Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter FEATURES: • • • • I/O Isolation 4000VAC Operating Temp: -40oC to +70oC Over load, Over Voltage, Short Circuit Protection Up to 80% efficiency • • Energy Star compliant Ultra small package Models Single output Model AMEL10-3.3SMAZ AMEL10-5SMAZ AMEL10-12SMAZ AMEL10-15SMAZ AMEL10-24SMAZ CB Input Voltage (VAC/Hz) Input Voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 Max Output wattage (W) 9.9 10 10 10 10 Output Voltage (V) Output Current max (A) 3.3 5 12 15 24 3.00 2.00 0.84 0.67 0.42 (W) Output Voltage (V) Rated Output Current (A) Models Asymmetric Dual output Input Voltage (VAC/Hz) Input Voltage (VDC) AMEL10-3.35DMAZ AMEL10-3.312DMAZ AMEL10-3.315DMAZ AMEL10-3.324DMAZ AMEL10-512DMAZ AMEL10-515DMAZ AMEL10-524DMAZ AMEL10-1215DMAZ AMEL10-1224DMAZ AMEL10-1524DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 7.9 8 8 8 8 8 8 8 9 9 3.3/5 3.3/12 3.3/15 3.3/24 5/12 5/15 5/24 12/15 12/24 15/24 0.9/1.0 0.9/0.41 0.9/0.33 0.9/0.2 0.6/0.41 0.6/0.33 0.6/0.2 0.25/0.33 0.25/0.25 0.2/0.25 AMEL10-3.3N5DMAZ AMEL10-3.3N12DMAZ AMEL10-3.3N15DMAZ AMEL10-5N5DMAZ AMEL10-5N12DMAZ AMEL10-5N15DMAZ AMEL10-12N12DMAZ AMEL10-12N15DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 7.3 8 8 8 8 8 8 8 -3.3/5 -3.3/12 -3.3/15 -5/5 -5/12 -5/15 -12/12 -12/15 -0.7/1.0 -0.9/0.41 -0.9/0.33 -0.6/1 -0.6/0.41 -0.6/0.33 -0.25/0.41 -0.25/0.33 Model *Output power must not exceed the listed values. Max Output wattage Maximum capacitive load (µF) Efficiency (%) 2200 1000 680 470 470 75 77 79 80 80 Maximum capacitive load (µF) Efficiency (%) 680 680 680 680 470 470 470 330 330 330 74 77 76 75 75 77 75 76 78 79 680 680 680 680 470 470 470 330 74 75 75 74 74 74 76 75 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms (cold start) Leakage current External fuse www.aimtec.com F 052e R8.M Conditions Typical 115VAC 230VAC 115VAC 230VAC 0.23 0.15 slow blow type 1 Tel: +1 514 620 2722 1 of 4 Maximum 10 20 0.25 Units A A A A mA A Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ Input Specifications (continued) Parameters Input dissipation Start up time Conditions Typical Maximum Units Conditions Typical Maximum Units No Load Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Load regulation (dual output) Transient recovery time Transient response deviation 10 Watt | AC-DC / DC-DC Converter <0.5 50 ±2 ±1 ±2 ±3 500 ±2 75 100 10 25 0-100% load Unbalanced (0-100% load) 25% load step 3.3 & 5V models 12, 15 & 24V models 115VAC 230VAC Ripple & Noise* Hold-up time (min) W ms % % % % µs % of Vout mV p-p ms *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) & 4.7µF (E/C) parallel capacitor. Isolation Specifications Parameters Conditions Tested I/O voltage Isolation resistance Isolation capacitor General Specifications Parameters Switching frequency Over load protection Over voltage protection Short circuit protection Short circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Shock Vibration F 052e R8.M Units 4000 VAC MΩ pF Typical 100% load Auto recovery, Foldback Maximum 65 150 Zener Diode Clamp Continuous Auto recovery -40 to +70 See derating table Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Units KHz % o -45 to +95 ±0.02 Free air convection Non condensing 20 ~ 95 Plastic resin + Fiberglass (flammability to UL 94V-0) 70 2.22 x 1.21 x 0.99 inches 56.48 x 30.86 x 25.10mm > 400 000 hrs (MIL-HDBK -217F, t=+25oC) Converter operation www.aimtec.com Rated >1000 2200 Conditions Environment Approval Test Typical 3 sec, 1.2mA 100 C C o C % / oC o % RH g Conditions Half sine wave 5gn 30 ms before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine 1mm 3g 10-100Hz, speed 0.05Hz/s Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE, CB, TÜV Rheinhald (cTUVus), Bauart-Mark IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 Medical Electrical Equipment Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2) Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity IEC 61000-4-5 RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Information Technology Equipment UL 60950-1:2007 Information Technology Equipment CAN/CSA-C22.2 No.60950-1-07 Standards Pin Out Specifications Pin Single 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin Dual positive AC Input (N) AC Input (L) +V1 Output Common +V2 Output Dual negative/positive AC Input (N) AC Input (L) +V1 Output Common -V2 Output Dimensions 3 Top View 4 5,27 (0.21) 2 5 5.37 (0.21) 1 10.20 (0.40) 1 10.20 (0.40) 45.72 (1.80) 20.40 (0.80) 30.86 (1.21) 5.27 (0.21) 56.46 (2.22) 2 5.37 (0.21) 3 Top View 4 5 25.10 (0.99) DIV: 10.00 (0.40) 8.00 (0.31) 5Ø 1.0 (Ø 0.04) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002) Pin Pitch Tolerance ±0.35 (±0.014) 1.05 (0.04) www.aimtec.com F 052e R8.M Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Derating Free Air Convection 40°C Output Power (%) 100 80 60 Safe Operating Area 40 20 70°C 0 - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.M Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only