APT50M50JVR 77A 0.050Ω 500V POWER MOS V ® S S Power MOS V® is a new generation of high voltage N-Channel enhancement mode power MOSFETs. This new technology minimizes the JFET effect, increases packing density and reduces the on-resistance. Power MOS V® also achieves faster switching speeds through optimized gate layout. 27 2 T- D G SO "UL Recognized" ISOTOP ® • Faster Switching • 100% Avalanche Tested • Lower Leakage • Popular SOT-227 Package D G S MAXIMUM RATINGS Symbol VDSS ID All Ratings: TC = 25°C unless otherwise specified. Parameter APT50M50JVR UNIT 500 Volts Drain-Source Voltage 77 Continuous Drain Current @ TC = 25°C 1 Amps IDM Pulsed Drain Current VGS Gate-Source Voltage Continuous ±30 Gate-Source Voltage Transient ±40 Total Power Dissipation @ TC = 25°C 700 Watts Linear Derating Factor 5.6 W/°C VGSM PD TJ,TSTG 308 -55 to 150 Operating and Storage Junction Temperature Range TL Lead Temperature: 0.063" from Case for 10 Sec. IAR Avalanche Current 1 77 1 Repetitive Avalanche Energy EAS Single Pulse Avalanche Energy °C 300 (Repetitive and Non-Repetitive) EAR Volts Amps 50 4 mJ 3600 STATIC ELECTRICAL CHARACTERISTICS BVDSS ID(on) RDS(on) IDSS IGSS VGS(th) Characteristic / Test Conditions MIN Drain-Source Breakdown Voltage (VGS = 0V, I D = 250µA) 500 Volts 77 Amps On State Drain Current 2 (VDS > I D(on) x R DS(on) Max, VGS = 10V) Drain-Source On-State Resistance 2 TYP (VGS = 10V, 0.5 ID[Cont.]) MAX 0.050 Zero Gate Voltage Drain Current (VDS = VDSS, VGS = 0V) 100 Zero Gate Voltage Drain Current (VDS = 0.8 VDSS, VGS = 0V, TC = 125°C) 500 Gate-Source Leakage Current (VGS = ±30V, VDS = 0V) Gate Threshold Voltage (VDS = VGS, ID = 5mA) UNIT Ohms µA ±100 nA 4 Volts 2 CAUTION: These Devices are Sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed. USA APT Website - http://www.advancedpower.com 405 S.W. Columbia Street Bend, Oregon 97702-1035 Phone: (541) 382-8028 FAX: (541) 388-0364 F-33700 Merignac - France Phone: (33) 5 57 92 15 15 FAX: (33) 5 56 47 97 61 EUROPE Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord 050-5534 Rev C Symbol APT50M50JVR DYNAMIC CHARACTERISTICS Symbol Characteristic Test Conditions MIN TYP MAX Ciss Input Capacitance VGS = 0V 16300 19600 Coss Output Capacitance VDS = 25V 2210 3090 Reverse Transfer Capacitance f = 1 MHz 850 1275 Crss Qg Total Gate Charge Qgs 3 VGS = 10V 675 1000 VDD = 0.5 VDSS 95 140 ID = ID[Cont.] @ 25°C 320 480 Gate-Source Charge Qgd Gate-Drain ("Miller ") Charge td(on) Turn-on Delay Time tr VGS = 15V 25 50 VDD = 0.5 VDSS 20 40 ID = ID[Cont.] @ 25°C 85 125 RG = 0.6Ω 12 24 TYP MAX Rise Time td(off) Turn-off Delay Time tf Fall Time UNIT pF nC ns SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS Symbol IS ISM VSD Characteristic / Test Conditions MIN 77 Continuous Source Current (Body Diode) Pulsed Source Current 1 (Body Diode) 308 Diode Forward Voltage 2 (VGS = 0V, IS = -ID[Cont.]) 1.3 t rr Reverse Recovery Time (IS = -ID[Cont.], dl S/dt = 100A/µs) Q rr Reverse Recovery Charge (IS = -ID[Cont.], dl S/dt = 100A/µs) UNIT Amps Volts 880 ns 31 µC THERMAL / PACKAGE CHARACTERISTICS Symbol Characteristic MIN RθJC Junction to Case RθJA Junction to Ambient VIsolation RMS Voltage (50-60 Hz Sinusoidal Waveform From Terminals to Mounting Base for 1 Min.) Torque Maximum Torque for Device Mounting Screws and Electrical Terminations. 1 Repetitive Rating: Pulse width limited by maximum junction temperature. 2 Pulse Test: Pulse width < 380 µS, Duty Cycle < 2% TYP MAX UNIT 0.18 40 °C/W 2500 Volts 13 3 See MIL-STD-750 Method 3471 4 Starting T = +25°C, L = 1.21mH, R = 25Ω, Peak I = 77A j G L APT Reserves the right to change, without notice, the specifications and information contained herein. 