Advanced Monolithic Systems AMS2906 600mA LOW DROPOUT VOLTAGE REGULATOR FEATURES APPLICATIONS • Three Terminal Adjustable or Fixed Voltages* 1.5V, 2.5V, 2.85V, 3.3V and 5.0V • Output Current of 600mA • Operates Down to 1V Dropout • Line Regulation: 0.2% Max. • Load Regulation: 0.4% Max. • TO-252, SOT-223 and SOT-89 packages • High Efficiency Linear Regulators • Post Regulators for Switching Supplies • 5V to 3.3V Linear Regulator • Battery Chargers • Sound Cards • Power Management for Notebook • Battery Powered Instrumentation GENERAL DESCRIPTION The The AMS2906 series of adjustable and fixed voltage regulators are designed to provide 600mA output current and to operate down to 1V input-to-output differential. The dropout voltage of the device is guaranteed maximum 1.3V at maximum output current, decreasing at lower load currents. On-chip trimming adjusts the reference voltage to 1%. Current limit is also trimmed, minimizing the stress under overload conditions on both the regulator and power source circuitry. The AMS2906 devices are pin compatible with other three-terminal regulators and are offered in the low profile surface mount TO-252(DPAK), SOT-223 and SOT-89 packages. ORDERING INFORMATION: PACKAGE TYPE SOT-89 TO-252 OPERATING JUNCTION SOT-223 AMS2906CL AMS2906CD AMS2906 AMS2906CL-1.5 AMS2906CD-1.5 AMS2906-1.5 AMS2906CL-2.5 AMS2906CD-2.5 AMS2906-2.5 AMS2906CL-2.85 AMS2906CD-2.85 AMS2906-2.85 AMS2906CL-3.3 AMS2906CD-3.3 AMS2906-3.3 AMS2906CL-5.0 AMS2906CD-5.0 AMS2906-5.0 *For additional available fixed voltages contact factory. TEMPERATURE RANGE 0 to 125° C 0 to 125° C 0 to 125° C 0 to 125° C 0 to 125° C 0 to 125° C SOT-223 Top View SOT-89 Top View PIN CONNECTIONS 1 FIXED VERSION ADJUSTABLE VERSION 1- Ground 2- VOUT 3- VIN 1- Adjust 2- VOUT 3- VIN 2 3 1 2 3 TO-252 Front View Advanced Monolithic Systems, Inc. 3 2 1 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 ABSOLUTE MAXIMUM RATINGS (Note 1) Power Dissipation Internally limited Input Voltage 15V Operating Junction Temperature Range Control Section 0°C to 125°C Power Transistor 0°C to 150°C Storage temperature - 65°C to +150°C Soldering information Lead Temperature (10 sec) 300°C Thermal Resistance SOT-89 package TO-252 package SOT-223 package ϕ JA= 110°C/W ϕ JA= 80°C/W ϕ JA= 90°C/W* * With package soldering to copper area over backside ground plane or internal power plane ϕ JA can vary from 46°C/W to >90°C/W depending on mounting technique and the size of the copper area. ELECTRICAL CHARACTERISTICS Electrical Characteristics at IOUT = 0 mA, and TJ = +25°C unless otherwise specified. Parameter Device Conditions Min Reference Voltage (Note 2) AMS2906 IOUT = 10 mA 10mA ≤ IOUT ≤ 600mA, 1.5V≤ (VIN - VOUT) ≤ 12V 1.238 1.225 1.250 1.250 1.262 1.270 V V Output Voltage (Note 2) AMS2906-1.5 0 ≤ IOUT ≤ 600mA , 4.35V≤ VIN ≤ 12V 1.485 1.476 1.500 1.500 1.515 1.524 V V AMS2906-2.5 0 ≤ IOUT ≤ 600mA , 4.35V≤ VIN ≤ 12V 2.475 2.460 2.500 2.500 2.525 2.560 V V AMS2906-2.85 0 ≤ IOUT ≤ 600mA , 4.35V≤ VIN ≤ 12V 2.82 2.79 2.850 2.850 2.88 2.91 V V AMS2906-3.3 0 ≤ IOUT ≤ 600mA , 4.75V ≤ VIN ≤ 12V 3.267 3.235 3.300 3.300 3.333 3.365 V V AMS2906-5.0 0 ≤ IOUT ≤ 600mA , 6.5V ≤ VIN ≤ 12V 4.950 4.900 5.000 5.000 5.050 5.100 V V AMS2906 ILOAD = 10 mA , 