ARCH AQF240U-24S

VER : C_0
update : 2012.05.03
AC-DC Switching Power Supply
AQF240U SERIES
240 Watts
KEY FEATURES
„ U Bracket Switching Power Supply
„ Universal Input: 90-264 VAC
„ With P.F.C. Function, PF>0.95
„ Free Air Convection
„ High Efficiency up to 93%
„ RoHS Compliant Design
„ Ultra Compact Size: 6.0 x 4.18 x 1.38 Inches
„ 3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
AQF240U3.8S
Model No.
AQF240U5S
AQF240U12S
AQF240U15S
AQF240U24S
AQF240U28S
AQF240U32S
AQF240U48S
(Preliminary)
152W
Max Output Wattage (W)
Voltage
Input
Output
Protection
Isolation
240W
Frequency (Hz)
47-63 Hz
Current (Full load)
<3.0 A max. (115 VAC) / <1.5 A max. (230 VAC)
Inrush Current (<2ms)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
Leakage Current
< 0.5 mA max.
Power Factor
PF>0.98 (115 VAC) / PF>0.95 (230 VAC) at Full Load
Voltage (V.DC.)
3.8V
Voltage Accuracy
±2%
Current (Convection) (A) max
40
Line Regulation
±1%
Load Regulation
Minimum Load
Maximum Capacitive Load
±1%
1%
470-23,000µF depending on model
Ripple & Noise (max.)
100mVp-p
Efficiency (typ.)
84%
Hold-up Time
13 ms min.
Switching Frequency
5V
12V
15V
24V
28V
32V
48V
40
20
16
10
8.57
7.5
5
92%
92%
92%
93%
100 kHz
88%
Over Power Protection
Auto recovery
Over Voltage Protection
Latch Off
Short Circuit Protection
Latch Off
Input-Output (V.AC)
4000V
Input-FG
(V.AC)
2000V
Output-FG
.(V.AC)
Operating Temperature
Environment
200W
90-264 VAC or 120-370 VDC
120mVp-p
200mVp-p
90%
90%
500V
-10°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Temperature Coefficient
±0.03%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>50,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
Dimension (L x W x H)
6.0 x 4.18 x 1.38 Inches
Physical
Weight
580 g
Cooling Method
Free convection
Safety
Agency Approvals
EMI
CE, UL60950(except 3.8S and 5S)
EMC
(Conducted & Radiated Emission)
EMS (Noise Immunity)
(150.0 x 106.0 x 35.0 mm ) Tolerance ±0.5 mm
EN 55022 class B
EN 55024
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 01.uF & 47uF parallel capacitor.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : C_0
update : 2012.05.03
AC-DC Switching Power Supply
AQF240U SERIES
MECHANICAL DIMENSION
240 Watts
( Top View )
PIN#
SINGLE
1
AC IN (L)
2
AC IN (N)
3
FG
4
+DC OUT
5
+DC OUT
6
-DC OUT
7
-DC OUT
ASSEMBLY INSTRUCTIONS
*U Case T=2.0mm
Customer screws into the length of the case no higher than 0.5mm
(Namely screw length for load plate thickness plus 2.5mm
BLOCK DIAGRAM
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-