AMD AM29LV081

PRELIMINARY
Am29LV081
8 Megabit (1 M x 8-Bit)
CMOS 3.0 Volt-only Uniform Sector Flash Memory
DISTINCTIVE CHARACTERISTICS
■ Optimized architecture for Miniature Card and
mass storage applications
■ Single power supply operation
— Full voltage range: 2.7 to 3.6 volt read and write
operations for battery-powered applications
— Regulated voltage range: 3.0 to 3.6 volt read and
write operations and for compatibility with high
performance 3.3 volt microprocessors
■ High performance
■ Embedded Algorithms
— Embedded Erase algorithm automatically
preprograms and erases the entire chip or any
combination of designated sectors
— Embedded Program algorithm automatically
writes and verifies data at specified addresses
■ Typical 1,000,000 write cycles per sector
(100,000 cycles minimum guaranteed)
■ Package option
— Full voltage range: access times as fast as 100
ns
— Regulated voltage range: access times as fast
as 90 ns
■ Ultra low power consumption (typical values at
5 MHz)
— 200 nA Automatic Sleep mode current
— 200 nA standby mode current
— 10 mA read current
— 20 mA program/erase current
■ Flexible sector architecture
— Sixteen 64 Kbyte sectors
— Supports full chip erase
— Sector Protection features:
A hardware method of locking a sector (using
programming equipment) to prevent any
program or erase operations within that sector
Temporary Sector Unprotect feature allows code
changes in previously locked sectors
— 40-pin TSOP
■ Compatibility with JEDEC standards
— Pinout and software compatible with singlepower supply Flash
— Superior inadvertent write protection
■ Data# Polling and toggle bits
— Provides a software method of detecting
program or erase operation completion
■ Ready/Busy# pin (RY/BY#)
— Provides a hardware method of detecting
program or erase cycle completion
■ Erase Suspend/Erase Resume
— Suspends an erase operation to read data from,
or program data to, a sector that is not being
erased, then resumes the erase operation
■ Hardware reset pin (RESET#)
— Hardware method to reset the device to reading
array data
Publication# 20977 Rev: C Amendment/+1
Issue Date: March 1998
Refer to AMD’s Website (www.amd.com) for the latest information.
P R E L I M I N A R Y
GENERAL DESCRIPTION
The Am29LV081 is an 8 Mbit, 3.0 volt-only Flash
memory organized as 1,048,576 bytes. The device is
offered in a 40-pin TSOP package. The byte-wide (x8)
data appears on DQ7–DQ0. This device requires only
a single, 3.0 volt VCC supply to perform read, program,
and erase operations. A standard EPROM programmer can also be used to program and erase the
device.
The standard device offers access times of 90, 100,
120, and 150 ns, allowing high speed microprocessors
to operate without wait states. To eliminate bus contention the device has separate chip enable (CE#), write
enable (WE#) and output enable (OE#) controls.
The device requires only a single 3.0 volt power supply for both read and write functions. Internally generated and regulated voltages are provided for the
program and erase operations.
The device is entirely command set compatible with the
JEDEC single-power-supply Flash standard. Commands are written to the command register using standard microprocessor write timings. Register contents
serve as input to an internal state-machine that controls the erase and programming circuitry. Write cycles
also internally latch addresses and data needed for the
programming and erase operations. Reading data out
of the device is similar to reading from other Flash or
EPROM devices.
Device programming occurs by executing the program
command sequence. This initiates the Embedded
Program algorithm—an internal algorithm that automatically times the program pulse widths and verifies
proper cell margin.
Device erasure occurs by executing the erase command
sequence. This initiates the Embedded Erase algorithm—an internal algorithm that automatically preprograms the array (if it is not already programmed) before
executing the erase operation. During erase, the device
automatically times the erase pulse widths and verifies
proper cell margin.
2
The host system can detect whether a program or
erase operation is complete by observing the RY/BY#
pin, or by reading the DQ7 (Data# Polling) and DQ6
(toggle) status bits. After a program or erase cycle has
been completed, the device is ready to read array data
or accept another command.
The sector erase architecture allows memory sectors
to be erased and reprogrammed without affecting the
data contents of other sectors. The device is fully
erased when shipped from the factory.
Hardware data protection measures include a low
VCC detector that automatically inhibits write operations during power transitions. The hardware sector
protection feature disables both program and erase
operations in any combination of the sectors of memory. This is achieved via programming equipment.
The Erase Suspend feature enables the user to put
erase on hold for any period of time to read data from,
or program data to, any sector that is not selected for
erasure. True background erase can thus be achieved.
The hardware RESET# pin terminates any operation
in progress and resets the internal state machine to
reading array data. The RESET# pin may be tied to the
system reset circuitry. A system reset would thus also
reset the device, enabling the system microprocessor
to read the boot-up firmware from the Flash memory.
The device offers two power-saving features. When addresses have been stable for a specified amount of
time, the device enters the automatic sleep mode.
The system can also place the device into the standby
mode. Power consumption is greatly reduced in both
these modes.
AMD’s Flash technology combines years of Flash
memory manufacturing experience to produce the
highest levels of quality, reliability and cost effectiveness. The device electrically erases all bits within
a sector simultaneously via Fowler-Nordheim tunneling. The data is programmed using hot electron
injection.
Am29LV081
P R E L I M I N A R Y
PRODUCT SELECTOR GUIDE
Family Part Number
Speed Options
Am29LV081
Regulated Voltage Range: VCC =3.0–3.6 V
-90R
Full Voltage Range: VCC = 2.7–3.6 V
-100
-120
-150
Max access time, ns (tACC)
90
100
120
150
Max CE# access time, ns (tCE)
90
100
120
150
Max OE# access time, ns (tOE)
40
40
50
55
Note: See “AC Characteristics” for full specifications.
BLOCK DIAGRAM
DQ0–DQ7
RY/BY#
VCC
Sector Switches
VSS
Erase Voltage
Generator
RESET#
WE#
Input/Output
Buffers
State
Control
Command
Register
PGM Voltage
Generator
Chip Enable
Output Enable
CE#
OE#
VCC Detector
Address Latch
STB
Timer
A0–A19
Data
STB
Y-Decoder
Y-Gating
X-Decoder
Cell Matrix
20977C-1
Am29LV081
3
P R E L I M I N A R Y
CONNECTION DIAGRAMS
A16
A15
A14
A13
A12
A11
A9
A8
WE#
RESET#
NC
RY/BY#
A18
A7
A6
A5
A4
A3
A2
A1
A17
VSS
NC
A19
A10
DQ7
DQ6
DQ5
DQ4
VCC
VCC
NC
DQ3
DQ2
DQ1
DQ0
CE#
VSS
CE#
A0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
Standard TSOP
Reverse TSOP
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
A17
VSS
NC
A19
A10
DQ7
DQ6
DQ5
DQ4
VCC
VCC
NC
DQ3
DQ2
DQ1
DQ0
OE#
VSS
CE#
A0
A16
A15
A14
A13
A12
A11
A9
A8
WE#
RESET#
NC
RY/BY#
A18
A7
A6
A5
A4
A3
A2
A1
20977C-2
4
Am29LV081
P R E L I M I N A R Y
PIN CONFIGURATION
A0–A19
LOGIC SYMBOL
= 20 addresses
20
DQ0–DQ7 = 8 data inputs/outputs
A0–A19
CE#
= Chip enable
OE#
= Output enable
WE#
= Write enable
CE#
RESET#
= Hardware reset pin, active low
OE#
RY/BY#
= Ready/Busy# output
WE#
VCC
= 3.0 volt-only single power supply
(see Product Selector Guide for speed
options and voltage supply tolerances)
RESET#
VSS
= Device ground
NC
= Pin not connected internally
8
DQ0–DQ7
RY/BY#
20977C-3
Am29LV081
5
P R E L I M I N A R Y
ORDERING INFORMATION
Standard Products
AMD standard products are available in several packages and operating ranges. The order number (Valid Combination) is formed by a combination of the elements below.
