AIMTEC AM6T-2409DH35-VZ 6 watt | dc-dc converter Datasheet

Series AM6T-VZ
6 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Models
Single output
Model
AM6T-1205S-VZ
AM6T-1209S-VZ
AM6T-1212S-VZ
AM6T-1215S-VZ
AM6T-1224S-VZ
AM6T-2405S-VZ
AM6T-2409S-VZ
AM6T-2412S-VZ
AM6T-2415S-VZ
AM6T-2424S-VZ
AM6T-4805S-VZ
AM6T-4809S-VZ
AM6T-4812S-VZ
AM6T-4815S-VZ
AM6T-4824S-VZ
AM6T-1205SH35-VZ
AM6T-1209SH35-VZ
AM6T-1212SH35-VZ
AM6T-1215SH35-VZ
AM6T-1224SH35-VZ
AM6T-2405SH35-VZ
AM6T-2409SH35-VZ
AM6T-2412SH35-VZ
AM6T-2415SH35-VZ
AM6T-2424SH35-VZ
AM6T-4805SH35-VZ
AM6T-4809SH35-VZ
AM6T-4812SH35-VZ
AM6T-4815SH35-VZ
AM6T-4824SH35-VZ
Models
Dual output
Model
AM6T-1205D-VZ
AM6T-1209D-VZ
AM6T-1212D-VZ
AM6T-1215D-VZ
AM6T-1224D-VZ
AM6T-2405D-VZ
AM6T-2409D-VZ
AM6T-2412D-VZ
AM6T-2415D-VZ
AM6T-2424D-VZ
AM6T-4805D-VZ
AM6T-4809D-VZ
www.aimtec.com
F 051e R13.C
Wide 2:1 input range
24 Pin DIP Package
Metal package
High efficiency up to 81%
•
•
•
•
Operating temperature -40oC to + 85oC
Input / Output isolation 1500 & 3500 VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Capacitive load,
max (μF)
Efficiency
(%)
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Capacitive load,
max (μF)
Efficiency
(%)
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
±5
±9
1200
666
500
400
250
1200
666
500
400
250
1200
666
500
400
250
1200
666
500
400
250
1200
666
500
400
250
1200
666
500
400
250
±600
±333
±250
±200
±125
±600
±333
±250
±200
±125
±600
±333
Tel: +1 514 620 2722
1 of 4
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
±1000
±220
±220
±220
±100
±1000
±220
±220
±220
±100
±1000
±220
68
72
74
79
76
76
80
80
81
77
74
77
77
79
75
68
72
74
79
76
76
80
80
81
77
74
77
77
79
75
78
78
78
80
78
76
77
80
80
78
74
76
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6T-VZ
6 Watt | DC-DC Converter
Models
Dual output (continued)
Model
AM6T-4812D-VZ
AM6T-4815D-VZ
AM6T-4824D-VZ
Input Voltage
(V)
AM6T-1205DH35-VZ
AM6T-1209DH35-VZ
AM6T-1212DH35-VZ
AM6T-1215DH35-VZ
AM6T-1224DH35-VZ
AM6T-2405DH35-VZ
AM6T-2409DH35-VZ
AM6T-2412DH35-VZ
AM6T-2415DH35-VZ
AM6T-2424DH35-VZ
AM6T-4805DH35-VZ
AM6T-4809DH35-VZ
AM6T-4812DH35-VZ
AM6T-4815DH35-VZ
AM6T-4824DH35-VZ
Input Specifications
Parameters
Voltage Range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Isolation Specifications
Parameters
Tested I/O voltage
36-72
36-72
36-72
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
Output Voltage
(V)
±12
±15
±24
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
Parameters
Voltage accuracy
Voltage balance
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
www.aimtec.com
F 051e R13.C
±250
±200
±125
±600
±333
±250
±200
±125
±600
±333
±250
±200
±125
±600
±333
±250
±200
±125
Nominal
Typical
12 Vin
24 Vin
48 Vin
20
-0.7-24
-0.7-40
-0.7-80
15
12
24
48
Conditions
Balanced Load
HL-LL
25-100% Load
At 20MHz Bandwidth
±0.5
±0.5
±0.02
60
Units
VDC
Ms
Rated
1500 (3500 H35
model)
Maximum
Continuous
Auto Recovery
Tel: +1 514 620 2722
2 of 4
76
78
77
78
78
78
80
78
76
77
80
80
78
74
76
76
78
77
Ms
Typical
±1
±1
Efficiency
(%)
VDC
> 1000
60
Conditions
±220
±220
±100
±1000
±220
±220
±220
±100
±1000
±220
±220
±220
±100
±1000
±220
±220
±220
±100
π (Pi) Network
Typical
3 sec
Capacitive load,
max (μF)
Maximum
9-18
18-36
36-72
Resistance
Capacitance
Output Specifications
Output Current
max (mA)
Units
VDC
MOhm
pF
Units
%
%
%
%
%/oC
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6T-VZ
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
6 Watt | DC-DC Converter
Conditions
Typical
100-400
Full Load (see derating chart)
Maximum
-40 to +85
-40 to +125
Free air convection
100
Units
KHz
o
C
o
C
o
C
95
%
Nickel coated copper
15
G
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
1500 and 3500VDC
Single
Dual
2
3
9
11
14
16
22
23
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Dimensions
22.86
(0.90)
0.50
(0.02)
20.32
(0.80)
2
3
9
11
Bottom View
23 22
16
14
2.54
(0.10)
5.08
(0.20)
Built-in Stand-offs to
ease PCB cleaning
3.05
(0.12)
10.16
(0.40)
Printed Face
15.24
(0.60)
31.75
(1.25)
www.aimtec.com
F 051e R13.C
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6T-VZ
6 Watt | DC-DC Converter
Derating
Free Air Convection
85 º C
Output Power %
100
80
60
Safe Operating Area
40
20
0
-40
0
25
50
75
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.C
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages