ETC AP-30712B3-302

AP-30711/12
SYNCHRO/RESOLVER ANGLE POSITION INDICATOR
FEATURES
DESCRIPTION
The AP-30711 and the AP-30712 are
both high resolution, dual input, synchro/resolver angle position indicators. These units convert analog synchro or resolver position information
into a digital word. The digital word is
used to display angular information
on the front panel of the unit. Each
unit’s standard display angular range
is decimal degrees from 0.000° to
359.999°. Bipolar ±179.995° is available as a low-cost option. Both units
are available in two frequency ranges
of 360 to 1200 Hz or 47 to 440 Hz.
The digital word is also available for
use from the rear panel of both units
through a parallel BCD interface.
The AP-30711’s small size and
remote programming feature makes it
© 1999 Data Device Corporation
ideal for automatic test, panel mount
applications. The bench top AP30712 has input terminals and controls on the front panel, and is available with an optional IEEE-488 or
MATE/CIIL interface in the rear.
• Transformer-Isolated
APPLICATIONS
• Resolution: 0.001°
The AP-30711 and the AP-30712 can
be used wherever high accuracy synchro or resolver angle information is
required for display, control, testing purposes or computation. Applications
include development or production
testing of synchro/resolver based systems, information translators in quality control systems, machine tool controls, motion feedback, and automatic
test equipment.
• Auto Phase Shift
Synchro and Resolver
Inputs
• Auto-Leveling of Any Input
Between 10 and 100 V L-L
Compensation
• IEEE-488 or MATE/CIIL
Interface Option
AP-30711 AND AP-30712 SPECIFICATIONS
PARAMETER
UNIT
Resolution
Standard
±179.995 Option
degrees
degrees
Digital Inputs
(TTL Compatible) Level
Logic “1”
Logic “0”
Loading
Data Freeze
DF
degrees
degrees
±0.004
±0.010
Angular Ranges
Standard
±179.995 Option
degrees
degrees
0° - 359.999°
±179.995°
Display
Number of digits
Size of digits
digits
inches
Reference Input
Voltage
Frequency
V rms
Hz
Impedance
Ohms
Voltage Levels
Frequency
Allowable Phase Shift
Impedance
Dynamic Characteristics
Tracking Rate
47-440 Hz unit
360-1200 Hz unit
Settling Time
(for 180° step)
47-440 Hz unit
360-1200 Hz unit
PARAMETER
0.001
0.005
Accuracy
Standard
±179.995 Option
Signal Input
Input Type
AP-30711
AP-30712
AP-30711 AND AP-30712 SPECIFICATIONS (con’t)
VALUE
Standard
6 decimal
0.55
DF
Channel Select
±179 Option
5½ decimal
0.55
V L-L
Hz
Hz
degrees
Ohms
deg/sec
deg/sec
0°-359.999°
75
200
±179.995°
180
1000
sec max
sec max
3.0
1.5
1.5
0.4
V
V
(pin 42)
(pin 27)
(pin 43)
Digital Outputs
Digital Output Data
Drive Capability
3 to 115
47 to 400, or
360 to 1200
100k minimum
synchro or resolver
Channel 1: synchro
Channel 2: resolver
10 to 100 (AGC)
47 to 440, or
360 to 1200
±30 maximum
1 Meg minimum
UNIT
Logic “1”
Logic “0”
Converter Busy
Power Input
Voltage
Frequency
Power
Temperature Range
Operating
Physical
Characteristics
Size
AP-30711
AP-30712
Weight
AP-30711
AP-30712
2
VALUE
2.4 minimum
0.8 maximum
1 standard TTL
“1” Freeze, “0” or
Open-Track
“0” Freeze, “1” or
Open - Track
“0” CHAN 1
“1” or open - CHAN 2
V
V
6 decade BCD (1; 2; 4; 8 code)
10 TTL loads
IEEE-488 GPIB (optional)
+2.5 minimum
+0.6 maximum
TTL compatible pulses,
1 µs wide; transfer data
2 µs after trailing edge of pulse
V rms
V rms
Hz
VA
115 ±10%, or
230 ±10%
47 - 440
25 maximum
°C
0 - 70
inches
(cm)
inches
(cm)
1.75 x 9.50 x 12.50
(4.45 x 24.13 x 31.75)
3.50 x 9.50 x 12.50
(8.89 x 24.13 x 31.75)
lbs (kg)
lbs (kg)
6 (2.72)
8 (3.63)
ORDERING INFORMATION
AP-30711PX-301 X
Operating Voltage:
V = factory set for 230VAC line cord operation
Blank = factory set for 115VAC line cord operation
Frequency and Display Ranges:
1 = 360-1200 Hz, 0.000 Deg.
-359.999 Deg.
2 = 47-440 Hz, 0.000 Deg.
-359.999 Deg.
3 = 360-1200 Hz, ±179.995 Deg.
4 = 47-440 Hz, ±179.995 Deg.
AP-30712BX-30X X
Operating Voltage:
V = factory set for 230VAC line cord operation
Blank = factory set for 115VAC line cord operation
Interface:
1 = Parallel BCD
2 = IEEE 488 With Parallel BCD
3 = MATE/CIIL With Parallel BCD
Frequency And Display Range:
1 = 360-1200 Hz, 0.000 Deg.
-359.999 Deg.
2 = 47-440Hz, 0.000 Deg.
-359.999 Deg.
3 = 360-1200 Hz, ±179.995 Deg.
4 = 47-440Hz, ±179.995 Deg.
1.25
1.72
FRONT VIEW
8.81
9.50
7.94
.25 WIDE x .44
LONG OVAL
4 THRU HOLES
REAR VIEW
12.00
.125
.50
SIDE VIEW
2.98
3.50
FRONT VIEW
8.875
9.50
7.94
.25 WIDE x .44
LONG OVAL
4 THRU HOLES
ADDRESS
REAR VIEW
1.156
12.00
SIDE VIEW
AP-30711/12 MECHANICAL OUTLINE
3
.50
The information provided in this data sheet is believed to be accurate; however, no responsibility
is assumed by Data Device Corporation for its use, and no license or rights
are granted by implication or otherwise in connection therewith.
Specifications are subject to change without notice.
105 Wilbur Place, Bohemia, New York 11716-2482
For Technical Support - 1-800-DDC-5757 ext. 7389 or 7413
Headquarters - Tel: (631) 567-5600 ext. 7389 or 7413, Fax: (631) 567-7358
Southeast - Tel: (703) 450-7900, Fax: (703) 450-6610
West Coast - Tel: (714) 895-9777, Fax: (714) 895-4988
Europe - Tel: +44-(0)1635-811140, Fax: +44-(0)1635-32264
Asia/Pacific - Tel: +81-(0)3-3814-7688, Fax: +81-(0)3-3814-7689
World Wide Web - http://www.ddc-web.com
B-09/99-500
4
PRINTED IN THE U.S.A.