AZ830 POLARIZED DIP RELAY SINGLE SIDE STABLE FEATURES • • • • • • • • • • Low profile for compact board spacing DC coils to 48 VDC High sensitivity, 96 mW pickup Life expectancy to 100 million operations High switching capacity, 60 W, 125 VA Fits standard 16 pin IC socket Epoxy sealed for automatic wave soldering and cleaning Meets FCC Part 68.302 1500 V lightning surge Meets FCC Part 68.304 1000 V dielectric UL file E43203 (UL1950) GENERAL DATA Life Expectancy Mechanical Electrical Minimum operations 1 x 108 1 x 105 at 2 A, 30 VDC or 1 A, 125 VAC 2 x 106 at 1 A, 30 VDC or .5 A, 125 VAC (see table for additional figures) Operate Time (typical) 3 ms at nominal coil voltage Release Time (typical) 2 ms at nominal coil voltage (with no coil suppression) Capacitance Contact to contact: 1.0 pF Contact set to contact: 1.0 pF Contact to coil: 2.0 pF Bounce (typical) At 10 mA contact current 1.5 ms at operate N.O. side 2.5 ms at operate N.C. side Dielectric Strength (at sea level) 1500 Vrms contact to coil 1000 Vrms between contact sets 1000 Vrms across contacts Meets FCC Part 68.302 lightning surge Meets FCC Part 68.304 V dielectric Insulation Resistance 1000 megohms min. at 20°C, 500 VDC, 50% RH Dropout Greater than 10% of nominal coil voltage Ambient Temperature Operating At nominal coil voltage Standard: -40°C (-40°F) to 70°C (158°F) Sensitive: -40°C (-40°F) to 85°C (185°F) Ultra-Sensitive: -40°C (-40°F) to 90°C (194°F) All: -40°C (-40°F) to 115°C (239°F) CONTACTS Arrangement DPDT (2 Form C) Bifurcated crossbar contacts Ratings Resistive load: Max. Max. Max. Max. Rated Load UL switched power: 60 W or 125 VA switched current: 2 A switched voltage: 250 VDC or 300 VAC carry current: 3A 2 A at 30 VDC 1 A at 120 VAC Material Silver alloy, gold clad. Resistance < 50 milliohms initially COIL Power At Pickup Voltage (typical) Standard coil: 200 mW Sensitive coil: 100 mW Ultra-Sensitive coil: 96 mW Max. Continuous Dissipation 1.0 W at 20°C (68°F) 0.9 W at 40°C (104°F) Temperature Rise Standard: 38°C (68°F) at nominal coil voltage Sensitive: 21°C (38°F) at nominal coil voltage Ultra-Sensitive: 16°C (29°F) at nominal coil voltage Temperature Max. 115°C (239°F) NOTES 1. 2. 3. 4. All values at 20°C (68°F). Relay may pull in with less than “Must Operate” value. Relay has fixed coil polarity. For complete isolation between the relay’s magnetic fields, it is recommended that a .197" (5.0 mm) space be provided between adjacent relays. 5. Relay adjustment may be affected if undue pressure is exerted on relay case. 6. Specifications subject to change without notice. Storage Vibration 0.062" DA at 10–55 Hz Shock 40 g Enclosure P.B.T. polyester Terminals Tinned copper alloy, P.C. Max. Solder Temp. 270°C (518°F) Max. Solder Time 5 seconds Max. Solvent Temp. 80°C (176°F) Max. Immersion Time 30 seconds Weight 5 grams 8/3/07W AZ830 RELAY ORDERING DATA TYPICAL CONTACT LIFE EXPECTANCY NUMBER OF OPERATIONS COIL SPECIFICATIONS STANDARD COIL Nominal Max. Coil Must Coil Continuous Resistance Operate ORDER NUMBER* VDC VDC ± 10% VDC 3 4.5 22.5 2.1 AZ830–2C–3DE 5 7.5 62.5 3.5 AZ830–2C–5DE 6 9.0 90 4.2 AZ830–2C–6DE 9 13.5 203 6.3 AZ830–2C–9DE 12 18.0 360 8.4 AZ830–2C–12DE 24 36.0 1440 16.8 AZ830–2C–24DE 48 72.0 5760 33.6 AZ830–2C–48DE SENSITIVE COIL 3 6.4 45 2.1 AZ830–2C–3DSE 5 10.6 125 3.5 AZ830–2C–5DSE 9 19.1 405 6.3 AZ830–2C–9DSE 12 25.5 720 8.4 AZ830–2C–12DSE 24 50.9 2880 16.8 AZ830–2C–24DSE 48 101.8 11520 33.6 AZ830–2C–48DSE 7.3 60 2.4 AZ830–2C–3DSSE 5 12.3 167 4.0 AZ830–2C–5DSSE 9 22.0 540 7.2 AZ830–2C–9DSSE 12 29.4 960 9.6 AZ830–2C–12DSSE 24 58.8 3840 19.2 AZ830–2C–24DSSE POWER 50 mV 30 VDC 30 VDC 30 VDC 60 VDC 60 VDC 60 VDC 30 VAC 30 VAC 30 VAC 60 VAC 60 VAC 60 VAC 125 VAC 125 VAC 125 VAC 50 µW 60 W 40 W 20 W 60 W 40 W 20 W 120 VA 80 VA 40 VA 120 VA 80 VA 40 VA 125 VA 80 VA 40 VA RESISTIVE LOAD 5x 107 5 x 105 1 x 106 3 x 106 5 x 105 1 x 106 3 x 106 5 x 105 1 x 106 3 x 106 5 x 105 1 x 106 3 x 106 5 x 105 1 x 106 3 x 106 INDUCTIVE LOAD 5 x 107 15 x 104 3 x 105 1 x 106 — — — 15 x 104 3 x 105 1 x 106 15 x 104 3 x 105 1 x 106 15 x 104 3 x 105 1 x 106 NOTES: 1. Relays operated at nominal coil voltage. 2. Inductive load tests are at 0.7 power factor. 3. Table represents typical life figures and are not guaranteed minimums. ULTRA-SENSITIVE COIL 3 VOLTAGE Maximum Switching Capacity 10.0 9.0 8.0 7.0 6.0 5.0 4.0 * Add suffix “R” to indicate reversed polarity. 3.0 Current 2.0 MECHANICAL DATA .200 (5.07) .200 (5.07) .390 (9.9) (.024 ± .005) (0.6 ± 0.13) TYP 1000 400 500 600 700 800 900 300 200 100 50 60 70 80 90 .1 40 .2 30 0.03 DIA (0.8) (8 HOLES) .3 20 .044 (1.1) REF .044 (1.1) REF .300 (7.61) DC Resistive Load 10 .015 (0.38) .386 (9.8) .044 (1.1) .9 .8 .7 .6 .5 .4 PC BOARD LAYOUT .788 (20.0) .138 (3.5) AC Resistive Load 1.0 Voltage 0.1 (2.54) Viewed toward terminals WIRING DIAGRAM + 1 4 6 8 16 13 11 9 – .012 ± .005 (0.3 ± 0.13) TYP (WATCH FOR POLARITY) Viewed toward terminals Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010" 8/3/07W