Astrodyne ASM60-24 60w ultraminiature medical open frame switching power supply Datasheet

6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
ASM60
series
Up to 60W Output Power
Universal 90-264VAC Input
Single and Dual Outputs from 5VDC to 48VDC
High Efficiency up to 86%
4000V Isolation
1U Compatible Height
2”W x 4”L x 1.2”H
Model Number
Output Voltage Max. O/P Amps
Min. O/P Amps
Efficiency @ 230VAC R&N P-P Current Limit
SINGLE OUTPUT
ASM60-5(A)*
ASM60-9(A)*
ASM60-12(A)*
ASM60-15(A)*
ASM60-24(A)*
ASM60-36(A)*
ASM60-48(A)*
5VDC
9VDC
12VDC
15VDC
24VDC
36VDC
48VDC
9
6.66
5
4
2.5
1.66
1.25
0
0
0
0
0
0
0
73%
82%
84%
84%
86%
85%
86%
100mV
100mV
150mV
150mV
150mV
100mV
400mV
112%
135%
162%
162%
162%
125%
162%
DUAL OUTPUT
ASM60D-1
ASM60D-2
ASM60D-3
ASM60D-5
(V1/V2)
5/12VDC
5/15VDC
5/24VDC
5/48VDC
(I1/I2)
5/3
5/2.4
5/1.5
5/0.73
1/0.60
1/0.48
1/0.30
1/0.15
81%
82%
82%
82%
100/120mV
100/150mV
100/240mV
100/400mV
150%
150%
150%
150%
*Note: The Single Outputs can be ordered with Molex 09-50-30x1 I/O connectors.. Simply add the suffix “A” to the end of the Model Number.
For example, ASM60-5A
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
ASM60
6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
Leakage Current
series
GENERAL SPECIFICATIONS
90-264 VAC
47-63 Hz
30A @ 100VAC Input *
60A @ 200VAC Input *
<0.1mA
Input-Out Isolation
Efficiency
Switching Frequency
Safety
4000VAC
See Selection Chart
65Khz, (fixed, typical)
UL, TUV, CB
PHYSICAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Load Regulation (0%-FL)
Single O/P:
± 1%
Dual O/P (V1/V2):
± 3/5% max
Line Regulation (LL-HL)
Single O/P:
± 1% max
Dual O/P (V1/V2):
± 1/2% max
Cross Regulation (Dual Outputs)
(100-20% L w. other O/P at 60%) ± 3/5% max
Preset Accuracy
1%
DC Voltage Adjust (typ)
± 6% of FS (Primary)
Temperature Coefficient
± 0.05%/°C
Ripple/Noise, 20Mhz BW
See Selection Chart
Over Voltage Protection
Clamp, 118-130%
Current Limit, Self Recovering
See Selection Chart *
Short Circuit Protection
Continuous, self-recovering *
Hold Up Time (115V / 60Hz)
10 mS, min.
Size
Construction
Weight
2” x 4” x 1.2”
50.8 x 101.6 x 30.48mm
Open Frame
7oz (198g)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
EMC
MTBF
-10 to +50°C(FL) , See Derate
-25 to +85°C *
0 to + 95%, non-cond *
EN 60601-1-2:2001
185,000 Hrs
Mil Std 217, 25°C
OUTPUT DERATING CURVE
100
80
60
40
20
-10
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
0
10
20
30
40
50
60
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
ASM60
series
MECHANICAL DIMENSIONS with JST Connectors - standard
1.165
29.60
Input Connector: JST B3P-VH
Input Mating Connector: JST VHR-3N or
Molex 51144 Series
Output Connector: JST B4P-VH
Output Mating Connector: JST VHR-4N
or Molex 53520 & 53521 Series
Use with JST # SVH-21T-P1.1 or Molex
# 50539-8100 Crimp Terminals
4 .0 0 0
1 0 1 .6 0
0.150
3.80
1.701
43.20
2.000
50.80
4 X O 3 .1 7 ( O 0 .1 2 5 )
3
4
5
6
L
1
N
2
WWW.ASTRODYNE.COM
All 4 corner holes need to be bonded accordingly to the end
product PE (Protective Earth) path.
3 .7 0 1
94
0 .1 5 0
3 .8 0
Pin #
Single Outputs
Dual Outputs
1
2
3
4
5
6
AC Line
AC Neutral
+ Output
GND
GND
+ Output
AC Line
AC Neutral
+ Output 2
GND
GND
+ Output 1
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
ASM60
series
MECHANICAL DIMENSIONS with Molex Connectors (“A” Versions single outputs only)
1.165
29.60
Input Connector: Molex 09-50-3031
Input Mating Connector: JST VHR-3N or
Molex 51144 Series
Output Connector: Molex 09-50-3041
Output Mating Connector: JST VHR-4N
or Molex 53520 & 53521 Series
Use with JST # SVH-21T-P1.1 or Molex
# 50539-8100 Crimp Terminals
4 .0 0 0
1 0 1 .6 0
0.150
3.80
1.701
43.20
2.000
50.80
All 4 corner holes need to be bonded accordingly to the end
product PE (Protective Earth) path.
3 .7 0 1
94
0 .1 5 0
3 .8 0
4 X O 3 .1 7 ( O 0 .1 2 5 )
3
4
5
6
L 1
N 2
WWW.ASTRODYNE.COM
Pin #
Single Outputs
1
2
3
4
5
6
AC Line
AC Neutral
+ Output
+ Output
GND
GND
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
Similar pages