GLENAIR 100

Braiding
100-003
Tubular Metal Braid ASTM B355 Class 4 OFHC Nickel Plated
Copper for Series 72 & 74 Tubing and Series 75 Conduit
100-003 A 203 L
Product Series
I.D.
A = 36 AWG (Table I)
B = 34 AWG (Table II)
Dash No. (Table I or II)
Lanyard
(Synthetic Fiber)
Lanyard (Omit for none)
Dash
No.
031
062
078
109
125
156
171
188
203
250
375
500
562
625
781
937
1000
1250
1375
1500
2000
2500
Fractional
Equivalent
1/32
1/16
5/64
7/64
1/8
5/32
11/64
3/16
13/64
1/4
3/8
1/2
9/16
5/8
25/32
15/16
1
1 1/4
1 3/8
1 1/2
2
2 1/2
Nominal
I.D.
.031
(.8)
.062 (1.6)
.078 (2.0)
.109 (2.8)
.125 (3.2)
.156 (4.0)
.171 (4.3)
.188 (4.8)
.203 (5.2)
.250 (6.4)
.375 (9.5)
.500 (12.7)
.562 (14.3)
.625 (15.9)
.781 (19.8)
.937 (23.8)
1.000 (25.4)
1.250 (31.8)
1.375 (34.9)
1.500 (38.1)
2.000 (50.8)
2.500 (63.5)
TABLE I (36 AWG)
No. of
No. of
Carriers
Ends
24
24
24
48
24
72
24
96
24
120
24
240
24
168
24
192
24
312
24
384
48
384
48
528
48
624
48
720
48
864
64
640
64
768
72
792
72
864
72
936
96
1152
96
1248
Minimum Order Length
is 100 Feet (30.5M)
Current
Rating Amps
7.0
11.0
16.0
19.0
25.0
40.0
32.0
33.0
46.0
53.0
53.0
62.0
73.0
85.0
88.0
65.0
90.0
Lbs./100 Ft.
(Kg/30.5M)
.20 (.09)
.40 (.18)
.60 (.27)
.83 (.38)
1.03 (.47)
2.09 (.95)
1.43 (.65)
1.63 (.74)
2.80 (1.27)
3.45 (1.56)
3.95 (1.79)
4.77 (2.16)
5.00 (2.27)
5.94 (2.69)
7.35 (3.33)
5.83 (2.64)
7.50 (3.40)
TABLE II (34 AWG)
Fractional
Lbs./100 Ft.
Dash
No. of
No. of
Current
Nominal
Equivalent
No.
Carriers Ends Rating Amps (Kg/30.5M)
I.D.
1/16
.43 (.20)
062
16
32
11.0
.062 (1.6)
7/64
.82 (.37)
109
16
64
19.0
.109 (2.8)
1/8
.92 (.42)
125
24
72
19.0
.125 (3.2)
11/64
1.56 (.71)
171
24
120
36.0
.171 (4.3)
13/64
2.79 (1.27)
203
24
192
46.0
.203 (5.2)
3/8
3.27 (1.48)
375
48
240
53.0
.375 (9.5)
7/16
3.93 (1.78)
437
48
288
44.2
.437 (11.1)
1/2
4.77 (2.16)
500
48
336
62.0
.500 (12.7)
25/32
7.14 (3.24)
781
48
528
88.0
.781 (19.8)
1
7.33 (3.33)
1000
64
576
150.0
1.000 (25.4)
1 1/4
1250
72
648
1.250 (31.8)
1. Consult factory for sizes not shown
2. Direct current ratings are given for information only. Values shown are for uninsulated braid in free air at 86°F (30°C).
Actual values will depend on permissible temperature rise, voltage drop and other conditions of service. Values
should be de-rated if the braid is insulated or in close contact with other components.
© 2003 Glenair, Inc.
CAGE Codes 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: [email protected]
H-3