AZETTLER AZ165-1CT-12D

AZ165
MINIATURE
POWER RELAY
FEATURES
•
•
•
•
•
•
•
•
Plug in/Solder terminals
SPDT through 4PDT arrangement
High switching capacity
AC and DC coils
Push To Test lever available on some models
CE marked
UL, CUR file E43203
TÜV pending
CONTACTS
GENERAL DATA
Arrangement
SPDT (1 Form C)
DPDT (2 Form C)
3PDT (3 Form C)
4PDT (4 Form C)
Ratings
See chart on page 2
UL, CUR
See chart on page 2
Minimum Load
5 VDC, 0.1A
Material
-1CT contact
-2C and 2CT contact
-3C contact
-4C contact
Resistance
Silver
Silver
Silver
Silver
cadmium oxide
cerium
cerium
cerium
< 50 milliohms initially
(24 V, 1 A voltage drop method)
COIL
Power
Life Expectancy
Mechanical
Electrical
Minimum operations
2 x 107 operations
See UL/CUR ratings on page 2
Operate Time
25 msec max. at nominal coil voltage
Release Time
25 msec at nominal coil voltage
(without suppression)
Dielectric Strength
1500 Vrms coil to contact
(at sea level for 1 min.) 1000 Vrms contact to contact
1000 Vrms between contact sets
Insulation
Resistance
100 megohms min. at 500 VDC,
20°C, 50% RH
Dropout
DC: > 10% of nominal coil voltage
AC: > 30% of nominal coil voltage
Ambient Temperature
Operating
Storage
-55°C (-67°F) to 70°C (158°F)
-55°C (-67°F) to 105°C (221°F)
Vibration
0.062" DA at 10–55 Hz
Shock
20 g
At Pickup Voltage
(typical)
DC: 576 mW, 6 to 48 VDC
704 mW, 110 VDC
AC: .768 VA
Enclosure
Polycarbonate
Max. Continuous
Dissipation
DC: 1.2 W (110 V : 1.5 W) at 20°C (68°F)
AC: 1.7 VA at 20°C (68°F)
Terminals
PC
105°C (221°F)
Max. Solder Temp.
250°C (482°F)
Max. Solder Time
5 seconds
Weight
37 grams
Temperature
NOTES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
8/11/03W
AZ165
CONTACT RATINGS
Maximum
Ratings
SPDT Heavy duty, resistive load:
Max. Switched Power: 450 W, 3750 VA
Max. Switched Current: 15 A
Max. Switched Voltage: 30 VDC, 250 VAC
UL/CUR
Ratings
SPDT Heavy duty:
15 A, 250 VAC 100k, Resistive
15 A, 30 VDC, 100k N.O., 30k N.C., Resistive
DPDT Heavy duty:
10 A, 250 VAC, 100k, General use
10 A, 30 VDC, 100k, Resistive
1/3 HP, 120/240 VAC, 100k Motor load
DPDT Heavy duty, resistive load:
Max. Switched Power: 300 W, 2500 VA
Max. Switched Current: 10 A
Max. Switched Voltage: 30 VDC, 250 VAC
DPDT, Standard duty:
7A, 250 VAC, 100k Resistive
7A, 30 VDC, 100k, Resistive
3A, 240 VAC/30 VDC, 100k, General use
DPDT Standard duty, resistive load:
Max. Switched Power: 210 W, 1750 VA
Max. Switched Current: 7 A
Max. Switched Voltage: 30 VDC, 250 VAC
3PDT, 4PDT, Standard duty:
5A, 250 VAC, 100k, Resistive
5A, 30 VDC, 100k, Resistive
3A, 240 VAC/30 VDC, 100k, General use
3PDT, 4PDT, Standard duty, resistive load:
Max. Switched Power: 150 W, 1250 VA
Max. Switched Current: 5 A
Max. Switched Voltage: 30 VDC, 250 VAC
MECHANICAL DATA
AZ165-_C
AZ165-_CT
.047
[1.2]
.098
[2.5]
.197
[5.0]
.846
[21.5]
.134
[3.4]
1.378
[35.0]
2
3
4
1
2
3
1
4
5
6
7
8
4
5
6
5
8
10
11
12
7
14
