AP-30711/12 SYNCHRO/RESOLVER ANGLE POSITION INDICATOR FEATURES DESCRIPTION The AP-30711 and the AP-30712 are both high resolution, dual input, synchro/resolver angle position indicators. These units convert analog synchro or resolver position information into a digital word. The digital word is used to display angular information on the front panel of the unit. Each unit’s standard display angular range is decimal degrees from 0.000° to 359.999°. Bipolar ±179.995° is available as a low-cost option. Both units are available in two frequency ranges of 360 to 1200 Hz or 47 to 440 Hz. The digital word is also available for use from the rear panel of both units through a parallel BCD interface. The AP-30711’s small size and remote programming feature makes it © 1999 Data Device Corporation ideal for automatic test, panel mount applications. The bench top AP30712 has input terminals and controls on the front panel, and is available with an optional IEEE-488 or MATE/CIIL interface in the rear. • Transformer-Isolated APPLICATIONS • Resolution: 0.001° The AP-30711 and the AP-30712 can be used wherever high accuracy synchro or resolver angle information is required for display, control, testing purposes or computation. Applications include development or production testing of synchro/resolver based systems, information translators in quality control systems, machine tool controls, motion feedback, and automatic test equipment. • Auto Phase Shift Synchro and Resolver Inputs • Auto-Leveling of Any Input Between 10 and 100 V L-L Compensation • IEEE-488 or MATE/CIIL Interface Option AP-30711 AND AP-30712 SPECIFICATIONS PARAMETER UNIT Resolution Standard ±179.995 Option degrees degrees Digital Inputs (TTL Compatible) Level Logic “1” Logic “0” Loading Data Freeze DF degrees degrees ±0.004 ±0.010 Angular Ranges Standard ±179.995 Option degrees degrees 0° - 359.999° ±179.995° Display Number of digits Size of digits digits inches Reference Input Voltage Frequency V rms Hz Impedance Ohms Voltage Levels Frequency Allowable Phase Shift Impedance Dynamic Characteristics Tracking Rate 47-440 Hz unit 360-1200 Hz unit Settling Time (for 180° step) 47-440 Hz unit 360-1200 Hz unit PARAMETER 0.001 0.005 Accuracy Standard ±179.995 Option Signal Input Input Type AP-30711 AP-30712 AP-30711 AND AP-30712 SPECIFICATIONS (con’t) VALUE Standard 6 decimal 0.55 DF Channel Select ±179 Option 5½ decimal 0.55 V L-L Hz Hz degrees Ohms deg/sec deg/sec 0°-359.999° 75 200 ±179.995° 180 1000 sec max sec max 3.0 1.5 1.5 0.4 V V (pin 42) (pin 27) (pin 43) Digital Outputs Digital Output Data Drive Capability 3 to 115 47 to 400, or 360 to 1200 100k minimum synchro or resolver Channel 1: synchro Channel 2: resolver 10 to 100 (AGC) 47 to 440, or 360 to 1200 ±30 maximum 1 Meg minimum UNIT Logic “1” Logic “0” Converter Busy Power Input Voltage Frequency Power Temperature Range Operating Physical Characteristics Size AP-30711 AP-30712 Weight AP-30711 AP-30712 2 VALUE 2.4 minimum 0.8 maximum 1 standard TTL “1” Freeze, “0” or Open-Track “0” Freeze, “1” or Open - Track “0” CHAN 1 “1” or open - CHAN 2 V V 6 decade BCD (1; 2; 4; 8 code) 10 TTL loads IEEE-488 GPIB (optional) +2.5 minimum +0.6 maximum TTL compatible pulses, 1 µs wide; transfer data 2 µs after trailing edge of pulse V rms V rms Hz VA 115 ±10%, or 230 ±10% 47 - 440 25 maximum °C 0 - 70 inches (cm) inches (cm) 1.75 x 9.50 x 12.50 (4.45 x 24.13 x 31.75) 3.50 x 9.50 x 12.50 (8.89 x 24.13 x 31.75) lbs (kg) lbs (kg) 6 (2.72) 8 (3.63) ORDERING INFORMATION AP-30711PX-301 X Operating Voltage: V = factory set for 230VAC line cord operation Blank = factory set for 115VAC line cord operation Frequency and Display Ranges: 1 = 360-1200 Hz, 0.000 Deg. -359.999 Deg. 2 = 47-440 Hz, 0.000 Deg. -359.999 Deg. 3 = 360-1200 Hz, ±179.995 Deg. 4 = 47-440 Hz, ±179.995 Deg. AP-30712BX-30X X Operating Voltage: V = factory set for 230VAC line cord operation Blank = factory set for 115VAC line cord operation Interface: 1 = Parallel BCD 2 = IEEE 488 With Parallel BCD 3 = MATE/CIIL With Parallel BCD Frequency And Display Range: 1 = 360-1200 Hz, 0.000 Deg. -359.999 Deg. 2 = 47-440Hz, 0.000 Deg. -359.999 Deg. 3 = 360-1200 Hz, ±179.995 Deg. 4 = 47-440Hz, ±179.995 Deg. 1.25 1.72 FRONT VIEW 8.81 9.50 7.94 .25 WIDE x .44 LONG OVAL 4 THRU HOLES REAR VIEW 12.00 .125 .50 SIDE VIEW 2.98 3.50 FRONT VIEW 8.875 9.50 7.94 .25 WIDE x .44 LONG OVAL 4 THRU HOLES ADDRESS REAR VIEW 1.156 12.00 SIDE VIEW AP-30711/12 MECHANICAL OUTLINE 3 .50 The information provided in this data sheet is believed to be accurate; however, no responsibility is assumed by Data Device Corporation for its use, and no license or rights are granted by implication or otherwise in connection therewith. Specifications are subject to change without notice. 105 Wilbur Place, Bohemia, New York 11716-2482 For Technical Support - 1-800-DDC-5757 ext. 7389 or 7413 Headquarters - Tel: (631) 567-5600 ext. 7389 or 7413, Fax: (631) 567-7358 Southeast - Tel: (703) 450-7900, Fax: (703) 450-6610 West Coast - Tel: (714) 895-9777, Fax: (714) 895-4988 Europe - Tel: +44-(0)1635-811140, Fax: +44-(0)1635-32264 Asia/Pacific - Tel: +81-(0)3-3814-7688, Fax: +81-(0)3-3814-7689 World Wide Web - http://www.ddc-web.com B-09/99-500 4 PRINTED IN THE U.S.A.