1.5V≤ (VIN - VOUT) ≤ 12V 0.015 0.035 0.2 0.2 % % AMS2906-1.5 3.0V≤ VIN ≤ 12V 0.3 0.6 5 6 mV mV AMS2906-2.5 4.0V≤ VIN ≤ 12V 0.3 0.6 6 6 mV mV AMS2906-2.85 4.35V≤ VIN ≤ 12V 0.3 0.6 6 6 mV mV AMS2906-3.3 4.75V≤ VIN ≤ 12V 0.5 1.0 10 10 mV mV AMS2906-5.0 6.5V≤ VIN ≤ 12V 0.5 1.0 10 10 mV mV AMS2906 (VIN - VOUT) =3V, 10mA ≤ IOUT ≤ 600mA 0.1 0.2 0.3 0.4 % % AMS2906-1.5 VIN = 5V, 0 ≤ IOUT ≤ 600mA 3 6 10 20 mV mV AMS2906-2.5 VIN = 5V, 0 ≤ IOUT ≤ 600mA 3 6 12 20 mV mV AMS2906-2.85 VIN = 5V, 0 ≤ IOUT ≤ 600mA 3 6 12 20 mV mV AMS2906-3.3 VIN = 5V, 0 ≤ IOUT ≤ 600mA 3 7 15 25 mV mV AMS2906-5.0 VIN = 8V, 0 ≤ IOUT ≤ 600mA 5 10 20 35 mV mV Line Regulation Load Regulation (Notes 2, 3) Advanced Monolithic Systems, Inc. Typ Max Units 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 ELECTRICAL CHARACTERISTICS Electrical Characteristics at IOUT = 0 mA, and TJ = +25°C unless otherwise specified. Parameter Device Conditions Dropout Voltage (VIN - VOUT) AMS2906-1.5/-2.5/-2.85/ -3.3/-5.0 ∆VOUT , ∆VREF = 1%, IOUT = 600mA (Note 4) Current Limit AMS2906-1.5/-2.5/-2.85/ -3.3/-5.0 (VIN - VOUT) = 5V Minimum Load Current AMS2906 Quiescent Current Ripple Rejection Min Typ Max Units 1.1 1.3 V 1,000 1,200 mA (VIN - VOUT) = 12V (Note 5) 5 10 mA AMS2906-1.5/-2.5/-2.85/ -3.3/-5.0 VIN ≤ 12V 5 10 mA AMS2906 f =120Hz , COUT = 25µF Tantalum, IOUT = 600mA, (VIN-VOUT ) = 3V, CADJ =25µF 60 75 dB AMS2906-1.5 f =120Hz , COUT = 25µF Tantalum, IOUT = 600mA, VIN = 6V 60 72 dB AMS2906-2.5 f =120Hz , COUT = 25µF Tantalum, IOUT = 600mA, VIN = 6V 60 72 dB AMS2906-2.85 f =120Hz , COUT = 25µF Tantalum, IOUT = 600mA, VIN = 6V 60 72 dB AMS2906-3.3 f =120Hz , COUT = 25µF Tantalum, IOUT = 600mA VIN = 6.3V 60 72 dB AMS2906-5 f =120Hz , COUT = 25µF Tantalum, IOUT = 600mA VIN = 8V 60 68 dB Thermal Regulation AMS2906 TA = 25°C, 30ms pulse Adjust Pin Current AMS2906 10mA ≤ IOUT ≤ 600mA , 1.5V≤ (VIN - VOUT) ≤ 12V Adjust Pin Current Change AMS2906 10mA ≤ IOUT ≤ 600mA , 1.5V≤ (VIN - VOUT) ≤ 12V Temperature Stability 0.008 0.04 %W 120 µA µA 5 µA 55 0.2 % 0.5 Long Term Stability TA =125°C, 1000Hrs RMS Output Noise (% of VOUT ) TA = 25°C , 10Hz ≤ f ≤ 10kHz Thermal Resistance Junction-to-Case 800 0.3 1 0.003 % % 15 °C/W Parameters identified with boldface type apply over the full operating temperature range. Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Note 2: Line and Load regulation are guaranteed up to the maximum power dissipation of 1.2W for SOT-223 package and 0.9W for SOT-89 package. Power dissipation is determined by the input/output differential and the output current. Guaranteed maximum power dissipation will not be available over the full input/output range. Note 3: See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead ~1/8” from the package. Note 4: Dropout voltage is specified over the full output current range of the device. Note 5: Minimum load current is defined as the minimum output current required to maintain regulation. When 1.5V ≤ (VIN - VOUT) ≤ 12V the device is guaranteed to regulate if the output current is greater than 10mA. Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 APPLICATION HINTS The AMS2906 series of adjustable and fixed regulators are easy to use and are protected against short circuit and thermal overloads. Thermal protection circuitry will shut-down the regulator should the junction temperature exceed 165°C at the sense point. Pin compatible with older three terminal adjustable regulators, these devices offer the advantage of a lower dropout voltage, more precise reference tolerance and improved reference stability with temperature. D1 AMS2906 IN OUT ADJ VIN CADJ 10µF Stability The circuit design used in the AMS2906 series requires the use of an output capacitor as part of the device frequency compensation. The addition of 150µF aluminum electrolytic or a 22µF solid tantalum on the output will ensure stability for all operating conditions. When the adjustment terminal is bypassed with a capacitor to improve the ripple rejection, the requirement for an output capacitor increases. The value of 22µF tantalum or 150µF aluminum covers all cases of bypassing the adjustment terminal. Without bypassing the adjustment terminal smaller capacitors can be used with equally good results. To ensure good transient response with heavy load current changes capacitor values on the order of 100µF are used in the output of many regulators. To further improve stability and transient response of these devices larger values of output capacitor can be used. R1 COUT 150µF R2 Figure 1. Output Voltage The AMS2906 series develops a 1.25V reference voltage between the output and the adjust terminal. Placing a resistor between these two terminals causes a constant current to flow through R1 and down through R2 to set the overall output voltage. This current is normally the specified minimum load current of 10mA. Because IADJ is very small and constant it represents a small error and it can usually be ignored. AMS2906 IN OUT ADJ VIN Protection Diodes VOUT VREF R1 IADJ Unlike older regulators, the AMS2906 family does not need any protection diodes between the adjustment pin and the output and from the output to the input to prevent over-stressing the die. Internal resistors are limiting the internal current paths on the AMS2906 adjustment pin, therefore even with capacitors on the adjustment pin no protection diode is needed to ensure device safety under short-circuit conditions. Diodes between the input and output are not usually needed. Microsecond surge currents of 50A to 100A can be handled by the internal diode between the input and output pins of the device. In normal operations it is difficult to get those values of surge currents even with the use of large output capacitances. If high value output capacitors are used, such as 1000µF to 5000µF and the input pin is instantaneously shorted to ground, damage can occur. A diode from output to input is recommended, when a crowbar circuit at the input of the AMS2906 is used (Figure 1). 