Am29LV081
-90R
E
C
OPTIONAL PROCESSING
Blank = Standard Processing
B = Burn-in
(Contact an AMD representative for more information)
TEMPERATURE RANGE
C = Commercial (0°C to +70°C)
I = Industrial (–40°C to +85°C)
E = Extended (–55°C to +125°C)
PACKAGE TYPE
E
= 40-Pin Thin Small Outline Package (TSOP)
Standard Pinout (TS 040)
F
= 40-Pin Thin Small Outline Package (TSOP)
Reverse Pinout (TSR040)
SPEED OPTION
See Product Selector Guide and Valid Combinations
DEVICE NUMBER/DESCRIPTION
Am29LV081
8 Megabit (1 M x 8-Bit) CMOS Flash Memory
3.0 Volt-only Read, Program, and Erase
Valid Combinations
Valid Combinations
Am29LV081-90R
VCC = 3.0–3.6 V
EC, EI, FC, FI
Valid Combinations list configurations planned to be supported in volume for this device. Consult the local AMD sales
office to confirm availability of specific valid combinations and
to check on newly released combinations.
Am29LV081-100
Am29LV081-120
EC, EI, EE,
FC, FI, FE
Am29LV081-150
6
Am29LV081
P R E L I M I N A R Y
DEVICE BUS OPERATIONS
This section describes the requirements and use of the
device bus operations, which are initiated through the
internal command register. The command register itself does not occupy any addressable memory location. The register is composed of latches that store the
commands, along with the address and data information needed to execute the command. The contents of
Table 1.
Operation
the register serve as inputs to the internal state machine. The state machine outputs dictate the function of
the device. Table 1 lists the device bus operations, the
inputs and control levels they require, and the resulting
output. The following subsections describe each of
these operations in further detail.
Am29LV081 Device Bus Operations
CE#
OE#
WE#
RESET#
Addresses (See Note)
DQ0–DQ7
Read
L
L
H
H
AIN
DOUT
Write
L
H
L
H
AIN
DIN
VCC ±
0.3 V
X
X
VCC ±
0.3 V
X
High-Z
Output Disable
L
H
H
H
X
High-Z
Reset
X
X
X
L
X
High-Z
Temporary Sector Unprotect
X
X
X
VID
X
X
Standby
Legend:
L = Logic Low = VIL, H = Logic High = VIH, VID = 12.0 ± 0.5 V, X = Don’t Care, AIN = Address In, DIN = Data In, DOUT = Data Out
Note: Addresses are A19–A0.
Requirements for Reading Array Data
To read array data from the outputs, the system must
drive the CE# and OE# pins to VIL. CE# is the power
control and selects the device. OE# is the output control and gates array data to the output pins. WE# should
remain at VIH.
The internal state machine is set for reading array
data upon device power-up, or after a hardware reset.
This ensures that no spurious alteration of the memory content occurs during the power transition. No
command is necessary in this mode to obtain array
data. Standard microprocessor read cycles that assert valid addresses on the device address inputs produce valid data on the device data outputs. The device
remains enabled for read access until the command
register contents are altered.
See “Reading Array Data” for more information. Refer
to the AC Read Operations table for timing specifications and to Figure 12 for the timing diagram. ICC1 in
the DC Characteristics table represents the active current specification for reading array data.
Writing Commands/Command Sequences
To write a command or command sequence (which includes programming data to the device and erasing
sectors of memory), the system must drive WE# and
CE# to VIL, and OE# to VIH.
An erase operation can erase one sector, multiple sectors, or the entire device. Table 2 indicates the address
space that each sector occupies. A “sector address”
consists of the address bits required to uniquely select
a sector. See the “Command Definitions” section for
details on erasing a sector or the entire chip, or suspending/resuming the erase operation.
After the system writes the autoselect command sequence, the device enters the autoselect mode. The
system can then read autoselect codes from the internal register (which is separate from the memory array)
on DQ7–DQ0. Standard read cycle timings apply in this
mode. Refer to the “Autoselect Mode” and “Autoselect
Command Sequence” sections for more information.
ICC2 in the DC Characteristics table represents the active current specification for the write mode. The “AC
Characteristics” section contains timing specification
tables and timing diagrams for write operations.
Program and Erase Operation Status
During an erase or program operation, the system may
check the status of the operation by reading the status
bits on DQ7–DQ0. Standard read cycle timings and ICC
read specifications apply. Refer to “Write Operation
Status” for more information, and to “AC Characteristics” for timing diagrams.
Standby Mode
When the system is not reading or writing to the device,
it can place the device in the standby mode. In this
mode, current consumption is greatly reduced, and the
Am29LV081
7
P R E L I M I N A R Y
outputs are placed in the high impedance state, independent of the OE# input.
The device enters the CMOS standby mode when the
CE# and RESET# pins are both held at VCC ± 0.3 V.
(Note that this is a more restricted voltage range than
VIH.) If CE# and RESET# are held at VIH, but not within
VCC ± 0.3 V, the device will be in the standby mode, but
the standby current will be greater. The device requires
standard access time (tCE) for read access when the
device is in either of these standby modes, before it is
ready to read data.
If the device is deselected during erasure or programming, the device draws active current until the
operation is completed.
In the DC Characteristics table, ICC3 and ICC4 represents the standby current specifications.
Automatic Sleep Mode
The automatic sleep mode minimizes Flash device
energy consumption. The device automatically enables
this mode when addresses remain stable for tACC + 30
ns. The automatic sleep mode is independent of the
CE#, WE#, and OE# control signals. Standard address
access timings provide new data when addresses are
changed. While in sleep mode, output data is latched
and always available to the system. ICC5 in the DC
Characteristics table represents the automatic sleep
mode current specification.
RESET#: Hardware Reset Pin
The RESET# pin provides a hardware method of resetting the device to reading array data. When the system
drives the RESET# pin to VIL for at least a period of tRP,
the device immediately terminates any operation in
8
progress, tristates all data output pins, and ignores all
read/write attempts for the duration of the RESET#
pulse. The device also resets the internal state machine to reading array data. The operation that was interrupted should be reinitiated once the device is ready
to accept another command sequence, to ensure data
integrity.
Current is reduced for the duration of the RESET#
pulse. When RESET# is held at VSS±0.3 V, the device
draws CMOS standby current (ICC4). If RESET# is held
at VIL but not within VSS±0.3 V, the standby current will
be greater.
The RESET# pin may be tied to the system reset circuitry. A system reset would thus also reset the Flash
memory, enabling the system to read the boot-up firmware from the Flash memory.
If RESET# is asserted during a program or erase operation, the RY/BY# pin remains a “0” (busy) until the
internal reset operation is complete, which requires a
time of tREADY (during Embedded Algorithms). The
system can thus monitor RY/BY# to deter mine
whether the reset operation is complete. If RESET# is
asserted when a program or erase operation is not executing (RY/BY# pin is “1”), the reset operation is
completed within a time of tREADY (not during Embedded Algorithms). The system can read data tRH after
the RESET# pin returns to VIH.
Refer to the AC Characteristics tables for RESET# parameters and to Figure 13 for the timing diagram.
Output Disable Mode
When the OE# input is at VIH, output from the device is
disabled. The output pins are placed in the high impedance state.
Am29LV081
P R E L I M I N A R Y
Table 2.
