EPCOS B84131M0001G125

EMC filters
4-line filters
for installations and systems
Rated current 6 to 125 A
Series/Type:
B84131
Date:
January 2006
 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the
information contained therein without EPCOS’ prior express consent is prohibited.
4-line filters
B84131
for installations and systems
Power line filters for 3-phase systems
Rated voltage 440/250 V AC, 50/60 Hz
Rated current 6 to 125 A
Construction
■ 4-line filter
■ Metal case
Features
■
■
■
■
High insertion loss
Compact, cost-optimized design
Easy to install
ENEC10, UL and CSA approval
Applications
■ Power supplies for
– data systems, telecom systems
– medical equipment, industrial installations
– copiers
Terminals
■ Tab connectors 6.3 × 0.8 mm
■ Screw terminals
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current, rated temperature,
climatic category, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Circuit diagram
LINE
LOAD
L1
L1’
L2
L2’
L3
L3’
N
N
SSB0338-G
Please read Cautions and warnings and
Important notes at the end of this document.
2
01/06
4-line filters
B84131
for installations and systems
Technical data and measuring conditions
Rated voltage VR
440/250 V AC, 50/60 Hz
Rated current IR
Referred to 40 °C ambient temperature
Test voltage Vtest
1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Leakage current lleak
At 400 V AC, 50 Hz
Climatic category (IEC 60068-1)
25/085/21 (–25 °C/+85 °C/21 days damp heat test)
Approvals
EN 133200, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
VR
AC
V
440/250
IR
Ileak
A
mA
Approx.
weight
kg
Ordering code
Approvals
6
< 3.5
0.8
B84131A0006A001
×
–
–
16
< 3.5
1.5
B84131M0003A116
×
×
×
25
< 3.5
2.3
B84131M0001G125
×
×
35
< 3.5
2.3
B84131M0001G135
×
×
×
35
< 3.5
2.3
B84131M0001H135
–
×
×
50
< 3.5
4.5
B84131M0002G150
×
×
×
63
< 3.5
4.5
B84131M0002G163
×
×
×
80
< 3.5
12.5
B84131M0004G180
×
–
–
125
< 3.5
12.5
B84131M0004G225
×
–
–
× = approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
4-line filters
B84131
for installations and systems
Dimensional drawings
B84131A0006A001 (6 A)
162±1
L1’
L1
N
13±0.5
N’
L2 L3
46±0.5
L3’ L2’
20±0.5
30±0.2
135±0.8
Tab connector A6.3 x 0.8
87±1
LOAD
62±0.5
LINE
75±0.2
M5 (4x)
44±0.2
SSB0958-X-E
B84131M0003A116 (16 A)
Tab connector A6.3 x 0.8
174.5
104
24.6 24.6 24.6
15.1
52.5
36
50
13.5
149
52
44±0.2
M5 x 6
1)
14.5
75±0.3
1) Also suitable for screws with 10-32 UNF thread
Please read Cautions and warnings and
Important notes at the end of this document.
SSB0339-P-E
4
01/06
4-line filters
B84131
for installations and systems
B84131M0001G125, B84131M0001G135/H135 (25 A, 35 A)
M6 and/or
10-32 UNF
104
24.6 24.6 24.6
15.1
14±0.3
149
80
33.5
23
15
52.5±0.8
52
44±0.2
M5 x 6
14.5
1)
75±0.3
1) Also suitable for screws with 10-32 UNF thread
Type
SSB0321-L-E
IR
Screw thread
Tightening torque
B84131M0001
A
G125
25
M6
3
G135
35
M6
3
H135
35
10-32 UNF
2
Nm
B84131M0002G150, B84131M0002G163 (50 A, 63 A)
Screw thread M6
141
131
28.6 24.6 24.6 24.6
Tightening
torque 3 Nm
122
21.8
47
M6
23
48.5
44±0.2
65.5
M5 x 6 1)
13
105±0.3
1) Also suitable for screws with 10-32 UNF thread
Please read Cautions and warnings and
Important notes at the end of this document.
SSB0322-U-E
5
01/06
4-line filters
B84131
for installations and systems
B84131M0004G180, B84131M0004G225 (80 A, 125 A)
Screw thread M10
Tightening
torque 10 Nm
220±1.2
160±0.3
25±0.5
120±0.3
M5 x 6 1)
1) Also suitable for screws with 10-32 UNF thread
Please read Cautions and warnings and
Important notes at the end of this document.
30±0.5
150±1.2
M10
35±0.8
150±1.2
35±0.8
35±0.8
35±0.8
SSB0544-3-E
6
01/06
4-line filters
B84131
for installations and systems
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 6 A
Filters for 16 A
SSB1063-I
100
dB B84131A0006A001
α
SSB0342-9
100
dB B84131M0003A116
α
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
0
10 4
Hz 10 8
f
Filters for 25 A
SSB1676-H
α
α
10 7
Hz 10 8
f
80
60
60
40
40
20
20
10 6
10 7
0
10 4
Hz 10 8
f
Please read Cautions and warnings and
Important notes at the end of this document.
7
SSB0343-H
100
dB B84131M0001G135
B84131M0001H135
80
10 5
10 6
Filters for 35 A
100
dB B84131M0001G125
0
10 4
10 5
01/06
10 5
10 6
10 7
Hz 10 8
f
4-line filters
B84131
for installations and systems
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 50 A
Filters for 63 A
100
dB B84131M0002G150
SSB0541-D
SSB0345-Y
100
dB B84131M0002G163
α
α
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
0
10 4
Hz 10 8
f
Filters for 80 A
10 5
10 6
10 7
Hz 10 8
f
Filters for 125 A
SSB0545-B
100
dB B84131M0004G180
α
SSB0546-J
100
dB B84131M0004G225
α
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
0
10 4
Hz 10 8
f
Please read Cautions and warnings and
Important notes at the end of this document.
8
01/06
10 5
10 6
10 7
Hz 10 8
f
EMC filters
Cautions and warnings
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
operation (see
). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro­
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low­
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warnings
■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
■
■
■
■
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Danger­
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen­
cies that may cause resonances etc. can lead to destruction of the filter housing.
EMC filters must be protected in the application against impermissible exceeding of the rated
currents by suitable overcurrent protective.
9
01/06
EMC filters
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As
a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third
parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
10
01/06