Click on Series name for product info on aimtec.com Series AM4N-Z 4 Watt | DC-DC Converter FEATURES: • • • • Models Single output Model Input Voltage (V) RoHS compliant ±20% Input voltage range Low ripple and noise High efficiency up to 81% Output Voltage (V) • • • • Operating temperature -40oC to + 85oC 5KVAC highest reinforced input/ output isolation Pin compatible with multiple manufacturers Continuous short circuit protection Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) AM4N-0503SH50Z 4-6 3.3 700 5000 470 74 AM4N-0505SH50Z 4-6 5 700 5000 470 78 AM4N-0512SH50Z 4-6 12 291 5000 220 80 AM4N-0515SH50Z 4-6 15 233 5000 220 79 AM4N-1203SH50Z 9.6-14.4 3.3 700 5000 470 76 AM4N-1205SH50Z 9.6-14.4 5 700 5000 470 80 AM4N-1212SH50Z 9.6-14.4 12 291 5000 220 81 AM4N-1215SH50Z 9.6-14.4 15 233 5000 220 81 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating No Load Input Current Input reflected current(pk-pk) Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Nominal Conditions General Specifications Parameters Switching frequency Operating temperature Storage temperature www.aimtec.com F 051e R12.B 115 mA mA Maximum Units ±2 Continuous Autorecovery Typical 570 -40 to +85 (full load without derating) -55 to +125 Tel: +1 514 620 2722 1 of 4 VAC MOhm pF Maximum ±0.2 ±0.5 ±0.02 85 10 20MHz Bandwidth 100% load VDC Typical From 10% to 100% Load Conditions ms 5000 1000 50 Conditions Units VDC Typical 3 sec Parameters Maximum 4-6 9.6-14.4 Capacitors 75 0-7 0-15 80 35 5 Vin 12 Vin Output Specifications Voltage accuracy Short Circuit protection Short circuit restart Short Circuit consumption Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Minimum Load Current Typical 5 12 Maximum Units % W % of Vin % %/oC mV p-p % of Max Units KHz o C o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4N-Z 4 Watt | DC-DC Converter General Specifications (continued) Parameters Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Conditions 1.5mm from case for 10sec Typical 100 None Maximum Units o Natural Convection 95 Non Conductive Black Plastic (UL94V-0 rated) 12.5 1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm > 1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) 260 C %/ oC % RH g o C Safety Specifications Parameters Agency Approvals Standards CE EN 55022 Class A EN 55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 NOTE: also designed to meet IEC 60601-1 Pin Out Specifications Pin 2 3 11 14 16 22 23 Single -V Input -V Input N.C. +V Output -V Output V+ Input V+ Input N.C.: No connection www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4N-Z 4 Watt | DC-DC Converter Dimensions 22.86 (0.90) 0.50 (0.02) 3 20.32 (0.80) 2 11 Bottom View 23 22 16 14 5.08 (0.20) 2.54 (0.10) Printed Face 15.24 (0.60) 31.75 (1.25) Built-in Stand-offs to ease PCB cleaning 3.05 (0.12) 10.16 (0.40) All dimensions are typical: millimeters (inches) Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002) Pin Pitch Tolerance: ± 0.35 (±0.014) Case Tolerence: ± 0.5 (±0.02) EMI Solution C2 L1 +V output +V input C1 DC/DC Converter -V input Load -V output C3 www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4N-Z 4 Watt | DC-DC Converter EFT/Surge Solution +V output +V input DC/DC Converter C1 -V input Load -V output NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only