Am29LV081 Sector Address Table
A19
A18
A17
A16
A15
A14
A13
Sector Size
Address Range
SA0
0
0
0
0
X
X
X
64 Kbytes
00000h-0FFFFh
SA1
0
0
0
1
X
X
X
64 Kbytes
10000h-1FFFFh
SA2
0
0
1
0
X
X
X
64 Kbytes
20000h-2FFFFh
SA3
0
0
1
1
X
X
X
64 Kbytes
30000h-3FFFFh
SA4
0
1
0
0
X
X
X
64 Kbytes
40000h-4FFFFh
SA5
0
1
0
1
X
X
X
64 Kbytes
50000h-5FFFFh
SA6
0
1
1
0
X
X
X
64 Kbytes
60000h-6FFFFh
SA7
0
1
1
1
X
X
X
64 Kbytes
70000h-7FFFFh
SA8
1
0
0
0
X
X
X
64 Kbytes
80000h-8FFFFh
SA9
1
0
0
1
X
X
X
64 Kbytes
90000h-9FFFFh
SA10
1
0
1
0
X
X
X
64 Kbytes
A0000h-AFFFFh
SA11
1
0
1
1
X
X
X
64 Kbytes
B0000h-BFFFFh
SA12
1
1
0
0
X
X
X
64 Kbytes
C0000h-CFFFFh
SA13
1
1
0
1
X
X
X
64 Kbytes
D0000h-DFFFFh
SA14
1
1
1
0
X
X
X
64 Kbytes
E0000h-EFFFFh
SA15
1
1
1
1
X
X
X
64 Kbytes
F0000h-FFFFFh
Autoselect Mode
The autoselect mode provides manufacturer and device identification, and sector protection verification,
through identifier codes output on DQ7–DQ0. This
mode is primarily intended for programming equipment
to automatically match a device to be programmed with
its corresponding programming algorithm. However,
the autoselect codes can also be accessed in-system
through the command register.
tor address must appear on the appropriate highest
order address bits (see Table 2). Table 3 shows the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming
equipment may then read the corresponding identifier
code on DQ7–DQ0.
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in Table 4. This method
does not require VID. See “Command Definitions” for
details on using the autoselect mode.
When using programming equipment, the autoselect
mode requires VID (11.5 V to 12.5 V) on address pin A9.
Address pins A6, A1, and A0 must be as shown in Table
3. In addition, when verifying sector protection, the sec-
Table 3.
Am29LV081 Autoselect Codes (High Voltage Method)
CE#
OE#
WE#
A19
to
A13
Manufacturer ID: AMD
L
L
H
X
X
VID
X
L
X
L
L
01h
Device ID: Am29LV081
L
L
H
X
X
VID
X
L
X
L
H
38h
Description
A12
to
A10
A9
A8
to
A7
A6
A5
to
A2
A1
A0
DQ7
to
DQ0
01h
(protected)
Sector Protection Verification
L
L
H
SA
X
VID
X
L
X
H
L
00h
(unprotected)
L = Logic Low = VIL, H = Logic High = VIH, SA = Sector Address, X = Don’t care.
Am29LV081
9
P R E L I M I N A R Y
Sector Protection/Unprotection
Logical Inhibit
The hardware sector protection feature disables both
program and erase operations in any sector. The hardware sector unprotection feature re-enables both program and erase operations in previously protected
sectors.
Write cycles are inhibited by holding any one of OE#
= VIL, CE# = VIH or WE# = VIH. To initiate a write cycle, CE# and WE# must be a logical zero while OE#
is a logical one.
The device is shipped with all sectors unprotected.
AMD offers the option of programming and protecting
sectors at its factory prior to shipping the device
through AMD’s ExpressFlash™ Service. Contact an
AMD representative for details.
If WE# = CE# = V IL and OE# = V IH during power
up, the device does not accept commands on the
rising edge of WE#. The internal state machine is
a u t o m a ti c a l l y r e s e t to r e a d i n g a r ray d at a o n
power-up.
Power-Up Write Inhibit
It is possible to determine whether a sector is protected
or unprotected. See “Autoselect Mode” for details.
START
Sector protection/unprotection must be implemented
using programming equipment.The procedure requires
a high voltage (VID) on address pin A9 and OE#. Details on this method are provided in a supplement, publication number 21225. Contact an AMD representative
to request a copy.
RESET# = VID
(Note 1)
Perform Erase or
Program Operations
Temporary Sector Unprotect
This feature allows temporary unprotection of previously protected sectors to change data in-system. The
Sector Unprotect mode is activated by setting the RESET# pin to VID. During this mode, formerly protected
sectors can be programmed or erased by selecting the
sector addresses. Once VID is removed from the RESET# pin, all the previously protected sectors are
protected again. Figure 1 shows the algorithm, and
Figure 19 shows the timing diagrams, for this feature.
RESET# = VIH
Temporary Sector
Unprotect Completed
(Note 2)
20977C-4
Hardware Data Protection
The command sequence requirement of unlock cycles
for programming or erasing provides data protection
against inadvertent writes (refer to Table 4 for command definitions). In addition, the following hardware
data protection measures prevent accidental erasure
or programming, which might otherwise be caused by
spurious system level signals during VCC power-up and
power-down transitions, or from system noise.
Notes:
1. All protected sectors unprotected.
2. All previously protected sectors are protected once
again.
Figure 1.
Low VCC Write Inhibit
When VCC is less than VLKO, the device does not accept any write cycles. This protects data during VCC
power-up and power-down. The command register and
all internal program/erase circuits are disabled, and the
device resets. Subsequent writes are ignored until VCC
is greater than V LKO. The system must provide the
proper signals to the control pins to prevent unintentional writes when VCC is greater than VLKO.
Write Pulse “Glitch” Protection
Noise pulses of less than 5 ns (typical) on OE#, CE# or
WE# do not initiate a write cycle.
10
Am29LV081
Temporary Sector Unprotect Operation
P R E L I M I N A R Y
COMMAND DEFINITIONS
Writing specific address and data commands or sequences into the command register initiates device operations. Table 4 defines the valid register command
sequences. Writing incorrect address and data values or writing them in the improper sequence resets
the device to reading array data.
All addresses are latched on the falling edge of WE# or
CE#, whichever happens later. All data is latched on
the rising edge of WE# or CE#, whichever happens
first. Refer to the appropriate timing diagrams in the
“AC Characteristics” section.
The reset command may be written between the sequence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command must
be written to return to reading array data (also applies
to autoselect during Erase Suspend).
If DQ5 goes high during a program or erase operation,
writing the reset command returns the device to reading array data (also applies during Erase Suspend).
See the applicable “AC Characteristics” section for parameters, and to the Figure 13 for the timing waveforms.
Autoselect Command Sequence
Reading Array Data
The device is automatically set to reading array data
after device power-up. No commands are required to
retrieve data. The device is also ready to read array
data after completing an Embedded Program or Embedded Erase algorithm.
After the device accepts an Erase Suspend command, the device enters the Erase Suspend mode.
The system can read array data using the standard
read timings, except that if it reads at an address
within erase-suspended sectors, the device outputs
status data. After completing a programming operation in the Erase Suspend mode, the system may
once again read array data with the same exception.
See “Erase Suspend/Erase Resume Commands” for
more information on this mode.
The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high,
or while in the autoselect mode. See the “Reset Command” section, next.
See also “Requirements for Reading Array Data” in the
“Device Bus Operations” section for more information.
The Read Operations table provides the read parameters, and Figure 12 shows the timing diagram.
Reset Command
Writing the reset command to the device resets the device to reading array data. Address bits are don’t care
for this command.
The reset command may be written between the sequence cycles in an erase command sequence before
erasing begins. This resets the device to reading array
data. Once erasure begins, however, the device ignores reset commands until the operation is complete.
The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to
reading array data (also applies to programming in
Erase Suspend mode). Once programming begins,
however, the device ignores reset commands until the
operation is complete.
The autoselect command sequence allows the host
system to access the manufacturer and devices codes,
and determine whether or not a sector is protected.
Table 4 shows the address and data requirements. This
method is an alternative to that shown in Table 3, which
is intended for PROM programmers and requires VID
on address bit A9.
The autoselect command sequence is initiated by writing two unlock cycles, followed by the autoselect command. The device then enters the autoselect mode,
and the system may read at any address any number
of times, without initiating another command sequence.
A read cycle at address XX00h retrieves the manufacturer code. A read cycle at address XX01h returns the
device code. A read cycle containing a sector address
(SA) and the address 02h in it, returns 01h if that sector is protected, or 00h if it is unprotected. Refer to
Table 2 for valid sector addresses.
The system must write the reset command to exit the
autoselect mode and return to reading array data.
Byte Program Command Sequence
Programming is a four-bus-cycle operation. The program command sequence is initiated by writing two unlock write cycles, followed by the program set-up
command. The program address and data are written
next, which in turn initiate the Embedded Program algorithm. The system is not required to provide further
controls or timings. The device automatically provides
internally generated program pulses and verify the programmed cell margin. Table 4 shows the address and
data requirements for the byte program command sequence.
