EMC filters 3-line filters for converters and power electronics Rated current 8 to 180 A Series/Type: B84143A*R000 Date: January 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior express consent is prohibited. 3-line filters B84143A*R000 for converters and power electronics Power line filters for 3-phase systems Rated voltage 480/275 V AC, 50/60 Hz Rated current 8 to 180 A Alternative version ■ Series B84143A*R105 offers a low-cost solution Construction ■ 3-line filter ■ Metal case Features ■ ■ ■ ■ ■ High insertion loss Optimized leakage current Easy to install Degree of protection: IP 201) Optimized for long motor cables and operation under full load ■ Design complies with EN 133200, UL 1283, CSA C22.2 No.8 ■ UL approval Applications ■ Frequency converters for motor drives, e.g. – elevators – pumps – traction systems – conveyor systems – HVAC systems (heating, ventilation and air conditioning) ■ Wind farms ■ Power supplies Terminals ■ Finger-safe terminal blocks Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer’s logo, ordering code 1) To IEC 60529 Please read Cautions and warnings and Important notes at the end of this document. 2 01/06 3-line filters B84143A*R000 for converters and power electronics Typical circuit diagram LOAD L1’ LINE L1 L2 L2’ L3 L3’ SSB0797-6 Technical data and measuring conditions Rated voltage VR 480/275 V AC, 50/60 Hz Rated current IR Referred to 40 °C ambient temperature Test voltage Vtest 1770 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) Overload capability (thermal) 1.5 · IR for 3 min per hour or 2.5 · IR for 30 s per hour Leakage current Ileak At 400 V AC, 50 Hz Climatic category (IEC 60068-1) 25/100/21 (–25 °C/+100 °C/21 days damp heat test) Approvals UL 1283 for 440/250 V AC Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 3-line filters B84143A*R000 for converters and power electronics Characteristics and ordering codes VR AC V Ileak Terminal cross section mA mm2 IR A Approx. weight kg Rtyp mΩ Ordering code (440/250 V) 8 4 < 3.5 40 2.2 B84143A0008R000 × 12 4 < 3.5 20 2.2 B84143A0012R000 × 16 4 < 3.5 15 2.2 B84143A0016R000 × 25 10 < 3.5 8 3.7 B84143A0025R000 × 36 10 < 3.5 3.8 3.7 B84143A0036R000 × 50 10 <6 2.0 4.0 B84143A0050R000 × 80 25 <6 1.0 9.5 B84143A0080R000 × 120 50 <6 0.75 B84143A0120R000 × 480/275 10 150 50 <6 0.4 10 B84143A0150R000 × 180 95 <6 0.4 13 B84143A0180R000 × × = approval granted For filters for higher currents see B84143B*S080. For filters for compact dimensions see B84143A*R105. Dimensional drawings PE M6 x 24 25±1 1.0±0.1 36±1 81 max. 20.5±0.5 B84143A0008R000 … A0016R000 (8 … 16 A) 12.5±1 86 max. 163 max. LINE LOAD 5.5±0.1 141 max. 113 max. Marking PE L3’ L2’ L1’ 100±0.3 70±0.2 PE L3 L2 L1 Approvals Terminal blocks 4 mm 2 Tightening torque 0.6 ... 0.8 Nm Please read Cautions and warnings and Important notes at the end of this document. SSB1005-R-E 4 01/06 3-line filters B84143A*R000 for converters and power electronics 1±0.1 30±1 91 max. 46±1 31±0.5 B84143A0025R000 … A0050R000 (25 … 50 A) PE M6 x 24 22.5±1 126 max. 216 max. LINE LOAD 6.6±0.2 140±0.3 Marking 156 max. PE L3’ L2’ L1’ PE L3 L2 L1 80±0.2 Terminal blocks 10 mm 2 Tightening torque 1.5 ... 1.8 Nm 166 max. SSB0977-4-E PE M10 x 34 62±0.8 1.0±0.1 141 max. 90±1 48.5±0.5 B84143A0080R000 (80 A) 18±0.5 141 max. 300 max. Marking LINE LOAD 6.6±0.2 221 max. L1’ L2’ L3’ PE 171 max. L1 L2 L3 PE 155±0.3 115±0.2 Terminal blocks 25 mm 2 Tightening torque 4 ... 4.5 Nm Please read Cautions and warnings and Important notes at the end of this document. 5 01/06 SSB0978-C-E 3-line filters B84143A*R000 for converters and power electronics 65±0.8 1.0±0.1 141 max. 97±1 54±0.5 B84143A0120R000, B84143A0150R000 (120 and 150 A) PE M10 x 34 348 max. 18±0.5 141 max. Marking LINE LOAD 6.6±0.2 L1’ L2’ L3’ PE 171 max. L1 L2 L3 PE 155±0.3 115±0.2 Terminal blocks 50 mm 2 Tightening torque 6 ... 8 Nm 261 max. SSB0979-K-E PE M10 x 34 62±0.8 1.0±0.1 141 max. 74±0.5 105±1 B84143A0180R000 (180 A) 16±0.5 141 max. 404 max. Marking LINE LOAD 6.6±0.2 165±0.4 Please read Cautions and warnings and Important notes at the end of this document. L1’ L2’ L3’ PE 171 max. L1 L2 L3 PE 155±0.3 301 max. Terminal blocks 95 mm 2 Tightening torque 15 ... 20 Nm SSB2107-J-E 6 01/06 3-line filters B84143A*R000 for converters and power electronics Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 8 A Filters for 12 A SSB0798-E 100 dB B84143A0008R000 α SSB0799-M 100 dB B84143A0012R000 α 80 80 60 60 40 40 20 20 0 4 10 10 5 10 6 10 7 0 4 10 Hz 10 8 f Filters for 16 A 10 5 10 6 10 7 Hz 10 8 f Filters for 25 A SSB0800-U 100 dB B84143A0016R000 α SSB0801-3 100 dB B84143A0025R000 α 80 80 60 60 40 40 20 20 0 4 10 10 5 10 6 10 7 0 4 10 Hz 10 8 f Please read Cautions and warnings and Important notes at the end of this document. 7 01/06 10 5 10 6 10 7 Hz 10 8 f 3-line filters B84143A*R000 for converters and power electronics Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 36 A Filters for 50 A SSB0802-B 100 dB B84143A0036R000 SSB0985-U 100 dB B84143A0050R000 α α 80 80 60 60 40 40 20 20 0 4 10 10 5 10 6 10 7 0 10 4 Hz 10 8 f Filters for 80 A 10 5 10 6 10 7 Hz 10 8 f Filters for 120 … 180 A SSB0986-3 100 dB 100 dB B84143A0080R000 SSB0987-B α α 80 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 f Please read Cautions and warnings and Important notes at the end of this document. B84143A0120 ... A0180R000 0 4 10 10 5 10 6 10 7 8 8 01/06 Hz 10 8 f EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings ■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such ■ ■ ■ ■ as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 9 01/06 EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 10 01/06