Mode Am29F400B Autoselect Codes (High Voltage Method) A17 A11 to to WE# A12 A10 CE# OE# Manufacturer ID: AMD L L H Device ID: Am29F400B (Top Boot Block) Word L L H Byte L L H Device ID: Am29F400B (Bottom Boot Block) Word L L H Byte L L H L L H A6 A5 to A2 A1 A0 DQ8 to DQ15 DQ7 to DQ0 X 01h 22h 23h X 23h 22h ABh X ABh X 01h (protected) X 00h (unprotected) X X VID X L X L L X X VID X L X L H X Sector Protection Verification A9 A8 to A7 SA X X VID VID X X L L X X L H H L L = Logic Low = VIL, H = Logic High = VIH, SA = Sector Address, X = Don’t care. Sector Protection/Unprotection The hardware sector protection feature disables both program and erase operations in any sector. The hardware sector unprotection feature re-enables both program and erase operations in previously protected sectors. START RESET# = VID (Note 1) Sector protection/unprotection must be implemented using programming equipment. The procedure requires a high voltage (VID ) on address pin A9 and OE#. Details on this method are provided in a supplement, publication number 20185. Contact an AMD representative to obtain a copy of this document. Perform Erase or Program Operations RESET# = VIH The device is shipped with all sectors unprotected. AMD offers the option of programming and protecting sectors at its factory prior to shipping the device through AMD’s ExpressFlash™ Service. Contact an AMD representative for details. Temporary Sector Unprotect Completed (Note 2) It is possible to determine whether a sector is protected or unprotected. See “Autoselect Mode” for details. Temporary Sector Unprotect This feature allows temporary unprotection of previously protected sectors to change data in-system. The Sector Unprotect mode is activated by setting the RESET# pin to VID. During this mode, formerly protected sectors can be programmed or erased by selecting the sector addresses. Once VID is removed from the RESET# pin, all the previously protected sectors are protected again. Figure 1 shows the algorithm, and Figure 18 shows the timing diagrams, for this feature. 10 Powered by ICminer.com Electronic-Library Service CopyRight 2003 21505E-5 Notes: 1. All protected sectors unprotected. 2. All previously protected sectors are protected once again. Figure 1. Temporary Sector Unprotect Operation Hardware Data Protection The command sequence requirement of unlock cycles for programming or erasing provides data protection against inadvertent writes (refer to Table 5 for command definitions). In addition, the following hard- Am29F400B ware data protection measures prevent accidental erasure or programming, which might otherwise be caused by spurious system level signals during VCC power-up and power-down transitions, or from system noise. Low VCC Write Inhibit When V CC is less than V LKO , the device does not accept any write cycles. This protects data during VCC power-up and power-down. The command register and all internal program/erase circuits are disabled, and the device resets. Subsequent writes are ignored until VCC is greater than VLKO. The system must provide the proper signals to the control pins to prevent unintentional writes when VCC is greater than VLKO. Write Pulse “Glitch” Protection Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle. Logical Inhibit Write cycles are inhibited by holding any one of OE# = VIL, CE# = VIH or WE# = VIH. To initiate a write cycle, CE# and WE# must be a logical zero while OE# is a logical one. Power-Up Write Inhibit If WE# = CE# = VIL and OE# = VIH during power up, the device does not accept commands on the rising edge of WE#. The internal state machine is automatically reset to reading array data on power-up. COMMAND DEFINITIONS Writing specific address and data commands or sequences into the command register initiates device operations. Table 5 defines the valid register command sequences. Writing incorrect address and data values or writing them in the improper sequence resets the device to reading array data. All addresses are latched on the falling edge of WE# or CE#, whichever happens later. All data is latched on the rising edge of WE# or CE#, whichever happens first. Refer to the appropriate timing diagrams in the “AC Characteristics” section. Reading Array Data The device is automatically set to reading array data after device power-up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. After the device accepts an Erase Suspend command, the device enters the Erase Suspend mode. The system can read array data using the standard read timings, except that if it reads at an address within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Erase Suspend mode, the system may once again read array data with the same exception. See “Erase Suspend/Erase Resume Commands” for more information on this mode. The system must issue the reset command to reenable the device for reading array data if DQ5 goes high, or while in the autoselect mode. See the “Reset Command” section, next. See also “Requirements for Reading Array Data” in the “Device Bus Operations” section for more information. The Read Operations table provides the read parameters, and Figure 9 shows the timing diagram. Reset Command Writing the reset command to the device resets the device to reading array data. Address bits are don’t care for this command. The reset command may be written between the sequence cycles in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to reading array data (also applies to programming in Erase Suspend mode). Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data (also applies to autoselect during Erase Suspend). If DQ5 goes high during a program or erase operation, writing the reset command returns the device to reading array data (also applies during Erase Suspend). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manufacturer and devices codes, and determine whether or not a sector is protected. Table 5 shows the address and data requirements. This method is an alternative to that shown in Table 4, which is intended for PROM programmers and requires VID on address bit A9. The autoselect command sequence is initiated by writing two unlock cycles, followed by the autoselect Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 11 command. The device then enters the autoselect mode, and the system may read at any address any number of times, without initiating another command sequence. START A read cycle at address XX00h or retrieves the manufacturer code. A read cycle at address XX01h in word mode (or 02h in byte mode) returns the device code. A read cycle containing a sector address (SA) and the address 02h in word mode (or 04h in byte mode) returns 01h if that sector is protected, or 00h if it is unprotected. Refer to Tables 2 and 3 for valid sector addresses. Write Program Command Sequence Data Poll from System Embedded Program algorithm in progress The system must write the reset command to exit the autoselect mode and return to reading array data. Word/Byte Program Command Sequence Verify Data? The system may program the device by word or byte, depending on the state of the BYTE# pin. Programming is a four-bus-cycle operation. The program command sequence is initiated by writing two unlock write cycles, followed by the program set-up command. The program address and data are written next, which in turn initiate the Embedded Program algorithm. The system is not required to provide further controls or timings. The device automatically provides internally generated program pulses and verify the programmed cell margin. Table 5 shows the address and data r e qu i r em e n ts fo r th e b y te p ro g ra m c o m m a n d sequence. No Yes Increment Address No Last Address? Yes Programming Completed 21505E-5 When the Embedded Program algorithm is complete, the device then returns to reading array data and addresses are no longer latched. The system can determine the status of the program operation by using DQ7, DQ6, or RY/BY#. See “The Erase Resume command is valid only during the Erase Suspend mode.” for information on these status bits. Note: See Table 5 for program command sequence. Any commands written to the device during the Embedded Program Algorithm are ignored. Note that a hardware reset immediately terminates the programm i ng op er at io n. T h e By te Pr o gr am co mm a n d sequence should be reinitiated once the device has reset to reading array data, to ensure data integrity. Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. Table 5 shows the address and data requirements for the chip erase command sequence. Programming is allowed in any sequence and across sector boundaries. A bit cannot be programmed from a “0” back to a “1”. Attempting to do so may halt the operation and set DQ5 to “1”, or cause the Data# Polling algorithm to indicate the operation was successful. However, a succeeding read will show that the data is still “0”. Only erase operations can convert a “0” to a “1”. 12 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Figure 2. Program Operation Chip Erase Command Sequence A ny com m ands w ritten to the ch ip d uring th e Embedded Erase algorithm are ignored. Note that a hardware reset during the chip erase operation immediately terminates the operation. The Chip Erase command sequence should be reinitiated once the Am29F400B device has returned to reading array data, to ensure data integrity. The system can determine the status of the erase operation by using DQ7, DQ6, DQ2, or RY/BY#. See “The Erase Resume command is valid only during the Erase Suspend mode.” for information on these status bits. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. Figure 3 illustrates the algorithm for the erase operation. See the “Erase/Program Operations” tables in “AC Characteristics” for parameters, and to Figure 14 for timing diagrams. Sector Erase Command Sequence Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the address of the sector to be erased, and the sector erase command. Table 5 shows the address and data requirements for the sector erase command sequence. The device does not require the system to preprogram the memory prior to erase. The Embedded Erase algorithm automatically programs and verifies the sector for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. After the command sequence is written, a sector erase time-out of 50 µs begins. During the time-out period, additional sector addresses and sector erase commands may be written. Loading the sector erase buffer may be done in any sequence, and the number of sectors may be from one sector to all sectors. The time between these additional cycles must be less than 50 µs, otherwise the last address and command might not be accepted, and erasure may begin. It is recommended that processor interrupts be disabled during this time to ensure all commands are accepted. The interrupts can be re-enabled after the last Sector Erase command is written. If the time between additional sector erase commands can be assumed to be less than 50 µs, the system need not monitor DQ3. Any command other than Sector Erase or Erase Suspend during the time-out period resets the device to reading array data. The system must rewrite the command sequence and any additional sector addresses and commands. The system can monitor DQ3 to determine if the sector erase timer has timed out. (See the “DQ3: Sector Erase Timer” section.) The time-out begins from the rising edge of the final WE# pulse in the command sequence. Once the sector erase operation has begun, only the Erase Suspend command is valid. All other commands Powered by ICminer.com Electronic-Library Service CopyRight 2003 are ignored. Note that a hardware reset during the sector erase operation immediately terminates the operation. The Sector Erase command sequence should be reinitiated once the device has returned to reading array data, to ensure data integrity. