EPCOS B84299-K64-C

2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Power line filters for single-phase systems
with additional LF suppression
Rated voltage 250 V~, 50/60 Hz
Rated current 2 A to 36 A
Construction
■ Two-line filter
■ Metal case
■ Polyurethane potting (UL 94 V-0)
Features
■ Especially high differential-mode
insertion loss from 20 kHz upwards
■ Safe mounting by press-in nuts
■ Space-saving design
Applications
■ Switch-mode power supplies for traction,
safety systems, automation engineering
■ Industrial electronics
Terminals
■ Litz wires
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Circuit diagram
LINE
Blue
Blau
N
L
Schwarz
Black
LOAD
Blue
Blau
N’
L’
Black
Schwarz
SSB0591-E
212 03/01
2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Technical data
Rated voltage V R
250 V~, 50/60 Hz
Rated current I R
Referred to 40 °C ambient temperature
Test voltage V P
1414 V–, 2 s (line/line)
2830 V–, 2 s (lines/case)
Leakage current l leak
at 230 V~, 50 Hz
Climatic category
In accordance with EN 60068-1
25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test)
Characteristics and ordering codes
IR
R typ
A
2
4
6
10
16
25
36
l leak
mΩ
Approx.
weight
kg
530
150
110
50
35
27
12
0,35
0,37
0,82
1
1,8
2,9
2,9
< 3,5
< 3,5
< 3,5
< 3,5
< 3,5
< 3,5
< 10
Ordering code
Approvals
B84299-K61-C
B84299-K62-C
B84299-K63
B84299-K64-C
B84299-K65
B84299-K66
B84299-K67
×
×
—
—
—
—
—
mA
565-3
× = approval granted
213 03/01
—
—
×
×
—
—
—
2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Dimensional drawings
B84299-K61-C, B84299-K62-C
Line
Mounting height
M4; 6 deep
B84299-K63
Line
Mounting height
M4; 8 deep
∗) Ground terminal for shielding braid or fixing stud for cable clamp M4
214 03/01
Type
Length l
B84299-K61-C
B84299-K62-C
65 mm
75 mm
2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Dimensional drawings
B84299-K64-C
Line
Mounting height
M4; 6 deep
B84299-K65
Line
Mounting height
M4; 6 deep
∗) Ground terminal for shielding braid or fixing stud for cable clamp M4
215 03/01
2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Dimensional drawing
B84299-K66, B84299-K67
M5; 7 deep
AWG 12 or 10
Mounting height
Line
Type
Litz wire
Length l (mm)
a
b
B84299-K66
AWG 12; 3,44 mm2
300 (line)
800
B84299-K67
AWG 10; 5,37 mm2
240 (line)
800
∗) Ground terminal for shielding braid or fixing stud for cable clamp M4
216 03/01
2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84299-K61-C
B84299-K62-C
SSB0323-3
100
αe
dB
αe
80
60
60
40
40
20
20
10 5
10 6
10 7
0
10 4
Hz 10 8
f
B84299-K63
dB
10 6
10 7
Hz 10 8
f
αe
dB
80
60
60
40
40
20
20
10 5
10 6
Hz
f
10 7
SSB0326-S
100
80
0
10 4
10 5
B84299-K64-C
SSB0325-J
100
αe
dB
80
0
10 4
SSB0324-B
100
0
10 4
217 03/01
10 5
10 6
Hz
f
10 7
2-Line Filters
B84299-K61
for Installations and Systems
… B84299-K67
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84299-K65
B84299-K66
SSB0327-1
100
αe
dB
αe
dB
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
Hz
f
10 7
0
10 4
B84299-K67
SSB0329-H
100
αe
dB
80
60
40
20
0
10 4
10 5
10 6
Hz
f
SSB0328-9
100
10 7
218 03/01
10 5
10 6
.Hz
f
10 7
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1