When the Embedded Program algorithm is complete,
the device then returns to reading array data and addresses are no longer latched. The system can determine the status of the program operation by using DQ7,
DQ6, or RY/BY#. See “Write Operation Status” for information on these status bits.
Any commands written to the device during the Embedded Program Algorithm are ignored. Note that a
Am29LV081
11
P R E L I M I N A R Y
hardware reset immediately terminates the programming operation. The program command sequence
should be reinitiated once the device has reset to reading array data, to ensure data integrity.
Programming is allowed in any sequence and across
sector boundaries. A bit cannot be programmed
from a “0” back to a “1”. Attempting to do so may halt
the operation and set DQ5 to “1”, or cause the Data#
Polling algorithm to indicate the operation was successful. However, a succeeding read will show that the
data is still “0”. Only erase operations can convert a “0”
to a “1”.
Figure 2 illustrates the algorithm for the program operation. See the Erase/Program Operations table in “AC
Characteristics” for parameters, and to Figure 14 for
timing diagrams.
Figure 3 illustrates the algorithm for the erase operation. See the Erase/Program Operations tables in “AC
Characteristics” for parameters, and to Figure 15 for
timing diagrams.
Write Program
Command Sequence
Data Poll
from System
Sector Erase Command Sequence
Verify Data?
No
Yes
Increment Address
No
Last Address?
Programming
Completed
20977C-5
Note: See Table 4 for program command sequence.
Program Operation
Chip Erase Command Sequence
Chip erase is a six bus cycle operation. The chip erase
command sequence is initiated by writing two unlock
cycles, followed by a set-up command. Two additional
12
Sector erase is a six bus cycle operation. The sector
erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the
address of the sector to be erased, and the sector
erase command. Table 4 shows the address and data
requirements for the sector erase command sequence.
The device does not require the system to preprogram
the memory prior to erase. The Embedded Erase algorithm automatically programs and verifies the sector for
an all zero data pattern prior to electrical erase. The
system is not required to provide any controls or timings during these operations.
Yes
Figure 2.
Any commands written to the chip during the Embedded Erase algorithm are ignored. Note that a hardware
reset during the chip erase operation immediately terminates the operation. The Chip Erase command sequence should be reinitiated once the device has
returned to reading array data, to ensure data integrity.
The system can determine the status of the erase operation by using DQ7, DQ6, DQ2, or RY/BY#. See
“Write Operation Status” for information on these status bits. When the Embedded Erase algorithm is complete, the device returns to reading array data and
addresses are no longer latched.
START
Embedded
Program
algorithm
in progress
unlock write cycles are then followed by the chip erase
command, which in turn invokes the Embedded Erase
algorithm. The device does not require the system to
preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire
memory for an all zero data pattern prior to electrical
erase. The system is not required to provide any controls or timings during these operations. Table 4 shows
the address and data requirements for the chip erase
command sequence.
After the command sequence is written, a sector erase
time-out of 50 µs begins. During the time-out period,
additional sector addresses and sector erase commands may be written. Loading the sector erase buffer
may be done in any sequence, and the number of sectors may be from one sector to all sectors. The time between these additional cycles must be less than 50 µs,
otherwise the last address and command might not be
accepted, and erasure may begin. It is recommended
that processor interrupts be disabled during this time to
ensure all commands are accepted. The interrupts can
be re-enabled after the last Sector Erase command is
written. If the time between additional sector erase
commands can be assumed to be less than 50 µs, the
Am29LV081
P R E L I M I N A R Y
system need not monitor DQ3. Any command other
than Sector Erase or Erase Suspend during the
time-out period resets the device to reading array
data. The system must rewrite the command sequence
and any additional sector addresses and commands.
The system can monitor DQ3 to determine if the sector
erase timer has timed out. (See the “DQ3: Sector Erase
Timer” section.) The time-out begins from the rising
edge of the final WE# pulse in the command sequence.
Once the sector erase operation has begun, only the
Erase Suspend command is valid. All other commands
are ignored. Note that a hardware reset during the
sector erase operation immediately terminates the operation. The Sector Erase command sequence should
be reinitiated once the device has returned to reading
array data, to ensure data integrity.
When the Embedded Erase algorithm is complete, the
device returns to reading array data and addresses are
no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, DQ2, or
RY/BY#. Refer to “Write Operation Status” for information on these status bits.
Figure 3 illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in
the “AC Characteristics” section for parameters, and to
Figure 15 for timing diagrams.
if a sector is actively erasing or is erase-suspended.
See “Write Operation Status” for information on these
status bits.
After an erase-suspended program operation is complete, the system can once again read array data within
non-suspended sectors. The system can determine
the status of the program operation using the DQ7 or
DQ6 status bits, just as in the standard program operation. See “Write Operation Status” for more information.
The system may also write the autoselect command
sequence when the device is in the Erase Suspend
mode. The device allows reading autoselect codes
even at addresses within erasing sectors, since the
codes are not stored in the memory array. When the
device exits the autoselect mode, the device reverts to
the Erase Suspend mode, and is ready for another
valid operation. See “Autoselect Command Sequence”
for more information.
The system must write the Erase Resume command
(address bits are “don’t care”) to exit the erase suspend
mode and continue the sector erase operation. Further
writes of the Resume command are ignored. Another
Erase Suspend command can be written after the device has resumed erasing.
Erase Suspend/Erase Resume Commands
START
The Erase Suspend command allows the system to interrupt a sector erase operation and then read data
from, or program data to, any sector not selected for
erasure. This command is valid only during the sector
erase operation, including the 50 µs time-out period
during the sector erase command sequence. The
Erase Suspend command is ignored if written during
the chip erase operation or Embedded Program algorithm. Writing the Erase Suspend command during the
Sector Erase time-out immediately terminates the
time-out period and suspends the erase operation. Addresses are “don’t-cares” when writing the Erase Suspend command.
Write Erase
Command Sequence
Data Poll
from System
No
When the Erase Suspend command is written during a
sector erase operation, the device requires a maximum
of 20 µs to suspend the erase operation. However,
when the Erase Suspend command is written during
the sector erase time-out, the device immediately terminates the time-out period and suspends the erase
operation.
After the erase operation has been suspended, the
system can read array data from or program data to
any sector not selected for erasure. (The device “erase
suspends” all sectors selected for erasure.) Normal
read and write timings and command definitions apply.
Reading at any address within erase-suspended sectors produces status data on DQ7–DQ0. The system
can use DQ7, or DQ6 and DQ2 together, to determine
Embedded
Erase
algorithm
in progress
Data = FFh?
Yes
Erasure Completed
20977C-6
Notes:
1. See Table 4 for erase command sequence.
2. See “DQ3: Sector Erase Timer” for more information.
Am29LV081
Figure 3.
Erase Operation
13
P R E L I M I N A R Y
Table 4.
Read (Note 5)
Reset (Note 6)
Bus Cycles (Notes 2-4)
Cycles
Command
Sequence
(Note 1)
Am29LV081 Command Definitions
Addr
Data
1
RA
RD
First
Second
Third
Addr
Data
Addr
Fourth
Data Addr
Data
Fifth
Sixth
Addr Data
Addr
Data
1
XXX
F0
4
XXX
AA
XXX
55
XXX
90
X00
01
AutoDevice ID
select
(Note 7) Sector Protect Verify
(Note 8)
4
XXX
AA
XXX
55
XXX
90
X01
38
90
(SA)
X02
00
01
Program
4
XXX
AA
XXX
55
XXX
A0
PA
PD
Chip Erase
6
XXX
AA
XXX
55
XXX
80
XXX
AA
XXX
55
XXX
10
XXX
55
XXX
80
XXX
AA
XXX
55
SA
30
Manufacturer ID
4
XXX
XXX
XXX
AA
Sector Erase
6
XXX
AA
Erase Suspend (Note 9)
1
XXX
B0
Erase Resume (Note 10)
1
XXX
30
XXX
55
XXX
XXX
Legend:
X = Don’t care
PD = Data to be programmed at location PA. Data latches on the
rising edge of WE# or CE# pulse, whichever happens first.