0.1 D=0.5 0.05 0.2 0.1 0.01 0.005 0.05 Note: 0.02 PDM Z JC, THERMAL IMPEDANCE (°C/W) θ 050-5534 Rev C 0.2 0.01 SINGLE PULSE t2 Duty Factor D = t1/t2 Peak TJ = PDM x ZθJC + TC 0.001 0.0005 10-5 t1 10-4 10-3 10-2 10-1 1.0 10 RECTANGULAR PULSE DURATION (SECONDS) FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION lb•in APT50M50JVR 250 250 VGS=15V ID, DRAIN CURRENT (AMPERES) 6.5V 200 150 6V 100 5.5V 50 5V 4.5V 0 50 100 150 200 250 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 2, TYPICAL OUTPUT CHARACTERISTICS TJ = +125°C 200 VDS> ID (ON) x RDS (ON)MAX. 250µSEC. PULSE TEST @ <0.5 % DUTY CYCLE 150 100 TJ = +125°C 50 TJ = +25°C TJ = -55°C 0 0 2 4 6 8 VGS, GATE-TO-SOURCE VOLTAGE (VOLTS) FIGURE 4, TYPICAL TRANSFER CHARACTERISTICS BVDSS, DRAIN-TO-SOURCE BREAKDOWN VOLTAGE (NORMALIZED) ID, DRAIN CURRENT (AMPERES) 80 60 40 20 0 50 75 100 125 150 TC, CASE TEMPERATURE (°C) FIGURE 6, MAXIMUM DRAIN CURRENT vs CASE TEMPERATURE 25 6V 100 5.5V 50 5V 1.3 V GS NORMALIZED TO = 10V @ 0.5 I [Cont.] D 1.2 1.1 VGS=10V VGS=20V 1.0 0.9 0 50 100 150 200 250 ID, DRAIN CURRENT (AMPERES) FIGURE 5, RDS(ON) vs DRAIN CURRENT 1.15 1.10 1.05 1.00 0.95 0.90 -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) FIGURE 7, BREAKDOWN VOLTAGE vs TEMPERATURE -50 1.2 2.5 I = 0.5 I [Cont.] D D V GS = 10V 2.0 1.5 1.0 0.5 0.0 -50 -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) FIGURE 8, ON-RESISTANCE vs. TEMPERATURE VGS(TH), THRESHOLD VOLTAGE (NORMALIZED) RDS(ON), DRAIN-TO-SOURCE ON RESISTANCE (NORMALIZED) 150 6.5V 4.5V 0 2 4 6 8 10 12 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 3, TYPICAL OUTPUT CHARACTERISTICS RDS(ON), DRAIN-TO-SOURCE ON RESISTANCE ID, DRAIN CURRENT (AMPERES) TJ = -55°C VGS=7V 0 0 250 VGS=10V 200 1.1 1.0 0.9 0.8 0.7 0.6 -50 -25 0 25 50 75 100 125 150 TC, CASE TEMPERATURE (°C) FIGURE 9, THRESHOLD VOLTAGE vs TEMPERATURE 050-5534 Rev C ID, DRAIN CURRENT (AMPERES) VGS=7V, 10V & 15V APT50M50JVR 50,000 10µS OPERATION HERE LIMITED BY RDS (ON) 100µS 100 Ciss 50 C, CAPACITANCE (pF) ID, DRAIN CURRENT (AMPERES) 400 1mS 10 10mS 5 100mS DC 1 TC =+25°C TJ =+150°C SINGLE PULSE .5 IDR, REVERSE DRAIN CURRENT (AMPERES) VGS, GATE-TO-SOURCE VOLTAGE (VOLTS) .01 .1 1 10 50 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 11, TYPICAL CAPACITANCE vs DRAIN-TO-SOURCE VOLTAGE 20 I = I [Cont.] D VDS=100V VDS=250V 12 VDS=400V 8 4 0 Crss 500 1 5 10 50 100 500 VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS) FIGURE 10, MAXIMUM SAFE OPERATING AREA 16 Coss 5,000 1,000 .1 D 10,000 0 200 400 600 800 1000 1200 Qg, TOTAL GATE CHARGE (nC) FIGURE 12, GATE CHARGES vs GATE-TO-SOURCE VOLTAGE 400 TJ =+150°C 100 TJ =+25°C 50 10 5 1 0 0.4 0.8 1.2 1.6 2.0 VSD, SOURCE-TO-DRAIN VOLTAGE (VOLTS) FIGURE 13, TYPICAL SOURCE-DRAIN DIODE FORWARD VOLTAGE SOT-227 (ISOTOP®) Package Outline 11.8 (.463) 12.2 (.480) 31.5 (1.240) 31.7 (1.248) 7.8 (.307) 8.2 (.322) r = 4.0 (.157) (2 places) 8.9 (.350) 9.6 (.378) Hex Nut M4 (4 places) W=4.1 (.161) W=4.3 (.169) H=4.8 (.187) H=4.9 (.193) (4 places) 25.2 (0.992) 0.75 (.030) 12.6 (.496) 25.4 (1.000) 0.85 (.033) 12.8 (.504) 4.0 (.157) 4.2 (.165) (2 places) 1.95 (.077) 2.14 (.084) 3.3 (.129) 3.6 (.143) 14.9 (.587) 15.1 (.594) * Source Drain 30.1 (1.185) 30.3 (1.193) * Source terminals are shorted internally. Current handling capability is equal for either Source terminal. 38.0 (1.496) 38.2 (1.504) 050-5534 Rev C * Source Gate Dimensions in Millimeters and (Inches) "UL Recognized" File No. E145592 ISOTOP® is a Registered Trademark of SGS Thomson. APT's devices are covered by one or more of the following U.S.patents: 4,895,810 5,256,583 5,045,903 4,748,103 5,089,434 5,283,202 5,182,234 5,231,474 5,019,522 5,434,095 5,262,336 5,528,058