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, DQ2, or RY/BY#. (Refer to “The Erase Resume command is valid only during the Erase Suspend mode.” for information on these status bits.) Figure 3 illustrates the algorithm for the erase operation. Refer to the “Erase/Program Operations” tables in the “AC Characteristics” section for parameters, and to Figure 14 for timing diagrams. Erase Suspend/Erase Resume Commands The Erase Suspend command allows the system to interrupt a sector erase operation and then read data from, or program data to, any sector not selected for erasure. This command is valid only during the sector erase operation, including the 50 µs time-out period during the sector erase command sequence. The Erase Suspend command is ignored if written during the chip erase operation or Embedded Program algorithm. Writing the Erase Suspend command during the Sector Erase time-out immediately terminates the time-out period and suspends the erase operation. Addresses are “don’t-cares” when writing the Erase Suspend command. When the Erase Suspend command is written during a sector erase operation, the device requires a maximum of 20 µs to suspend the erase operation. However, when the Erase Suspend command is written during the sector erase time-out, the device immediately terminates the time-out period and suspends the erase operation. After the erase operation has been suspended, the system can read array data from or program data to any sector not selected for erasure. (The device “erase suspends” all sectors selected for erasure.) Normal read and write timings and command definitions apply. Reading at any address within erase-suspended sectors produces status data on DQ7–DQ0. The system can use DQ7, or DQ6 and DQ2 together, to determine if a sector is actively erasing or is erase-suspended. See “The Erase Resume command is valid only during the Erase Suspend mode.” for information on these status bits. After an erase-suspended program operation is complete, the system can once again read array data within non-suspended sectors. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard program operation. Am29F400B 13 See “The Erase Resume command is valid only during the Erase Suspend mode.” for more information. START The system may also write the autoselect command sequence when the device is in the Erase Suspend mode. The device allows reading autoselect codes even at addresses within erasing sectors, since the codes are not stored in the memory array. When the device exits the autoselect mode, the device reverts to the Erase Suspend mode, and is ready for another valid operation. See “Autoselect Command Sequence” for more information. Write Erase Command Sequence Data Poll from System The system must write the Erase Resume command (address bits are “don’t care”) to exit the erase suspend mode and continue the sector erase operation. Further writes of the Resume command are ignored. Another Erase Suspend command can be written after the device has resumed erasing. No Embedded Erase algorithm in progress Data = FFh? Yes Erasure Completed 21505E-6 Notes: 1. See Table 5 for erase command sequence. 2. See “DQ3: Sector Erase Timer” for more information. Figure 3. 14 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B Erase Operation Table 5. Read (Note 6) Reset (Note 7) Autoselect (Note 8) Manufacturer ID Word Byte Device ID, Top Boot Block Word Device ID, Bottom Boot Block Word Byte Byte Addr Data 1 RA RD 1 XXX F0 4 4 4 Word Sector Protect Verify (Note 9) Chip Erase Sector Erase First 555 AAA 555 AAA 555 AAA 4 Word Byte Word Byte Word Byte Second AA AA AA 555 Byte Program Bus Cycles (Notes 2–5) Cycles Command Sequence (Note 1) Am29F400B Command Definitions 6 6 2AA 555 2AA 555 2AA 555 AA 555 AAA 555 AAA 555 AAA Third Data AAA 555 55 AAA 555 55 AAA 55 AA AA Erase Suspend (Note 10) 1 XXX B0 Erase Resume (Note 11) 1 XXX 30 2AA 555 2AA 555 2AA 555 Fourth Data Addr 90 90 90 555 AAA 555 55 AAA 555 55 AAA 555 55 AAA A0 80 80 Data X00 01 X01 2223 X02 23 X01 22AB X02 AB (SA) X02 XX00 (SA) X04 00 PA PD 90 555 AA Addr 555 55 2AA AAA 4 Addr 555 AAA 555 AAA Fifth Sixth Addr Data Addr Data XX01 01 AA AA 2AA 555 2AA 555 55 55 555 AAA SA 10 30 Legend: X = Don’t care PD = Data to be programmed at location PA. Data latches on the rising edge of WE# or CE# pulse, whichever happens first. RA = Address of the memory location to be read. SA = Address of the sector to be verified (in autoselect mode) or erased. Address bits A17–A12 uniquely select any sector. RD = Data read from location RA during read operation. PA = Address of the memory location to be programmed. Addresses latch on the falling edge of the WE# or CE# pulse, whichever happens later. Notes: 1. See Table 1 for description of bus operations. 8. The fourth cycle of the autoselect command sequence is a read cycle. 2. All values are in hexadecimal. 3. Except when reading array or autoselect data, all bus cycles are write operations. 4. Data bits DQ15–DQ8 are don’t cares for unlock and command cycles. 9. The data is 00h for an unprotected sector and 01h for a protected sector. See“Autoselect Command Sequence” for more information. 5. Address bits A17–A11 are don’t cares for unlock and command cycles, unless PA or SA required. 10. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode. The Erase Suspend command is valid only during a sector erase operation. 6. No unlock or command cycles required when reading array data. 11. The Erase Resume command is valid only during the Erase Suspend mode. 7. The Reset command is required to return to reading array data when device is in the autoselect mode, or if DQ5 goes high (while the device is providing status data). Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 15 WRITE OPERATION STATUS The device provides several bits to determine the status of a write operation: DQ2, DQ3, DQ5, DQ6, DQ7, and RY/BY#. Table 6 and the following subsections describe the functions of these bits. DQ7, RY/BY#, and DQ6 each offer a method for determining whether a program or erase operation is complete or in progress. These three bits are discussed first. Table 6 shows the outputs for Data# Polling on DQ7. Figure 4 shows the Data# Polling algorithm. START DQ7: Data# Polling The Data# Polling bit, DQ7, indicates to the host system whether an Embedded Algorithm is in progress or completed, or whether the device is in Erase Suspend. Data# Polling is valid after the rising edge of the final WE# pulse in the program or erase command sequence. During the Embedded Program algorithm, the device outputs on DQ7 the complement of the datum programmed to DQ7. This DQ7 status also applies to programming during Erase Suspend. When the Embedded Program algorithm is complete, the device outputs the datum programmed to DQ7. The system must provide the program address to read valid status information on DQ7. If a program address falls within a protected sector, Data# Polling on DQ7 is active for approximately 2 µs, then the device returns to reading array data. Read DQ7–DQ0 Addr = VA DQ7 = Data? No No When the system detects DQ7 has changed from the complement to true data, it can read valid data at DQ7– DQ0 on the following read cycles. This is because DQ7 may change asynchronously with DQ0–DQ6 while Output Enable (OE#) is asserted low. Figure 15, Data# Polling Timings (During Embedded Algorithms), in the “AC Characteristics” section illustrates this. 16 Powered by ICminer.com Electronic-Library Service CopyRight 2003 DQ5 = 1? Yes Read DQ7–DQ0 Addr = VA During the Embedded Erase algorithm, Data# Polling produces a “0” on DQ7. When the Embedded Erase algorithm is complete, or if the device enters the Erase Suspend mode, Data# Polling produces a “1” on DQ7. This is analogous to the complement/true datum output described for the Embedded Program algorithm: the erase function changes all the bits in a sector to “1”; prior to this, the device outputs the “complement,” or “0.” The system must provide an address within any of the sectors selected for erasure to read valid status information on DQ7. After an erase command sequence is written, if all sectors selected for erasing are protected, Data# Polling on DQ7 is active for approximately 100 µs, then the device returns to reading array data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected. Yes DQ7 = Data? Yes No FAIL PASS Notes: 1. VA = Valid address for programming. During a sector erase operation, a valid address is an address within any sector selected for erasure. During chip erase, a valid address is any non-protected sector address. 2. DQ7 should be rechecked even if DQ5 = “1” because DQ7 may change simultaneously with DQ5. Am29F400B 21505E-7 Figure 4. Data# Polling Algorithm RY/BY#: Ready/Busy# The RY/BY# is a dedicated, open-drain output pin that indicates whether an Embedded Algorithm is in progress or complete. The RY/BY# status is valid after the rising edge of the final WE# pulse in the command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a pull-up resistor to VCC. If the output is low (Busy), the device is actively erasing or programming. (This includes programming in the Erase Suspend mode.) If the output is high (Ready), the device is ready to read array data (including during the Erase Suspend mode), or is in the standby mode. Table 6 shows the outputs for RY/BY#. Figures 10, Figure 13 and Figure 14 shows RY/BY# for reset, program, and erase operations, respectively. DQ6: Toggle Bit I Toggle Bit I on DQ6 indicates whether an Embedded Program or Erase algorithm is in progress or complete, or whether the device has entered the Erase Suspend mode. Toggle Bit I may be read at any address, and is valid after the rising edge of the final WE# pulse in the command sequence (prior to the program or erase operation), and during the sector erase time-out. During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause DQ6 to toggle. The system may use either OE# or CE# to control the read cycles. When the operation is complete, DQ6 stops toggling. After an erase command sequence is written, if all sectors selected for erasing are protected, DQ6 toggles for approximately 100 µs, then returns to reading array data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected. The system can use DQ6 and DQ2 together to determine whether a sector is actively erasing or is erasesuspended. When the device is actively erasing (that is, the Embedded Erase algorithm is in progress), DQ6 toggles. When the device enters the Erase Suspend mode, DQ6 stops toggling. However, the system must also use DQ2 to determine which sectors are erasing or erase-suspended. Alternatively, the system can use DQ7 (see the subsection on “DQ7: Data# Polling”). If a program address falls within a protected sector, DQ6 toggles for approximately 2 µs after the program command sequence is written, then returns to reading array data. DQ6 also toggles during the erase-suspend-program mode, and stops toggling once the Embedded Program algorithm is complete. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Table 6 shows the outputs for Toggle Bit I on DQ6. Figure 5 shows the toggle bit algorithm. Figure 16 in the “AC Characteristics” section shows the toggle bit timing diagrams. Figure 17 shows the differences between DQ2 and DQ6 in graphical form. See also the subsection on “DQ2: Toggle Bit II”. DQ2: Toggle Bit II The “Toggle Bit II” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erase-suspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence. DQ2 toggles when the system reads at addresses within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and mode information. Refer to Table 6 to compare outputs for DQ2 and DQ6. Figure 5 shows the toggle bit algorithm in flowchart form, and the section “DQ2: Toggle Bit II” explains the algorithm. See also the “DQ6: Toggle Bit I” subsection. Figure 16 shows the toggle bit timing diagram. Figure 17 shows the differences between DQ2 and DQ6 in graphical form. Reading Toggle Bits DQ6/DQ2 Refer to Figure 5 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling. Typically, the system would note and store the value of the toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erase operation. The system can read array data on DQ7–DQ0 on the following read cycle. However, if after the initial two read cycles, the system determines that the toggle bit is still toggling, the system also should note whether the value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully completed the program or erase operation. If it is still toggling, the device did not complete the operation successfully, and the system must write the reset command to return to reading array data. Am29F400B 17 The remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5 has not gone high. The system may continue to monitor the toggle bit and DQ5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to perform other system tasks. In this case, the system must start at the beginning of the algorithm when it returns to determine the status of the operation (top of Figure 5). START Read DQ7–DQ0 Read DQ7–DQ0 (Note 1) Toggle Bit = Toggle? No DQ5: Exceeded Timing Limits DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit. Under these conditions DQ5 produces a “1.” This is a failure condition that indicates the program or erase cycle was not successfully completed. Yes The DQ5 failure condition may appear if the system tries to program a “1” to a location that is previously programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under this condition, the device halts the operation, and when the operation has exceeded the timing limits, DQ5 produces a “1.” No DQ5 = 1? Yes Under both these conditions, the system must issue the reset command to return the device to reading array data. Read DQ7–DQ0 Twice (Notes 1, 2) DQ3: Sector Erase Timer After writing a sector erase command sequence, the system may read DQ3 to determine whether or not an erase operation has begun. (The sector erase timer does not apply to the chip erase command.) If additional sectors are selected for erasure, the entire timeout also applies after each additional sector erase command. When the time-out is complete, DQ3 switches from “0” to “1.” If the time between additional sector erase commands from the system can be assumed to be less than 50 µs, the system need not monitor DQ3. See also the “Sector Erase Command Sequence” section. After the sector erase command sequence is written, the system should read the status on DQ7 (Data# Polling) or DQ6 (Toggle Bit I) to ensure the device has accepted the command sequence, and then read DQ3. If DQ3 is “1”, the internally controlled erase cycle has begun; all further commands (other than Erase Suspend) are ignored until the erase operation is complete. If DQ3 is “0”, the device will accept additional sector erase commands. To ensure the command has been accepted, the system software should check the status 18 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Toggle Bit = Toggle? No Yes Program/Erase Operation Not Complete, Write Reset Command Program/Erase Operation Complete Notes: 1. Read toggle bit twice to determine whether or not it is toggling. See text. 2. Recheck toggle bit because it may stop toggling as DQ5 changes to “1”. See text. 21505E-8 Figure 5. Toggle Bit Algorithm of DQ3 prior to and following each subsequent sector erase command. If DQ3 is high on the second status check, the last command might not have been accepted. Table 6 shows the outputs for DQ3. Am29F400B Table 6. Operation Standard Mode Erase Suspend Mode Embedded Program Algorithm Write Operation Status DQ7 (Note 2) DQ6 DQ5 (Note 1) DQ3 DQ2 (Note 2) RY/BY# DQ7# Toggle 0 N/A No toggle 0 Embedded Erase Algorithm 0 Toggle 0 1 Toggle 0 Reading within Erase Suspended Sector 1 No toggle 0 N/A Toggle 1 Reading within Non-Erase Suspended Sector Data Data Data Data Data 1 Erase-Suspend-Program DQ7# Toggle 0 N/A N/A 0 Notes: 1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits. See “DQ5: Exceeded Timing Limits” for more information. 2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 19 ABSOLUTE MAXIMUM RATINGS OPERATING RANGES Storage Temperature Plastic Packages . . . . . . . . . . . . . . . –65°C to +150°C Commercial (C) Devices Ambient Temperature with Power Applied . . . . . . . . . . . . . –55°C to +125°C Industrial (I) Devices Voltage with Respect to Ground VCC (Note 1) . . . . . . . . . . . . . . . .–2.0 V to +7.0 V A9, OE#, and RESET# (Note 2). . . . . . . . . . . . –2.0 V to +12.5 V Ambient Temperature (TA) . . . . . . . . . . .0°C to +70°C Ambient Temperature (TA) . . . . . . . . .–40°C to +85°C Extended (E) Devices Ambient Temperature (TA) . . . . . . . .–55°C to +125°C VCC Supply Voltages All other pins (Note 1) . . . . . . . . . –0.5 V to +7.0 V VCC for ± 5% devices . . . . . . . . . . +4.75 V to +5.25 V Output Short Circuit Current (Note 3) . . . . . . 200 mA VCC for ± 10% devices . . . . . . . . . . . +4.5 V to +5.5 V Notes: 1. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, input or I/O pins may overshoot VSS to –2.0 V for periods of up to 20 ns. See Figure 6. Maximum DC voltage on input or I/O pins is VCC +0.5 V. During voltage transitions, input or I/O pins may overshoot to V CC +2.0 V for periods up to 20 ns. See Figure 7. Note:Operating ranges define those limits between which the functionality of the device is guaranteed. 2. Minimum DC input voltage on pins A9, OE#, and RESET# is –0.5 V. During voltage transitions, A9, OE#, and RESET# may overshoot VSS to –2.0 V for periods of up to 20 ns. See Figure 6. Maximum DC input voltage on pin A9 is +12.5 V which may overshoot to +13.5 V for periods up to 20 ns. 3. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than one second. Note:Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational sections of this data sheet is not implied. Exposure of the device to absolute maximum rating conditions for extended periods may affect device reliability. 20 ns 20 ns 20 ns VCC +2.0 V VCC +0.5 V +0.8 V –0.5 V 2.0 V –2.0 V 20 ns 20 ns 20 ns 21505E-9 Figure 6. 