EPCOS B84113-C-L110 Sifi-c for very high insertion loss rated voltage 250 v~, 50/60 hz rated current 3 a to 10 a Datasheet

2-Line Filters
B84113
SIFI-C Series
SIFI-C for very high insertion loss
Rated voltage 250 V~, 50/60 Hz
Rated current 3 A to 10 A
Construction
■ Two-line filter
■ Metal case
■ Polyurethane potting (UL 94 V-0)
Features
■
■
■
■
■
Compact design
Low leakage current
All relevant approvals
Cost-optimized construction
Also for assembly on top-hat rails
Applications
■ Switch-mode power supplies in
– industrial electronics
– telecommunications
– data systems
– medical engineering
Case styles and terminal styles
Case style A
Tab connectors on face ends, lateral mounting tabs.
Particularly suitable for mounting on a shielding wall.
Case style B
Tab connectors on face ends, mounting tabs on face ends.
Case style K
IEC connector as per IEC 60320 C 14 on line side,
tab connectors on load side, mounting holes with metric thread.
Case style L
Litz wires on face ends
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
154 03/01
2-Line Filters
B84113
SIFI-C Series
Circuit diagram
LINE
LOAD
N
N’
L
L’
SSB0257-G
Technical data
Rated voltage V R
250 V~, 50/60 Hz
Rated current IR
Referred to 40 °C ambient temperature
Test voltage V P
1414 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
Leakage current lleak
< 0,5 mA at 230 V~, 50 Hz
Discharge resistors
The discharge resistors are rated such that one second after
having disconnected the device from the power line, the
voltage at the line connector should have dropped to 34 V.
Climatic category
In accordance with EN 60068-1
25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test)
Approvals
EN 133221
Characteristics and ordering codes
IR
CR
LR
Case
style
A
Appr. Ordering code
weight
g
Mounting plate
for top-hat rail
(ordering code)
3
2 × 0,47 µF (X2) 4 × 4,7 mH A
+
B
2 × 4700 pF (Y2)
K
L
210
210
270
210
B84113-C-A30
B84113-C-B30
B84113-C-K30
B84113-C-L30
—
C62122-A132-B92
—
—
6
2 × 0,47 µF (X2) 4 × 4,7 mH A
+
B
2 × 4700 pF (Y2)
L
510
510
510
B84113-C-A60
B84113-C-B60
B84113-C-L60
—
C62122-A132-B95
—
10
2 × 0,47 µF (X2) 4 × 3,6 mH A
+
B
2 × 4700 pF (Y2)
L
690
690
690
B84113-C-A110
B84113-C-B110
B84113-C-L110
—
C62122-A132-B95
—
155 03/01
2-Line Filters
B84113
SIFI-C Series
Case styles and dimensions
Case
style
Ordering
code
B84113-
Dimensions in mm
b2
b3
b4
b1
l1
l2
l3
l4
h1
h2
Litz
mm2
Style
1015
A
B
K
L
-C-A30
-C-B30
-C-K30
-C-L30
50,8
50,8
50,8
50,8
70
—
—
—
63,5
63,5
63,5
63,5
—
74,7
—
74,7
—
84,5
—
84,5
89,5
89,5
—
—
38,1
38,1
38
38,1
28
28
—
—
—
—
—
0,82
—
—
—
AWG18
A
B
L
-C-A60
-C-B60
-C-L60
—
see dimensional drawing
see dimensional drawing
133 142,9 153 —
44,5 —
0,82
AWG18
A
B
L
-C-A110
-C-B110
-C-L110
—
see dimensional drawing
see dimensional drawing
133 142,9 153 —
44,5 —
1,35
AWG16
31,5
31,5
—
—
50,8 —
50,8 —
60,4
—
—
—
—
—
Case style A
Case style A
B84113-C-A30
B84113-C-A60
B84113-C-A110
Tab connector
Tab connector
156 03/01
2-Line Filters
B84113
SIFI-C Series
Case style B
Case style B
B84113-C-B30
B84113-C-B60
B84113-C-B110
Tab connector
Tab connector
157 03/01
2-Line Filters
B84113
SIFI-C Series
Case style K
Case style L
Tab connector
BN
BU
Mounting detail
BN GN/YE
158 03/01
BU
2-Line Filters
B84113
SIFI-C Series
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84113-C-*30
B84113-C-*60
SSB0258-P
100
αe
dB
αe
dB
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
Hz 10 8
f
SSB0259-X
100
0
10 4
B84113-C-*110
SSB0260-1
100
αe
dB
80
60
40
20
0
10 4
10 5
10 6
10 7
Hz 10 8
f
159 03/01
10 5
10 6
10 7
Hz 10 8
f
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1