AOSMD AOZ8105CI Plastic encapsulated device Datasheet

AOS Semiconductor
Product Reliability Report
AOZ8105CI, rev B
Plastic Encapsulated Device
ALPHA & OMEGA Semiconductor, Inc
www.aosmd.com
1
This AOS product reliability report summarizes the qualification result for AOZ8105CI.
Reviewing of the electrical test results confirm that AOZ8105CI pass AOS quality and reliability
requirements. The continuous qualification testing and reliability monitoring program ensure that all outgoing
products will continue to meet AOS quality and reliability standards.
Table of Contents:
I.
II.
III.
IV.
Product Description
Package and Die information
Qualification Tests Result
Reliability Evaluation
I. Product Description:
The AOZ8105CI is a transient voltage suppressor array designed to protect high speed data lines such as HDMI
and Gigabit Ethernet from damaging ESD events.
-ROHS compliant
-Halogen free
.
Details please refer to the datasheet.
II. Package and Die Information:
Product ID
Process
Package Type
Lead Frame
Die attach material
Die bond wire
MSL level
AOZ8105CI
HV031A1
SOT23
Cu
84-1MISR4
Cu, 1 mil
Up to Level 1
2
III. Qualification Tests Result:
Test Item
Test Condition
Test
Duration
Sample Size
Pre-Conditioning
168hrs @85 °C
/85%RH+3 cyc
reflow@260°C
-
JESD22-A113
22 lots (Sum of
TC,PCT and HAST)
HTRB
Vdd= 80% Vbr max.
Temp = 150°C
168hrs
500hrs
7 lots
2 lots
Temperature
Cycle
'-65 °C to +150 °C,
air to air
500cycles
77pcs/lot
19 lots
Standard
JESD22-A108
JESD22-A110
77pcs/lot
Pressure Pot
121°C, 29.7psi,
RH= 100%
96hrs
22 lots
JESD22-A102
77pcs/lot
HAST
'130 +/- 2°C, 85%RH,
33.3 psi, at VCC min
power dissipation.
100hrs
20 lots
JESD22-A104
55pcs/lot
IV. Reliability Evaluation
FIT rate (per billion): 21
MTTF = 5393 years
The presentation of FIT rate for the individual product reliability is restricted by the actual HTRB sample size
of the selected product. Failure Rate Determination is based on JEDEC Standard JESD 85. FIT means one
failure per billion device hours.
Failure Rate = Chi2 x 109 / [2 (N) (H) (Af)] = 1.83 x 109 / [2x (7x77x168+2x77x500) x258] = 21
MTTF = 109 / FIT = 4.72 x107hrs= 5393 years
Chi² = Chi Squared Distribution, determined by the number of failures and confidence interval
N = Total Number of units from HTRB tests
H = Duration of HTRB testing
Af = Acceleration Factor from Test to Use Conditions (Ea = 0.7eV and Tuse = 55°C)
Acceleration Factor [Af] = Exp [Ea / k (1/Tj u – 1/Tj s)]
Acceleration Factor ratio list:
55 deg C 70 deg C 85 deg C 100 deg
115 deg
130 deg
150 deg C
C
C
C
Af
258
87
32
13
5.64
2.59
1
Tj s = Stressed junction temperature in degree (Kelvin), K = C+273.16
Tj u =The use junction temperature in degree (Kelvin), K = C+273.16
k = Boltzmann’s constant, 8.617164 X 10-5eV / K