AIMTEC AMEL20-24SAZ 20 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
FEATURES:




I/O Isolation 3000VAC
Operating Temp: -40 oC to +80 oC
Over load and, Over Voltage Protection
Input: 90-305VAC, 47-440Hz, or 130-430VDC




CB
Models
Single output
Model
Energy Star compliant
Ultra small package
Up to 81% efficiency
Short Circuit Protection
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
wattage
(W)
Output
Current
max (A)
Output
Voltage(V)
Maximum
capacitive
load (µF)
Efficiency
(%)
115
230
277
VAC
VAC
VAC
AMEL20-3.3SAZ
90-305/47-440
130-430
13.2
3.3
4
5600
73
AMEL20-5SAZ
90-305/47-440
130-430
20
5
4
4700
77
AMEL20-12SAZ
90-305/47-440
130-430
20
12
1.66
3300
80
AMEL20-15SAZ
90-305/47-440
130-430
20
15
1.33
2200
81
AMEL20-24SAZ
90-305/47-440
130-430
20
24
0.84
1000
79
Note: Optional mounting plate version can be order by adding “-ST” suffix to part number (ex. AMEL20-5SMAZ-ST)
73
77
80
80
80
72
76
80
80
79
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC




1.5
≦0.5
150
Recommended slow blow type
(115/230/277 VAC)
Maximum
Units
460
290
260
30
50
55
0.25
mA
mA
mA
A
A
A
mA
A
W
ms
Maximum
Units
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time
Conditions
Typical
±2
±1
±2
500
±2
200
10
(LL-HL)
0-100% load
25% load step
%
%
%
µs
% of Vout
mV p-p
ms
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Typical
60 sec
Rated
Units
3000
VAC
MΩ
Maximum
Units
>1000
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
www.aimtec.com
F 052e R8.H
Conditions
Typical
Foldback
65
130
Zener Diode Clamp
Tel: +1 514 620 2722
1 of 5
KHz
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
Typical
Maximum
Auto recovery
Refer to Chart
With derating over 50ºC
Units
oC
oC
100
oC
-45 to +95
±0.02
% / oC
Free air convection
Non condensing
20 ~ 95
% RH
Plastic (flammability to UL 94V-0)
70
g
56.48 x 30.86 x 25.10mm (2.22 x 1.21 x 0.99 inches)
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage
(115/230/277VAC) and at rated output load unless otherwise specified.
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
CE, UL, FCC, CB
Information Technology Equipment
Information Technology Equipment
EMI - Conducted and radiated emission
Standards
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
FCC
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 5
UL 60950-1: 2nd Edition
CAN/CSA-C22.2 No.60950-1-07, 2nd Edition
EN55022, class B
EN55024: 2010
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, :2008
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006 + A1: 2007 + A2:2010
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2008
IEC 61000-4-8: 2009
IEC 61000-4-11: 2004
47 CFR Part 15 Subpart B, ICES-003 Iss. 5-2012,
ANSI C63.4-2009
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
Additional Surge Protective Circuitry
The AMEL20-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
Vrms
V
Vdc
V
Wmax (2ms)
J
Pmax
W
S14K320E2
320
420
136
0.6
Pin Out Specifications
Pin
Single
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
Derating
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
Dimensions
5.27
(0.21)
56.46
(2.22)
4
20.40
(0.80)
30.86
(1.21)
2
5,27
(0.21)
3
5
5.37
(0.21)
3
1
10.20
(0.40)
Top View
1
10.20
(0.40)
45.72
(1.80)
4
2
5.37
(0.21)
5
Temperature Measurement
point
25.10
(0.99)
DIV: 10.00 (0.40)
8.00
(0.31)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
1.05
(0.04)
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
Dimensions of Optional ST Mounting Plate Version
38.00
25.00
Pin Out Specification ST Version
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only