RA = Address of the memory location to be read.
SA = Address of the sector to be verified (in autoselect mode) or
erased. Address bits A19–A13 uniquely select any sector.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed.
Addresses latch on the falling edge of the WE# or CE# pulse,
whichever happens later.
Notes:
1. See Table 1 for description of bus operations.
7. The fourth cycle of the autoselect command sequence is a
read cycle.
2. All values are in hexadecimal.
3. Except when reading array or autoselect data, all bus cycles
are write operations.
4. All address bits are don’t cares for unlock and command
cycles, except when SA or PA required.
5. No unlock or command cycles required when reading array
data.
6. The Reset command is required to return to reading array
data when device is in the autoselect mode, or if DQ5 goes
high (while the device is providing status data).
14
8. The data is 00h for an unprotected sector and 01h for a
protected sector. See “Autoselect Command Sequence” for
more information.
9. The system may read and program in non-erasing sectors, or
enter the autoselect mode, when in the Erase Suspend
mode. The Erase Suspend command is valid only during a
sector erase operation.
10. The Erase Resume command is valid only during the Erase
Suspend mode.
Am29LV081
P R E L I M I N A R Y
WRITE OPERATION STATUS
The device provides several bits to determine the status of a write operation: DQ2, DQ3, DQ5, DQ6, DQ7,
and RY/BY#. Table 5 and the following subsections describe the functions of these bits. DQ7, RY/BY#, and
DQ6 each offer a method for determining whether a
program or erase operation is complete or in progress.
These three bits are discussed first.
Table 5 shows the outputs for Data# Polling on DQ7.
Figure 4 shows the Data# Polling algorithm.
START
DQ7: Data# Polling
Read DQ7–DQ0
Addr = VA
The Data# Polling bit, DQ7, indicates to the host system
whether an Embedded Algorithm is in progress or completed, or whether the device is in Erase Suspend.
Data# Polling is valid after the rising edge of the final
WE# pulse in the program or erase command sequence.
During the Embedded Program algorithm, the device
outputs on DQ7 the complement of the datum programmed to DQ7. This DQ7 status also applies to programming during Erase Suspend. When the
Embedded Program algorithm is complete, the device
outputs the datum programmed to DQ7. The system
must provide the program address to read valid status
information on DQ7. If a program address falls within a
protected sector, Data# Polling on DQ7 is active for approximately 1 µs, then the device returns to reading
array data.
DQ7 = Data?
No
No
When the system detects DQ7 has changed from the
complement to true data, it can read valid data at DQ7–
DQ0 on the following read cycles. This is because DQ7
may change asynchronously with DQ0–DQ6 while
Output Enable (OE#) is asserted low. Figure 16, Data#
Polling Timings (During Embedded Algorithms), in the
“AC Characteristics” section illustrates this.
DQ5 = 1?
Yes
Read DQ7–DQ0
Addr = VA
During the Embedded Erase algorithm, Data# Polling
produces a “0” on DQ7. When the Embedded Erase algorithm is complete, or if the device enters the Erase
Suspend mode, Data# Polling produces a “1” on DQ7.
This is analogous to the complement/true datum output
described for the Embedded Program algorithm: the
erase function changes all the bits in a sector to “1”;
prior to this, the device outputs the “complement,” or
“0.” The system must provide an address within any of
the sectors selected for erasure to read valid status information on DQ7.
After an erase command sequence is written, if all sectors selected for erasing are protected, Data# Polling
on DQ7 is active for approximately 100 µs, then the device returns to reading array data. If not all selected
sectors are protected, the Embedded Erase algorithm
erases the unprotected sectors, and ignores the selected sectors that are protected.
Yes
DQ7 = Data?
Yes
No
FAIL
PASS
Notes:
1. VA = Valid address for programming. During a sector
erase operation, a valid address is an address within any
sector selected for erasure. During chip erase, a valid
address is any non-protected sector address.
2. DQ7 should be rechecked even if DQ5 = “1” because
DQ7 may change simultaneously with DQ5.
Am29LV081
20977C-7
Figure 4.
Data# Polling Algorithm
15
P R E L I M I N A R Y
RY/BY#: Ready/Busy#
The RY/BY# is a dedicated, open-drain output pin that
indicates whether an Embedded Algorithm is in
progress or complete. The RY/BY# status is valid after
the rising edge of the final WE# pulse in the command
sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a
pull-up resistor to VCC.
If the output is low (Busy), the device is actively erasing
or programming. (This includes programming in the
Erase Suspend mode.) If the output is high (Ready),
the device is ready to read array data (including during
the Erase Suspend mode), or is in the standby mode.
Table 5 shows the outputs for RY/BY#. Figures 12, 13,
14 and 15 shows RY/BY# for read, reset, program, and
erase operations, respectively.
DQ6: Toggle Bit I
Toggle Bit I on DQ6 indicates whether an Embedded
Program or Erase algorithm is in progress or complete,
or whether the device has entered the Erase Suspend
mode. Toggle Bit I may be read at any address, and is
valid after the rising edge of the final WE# pulse in the
command sequence (prior to the program or erase operation), and during the sector erase time-out.
During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause
DQ6 to toggle. (The system may use either OE# or
CE# to control the read cycles.) When the operation is
complete, DQ6 stops toggling.
After an erase command sequence is written, if all sectors selected for erasing are protected, DQ6 toggles for
approximately 100 µs, then returns to reading array
data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are
protected.
The system can use DQ6 and DQ2 together to determine whether a sector is actively erasing or is erasesuspended. When the device is actively erasing (that is,
the Embedded Erase algorithm is in progress), DQ6
toggles. When the device enters the Erase Suspend
mode, DQ6 stops toggling. However, the system must
also use DQ2 to determine which sectors are erasing
or erase-suspended. Alternatively, the system can use
DQ7 (see the subsection on “DQ7: Data# Polling”).
If a program address falls within a protected sector,
DQ6 toggles for approximately 1 µs after the program
command sequence is written, then returns to reading
array data.
DQ6 also toggles during the erase-suspend-program
mode, and stops toggling once the Embedded Program algorithm is complete.
16
Table 5 shows the outputs for Toggle Bit I on DQ6.
Refer to Figure 5 for the toggle bit algorithm, and to the
Figure 17 in the “AC Characteristics” section for the
timing diagram. Figure 18 shows the differences between DQ2 and DQ6 in graphical form. See also the
subsection on “DQ2: Toggle Bit II”.
DQ2: Toggle Bit II
The “Toggle Bit II” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing
(that is, the Embedded Erase algorithm is in progress),
or whether that sector is erase-suspended. Toggle Bit
II is valid after the rising edge of the final WE# pulse in
the command sequence.
DQ2 toggles when the system reads at addresses
within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish
whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the
device is actively erasing, or is in Erase Suspend, but
cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and
mode information. Refer to Table 5 to compare outputs
for DQ2 and DQ6.
Figure 5 shows the toggle bit algorithm in flowchart
form, and the section “DQ2: Toggle Bit II” explains the
algorithm. See also the “DQ6: Toggle Bit I” subsection.
Refer to Figure 17 for the toggle bit timing diagram. Figure 18 shows the differences between DQ2 and DQ6 in
graphical form.
Reading Toggle Bits DQ6/DQ2
Refer to Figure 5 for the following discussion. Whenever
the system initially begins reading toggle bit status, it
must read DQ7–DQ0 at least twice in a row to determine
whether a toggle bit is toggling. Typically, the system
would note and store the value of the toggle bit after the
first read. After the second read, the system would compare the new value of the toggle bit with the first. If the
toggle bit is not toggling, the device has completed the
program or erase operation. The system can read array
data on DQ7–DQ0 on the following read cycle.
