Click on Series name for product info on aimtec.com Series AM5T-VZ 5 Watt | DC-DC Converter FEATURES: Wide 2:1 input range 24 Pin DIP Package Metal package High efficiency up to 80% Operating temperature -40oC to + 85oC Input / Output isolation 1500 & 3500 VDC Pin compatible with multiple manufacturers Continuous short circuit protection Models Single output Model AM5T-1205S-VZ AM5T-1209S-VZ AM5T-1212S-VZ AM5T-1215S-VZ AM5T-1224S-VZ AM5T-2405S-VZ AM5T-2409S-VZ AM5T-2412S-VZ AM5T-2415S-VZ AM5T-2424S-VZ AM5T-4805S-VZ AM5T-4809S-VZ AM5T-4812S-VZ AM5T-4815S-VZ AM5T-4824S-VZ AM5T-1205SH35-VZ AM5T-1209SH35-VZ AM5T-1212SH35-VZ AM5T-1215SH35-VZ AM5T-1224SH35-VZ AM5T-2405SH35-VZ AM5T-2409SH35-VZ AM5T-2412SH35-VZ AM5T-2415SH35-VZ AM5T-2424SH35-VZ AM5T-4805SH35-VZ AM5T-4809SH35-VZ AM5T-4812SH35-VZ AM5T-4815SH35-VZ AM5T-4824SH35-VZ Input Voltage (V) Output Voltage (V) Output Current max (mA) Capacitive load, max (μF) Efficiency (%) 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 36-72 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 36-72 5 9 12 15 24 5 9 12 15 24 5 9 12 15 24 5 9 12 15 24 5 9 12 15 24 5 9 12 15 24 1000 555 416 333 208 1000 555 416 333 208 1000 555 416 333 208 1000 555 416 333 208 1000 555 416 333 208 1000 555 416 333 208 2200 470 470 470 220 2200 470 470 470 220 2200 470 470 470 220 2200 470 470 470 220 2200 470 470 470 220 2200 470 470 470 220 74 77 78 78 75 75 76 77 78 76 77 78 80 80 77 74 77 78 78 75 75 76 77 78 76 77 78 80 80 77 Input Voltage (V) Output Voltage (V) 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-72 ±5 ±9 ±12 ±15 ±24 ±5 ±9 ±12 ±15 ±24 ±5 Models Dual output Model AM5T-1205D-VZ AM5T-1209D-VZ AM5T-1212D-VZ AM5T-1215D-VZ AM5T-1224D-VZ AM5T-2405D-VZ AM5T-2409D-VZ AM5T-2412D-VZ AM5T-2415D-VZ AM5T-2424D-VZ AM5T-4805D-VZ www.aimtec.com F 051e R12.I Output Current max (mA) ±500 ±277 ±208 ±166 ±104 ±500 ±277 ±208 ±166 ±104 ±500 Tel: +1 514 620 2722 1 of 4 Capacitive load, max (μF) ±1000 ±220 ±220 ±220 ±100 ±1000 ±220 ±220 ±220 ±100 ±1000 Efficiency (%) 72 76 77 77 80 74 76 78 78 75 76 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5T-VZ 5 Watt | DC-DC Converter Models Dual output (continued) Model Input Voltage (V) Output Voltage (V) 36-72 36-72 36-72 36-72 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 36-72 ±9 ±12 ±15 ±24 ±5 ±9 ±12 ±15 ±24 ±5 ±9 ±12 ±15 ±24 ±5 ±9 ±12 ±15 ±24 AM5T-4809D-VZ AM5T-4812D-VZ AM5T-4815D-VZ AM5T-4824D-VZ AM5T-1205DH35-VZ AM5T-1209DH35-VZ AM5T-1212DH35-VZ AM5T-1215DH35-VZ AM5T-1224DH35-VZ AM5T-2405DH35-VZ AM5T-2409DH35-VZ AM5T-2412DH35-VZ AM5T-2415DH35-VZ AM5T-2424DH35-VZ AM5T-4805DH35-VZ AM5T-4809DH35-VZ AM5T-4812DH35-VZ AM5T-4815DH35-VZ AM5T-4824DH35-VZ Output Current max (mA) Capacitive load, max (μF) ±277 ±208 ±166 ±104 ±500 ±277 ±208 ±166 ±104 ±500 ±277 ±208 ±166 ±104 ±500 ±277 ±208 ±166 ±104 Efficiency (%) ±220 ±220 ±220 ±100 ±1000 ±220 ±220 ±220 ±100 ±1000 ±220 ±220 ±220 ±100 ±1000 ±220 ±220 ±220 ±100 78 78 80 77 72 76 77 77 80 74 76 78 78 75 76 78 78 80 77 Maximum Units Input Specifications Parameters Voltage Range Nominal Typical 12 24 48 9-18 18-36 36-72 12 Vin 24 Vin 48 Vin 20 -0.7-24 -0.7-40 -0.7-80 15 (Pi) Network Filter Start up time Absolute Maximum Rating VDC Peak Input Voltage time ms VDC ms Isolation Specifications Parameters Tested I/O voltage Conditions Typical 3 sec Resistance Capacitance Rated Units 1500 (3500 H35 model) VDC > 1000 60 MOhm pF Output Specifications Parameters Voltage accuracy Voltage balance Conditions Typical Maximum ±1 Balanced Load ±1 Short circuit protection Continuous Short circuit restart Auto Recovery Line voltage regulation HL-LL ±0.5 Load voltage regulation 25-100% Load ±0.5 Temperature coefficient ±0.02 Ripple & Noise (see note) At 20MHz Bandwidth 60 Note: For ripple and noise specification, a 100 µF capacitor must be placed on the output of converter. www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 2 of 4 Units % % % % %/oC mV p-p Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5T-VZ 5 Watt | DC-DC Converter General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions(L x W x H) MTBF Conditions Typical Maximum Units 100 KHz oC oC oC 100-400 Full Load (see derating chart) -40 to +85 -40 to +125 Free air convection 95 % Nickel coated copper 12.16 g Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.8 x 0.4 inches 31.75 x 20.32 x 10.16 mm >2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Safety Specifications Parameters Agency approvals CE Standards Designed to meet IEC 60950-1 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Pin Out Specifications Pin 2 3 9 11 14 16 22 23 1500 and 3500VDC Single Dual -V Input -V Input No pin N.C. +V Output -V Output +V Input +V Input -V Input -V Input Common -V Output +V Output Common +V Input +V Input 3.05 (0.12) 10.50 (0.41) 21.35 (0.84) 15.24 (0.60) Dimensions www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5T-VZ 5 Watt | DC-DC Converter Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only