Skyworks AS202-321LF Phemt gaas ic high-power sp3t switch lf-2 ghz Datasheet

PRELIMINARY DATA SHEET
AS202-321, AS202-321LF: PHEMT GaAs IC High-Power
SP3T Switch LF–2 GHz
Functional Block Diagram
Positive low voltage control (0/2.75 V operation)
● Low insertion loss (< 0.8 dB @ 2 GHz)
● High isolation (25 dB at 1 and 2 GHz)
● Excellent harmonics performance
(-65 dBc @ 2.75 V 1 GHz, PIN = 34 dBm)
● Miniature QFN-12 plastic package
● PHEMT process
● Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
ANT
●
V3
V1
RF3
RF2
RF1
V2
Features
Description
The AS202-321 is a PHEMT GaAs IC SP3T antenna switch
operating in the 900 MHz and 1800 MHz frequency bands.
Switching between the antenna and Tx/Rx ports is accomplished
with 3 control inputs. When the control inputs are driven with the
appropriate voltages, a low insertion loss path is provided from
an antenna port to an Rx or Tx port, while the other ports have
high attenuation.
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications at 25 °C (0, 2.75 V)
ZO = 50 Ω, unless otherwise noted
Parameter
Frequency
Insertion loss
Ant-RF1, RF2, RF3
LF–0.5 GHz
LF–1.0 GHz
LF–2.0 GHz
Isolation
Ant-RF1, RF2, RF3
LF–0.5 GHz
LF–1.0 GHz
LF–2.0 GHz
Return loss
Ant-RF1, RF2, RF3
LF–0.5 GHz
LF–1.0 GHz
LF–2.0 GHz
Min.
25
22
22
Typ.
Max.
Unit
0.55
0.60
0.80
0.75
0.80
1.10
dB
dB
dB
28
25
25
dB
dB
dB
18
18
14
dB
dB
dB
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200190 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • September 15, 2006
1
PRELIMINARY DATA SHEET • AS202-321, AS202-321LF
Operating Characteristics at 25 °C (0, 2.75 V)
ZO = 50 Ω, unless otherwise noted
Parameter
Condition
Frequency
Min.
Typ.
Max.
Unit
2nd harmonic
34 dBm In @ 2.75 V
1 GHz
-72
dBc
3rd harmonic
34 dBm In @ 2.75 V
1 GHz
-65
dBc
2nd harmonic
32 dBm In @ 2.75 V
2 GHz
-70
dBc
3rd harmonic
32 dBm In @ 2.75 V
2 GHz
-65
dBc
Gate leakage current
34 dBm In @ 2.75 V
0.03
Thermal resistance
25
Control voltages
VHIGH
VLOW
-0.25
2.60
mA
°C/W
0
2.75
0.25
5.00
V
V
Typical Performance Data (0, 2.75 V, CBL = 47 pF)
2.0
0
1.6
-5
1.2
-10
0.8
-15
Isolation (dB)
Insertion Loss (dB)
ZO = 50 Ω, unless otherwise noted
0.4
0
-0.4
Ant-RF1
-0.8
-1.2
-30
Ant-RF1
Ant-RF2
-35
-45
-2.0
-50
0
0.5
1.0
1.5
2.0
2.5
3.0
0
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
Frequency (GHz)
Insertion Loss vs. Frequency
Isolation vs. Frequency
0
2nd and 3rd Harmonics (dBc)
-10
Ant-RF2
-15
Ant-RF3
Ant-RF1
-20
2nd Harmonic
-80
-70
-60
3rd Harmonic
-50
-40
-30
-20
-10
0
-25
0
0.5
1.0
1.5
2.0
2.5
3.0
2.0
2.5
3.0
3.5
4.0
Frequency (GHz)
Control Voltage (V)
Return Loss vs. Frequency
2nd and 3rd Harmonics
vs. Control Voltage
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
3.0
-90
-5
Return Loss (dB)
Ant-RF3
-25
-40
Ant-RF2
Ant-RF3
-1.6
-20
September 15, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200190 Rev. B
4.5
PRELIMINARY DATA SHEET • AS202-321, AS202-321LF
Truth Table
12
10
9
8
2
7
3
N/C
5
RF3
GND
6
RF2
CBL
GND
V2
4
QFN-12
0.008 (0.20 mm)
Seating Plane
0.118 (3.00 mm)
0.001
(0.02 mm)
0.118
(3.00 mm)
0.029
(0.73 mm)
0.007
(0.180 mm)
0.030
(0.75 mm)
± 0.002
(0.05 mm)
0.017
(0.435 mm) Sq.
Pin 1 Indicator
Exposed pad
0.057 (1.45 mm) Sq.
+ 0.004 (0.10 mm)
- 0.006 (0.15 mm)
0.009 (0.23 mm)
+ 0.003 (0.07 mm)
- 0.002 (0.05 mm)
V3
Ant-RF1
Ant-RF2
Ant-RF3
VLOW
Ins. loss
Isolation
Isolation
VLOW
VHIGH
VLOW
Isolation
Ins. loss
Isolation
VLOW
VLOW
VHIGH
Isolation
Isolation
Ins. loss
Absolute Maximum Ratings
Characteristic
Value
RF input power
4 W > 0.5 GHz
0/6 V control
Control voltage
6V
Operating temperature
-40 °C to +85 °C
Storage temperature
-65 °C to +150 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
LF blocks required. CBL = 47 pF for operation >500 MHz.
Pin 1
Indicator
V2
VLOW
V3
CBL
CBL
RF1
11
V1
VHIGH
All other conditions not recommended.
VLOW = 0–0.2 V.
VHIGH = 2.75–5 V.
1
V1
GND
GND
CBL
ANT
Pin Out
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
0.0196
(0.50 mm) BSC
0.022 (0.55 mm)
± 0.004 (0.10 mm)
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200190 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • September 15, 2006
3
PRELIMINARY DATA SHEET • AS202-321, AS202-321LF
Copyright © 2002, 2003, 2004, 2005, 2006, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
September 15, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200190 Rev. B
Similar pages