However, if after the initial two read cycles, the system
determines that the toggle bit is still toggling, the system also should note whether the value of DQ5 is high
(see the section on DQ5). If it is, the system should
then determine again whether the toggle bit is toggling,
since the toggle bit may have stopped toggling just as
DQ5 went high. If the toggle bit is no longer toggling,
the device has successfully completed the program or
erase operation. If it is still toggling, the device did not
completed the operation successfully, and the system
must write the reset command to return to reading
array data.
Am29LV081
P R E L I M I N A R Y
The remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5 has not
gone high. The system may continue to monitor the
toggle bit and DQ5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to perform other
system tasks. In this case, the system must start at the
beginning of the algorithm when it returns to determine
the status of the operation (top of Figure 5).
START
(Note 1)
After writing a sector erase command sequence, the
system may read DQ3 to determine whether or not an
erase operation has begun. (The sector erase timer
does not apply to the chip erase command.) If additional
sectors are selected for erasure, the entire time-out also
applies after each additional sector erase command.
When the time-out is complete, DQ3 switches from “0”
to “1.” The system may ignore DQ3 if the system can
guarantee that the time between additional sector
erase commands will always be less than 50 µs. See
also the “Sector Erase Command Sequence” section.
No
Yes
DQ5 = 1?
After the sector erase command sequence is written,
the system should read the status on DQ7 (Data# Polling) or DQ6 (Toggle Bit I) to ensure the device has accepted the command sequence, and then read DQ3. If
DQ3 is “1”, the internally controlled erase cycle has begun; all further commands (other than Erase Suspend)
are ignored until the erase operation is complete. If
DQ3 is “0”, the device will accept additional sector
erase commands. To ensure the command has been
accepted, the system software should check the status
of DQ3 prior to and following each subsequent sector
erase command. If DQ3 is high on the second status
check, the last command might not have been accepted. Table 5 shows the outputs for DQ3.
Yes
Read DQ7–DQ0
Twice
Toggle Bit
= Toggle?
(Notes
1, 2)
No
Yes
Program/Erase
Operation Not
Complete, Write
Reset Command
The DQ5 failure condition may appear if the system
tries to program a “1” to a location that is previously
programmed to “0.” Only an erase operation can
change a “0” back to a “1.” Under this condition, the
device halts the operation, and when the operation has
exceeded the timing limits, DQ5 produces a “1.”
DQ3: Sector Erase Timer
Read DQ7–DQ0
No
DQ5 indicates whether the program or erase time has
exceeded a specified internal pulse count limit. Under
these conditions DQ5 produces a “1.” This is a failure
condition that indicates the program or erase cycle was
not successfully completed.
Under both these conditions, the system must issue
the reset command to return the device to reading
array data.
Read DQ7–DQ0
Toggle Bit
= Toggle?
DQ5: Exceeded Timing Limits
Program/Erase
Operation Complete
Notes:
1. Read toggle bit twice to determine whether or not it is
toggling. See text.
2. Recheck toggle bit because it may stop toggling as DQ5
changes to “1” . See text.
20977C-8
Figure 5.
Toggle Bit Algorithm
Am29LV081
17
P R E L I M I N A R Y
Table 5.
DQ7
(Note 2)
DQ6
DQ5
(Note 1)
DQ3
DQ2
(Note 2)
RY/BY#
DQ7#
Toggle
0
N/A
No toggle
0
Embedded Erase Algorithm
0
Toggle
0
1
Toggle
0
Reading within Erase
Suspended Sector
1
No toggle
0
N/A
Toggle
1
Reading within Non-Erase
Suspended Sector
Data
Data
Data
Data
Data
1
Erase-Suspend-Program
DQ7#
Toggle
0
N/A
N/A
0
Operation
Standard
Mode
Erase
Suspend
Mode
Write Operation Status
Embedded Program Algorithm
Notes:
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits.
See “DQ5: Exceeded Timing Limits” for more information.
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details.
18
Am29LV081
P R E L I M I N A R Y
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +150°C
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –65°C to +125°C
Voltage with Respect to Ground
20 ns
20 ns
+0.8 V
VCC (Note 1) . . . . . . . . . . . . . . . .–0.5 V to +4.0 V
A9, OE#, and
RESET# (Note 2). . . . . . . . . . . . –0.5 V to +12.5 V
–0.5 V
–2.0 V
All other pins (Note 1) . . . . . –0.5 V to VCC+0.5 V
20 ns
Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V. During
voltage transitions, input or I/O pins may undershoot VSS
to –2.0 V for periods of up to 20 ns. See Figure 6.
Maximum DC voltage on input or I/O pins is VCC +0.5 V.
During voltage transitions, input or I/O pins may overshoot
to VCC +2.0 V for periods up to 20 ns. See Figure 7.
2. Minimum DC input voltage on pins A9, OE#, and RESET#
is –0.5 V. During voltage transitions, A9, OE#, and
RESET# may undershoot VSS to –2.0 V for periods of up
to 20 ns. See Figure 6. Maximum DC input voltage on pin
A9 is +12.5 V which may overshoot to 14.0 V for periods
up to 20 ns.
3. No more than one output may be shorted to ground at a
time. Duration of the short circuit should not be greater
than one second.
20977C-9
Figure 6.
Maximum Negative Overshoot
Waveform\
20 ns
VCC
+2.0 V
VCC
+0.5 V
2.0 V
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This is
a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to absolute maximum rating
conditions for extended periods may affect device reliability.
20 ns
20 ns
20977C-10
Figure 7.
Maximum Positive Overshoot
Waveform
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (TA) . . . . . . . . . . . 0°C to +70°C
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . –40°C to +85°C
Extended (E) Devices
Ambient Temperature (TA) . . . . . . . . –55°C to +125°C
VCC Supply Voltages
VCC for regulated voltage range. . . . .+3.0 V to +3.6 V
VCC for full voltage range . . . . . . . . . .+2.7 V to +3.6 V
Operating ranges define those limits between which the functionality of the device is guaranteed.
Am29LV081
19
P R E L I M I N A R Y
DC CHARACTERISTICS
CMOS Compatible
Parameter
Description
Test Conditions
Min
ILI
Input Load Current
VIN = VSS to VCC,
VCC = VCC max
ILIT
A9 Input Load Current
VCC = VCC max; A9 = 12.5 V
ILO
Output Leakage Current
VOUT = VSS to VCC,
VCC = VCC max
ICC1
VCC Active Read Current
(Note 1)
CE# = VIL, OE# = VIH
ICC2
VCC Active Write Current
(Notes 2 and 4)
ICC3
Typ
Unit
±1.0
µA
35
µA
±1.0
µA
5 MHz
10
16
1 MHz
2
4
CE# = VIL, OE# = VIH
20
30
mA
VCC Standby Current
VCC = VCC max;
CE#, RESET# = VCC±0.3 V
0.2
5
µA
ICC4
VCC Standby Current During Reset
VCC = VCC max;
RESET# = VSS ± 0.3 V
0.2
5
µA
ICC5
Automatic Sleep Mode (Note 3)
VIH = VCC ± 0.3 V;
VIL = VSS ± 0.3 V
0.2
5
µA
VIL
Input Low Voltage
–0.5
0.8
V
VIH
Input High Voltage
0.7 x VCC
VCC + 0.3
V
VID
Voltage for Autoselect and
Temporary Sector Unprotect
VCC = 3.3 V
11.5
12.5
V
VOL
Output Low Voltage
IOL = 4.0 mA, VCC = VCC min
0.45
V
VOH1
Output High Voltage
VOH2
VLKO
mA
IOH = –2.0 mA, VCC = VCC min
0.85 VCC
IOH = –100 µA, VCC = VCC min
VCC–0.4
Low VCC Lock-Out Voltage (Note 4)
2.3
Notes:
1. The ICC current listed is typically less than 2 mA/MHz, with OE# at VIH. Typical VCC is 3.0 V.
2. ICC active while Embedded Erase or Embedded Program is in progress.
3. Automatic sleep mode enables the low power mode when addresses remain stable for tACC + 30 ns.
4. Not 100% tested.
20
Max
Am29LV081
V
2.5
V
P R E L I M I N A R Y
DC CHARACTERISTICS (Continued)
Zero Power Flash
Supply Current in mA
25
20
15
10
5
0
0
500
1000
1500
2000
2500
3000
3500
4000
Time in ns
Note: Addresses are switching at 1 MHz
20977C-11
Figure 8.