20 Figure 7. Maximum Negative Overshoot Waveform Powered by ICminer.com Electronic-Library Service CopyRight 2003 21505E-10 Am29F400B Maximum Positive Overshoot Waveform DC CHARACTERISTICS TTL/NMOS Compatible Parameter Description Test Conditions ILI Input Load Current VIN = VSS to VCC, VCC = VCC max ILIT A9, OE#, RESET# Input Load Current VCC = VCC max; A9, OE#, RESET# = 12.5 V ILO Output Leakage Current VOUT = VSS to VCC, VCC = VCC max ICC1 VCC Active Read Current (Notes 1, 2) Min Typ Max Unit ±1.0 µA 50 µA ±1.0 µA CE# = VIL, OE# = VIH, f = 5 MHz, Byte Mode 19 40 mA CE# = VIL, OE# = VIH, f = 5 MHz, Word Mode 19 50 mA ICC2 VCC Active Write Current (Notes 2, 3, 4) CE# = VIL, OE# = VIH 36 60 mA ICC3 VCC Standby Current (Note 2) CE#, RESET#, and OE# = VIH 0.4 1 mA VIL Input Low Voltage –0.5 0.8 V VIH Input High Voltage 2.0 VCC +0.5 V VID Voltage for Autoselect and Temporary Sector Unprotect VCC = 5.0 V 11.5 12.5 V VOL Output Low Voltage IOL = 5.8 mA, VCC = VCC min 0.45 V VOH Output High Voltage IOH = –2.5 mA, VCC = VCC min VLKO Low VCC Lock-Out Voltage 2.4 3.2 V 4.2 V Notes: 1. The ICC current listed is typically less than 2 mA/MHz, with OE# at VIH.. 2. Maximum ICC specifications are tested with VCC = VCCmax. 3. ICC active while Embedded Erase or Embedded Program is in progress. 4. Not 100% tested. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 21 DC CHARACTERISTICS CMOS Compatible Parameter Description Test Conditions ILI Input Load Current VIN = VSS to VCC, VCC = VCC max ILIT A9, OE#, RESET# Input Load Current VCC = VCC max; A9, OE#, RESET# = 12.5 V ILO Output Leakage Current VOUT = VSS to VCC, VCC = VCC max ICC1 VCC Active Read Current (Notes 1, 2) CE# = VIL, OE# = VIH, f = 5 MHz, Byte Mode Typ 20 Max Unit ±1.0 µA 50 µA ±1.0 µA 40 mA CE# = VIL, OE# = VIH, f = 5 MHz, Word Mode 28 50 ICC2 VCC Active Write Current (Notes 2, 3, 4) CE# = VIL, OE# = VIH 30 50 mA ICC3 VCC Standby Current (Notes 2, 5 OE# = VIH, CE# and RESET# = VCC±0.5 V 0.3 5 µA VIL Input Low Voltage –0.5 0.8 V VIH Input High Voltage 0.7 x VCC VCC+ 0.3 V VID Voltage for Autoselect and Temporary Sector Unprotect VCC = 5.0 V 11.5 12.5 V VOL Output Low Voltage IOL = 5.8 mA, VCC = VCC min 0.45 V VOH1 IOH = –2.5 mA, VCC = VCC min 0.85 VCC IOH = –100 µA, VCC = VCC min VCC– 0.4 Output High Voltage VOH2 VLKO Low VCC Lock-Out Voltage 3.2 Notes: 1. The ICC current listed is typically less than 2 mA/MHz, with OE# at VIH. 2. Maximum ICC specifications are tested with VCC = VCCmax. 3. ICC active while Embedded Erase or Embedded Program is in progress. 4. Not 100% tested. 5. ICC3 = 20 µA max at extended temperature (>+85° C). 22 Min Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B V 4.2 V TEST CONDITIONS Table 7. Test Specifications 5.0 V 2.7 kΩ Device Under Test Output Load 6.2 kΩ CL -45, -50, -55 Test Condition Unit 1 TTL gate Output Load Capacitance, CL (including jig capacitance) 30 100 pF Input Rise and Fall Times 5 20 ns 0.0–3.0 0.45–2.4 V Input timing measurement reference levels 1.5 0.8, 2.0 V Output timing measurement reference levels 1.5 0.8, 2.0 V Input Pulse Levels Note: Diodes are IN3064 or equivalent. All others 21505E-11 Figure 8. Test Setup KEY TO SWITCHING WAVEFORMS WAVEFORM INPUTS OUTPUTS Steady Changing from H to L Changing from L to H Don’t Care, Any Change Permitted Changing, State Unknown Does Not Apply Center Line is High Impedance State (High Z) KS000010-PAL Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 23 AC CHARACTERISTICS Read Operations Parameter Speed Options JEDEC Std Description tAVAV tRC Read Cycle Time (Note 1) tAVQV tACC Address to Output Delay tELQV tCE Chip Enable to Output Delay tGLQV tOE tEHQZ tGHQZ tAXQX Test Setup -45 -50 -55 -70 -90 -120 -150 Unit Min 45 50 55 70 90 120 150 ns CE# = VIL OE# = VIL Max 45 50 55 70 90 120 150 ns OE# = VIL Max 45 50 55 70 90 120 150 ns Output Enable to Output Delay Max 30 30 30 30 35 50 55 ns tDF Chip Enable to Output High Z (Note 1) Max 15 15 15 20 20 30 35 ns tDF Output Enable to Output High Z (Note 1) Max 15 15 15 20 20 30 35 ns tOEH Output Enable Hold Time (Note 1) Toggle and Data# Polling Min 10 ns tOH Output Hold Time From Addresses, CE# or OE#, Whichever Occurs First (Note 1) Min 0 ns Read Min 0 ns Notes: 1. Not 100% tested. 2. See Figure 8 and Table 7 for test specifications. tRC Addresses Stable Addresses tACC CE# tDF tOE OE# tOEH WE# tCE tOH HIGH Z HIGH Z Output Valid Outputs RESET# RY/BY# 0V 21505E-12 Figure 9. 24 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Read Operations Timings Am29F400B AC CHARACTERISTICS Hardware Reset (RESET#) Parameter JEDEC Std Description Test Setup All Speed Options Unit tREADY RESET# Pin Low (During Embedded Algorithms) to Read or Write (See Note) Max 20 µs tREADY RESET# Pin Low (NOT During Embedded Algorithms) to Read or Write (See Note) Max 500 ns tRP RESET# Pulse Width Min 500 ns tRH RESET# High Time Before Read (See Note) Min 50 ns tRB RY/BY# Recovery Time Min 0 ns Note: Not 100% tested. RY/BY# CE#, OE# tRH RESET# tRP tReady Reset Timings NOT during Embedded Algorithms Reset Timings during Embedded Algorithms tReady RY/BY# tRB CE#, OE# RESET# tRP 21505E-13 Figure 10. Powered by ICminer.com Electronic-Library Service CopyRight 2003 RESET# Timings Am29F400B 25 AC CHARACTERISTICS Word/Byte Configuration (BYTE#) Parameter JEDEC Std Speed Options Description -45 tELFL/tELFH CE# to BYTE# Switching Low or High -50 -55 -70 Max -90 -120 -150 5 Unit ns tFLQZ BYTE# Switching Low to Output HIGH Z Max 15 15 15 20 20 30 35 ns tFHQV BYTE# Switching High to Output Active Min 45 50 55 70 90 120 150 ns CE# OE# BYTE# BYTE# Switching from word to byte mode tELFL Data Output (DQ0–DQ14) DQ0–DQ14 Address Input DQ15 Output DQ15/A-1 Data Output (DQ0–DQ7) tFLQZ tELFH BYTE# BYTE# Switching from byte to word mode Data Output (DQ0–DQ7) DQ0–DQ14 Address Input DQ15/A-1 Data Output (DQ0–DQ14) DQ15 Output tFHQV 21505E-14 Figure 11. BYTE# Timings for Read Operations CE# The falling edge of the last WE# signal WE# BYTE# tSET (tAS) tHOLD (tAH) Note: Refer to the Erase/Program Operations table for tAS and tAH specifications. 