Series AM8TW-Z 8Watt | DC-DC Converter FEATURES: • • • • Models Single output Model Input Voltage (V) AM8TW-2403SZ AM8TW-2405SZ AM8TW-2412SZ AM8TW-2415SZ AM8TW-4803SZ AM8TW-4805SZ AM8TW-4812SZ AM8TW-4815SZ 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 Models Dual output Model Input Voltage (V) AM8TW-2405DZ AM8TW-2412DZ AM8TW-2415DZ AM8TW-4805DZ AM8TW-4812DZ AM8TW-4815DZ 9-36 9-36 9-36 18-75 18-75 18-75 Wide 4:1 input range 24 Pin DIP Package High efficiency up to 87% Over Voltage/Overload Protection • • • • Operating temperature -40oC to + 85oC Input / Output Isolation 1600 VDC Continuous short circuit protection RoHS compliant Output Voltage (V) Output Current max (mA) Isolation (VDC) 3.3 5 12 15 3.3 5 12 15 2000 1500 665 535 2000 1500 665 535 1600 1600 1600 1600 1600 1600 1600 1600 Output Voltage (V) Output Current max (mA) Isolation (VDC) ±5 ±12 ±15 ±5 ±12 ±15 ±800 ±335 ±265 ±800 ±335 ±265 1600 1600 1600 1600 1600 1600 Max Capacitive Load(uF) Efficiency (%) 1330 1330 288 200 1330 1330 288 200 83 86 87 87 82 86 87 87 Max Capacitive Load(uF) Efficiency (%) ±900 ±133 ±90 ±900 ±133 ±90 84 86 87 84 87 87 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Peak Input Voltage time Nominal 24 48 24 48 On/Off control No Load Input Current Input reflected current Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R12.E Conditions 3 sec Typical 9-36 18-75 π (Pi) Network 20 Maximum Units VDC -0.7-50 -0.7-100 100 ON – 3.0 ~ 12VDC (or open) OFF -0~1.2VDC (or short between pin 1 and 2/3) 15 20 Typical >1000 1500 Tel: +1 514 620 2722 1 of 4 Rated 1600 ms VDC ms mA mAp-p Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Output Specifications Parameters Voltage accuracy Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Minimum Load Current General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation Conditions Typical Zener Diode Clamp 150 Continuous Auto-Recovery ±0.2 ±0.5 ±1 ±0.02 75 0 HL-LL 0 – 100% load 0 – 100% load 20MHz Bandwidth Conditions 100% load Derating above +70 Maximum ±1 Typical 270 -40 to +125 % % % % of Vin % % %/oC mV p-p % of Max Maximum Units KHz o C o C o C -40 to +85 Free air convection Units 105 95 Nickel plated Cooper 18 1.25 x 0.80 x 0.12 inches 31.80 x 20.30 x 10.20 mm > 1,000,100 hours(MIL-HDBK-217F , Ground Benign, t=+25oC) 1.5mm from case for 10sec 260 250 ±3 % RH g o C uS % Safety Specifications Parameters Agency Approval Standards www.aimtec.com F 051e R12.E CE EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Pin Out Specifications Pin 1 2 3 9 11 14 16 22 23 Single Remote On/Off -V Input -V Input No Pin N.C. +V Output -V Output +V Input +V Input N.C.: Not Connected Dimensions Dual Remote On/Off -V Input -V Input Common -V Output +V Output Common +V Input +V Input Derating 70 ºC Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Recommended Circuits Conducted Emissions +Vout L C1 +Vin DC/DC Converter C2 -Vin C1 2.2uF, 100V L 12uH Load -Vout C2 2.2uF, 100V Surge/EFT +Vin +Vout DC/DC Converter C1 Load -Vin -Vout C1 330uF, 100V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only