13
.020
[0.5]
8
9
9
12
14
13
14
1
2
1
2
1
2
3
4
1
2
3
1
4
1
2
1
3
4
3
4
5
6
7
8
4
5
6
5
8
3
4
3
4
12
5
6
5
6
6
5
7
9
6
5
7
8
8
10
11
14
+
4C
3C
2C
2CT
7
12
13
4C
1.102
[28.0]
Viewed Towards Terminal
1
9
ø.098
[ø2.5]
1.378
[35.0]
.020
[0.5]
WIRING DIAGRAM
13
.252
[6.4]
1.102
[28.0]
.209
[5.3]
.846
[21.5]
8
9
9
14
13
-
+
14
13
-
3C
+
8
7
-
2C
2
8
7
-
+
2CT
+
1CT
1CT
WITH LED
Viewed Towards Terminal
TERMINAL LAYOUTS
.226
[5.7]
.169
[4.3]
.520
[13.2]
.161
[4.1]
.661
[16.8]
.409
[10.4]
.173
[4.4]
.169
[4.3]
.163
[4.1]
.520
[13.2]
.161
[4.1]
.661
[16.8]
.169
[4.3]
.260
[6.6]
.163
[4.1]
.409
[10.4]
.661
[16.8]
.156
[4.0]
.394
[10.0]
.520
[13.2]
.161
[4.1]
.181
[4.6]
.163
[4.1]
.417
[10.6]
.409
[10.4]
.699
[17.75]
.559
[14.2]
4C
3C
2C
1CT & 2CT
8/11/03W
AZ165
RELAY ORDERING DATA
STANDARD RELAYS: DC Coil
COIL SPECIFICATIONS
Nominal Coil
VDC
5
Must Operate
VDC
4.0
Max. Continuous
VDC
5.5
Nominal Current
mA ± 10%
181.0
6
4.8
6.6
150.0
12
9.6
13.2
75.0
24
19.2
26.4
48
38.4
52.8
110
88.0
121.0
Coil Resistance
27.5 ± 10%
40.0 ± 10%
ORDER NUMBER*
AZ165–2C–5D
AZ165–2C–6D
160
± 10%
AZ165–2C–12D
36.9
650
± 10%
AZ165–2C–24D
18.5
2600
± 15%
AZ165–2C–48D
10.0
11,000
± 15%
AZ165–2C–110D
STANDARD RELAYS: AC Coil (50/60 Hz)
COIL SPECIFICATIONS
Nominal Current
mA ± 10%
200.0
Coil Resistance
ORDER NUMBER*
Nominal Coil
VAC
6
Must Operate
VAC
4.8
Max. Continuous
VAC
7.1
12
9.6
14.3
100.0
24
19.2
28.6
50.0
184
± 10%
48
38.4
57.1
25.0
735
± 10%
AZ165–2C–48A
120
96.0
143.0
10.0
4,550
± 10%
AZ165–2C–120A
220
176.0
261.0
5.5
14,400
± 15%
AZ165–2C–220A
240
192.0
288.0
5.0
22,000
± 15%
AZ165–2C–240A
11.5 ± 10%
AZ165–2C–6A
46.0 ± 10%
AZ165–2C–12A
AZ165–2C–24A
* For 3PDT or 4PDT substitute “-3C” or “-4C” for “-2C”. For LED add “1” to the end of p/n. “-2C” and “-4C” versions are available with a lockable “push to test”
lever. Add suffix “P” to part number for “Push to Test” lever.
RELAY ORDERING DATA
HEAVY DUTY RELAYS: DC Coil
COIL SPECIFICATIONS
Nominal Coil
VDC
5
Nominal Current
mA ± 10%
181.0
Coil Resistance
ORDER NUMBER*
Must Operate
VDC
4.0
Max. Continuous
VDC
5.5
6
4.8
6.6
150.0
12
9.6
13.2
75.0
160
± 10%
AZ165–1CT–12D
24
19.2
26.4
36.9
650
± 10%
AZ165–1CT–24D
48
38.4
52.8
18.5
2600
± 15%
AZ165–1CT–48D
110
88.0
121.0
10.0
11,000
± 15%
AZ165–1CT–110D
27.5 ± 10%
AZ165–1CT–5D
40.0 ± 10%
AZ165–1CT–6D
HEAVY DUTY RELAYS: AC Coil (50/60 Hz)
COIL SPECIFICATIONS
Nominal Coil
VAC
6
Must Operate
VAC
4.8
Max. Continuous
VAC
7.1
Nominal Current
mA ± 10%
200.0
12
9.6
14.3
100.0
24
19.2
28.6
50.0
Coil Resistance
ORDER NUMBER*
11.5 ± 10%
AZ165–1CT–6A
46.0 ± 10%
AZ165–1CT–12A
184
± 10%
AZ165–1CT–24A
48
38.4
57.1
25.0
735
± 10%
AZ165–1CT–48A
120
96.0
143.0
10.0
4,550
± 10%
AZ165–1CT–120A
220
176.0
261.0
5.5
14,400
± 15%
AZ165–1CT–220A
240
192.0
288.0
5.0
22,000
± 15%
AZ165–1CT–240A
* For DPDT substitute “-2CT” for “-1CT”. For LED add “1” to the end of p/n.
8/11/03W