21505E-15 Figure 12. 26 Powered by ICminer.com Electronic-Library Service CopyRight 2003 BYTE# Timings for Write Operations Am29F400B AC CHARACTERISTICS Erase/Program Operations Parameter Speed Options JEDEC Std Description -45 -50 -55 -70 -90 -120 -150 Unit tAVAV tWC Write Cycle Time (Note 1) Min 45 50 55 70 90 120 150 ns tAVWL tAS Address Setup Time Min tWLAX tAH Address Hold Time Min 45 45 45 45 45 50 50 ns tDVWH tDS Data Setup Time Min 25 25 25 30 45 50 50 ns tWHDX tDH Data Hold Time Min 0 ns tOES Output Enable Setup Time Min 0 ns Read Recovery Time Before Write (OE# High to WE# Low) Min 0 ns 0 ns tGHWL tGHWL tELWL tCS CE# Setup Time Min 0 ns tWHEH tCH CE# Hold Time Min 0 ns tWLWH tWP Write Pulse Width Min tWHWL tWPH Write Pulse Width High Min 20 Typ 7 tWHWH1 Programming Operation (Note 2) Byte tWHWH1 Word Typ 12 tWHWH2 tWHWH2 Sector Erase Operation (Note 2) Typ 1 sec 30 30 30 35 45 50 50 ns ns µs tVCS VCC Setup Time (Note 1) Min 50 µs tRB Recovery Time from RY/BY# Min 0 ns Program/Erase Valid to RY/BY# Delay Min tBUSY 30 30 30 30 35 50 55 ns Notes: 1. Not 100% tested. 2. See the “Erase and Programming Performance” section for more information. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 27 AC CHARACTERISTICS Program Command Sequence (last two cycles) tAS tWC Addresses 555h Read Status Data (last two cycles) PA PA PA tAH CE# tCH OE# tWHWH1 tWP WE# tWPH tCS tDS tDH A0h Data PD Status tBUSY DOUT tRB RY/BY# tVCS VCC Notes: 1. PA = program address, PD = program data, DOUT is the true data at the program address. 2. Illustration shows device in word mode. 21505E-16 Figure 13. 28 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Program Operation Timings Am29F400B AC CHARACTERISTICS Erase Command Sequence (last two cycles) tAS tWC 2AAh Addresses Read Status Data VA SA VA 555h for chip erase tAH CE# tCH OE# tWP WE# tWPH tCS tWHWH2 tDS tDH Data 55h In Progress 30h Complete 10 for Chip Erase tBUSY tRB RY/BY# tVCS VCC Notes: 1. SA = sector address (for Sector Erase), VA = Valid Address for reading status data (see “Write Operation Status”). 2. Illustration shows device in word mode. 21505E-17 Figure 14. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Chip/Sector Erase Operation Timings Am29F400B 29 AC CHARACTERISTICS tRC Addresses VA VA VA tACC tCE CE# tCH tOE OE# tOEH tDF WE# tOH High Z DQ7 Complement Complement DQ0–DQ6 Status Data Status Data Valid Data True High Z Valid Data True tBUSY RY/BY# Note: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data read cycle. 21505E-18 Figure 15. Data# Polling Timings (During Embedded Algorithms) tRC Addresses VA VA VA VA tACC tCE CE# tCH tOE OE# tOEH tDF WE# tOH High Z DQ6/DQ2 tBUSY Valid Status Valid Status (first read) (second read) Valid Status Valid Data (stops toggling) RY/BY# Note: VA = Valid address; not required for DQ6. Illustration shows first two status cycle after command sequence, last status read cycle, and array data read cycle. 21505E-19 Figure 16. 30 Toggle Bit Timings (During Embedded Algorithms) Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B AC CHARACTERISTICS Enter Embedded Erasing Erase Suspend Erase Resume Erase Suspend Program Erase Suspend Read Erase WE# Enter Erase Suspend Program Erase Complete Erase Erase Suspend Read DQ6 DQ2 Note: The system may use either CE# or OE# to toggle DQ2 and DQ6. DQ2 toggles only when read at an address within an erase-suspended sector. 21505E-20 Figure 17. DQ2 vs. DQ6 Temporary Sector Unprotect Parameter JEDEC Std Description tVIDR VID Rise and Fall Time (See Note) tRSP RESET# Setup Time for Temporary Sector Unprotect All Speed Options Unit Min 500 ns Min 4 µs Note: Not 100% tested. 12 V RESET# 0 or 5 V 0 or 5 V tVIDR tVIDR Program or Erase Command Sequence CE# WE# tRSP RY/BY# 21505E-21 Figure 18. Temporary Sector Unprotect Timing Diagram Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 31 AC CHARACTERISTICS Alternate CE# Controlled Erase/Program Operations Parameter Speed Options JEDEC Std Description -45 -50 -55 -70 -90 -120 -150 Unit tAVAV tWC Write Cycle Time (Note 1) Min 45 50 55 70 90 120 150 ns tAVEL tAS Address Setup Time Min tELAX tAH Address Hold Time Min 45 45 45 45 45 50 50 ns tDVEH tDS Data Setup Time Min 25 25 25 30 45 50 50 ns tEHDX tDH Data Hold Time Min 0 ns tOES Output Enable Setup Time Min 0 ns tGHEL tGHEL Read Recovery Time Before Write (OE# High to WE# Low) Min 0 ns tWLEL tWS WE# Setup Time Min 0 ns tEHWH tWH WE# Hold Time Min 0 ns tELEH tCP CE# Pulse Width Min tEHEL tCPH CE# Pulse Width High Min 20 Typ 7 tWHWH1 Programming Operation (Note 2) Byte tWHWH1 Word Typ 12 tWHWH2 tWHWH2 Sector Erase Operation (Note 2) Typ 1 0 30 30 2. See the “Erase and Programming Performance” section for more information. 32 35 45 50 50 ns ns µs Notes: 1. Not 100% tested. Powered by ICminer.com Electronic-Library Service CopyRight 2003 30 ns Am29F400B sec AC CHARACTERISTICS 555 for program 2AA for erase PA for program SA for sector erase 555 for chip erase Data# Polling Addresses PA tWC tAS tAH tWH WE# tGHEL OE# tCP CE# tWS tWHWH1 or 2 tCPH tBUSY tDS tDH DQ7# Data tRH A0 for program 55 for erase DOUT PD for program 30 for sector erase 10 for chip erase RESET# RY/BY# Notes: 1. PA = Program Address, PD = Program Data, SA = Sector Address, DQ7# = Complement of Data Input, DOUT = Array Data. 2. Figure indicates the last two bus cycles of the command sequence, with the device in word mode. 21505E-22 Figure 19. Alternate CE# Controlled Write Operation Timings Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 33 ERASE AND PROGRAMMING PERFORMANCE Parameter Typ (Note 1) Max (Note 2) Unit Sector Erase Time 1.0 8 s Chip Erase Time 11 Byte Programming Time 7 300 µs Word Programming Time 12 500 µs Chip Programming Time Byte Mode 3.6 10.8 s (Note 3) Word Mode 3.1 9.3 s s Comments Excludes 00h programming prior to erasure Excludes system level overhead (Note 5) Notes: 1. Typical program and erase times assume the following conditions: 25°C, 5.0 V VCC, 1,000,000 cycles. Additionally, programming typicals assume checkerboard pattern. 