50µA R2 VOUT = VREF (1+ R2/R1)+IADJR2 Figure 2. Basic Adjustable Regulator Load Regulation True remote load sensing it is not possible to provide, because the AMS2906 is a three terminal device. The resistance of the wire connecting the regulator to the load will limit the load regulation. The data sheet specification for load regulation is measured at the bottom of the package. Negative side sensing is a true Kelvin connection, with the bottom of the output divider returned to the negative side of the load. The best load regulation is obtained when the top of the resistor divider R1 is connected directly to the case not to the load. If R1 were connected to the load, the effective resistance between the regulator and the load would be: RP x ( R2+R1 ) , R1 Advanced Monolithic Systems, Inc. VOUT + RP = Parasitic Line Resistance 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 APPLICATION HINTS Connected as shown , RP is not multiplied by the divider ratio VIN AMS2906 IN OUT ADJ RP PARASITIC LINE RESISTANCE RL R1* R2* *CONNECT R1 TO CASE The total thermal resistance from junction to ambient can be as low as 45°C/W. This requires a reasonable sized PC board with at least on layer of copper to spread the heat across the board and couple it into the surrounding air. Experiments have shown that the heat spreading copper layer does not need to be electrically connected to the tab of the device. The PC material can be very effective at transmitting heat between the pad area, attached to the pad of the device, and a ground plane layer either inside or on the opposite side of the board. Although the actual thermal resistance of the PC material is high, the Length/Area ratio of the thermal resistance between layers is small. The data in Table 1, was taken using 1/16” FR-4 board with 1 oz. copper foil, and it can be used as a rough guideline for estimating thermal resistance. For each application the thermal resistance will be affected by thermal interactions with other components on the board. To determine the actual value some experimentation will be necessary. The power dissipation of the AMS2906 is equal to: PD = ( VIN - VOUT )( IOUT ) CONNECT R2 TO LOAD Maximum junction temperature will be equal to: Figure 3. Connections for Best Load Regulation TJ = TA(MAX) + PD(Thermal Resistance (junction-to-ambient)) In the case of fixed voltage devices the top of R1 is connected Kelvin internally, and the ground pin can be used for negative side sensing. Maximum junction temperature must not exceed 125°C. Ripple Rejection Thermal Considerations The AMS2906 series have internal power and thermal limiting circuitry designed to protect the device under overload conditions. However maximum junction temperature ratings of 125°C should not be exceeded under continuous normal load conditions. Careful consideration must be given to all sources of thermal resistance from junction to ambient. For the surface mount package SOT-223 additional heat sources mounted near the device must be considered. The heat dissipation capability of the PC board and its copper traces is used as a heat sink for the device. The thermal resistance from the junction to the tab for the AMS2906 is 15°C/W. Thermal resistance from tab to ambient can be as low as 30°C/W. The ripple rejection values are measured with the adjustment pin bypassed. The impedance of the adjust pin capacitor at the ripple frequency should be less than the value of R1 (normally 100Ω to 200Ω) for a proper bypassing and ripple rejection approaching the values shown. The size of the required adjust pin capacitor is a function of the input ripple frequency. If R1=100Ω at 120Hz the adjust pin capacitor should be >13µF. At 10kHz only 0.16µF