ICC1 Current vs. Time (Showing Active and Automatic Sleep Currents)
Supply Current in mA
15
10
3.6
V
2 .7 V
5
0
1
2
3
4
5
Frequency in MHz
Note: T = 25 °C
20977C-12
Figure 9.
Typical ICC1 vs. Frequency
Am29LV081
21
P R E L I M I N A R Y
TEST CONDITIONS
Table 6.
Test Specifications
3.3 V
-90R,
-100
Test Condition
2.7 kΩ
Device
Under
Test
CL
Output Load
-120,
-150
Unit
1 TTL gate
Output Load Capacitance, CL
(including jig capacitance)
30
100
pF
6.2 kΩ
Input Rise and Fall Times
5
ns
0.0–3.0
V
Input timing measurement
reference levels
1.5
V
Output timing measurement
reference levels
1.5
V
Input Pulse Levels
Note: Diodes are IN3064 or equivalent
20977C-13
Figure 10.
Test Setup
KEY TO SWITCHING WAVEFORMS
WAVEFORM
INPUTS
OUTPUTS
Steady
Changing from H to L
Changing from L to H
Don’t Care, Any Change Permitted
Changing, State Unknown
Does Not Apply
Center Line is High Impedance State (High Z)
KS000010-PAL
3.0 V
Input
1.5 V
Measurement Level
1.5 V
Output
0.0 V
20977C-14
Figure 11.
22
Input Waveforms and Measurement Levels
Am29LV081
P R E L I M I N A R Y
AC CHARACTERISTICS
Read Operations
Parameter
Speed Option
JEDEC
Std
tAVAV
tRC
Read Cycle Time (Note 1)
tAVQV
tACC
Address to Output Delay
tELQV
tCE
Chip Enable to Output Delay
tGLQV
tOE
tEHQZ
tGHQZ
tAXQX
Description
Test Setup
-90R
-100
-120
-150
Unit
Min
90
100
120
150
ns
CE# = VIL
OE# = VIL
Max
90
100
120
150
ns
OE# = VIL
Max
90
100
120
150
ns
Output Enable to Output Delay
Max
40
40
50
55
ns
tDF
Chip Enable to Output High Z (Note 1)
Max
30
30
30
40
ns
tDF
Output Enable to Output High Z (Note 1)
Max
30
30
30
40
ns
Read
Min
0
ns
Toggle and
Data# Polling
Min
10
ns
Min
0
ns
tOEH
Output Enable
Hold Time (Note 1)
tOH
Output Hold Time From Addresses, CE# or
OE#, Whichever Occurs First (Note 1)
Notes:
1. Not 100% tested.
2. See Figure 10 and Table 6 for test specifications.
tRC
Addresses Stable
Addresses
tACC
CE#
tDF
tOE
OE#
tOEH
WE#
tCE
tOH
HIGH Z
HIGH Z
Output Valid
Outputs
RESET#
RY/BY#
0V
20977C-15
Figure 12.
Read Operations Timings
Am29LV081
23
P R E L I M I N A R Y
AC CHARACTERISTICS
Hardware Reset (RESET#)
Parameter
JEDEC
Std
Description
Test Setup
All Speed Options
Unit
tREADY
RESET# Pin Low (During Embedded
Algorithms) to Read or Write (See Note)
Max
20
µs
tREADY
RESET# Pin Low (NOT During Embedded
Algorithms) to Read or Write (See Note)
Max
500
ns
tRP
RESET# Pulse Width
Min
500
ns
tRH
RESET# High Time Before Read (See Note)
Min
50
ns
tRPD
RESET# Low to Standby Mode
Min
20
µs
tRB
RY/BY# Recovery Time
Min
0
ns
Note: Not 100% tested.
RY/BY#
CE#, OE#
tRH
RESET#
tRP
tReady
Reset Timings NOT during Embedded Algorithms
Reset Timings during Embedded Algorithms
tReady
RY/BY#
tRB
CE#, OE#
RESET#
tRP
20977C-16
Figure 13.
24
RESET# Timings
Am29LV081
P R E L I M I N A R Y
AC CHARACTERISTICS
Erase/Program Operations
Parameter
JEDEC
Std
Description
-90R
-100
-120
-150
Unit
tAVAV
tWC
Write Cycle Time (Note 1)
Min
90
100
120
150
ns
tAVWL
tAS
Address Setup Time
Min
tWLAX
tAH
Address Hold Time
Min
50
50
50
65
ns
tDVWH
tDS
Data Setup Time
Min
50
50
50
65
ns
tWHDX
tDH
Data Hold Time
Min
0
ns
tOES
Output Enable Setup Time
Min
0
ns
Read Recovery Time Before Write
(OE# High to WE# Low)
Min
0
ns
0
ns
tGHWL
tGHWL
tELWL
tCS
CE# Setup Time
Min
0
ns
tWHEH
tCH
CE# Hold Time
Min
0
ns
tWLWH
tWP
Write Pulse Width
Min
50
50
50
65
ns
tWHWL
tWPH
Write Pulse Width High
Min
30
30
30
35
ns
tWHWH1
tWHWH1 Programming Operation (Note 2)
Typ
9
µs
tWHWH2
tWHWH2 Sector Erase Operation (Note 2)
Typ
1
sec
tVCS
VCC Setup Time (Note 1)
Min
50
µs
tRB
Recovery Time from RY/BY#
Min
0
ns
Program/Erase Valid to RY/BY# Delay
Min
90
ns
tBUSY
Notes:
1. Not 100% tested.
2. See the “Erase and Programming Performance” section for more information.
Am29LV081
25
P R E L I M I N A R Y
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
tAS
tWC
Addresses
Read Status Data (last two cycles)
XXXh
PA
PA
PA
tAH
CE#
tCH
tGHWL
OE#
tWHWH1
tWP
WE#
tWPH
tCS
tDS
tDH
A0h
Data
PD
Status
tBUSY
DOUT
tRB
RY/BY#
VCC
tVCS
Note: PA = program address, PD = program data, DOUT is the true data at the program address.
20977C-17
Figure 14.
26
Program Operation Timings
Am29LV081
P R E L I M I N A R Y
AC CHARACTERISTICS
Erase Command Sequence (last two cycles)
tAS
tWC
XXXh
Addresses
Read Status Data
VA
SA
VA
555h for chip erase
tAH
CE#
tGHWL
tCH
OE#
tWP
WE#
tWPH
tCS
tWHWH2
tDS
tDH
Data
55h
In
Progress
30h
Complete
10 for Chip Erase
tBUSY
tRB
RY/BY#
tVCS
VCC
Note: SA = sector address (for Sector Erase), VA = Valid Address for reading status data (see “Write Operation Status”).
20977C-18
Figure 15.
Chip/Sector Erase Operation Timings
Am29LV081
27
P R E L I M I N A R Y
AC CHARACTERISTICS
tRC
Addresses
VA
VA
VA
tACC
tCE
CE#
tCH
tOE
OE#
tOEH
tDF
WE#
tOH
High Z
DQ7
Complement
Complement
DQ0–DQ6
Status Data
Status Data
Valid Data
True
High Z
Valid Data
True
tBUSY
RY/BY#
Note: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data
read cycle.
20977C-19
Figure 16.
Data# Polling Timings (During Embedded Algorithms)
tRC
Addresses
VA
VA
VA
VA
tACC
tCE
CE#
tCH
tOE
OE#
tOEH
tDF
WE#
tOH
High Z
DQ6/DQ2
tBUSY
Valid Status
Valid Status
(first read)
(second read)
Valid Status
Valid Data
(stops toggling)
RY/BY#
Note: VA = Valid address; not required for DQ6. Illustration shows first two status cycle after command sequence, last status read
cycle, and array data read cycle.
20977C-20
Figure 17.