2. Under worst case conditions of 90°C, VCC = 4.5 V, 1,000,000 cycles. 3. The typical chip programming time is considerably less than the maximum chip programming time listed, since most bytes program faster than the maximum program times listed. 4. In the pre-programming step of the Embedded Erase algorithm, all bytes are programmed to 00h before erasure. 5. System-level overhead is the time required to execute the four-bus-cycle sequence for the program command. See Table 5 for further information on command definitions. 6. The device has a guaranteed minimum erase and program cycle endurance of 1,000,000 cycles. LATCHUP CHARACTERISTICS Description Min Max Input voltage with respect to VSS on all pins except I/O pins (including A9, OE#, and RESET#) –1.0 V 12.5 V Input voltage with respect to VSS on all I/O pins –1.0 V VCC + 1.0 V –100 mA +100 mA VCC Current Includes all pins except VCC. Test conditions: VCC = 5.0 V, one pin at a time. TSOP AND SO PIN CAPACITANCE Parameter Symbol Parameter Description Test Setup Typ Max Unit CIN Input Capacitance VIN = 0 6 7.5 pF COUT Output Capacitance VOUT = 0 8.5 12 pF CIN2 Control Pin Capacitance VIN = 0 7.5 9 pF Notes: 1. Sampled, not 100% tested. 2. Test conditions TA = 25°C, f = 1.0 MHz. DATA RETENTION Parameter Test Conditions Min Unit 150°C 10 Years 125°C 20 Years Minimum Pattern Data Retention Time 34 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B PHYSICAL DIMENSIONS TS 048 48-Pin Standard Thin Small Outline Package (measured in millimeters) Dwg rev AA; 10/99 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 35 PHYSICAL DIMENSIONS TSR048 48-Pin Reverse Thin Small Outline Package (measured in millimeters) Dwg rev AA; 10/99 36 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B PHYSICAL DIMENSIONS SO 044 44-Pin Small Outline Package (measured in millimeters) Dwg rev AC; 10/99 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 37 REVISION SUMMARY Revision C (January 1998) Erase and Programming Performance Global Changed minimum 100K program and erase cycles guaranteed to 1,000,000. Formatted for consistency with other 5.0 volt-only data sheets. Revision C+3 (June 1998) AC Characteristics Distinctive Characteristics Changed tDF and TFLQZ to 15 ns for -55 speed option. High Performance: Changed “Access times as fast as 55 ns” to “Access times as fast as 45 ns”. Revision C+1 (February 1998) General Description Table 2, Top Boot Block Sector Address Table Third paragraph: Added 45 ns to access times. Corrected the sector size for SA10 to 16 Kbytes/ 8 Kwords. Product Selector Guide DC Characteristics—TTL/NMOS Compatible Added the -45 speed option for VCC = 5.0 V ± 5% and the -55 speed option for VCC = 5.0 V ± 10%. Deleted Note 4. Ordering Information Revision C+2 (April 1998) Distinctive Characteristics Changed minimum 100K write/erase cycles guaranteed to 1,000,000. Product Selector Guide, Ordering Information Added 55 ns ±10% speed option. Added “Special Designation” to “Optional Processing” heading; added “0” for 55 ns 10% VCC, deleted burn-in. Burn-in is available by contacting an AMD representative. Added -55 ± 10% and -45 speed options to the list of valid combinations. Added extended temperature ratings to -55 ±5% valid combinations. Table 1, Device Bus Operations AC Characteristics Word/Byte Configuration: Changed tFHQV specification for 55 ns device. Erase/Program Operations: Changed t WHWH1 word mode specification to 12 µs. Corrected the notes reference for tWHWH1 and tWHWH2. These parameters are 100% tested. Corrected the note reference for tVCS. This parameter is not 100% tested. Changed tDS and tCP specifications for 55 ns device. Alternate CE# Controlled Erase/Program Operations: Changed tWHWH1 word mode specification to 12 µs. Corrected the notes reference for tWHWH1 and tWHWH2. These parameters are 100% tested. Changed tDS and tCP specifications for 55 ns device. Changed the BYTE#=VIL input for DQ8–DQ15 during temporary sector unprotect to “don’t care” (X). Figure 6. Maximum Negative Undershoot Waveform Corrected figure title. Table 7, Test Specifications Test load capacitance: Removed 55 ns speed option from and added -45 speed option to the 30 pF. DC Characteristics Removed VCC = VCC max test condition for ICC1 – ICC3. VCC max is only valid for max specs. AC Characteristics Added the -45 speed option. Temporary Sector Unprotect Table Added note reference for tVIDR. This parameter is not 100% tested. 38 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B REVISION SUMMARY (continued) Revision C+4 (August 1998) Revision D+1 (July 2, 1999) Ordering Information Global Added extended temperature combinations to the -55, ±10% speed option. Added references to availability of device in Known Good Die (KGD) form. Deleted the -60 speed option. Revision E (November 15, 1999) Revision D (January 1999) AC Characteristics—Figure 13. Program Operations Timing and Figure 14. Chip/Sector Erase Operations Distinctive Characteristics Added: Deleted tGHWL and changed OE# waveform to start at high. ■ 20-year data retention at 125°C — Reliable operation for the life of the system Physical Dimensions DC Characteristics—TTL/NMOS Compatible Replaced figures with more detailed illustrations. ICC1, ICC2, ICC3: Added Note 2 “Maximum ICC specifications are tested with VCC = VCCmax”. DC Characteristics—CMOS Compatible ICC1, ICC2, ICC3: Added Note 2 “Maximum ICC specifications are tested with VCC = VCCmax”. Erase and Programming Performance Deleted “(4.75 V for -45 and -55xx0)” from Note 2. Trademarks Copyright © 2000 Advanced Micro Devices, Inc. All rights reserved. AMD, the AMD logo, and combinations thereof are registered trademarks of Advanced Micro Devices, Inc. ExpressFlash is a trademark of Advanced Micro Devices, Inc. Product names used in this publication are for identification purposes only and may be trademarks of their respective companies. Powered by ICminer.com Electronic-Library Service CopyRight 2003 Am29F400B 39