is needed. The ripple rejection will be a function of output voltage, in circuits without an adjust pin bypass capacitor. The output ripple will increase directly as a ratio of the output voltage to the reference voltage (VOUT / VREF). Table 1. COPPER AREA TOP SIDE* BACK SIDE BOARD AREA 2500 Sq. mm 2500 Sq. mm 2500 Sq. mm 1000 Sq. mm 2500 Sq. mm 2500 Sq. mm 225 Sq. mm 2500 Sq. mm 2500 Sq. mm 100 Sq. mm 2500 Sq. mm 2500 Sq. mm 1000 Sq. mm 1000 Sq. mm 1000 Sq. mm 1000 Sq. mm 0 1000 Sq. mm * Tab of device attached to topside copper. Advanced Monolithic Systems, Inc. THERMAL RESISTANCE (JUNCTION-TO-AMBIENT) 45°C/W 45°C/W 53°C/W 59°C/W 52°C/W 55°C/W 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 TYPICAL PERFORMANCE CHARACTERISTICS Minimum Operating Current (Adjustable Device) Short-Circuit Current 1.25 TJ = 125°C 9 SHORT CIRCUIT CURRENT (A) MINIMUM OPERATING CURRENT (mA) 12 TJ = 125°C TJ = 25°C 6 3 0 1.00 TJ = 25°C 0.75 0.50 0.25 0 0 5 10 15 20 0 5 Load Regulation 15 Ripple Rejection vs. Current 100 0.10 ∆ ILOAD = 600mA 90 fRIPPLE = 120Hz 0.05 80 RIPPLE REJECTION (dB) OUTPUT VOLTAGE DEVIATION (%) 10 INPUT/OUTPUT DIFFERENTIAL INPUT/OUTPUT DIFFERENTIAL (V) 0 -0.05 -0.10 VRIPPLE≤3Vp-p 70 60 fRIPPLE = 20Hz 50 40 VRIPPLE≤0.5Vp-p 30 20 -0.15 VOUT = 5V CADJ = 25µF COUT = 25µF 10 -0.20 0 -50 -25 0 25 50 75 100 125 0 0.15 0.3 0.45 0.6 OUTPUT CURRENT (A) TEMPERATURE (°C) Temperature Stability Adjust Pin Current 2.0 100 80 1.0 ADJUST PIN CURRENT (µA) OUTPUT VOLTAGE CHANGE (%) 90 0 -1.0 70 60 50 40 30 20 10 -2.0 0 -50 -25 0 25 50 75 TEMPERATURE (°C) Advanced Monolithic Systems, Inc. 100 125 150 -50 -25 0 25 50 75 100 125 150 TEMPERATURE (°C) 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 PACKAGE DIMENSIONS inches (millimeters) unless otherwise noted. TO-252 PLASTIC PACKAGE (D) 0.020-0.030 (0.508-0.762) 0.258-0.262 (6.553-6.654) 0.208-0.212 (5.283-5.384) 0.020-0.030 (0.508-0.762) 0.085-0.095 (2.159-2.413) 0.033-0.037 (0.838-0.939) 0.030-0.034 (0.762-0.863) 0.038-0.042 (0.965-1.066) 7.0° 0.023-0.027 (0.584-0.685) 45.0° 0.175-0.180 (4.191-4.445) 0.235-0.245 (5.969-6.223) 0.057-0.067 (0.144-0.170) DIA 0.025 (0.635) TYP 0.038 (0.965) TYP 0.099-0.103 (2.514-2.615) 0.088-0.092 (2.235-2.336) 0.030 (0.762) TYP 0.038-0.042 (0.965-1.066) 0.024±0.002 (0.610±0.0508) 0.018-0.022 (0.451-0.558) D (D3) AMS DRW# 042891 3 LEAD SOT-223 PLASTIC PACKAGE 0.248-0.264 (6.30-6.71) 0.116-0.124 (2.95-3.15) 0.264-0.287 (6.71-7.29) 0.130-0.146 (3.30-3.71) 0.033-0.041 (0.84-1.04) 0.090 (2.29) NOM 10°-16° 10° MAX 0.071 (1.80) MAX 0.010-0.014 (0.25-0.36) 10°-16° 0.025-0.033 (0.64-0.84) 0.181 (4.60) NOM Advanced Monolithic Systems, Inc. 0.012 (0.31) MIN 0.025-0.033 (0.64-0.84) (SOT-223 ) AMS DRW# 042292 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140 AMS2906 PACKAGE DIMENSIONS inches (millimeters) unless otherwise noted (Continued). SOT-89 PLASTIC PACKAGE (L) 0.173-0.181 (4.40-4.60) 0.055-0.063 (1.40-1.60) 0.014-0.017 (0.35-0.44) 0.064-0.072 (1.62-1.83) 0.155-0.167 (3.94-4.25) 0.084-0.090 (2.13-2.29) 0.090-0.102 (2.29-2.60) 0.035-0.047 (0.89-1.20) 0.059 (1.50) BSC 0.014-0.019 (0.36-0.48) 0.017-0.022 (0.44-0.56) L (SOT-89 ) AMS DRW# 042392 0.118 (3.00) BSC Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140