28
Toggle Bit Timings (During Embedded Algorithms)
Am29LV081
P R E L I M I N A R Y
AC CHARACTERISTICS
Enter
Embedded
Erasing
Erase
Suspend
Erase
WE#
Enter Erase
Suspend Program
Erase
Resume
Erase
Suspend
Program
Erase Suspend
Read
Erase
Erase Suspend
Read
Erase
Complete
DQ6
DQ2
Note: The system may use CE# or OE# to toggle DQ2 and DQ6. DQ2 toggles only when read at an address within an
erase-suspended sector.
20977C-21
Figure 18.
DQ2 vs. DQ6
Temporary Sector Unprotect
Parameter
JEDEC
Std
Description
All Speed Options
Unit
tVIDR
VID Rise and Fall Time (See Note)
Min
500
ns
tRSP
RESET# Setup Time for Temporary Sector
Unprotect
Min
4
µs
Note: Not 100% tested.
12 V
RESET#
0 or 3 V
0 or 3 V
tVIDR
tVIDR
Program or Erase Command Sequence
CE#
WE#
tRSP
RY/BY#
20977C-22
Figure 19.
Temporary Sector Unprotect Timing Diagram
Am29LV081
29
P R E L I M I N A R Y
AC CHARACTERISTICS
Alternate CE# Controlled Erase/Program Operations
Parameter
JEDEC
Std
Description
tAVAV
tWC
Write Cycle Time (Note 1)
Min
tAVEL
tAS
Address Setup Time
Min
tELAX
tAH
Address Hold Time
Min
50
50
50
65
ns
tDVEH
tDS
Data Setup Time
Min
50
50
50
65
ns
tEHDX
tDH
Data Hold Time
Min
0
ns
tOES
Output Enable Setup Time
Min
0
ns
tGHEL
tGHEL
Read Recovery Time Before Write
(OE# High to WE# Low)
Min
0
ns
tWLEL
tWS
WE# Setup Time
Min
0
ns
tEHWH
tWH
WE# Hold Time
Min
0
ns
tELEH
tCP
CE# Pulse Width
Min
50
50
50
65
ns
tEHEL
tCPH
CE# Pulse Width High
Min
30
30
30
35
ns
tWHWH1
tWHWH1
Programming Operation (Note 2)
Typ
9
µs
tWHWH2
tWHWH2
Sector Erase Operation (Note 2)
Typ
1
sec
Notes:
1. Not 100% tested.
2. See the “Erase and Programming Performance” section for more information.
30
Am29LV081
-90R
-100
-120
-150
Unit
90
100
120
150
ns
0
ns
P R E L I M I N A R Y
AC CHARACTERISTICS
XXX for program
XXX for erase
PA for program
SA for sector erase
XXX for chip erase
Data# Polling
Addresses
PA
tWC
tAS
tAH
tWH
WE#
tGHEL
OE#
tWHWH1 or 2
tCP
CE#
tWS
tCPH
tBUSY
tDS
tDH
DQ7#
Data
tRH
A0 for program
55 for erase
DOUT
PD for program
30 for sector erase
10 for chip erase
RESET#
RY/BY#
Notes:
1. PA = program address, PD = program data, DQ7# = complement of the data written to the device, DOUT = data written to the
device, XXX = address don’t care.
2. Figure indicates the last two bus cycles of the command sequence.
20977C-23
Figure 20.
Alternate CE# Controlled Write Operation Timings
Am29LV081
31
P R E L I M I N A R Y
ERASE AND PROGRAMMING PERFORMANCE
Parameter
Typ (Note 1)
Max (Note 2)
Unit
Sector Erase Time
1
15
s
Chip Erase Time
16
Byte Programming Time
9
Chip Programming Time
s
300
9
(Note 3)
Comments
Excludes 00h programming
prior to erasure (Note 4)
µs
27
s
Excludes system level
overhead (Note 5)
Notes:
1. Typical program and erase times assume the following conditions: 25°C, 3.0 V VCC, 100,000 cycles. Additionally,
programming typicals assume checkerboard pattern.
2. Under worst case conditions of 90°C, VCC = 2.7 V, 100,000 cycles.
3. The typical chip programming time is considerably less than the maximum chip programming time listed, since most bytes
program faster than the maximum program times listed.
4. In the pre-programming step of the Embedded Erase algorithm, all bytes are programmed to 00h before erasure.
5. System-level overhead is the time required to execute the four-bus-cycle sequence for the program command. See Table 4
for further information on command definitions.
6. The device has a typical erase and program cycle endurance of 1,000,000 cycles. 100,000 cycles are guaranteed.
LATCHUP CHARACTERISTICS
Description
Min
Max
Input voltage with respect to VSS on all pins except I/O pins
(including A9, OE#, and RESET#)
–1.0 V
12.5 V
Input voltage with respect to VSS on all I/O pins
–1.0 V
VCC + 1.0 V
–100 mA
+100 mA
VCC Current
Includes all pins except VCC. Test conditions: VCC = 3.0 V, one pin at a time.
TSOP PIN CAPACITANCE
Parameter
Symbol
Parameter Description
Test Setup
Typ
Max
Unit
CIN
Input Capacitance
VIN = 0
6
7.5
pF
COUT
Output Capacitance
VOUT = 0
8.5
12
pF
CIN2
Control Pin Capacitance
VIN = 0
7.5
9
pF
Notes:
1. Sampled, not 100% tested.
2. Test conditions TA = 25°C, f = 1.0 MHz.
DATA RETENTION
Parameter
Test Conditions
Min
Unit
150°C
10
Years
125°C
20
Years
Minimum Pattern Data Retention Time
32
Am29LV081
P R E L I M I N A R Y
PHYSICAL DIMENSIONS
TS 040—40-Pin Standard TSOP (measured in millimeters)
0.95
1.05
Pin 1 I.D.
1
40
9.90
10.10
0.50 BSC
21
20
0.05
0.15
18.30
18.50
19.80
20.20
0.08
0.20
0.10
0.21
1.20
MAX
0˚
5˚
0.50
0.70
16-038-TSOP-1_AE
TS 040
2-27-97 lv
* For reference only. BSC is an ANSI standard for Basic Space Centering.
Am29LV081
33
P R E L I M I N A R Y
PHYSICAL DIMENSIONS
TSR040—40-Pin Reverse TSOP (measured in millimeters)
0.95
1.05
Pin 1 I.D.
1
40
9.90
10.10
0.50 BSC
21
20
0.05
0.15
18.30
18.50
19.80
20.20
0.08
0.20
0.10
0.21
1.20
MAX
0˚
5˚
0.50
0.70
* For reference only. BSC is an ANSI standard for Basic Space Centering.
34
Am29LV081
16-038-TSOP-1_AE
TSR040
2-27-97 lv
P R E L I M I N A R Y
REVISION SUMMARY FOR AM29LV081
100% tested. Corrected the note reference for tVCS.
This parameter is not 100% tested.
Revision C
Figure 14, Program Operation Timings;
Figure 15, Chip/Sector Erase Operation Timings
Global
Revised formatting to be consistent with other current
3.0 volt-only data sheets.
Revision C+1
The first cycle of the addresses waveform should indicate XXXh; that is, addresses are don’t care for that
cycle.
Figure 20, Alternate CE# Controlled Write
Operation Timings
DC Characteristics
Changed Note 1 to indicate that OE# is at VIH for the
listed current.
AC Characteristics
Erase/Program Operations; Alternate CE# Controlled
Erase/Program Operations: Corrected the notes reference for tWHWH1 and tWHWH2. These parameters are
The first cycle of the addresses waveform should indicate XXXh. The second cycle of the waveform should
indicate XXXh for chip erase. Addresses are don’t care
in these cases.
Temporary Sector Unprotect Table
Added note reference for tVIDR. This parameter is not
100% tested.
Trademarks
Copyright © 1998 Advanced Micro Devices, Inc. All rights reserved.
AMD, the AMD logo, and combinations thereof are registered trademarks of Advanced Micro Devices, Inc.
ExpressFlash is a trademark of Advanced Micro Devices, Inc.
Product names used in this publication are for identification purposes only and may be trademarks of their respective companies.
Am29LV081
35